982 resultados para Inertial Measurement Unit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to investigate the influence of ankle osteoarthritis (AOA) treatments, i.e., ankle arthrodesis (AA) and total ankle replacement (TAR), on the kinematics of multi-segment foot and ankle complex during relatively long-distance gait. Forty-five subjects in four groups (AOA, AA, TAR, and control) were equipped with a wearable system consisting of inertial sensors installed on the tibia, calcaneus, and medial metatarsals. The subjects walked 50-m twice while the system measured the kinematic parameters of their multi-segment foot: the range of motion of joints between tibia, calcaneus, and medial metatarsals in three anatomical planes, and the peaks of angular velocity of these segments in the sagittal plane. These parameters were then compared among the four groups. It was observed that the range of motion and peak of angular velocities generally improved after TAR and were similar to the control subjects. However, unlike AOA and TAR, AA imposed impairments in the range of motion in the coronal plane for both the tibia-calcaneus and tibia-metatarsals joints. In general, the kinematic parameters showed significant correlation with established clinical scales (FFI and AOFAS), which shows their convergent validity. Based on the kinematic parameters of multi-segment foot during 50-m gait, this study showed significant improvements in foot mobility after TAR, but several significant impairments remained after AA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zero correlation between measurement error and model error has been assumed in existing panel data models dealing specifically with measurement error. We extend this literature and propose a simple model where one regressor is mismeasured, allowing the measurement error to correlate with model error. Zero correlation between measurement error and model error is a special case in our model where correlated measurement error equals zero. We ask two research questions. First, we wonder if the correlated measurement error can be identified in the context of panel data. Second, we wonder if classical instrumental variables in panel data need to be adjusted when correlation between measurement error and model error cannot be ignored. Under some regularity conditions the answer is yes to both questions. We then propose a two-step estimation corresponding to the two questions. The first step estimates correlated measurement error from a reverse regression; and the second step estimates usual coefficients of interest using adjusted instruments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DHSSPS Unit Cost Review Green Park Healthcare Trust

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We use historical data that cover more than one century on real GDP for industrial countries and employ the Pesaran panel unit root test that allows for cross-sectional dependence to test for a unit root on real GDP. We find strong evidence against the unit root null. Our results are robust to the chosen group of countries and the sample period. Key words: real GDP stationarity, cross-sectional dependence, CIPS test. JEL Classification: C23, E32

Relevância:

20.00% 20.00%

Publicador:

Resumo:

iii. Catheter-related bloodstream infection (CR-BSI) diagnosis usually involves catheter withdrawal. An alternative method for CR-BSI diagnosis is the differential time to positivity (DTP) between peripheral and catheter hub blood cultures. This study aims to validate the DTP method in short-term catheters. The results show a low prevalence of CR-BSI in the sample (8.4%). The DTP method is a valid alternative for CR-BSI diagnosis in those cases with monomicrobial cultures (80% sensitivity, 99% specificity, 92% positive predictive value, and 98% negative predictive value) and a cut-off point of 17.7 hours for positivity of hub blood culture may assess in CR-BSI diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess whether formatting the medical order sheet has an effect on the accuracy and security of antibiotics prescription. DESIGN: Prospective assessment of antibiotics prescription over time, before and after the intervention, in comparison with a control ward. SETTING: The medical and surgical intensive care unit (ICU) of a university hospital. PATIENTS: All patients hospitalized in the medical or surgical ICU between February 1 and April 30, 1997, and July 1 and August 31, 2000, for whom antibiotics were prescribed. INTERVENTION: Formatting of the medical order sheet in the surgical ICU in 1998. MEASUREMENTS AND MAIN RESULTS: Compliance with the American Society of Hospital Pharmacists' criteria for prescription safety was measured. The proportion of safe orders increased in both units, but the increase was 4.6 times greater in the surgical ICU (66% vs. 74% in the medical ICU and 48% vs. 74% in the surgical ICU). For unsafe orders, the proportion of ambiguous orders decreased by half in the medical ICU (9% vs. 17%) and nearly disappeared in the surgical ICU (1% vs. 30%). The only missing criterion remaining in the surgical ICU was the drug dose unit, which could not be preformatted. The aim of antibiotics prescription (either prophylactic or therapeutic) was indicated only in 51% of the order sheets. CONCLUSIONS: Formatting of the order sheet markedly increased security of antibiotics prescription. These findings must be confirmed in other settings and with different drug classes. Formatting the medical order sheet decreases the potential for prescribing errors before full computerized prescription is available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study had the objective of to analyze the demographic and bacteriologic data of 32 hospitalized newborns in an neonatal intensive care unit of a public maternity hospital in Rio de Janeiro city, Brazil, seized by Pseudomonas aeruginosa sepsis during a period ranged from July 1997 to July 1999, and to determine the antimicrobial resistance percentage, serotypes and pulsed field gel electrophoresis (PFGE) patterns of 32 strains isolated during this period. The study group presented mean age of 12.5 days, with higher prevalence of hospital infection in males (59.4%) and vaginal delivery (81.2%), than females (40.6%) and cesarean delivery (18.8%), respectively. In this group, 20 (62.5%) patients received antimicrobials before positive blood cultures presentation. A total of 87.5% of the patients were premature, 62.5% presented very low birth weight and 40.6% had asphyxia. We detected high antimicrobial resistance percentage to b-lactams, chloramphenicol, trimethoprim/sulfamethoxazole and tetracycline among the isolated strains. All isolated strains were classified as multi-drug resistant. Most strains presented serotype O11 while PFGE analysis revealed seven distinct clones with isolation predominance of a single clone (75%) isolated from July 1997 to June 1998.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2009, the Sheffield Alcohol Research Group (SARG) at Sheffield University developed the Sheffield Alcohol Policy Model version 2.0 (SAPM) to appraise the potential impact of alcohol policies, including different levels of MUP, for the population of England. In 2013, SARG were commissioned by the DHSSPS and the Department for Social Development to adapt the Sheffield Model to NI in order to appraise the potential impact of a range of alcohol pricing policies. The present report represents the results of this work. Estimates from the Northern Ireland (NI) adaptation of the Sheffield Alcohol Policy Model - version 3 - (SAPM3) suggest: 1. Minimum Unit Pricing (MUP) policies would be effective in reducing alcohol consumption, alcohol related harms (including alcohol-related deaths, hospitalisations, crimes and workplace absences) and the costs associated with those harms. 2. A ban on below-cost selling (implemented as a ban on selling alcohol for below the cost of duty plus the VAT payable on that duty) would have a negligible impact on alcohol consumption or related harms. 3. A ban on price-based promotions in the off-trade, either alone or in tandem with an MUP policy would be effective in reducing alcohol consumption, related harms and associated costs. 4. MUP and promotion ban policies would only have a small impact on moderate drinkers at all levels of income. Somewhat larger impacts would be experienced by increasing risk drinkers, with the most substantial effects being experienced by high risk drinkers. 5. MUP and promotion ban policies would have larger impacts on those in poverty, particularly high risk drinkers, than those not in poverty. However, those in poverty also experience larger relative gains in health and are estimated to marginally reduce their spending due to their reduced drinking under the majority of policies åÊ

