975 resultados para Indoor pollutants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extended exposure to ultrafine particles (UFPs) may lead to consequences in children due to their increased susceptibility when compared to older individuals. Since children spend in average 8 h/day in primary schools, assessing the number concentrations of UFPs in these institutions is important in order to evaluate the health risk for children in primary schools caused by indoor air pollution. Thus, the purpose of this study was to assess and determine the sources of indoor UFP number concentrations in urban and rural Portuguese primary schools. Indoor and outdoor ultrafine particle (UFP) number concentrations were measured in six urban schools (US) and two rural schools (RS) located in the north of Portugal, during the heating season. The mean number concentrations of indoor UFPs were significantly higher in urban schools than in rural ones (10.4 × 10(3) and 5.7 × 10(3) pt/cm(3), respectively). Higher UFP levels were associated with higher squared meters per student, floor levels closer to the ground, chalk boards, furniture or floor covering materials made of wood and windows with double-glazing. Indoor number concentrations of ultrafine-particles were inversely correlated with indoor CO2 levels. In the present work, indoor and outdoor concentrations of UFPs in public primary schools located in urban and rural areas were assessed, and the main sources were identified for each environment. The results not only showed that UFP pollution is present in augmented concentrations in US when compared to RS but also revealed some classroom/school characteristics that influence the concentrations of UFPs in primary schools.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: persons who are 65 years or older often spend an important part of their lives indoors thus adverse indoor climate might influence their health status. Objective: to evaluate the influence of indoor air quality and contaminants on older people’s respiratory health. Design: cross-sectional study. Setting: 21 long-term care residences (LTC) in the city of Porto, Portugal. Subjects: older people living in LTC with ≥65 years old. Methods: the Portuguese version of BOLD questionnaire was administered by an interviewer to older residents able to participate (n = 143). Indoor air contaminants (IAC) were measured twice, during winter and summer in 135 areas. Mixed effects logistic regression models were used to study the association between the health questionnaire results and the monitored IAC, adjusted for age, smoking habits, gender and number of years living in the LTC. Results: cough (23%) and sputum (12%) were the major respiratory symptoms, and allergic rhinitis (18%) the main selfreported illness. Overall particulate matter up to 2.5 micrometres in size median concentration was above the reference levels both in winter and summer seasons. Peak values of particulate matter up to 10 micrometres in size (PM10), total volatile organic compounds, carbon dioxide, bacteria and fungi exceeded the reference levels. Older people exposed to PM10 above the reference levels demonstrated higher odds of allergic rhinitis (OR = 2.9, 95% CI: 1.1–7.2). Conclusion: high levels of PM10 were associated with 3-fold odds of allergic rhinitis. No association was found between indoor air chemical and biological contaminants and respiratory symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Children spend a large part of their time at schools, which might be reflected as chronic exposure. Ultrafine particles (UFP) are generally associated with a more severe toxicity compared to fine and coarse particles, due to their ability to penetrate cell membranes. In addition, children tend to be more susceptible to UFP-mediated toxicity compared to adults, due to various factors including undeveloped immune and respiratory systems and inhalation rates. Thus, the purpose of this study was to determine indoor UFP number concentrations in Portuguese primary schools. Ultrafine particles were sampled between January and March 2014 in 10 public primary schools (35 classrooms) located in Porto, Portugal. Overall, the average indoor UFP number concentrations were not significantly different from outdoor concentrations (8.69 × 10(3) vs. 9.25 × 10(3) pt/cm(3), respectively; considering 6.5 h of indoor occupancy). Classrooms with distinct characteristics showed different trends of indoor UFP concentrations. The levels of carbon dioxide were negatively correlated with indoor UFP concentrations. Occupational density was significantly and positively correlated with UFP concentrations. Although the obtained results need to be interpreted with caution since there are no guidelines for UFP levels, special attention needs to be given to source control strategies in order to reduce major particle emissions and ensure good indoor air quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The Malawi National Malaria Control Program conducted Indoor Residual Spraying (IRS) in 2010 and 2013 in selected hot districts along the valleys including Karonga, but no study has been done to measure community satisfaction levels in these areas. Aim To assess satisfaction levels of community with IRS in both rural and urban settings, in Karonga district. Methods A