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The large spatial inhomogeneity in transmit B, field (B-1(+)) observable in human MR images at hi h static magnetic fields (B-0) severely impairs image quality. To overcome this effect in brain T-1-weighted images the, MPRAGE sequence was modified to generate two different images at different inversion times MP2RAGE By combining the two images in a novel fashion, it was possible to create T-1-weigthed images where the result image was free of proton density contrast, T-2* contrast, reception bias field, and, to first order transmit field inhomogeneity. MP2RAGE sequence parameters were optimized using Bloch equations to maximize contrast-to-noise ratio per unit of time between brain tissues and minimize the effect of B-1(+) variations through space. Images of high anatomical quality and excellent brain tissue differentiation suitable for applications such as segmentation and voxel-based morphometry were obtained at 3 and 7 T. From such T-1-weighted images, acquired within 12 min, high-resolution 3D T-1 maps were routinely calculated at 7 T with sub-millimeter voxel resolution (0.65-0.85 mm isotropic). T-1 maps were validated in phantom experiments. In humans, the T, values obtained at 7 T were 1.15 +/- 0.06 s for white matter (WM) and 1.92 +/- 0.16 s for grey matter (GM), in good agreement with literature values obtained at lower spatial resolution. At 3 T, where whole-brain acquisitions with 1 mm isotropic voxels were acquired in 8 min the T-1 values obtained (0.81 +/- 0.03 S for WM and 1.35 +/- 0.05 for GM) were once again found to be in very good agreement with values in the literature. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effects of recent advances in magnetic resonance imaging (MRI) radiofrequency (RF) coil and parallel imaging technology on brain volume measurement consistency. MATERIALS AND METHODS: In all, 103 whole-brain MRI volumes were acquired at a clinical 3T MRI, equipped with a 12- and 32-channel head coil, using the T1-weighted protocol as employed in the Alzheimer's Disease Neuroimaging Initiative study with parallel imaging accelerations ranging from 1 to 5. An experienced reader performed qualitative ratings of the images. For quantitative analysis, differences in composite width (CW, a measure of image similarity) and boundary shift integral (BSI, a measure of whole-brain atrophy) were calculated. RESULTS: Intra- and intersession comparisons of CW and BSI measures from scans with equal acceleration demonstrated excellent scan-rescan accuracy, even at the highest acceleration applied. Pairs-of-scans acquired with different accelerations exhibited poor scan-rescan consistency only when differences in the acceleration factor were maximized. A change in the coil hardware between compared scans was found to bias the BSI measure. CONCLUSION: The most important findings are that the accelerated acquisitions appear to be compatible with the assessment of high-quality quantitative information and that for highest scan-rescan accuracy in serial scans the acquisition protocol should be kept as consistent as possible over time. J. Magn. Reson. Imaging 2012;36:1234-1240. ©2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Malnutrition is common in critically ill, hospitalized patients and so represents a major problem for intensive care. Nutritional support can be beneficial in such cases and may help preserve vital organ and immune function. Energy requirements, route of delivery and potential complications of nutritional support are discussed in this paper.