cross-sectional study was conducted in urban village of Mwahimba and rural village of Fundi. Qualitative and quantitative data was collected from households’ representatives through Focus Group Discussions (FGDs) using De Wets’s Schutte tool. Qualitative data was analysed using thematic analysis while numbers and percentages were generated using Microsoft excel. Results Overall level of satisfaction in Fundi was estimated at 69% while that of Mwahimba was at 60.9%. In Fundi village, 66.1 % (37) of the household representatives were satisfied while in Mwahimba village, 60.7 % (34) were satisfied with the IRS programme. Factors that led to satisfaction were minimal adverse effects of the chemical on people after spraying, killing of other insects, sprayer’ courtesy and good communication. Factors behind dissatisfaction include: short residual effect of the chemical used, over-dilution of the chemical and minimal community involvement. Conclusion Despite finding high satisfaction levels in rural village than in an urban village, overall all the villages reported low levels of satisfaction with IRS due to various factors some of which common to both villages. Karonga District Health Office needs to involve the community in the process of spraying by recruiting sprayers from the target area and also explaining the purpose of dilution and the dilution factor to community members.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Indoor aeroallergens are the main cause of sensitization in children and represent a risk factor for the development of allergic diseases. Objective: Identify the major indoor aeroallergens most often sensitized to pediatric patients treated at the Allergy Service at the “Dr. José Eleuterio González” University Hospital of Monterrey Methods: We performed an observational and descriptive study where we reviewed reports of positive skin tests to the following common indoor aeroallergens: Dermatophagoides farinae (D. farinae), Dermatophagoides pteronyssinus (D. pteronyssinus), Canis familiaris (C. familiaris), Felis domesticus (F. domesticus), Blattella germanica (B. germanica) and Periplaneta americana (P. americana), found in patients under 16 years with symptoms of allergy, during the period of 2011-2012. Results: We performed 439 skin tests to aeroallergens in pediatric patients. Of these, 57.6% were male and 42.4% were female. Mean age was 6.3 years. The age groups were under 3 years: 17.8%, 3-5 years: 35%, 6-12 years: 36%, and 13-16 years: 11.2%. The main diagnoses were: allergic rhinitis (71.8%), asthma (16.6%), and atopic dermatitis (4.3%). In 57.9% of the cases, they had at least one positive skin test to any aeroallergen. The rate of sensitization to speciic aeroallergens was: D. Pteronyssinus 49.0%, D. farinae 44.6%, B. germanica 13.9%, P. Americana 10.9%, F. domesticus 10.7%, and C. familiaris 5.9%. Conclusion: Indoor aeroallergen sensitization can occur early in life, although it was more frequent in the preschooler and elementary school group. Dust house mites were the most commom cause of allergic sensitization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article we describe a semantic localization dataset for indoor environments named ViDRILO. The dataset provides five sequences of frames acquired with a mobile robot in two similar office buildings under different lighting conditions. Each frame consists of a point cloud representation of the scene and a perspective image. The frames in the dataset are annotated with the semantic category of the scene, but also with the presence or absence of a list of predefined objects appearing in the scene. In addition to the frames and annotations, the dataset is distributed with a set of tools for its use in both place classification and object recognition tasks. The large number of labeled frames in conjunction with the annotation scheme make this dataset different from existing ones. The ViDRILO dataset is released for use as a benchmark for different problems such as multimodal place classification and object recognition, 3D reconstruction or point cloud data compression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endotoxinas bacterianas são lipopolissacáridos da membrana externa das bactérias Gram-negativas e são responsáveis pela libertação de citocinas no organismo humano. Estas citocinas podem exacerbar a sintomatologia de determinadas patologias, nomeadamente do foro pulmonar, agravando a sua situação clínica. A procura de melhor conforto habitacional, com a criação de micro ambientes "artificiais" dentro de casa, oferece bem-estar, mas por vezes arrasta consigo uma maior quantidade de poluentes aéreos indoor, nomeadamente bioaerossóis. A influência das bactérias Oram­ negativas em suspensão indoor nos níveis basais dos marcadores analíticos sanguíneos de resposta inflamatória e alérgica, é um ponto importante a ter em consideração quando se pretende elevar o grau de conforto de uma habitação sem implicações negativas para a saúde humana. Este estudo demonstra que a presença das endotoxinas bacterianas indoor, na ausência de patologia aguda, não prejudica o ser humano e a melhoria das condições habitacionais não degrada o estado fisiológico dos indivíduos. /Summary: Bacterial endotoxins are lipopolysaccharides found in the outer membrane of Gram­ negative bacteria and are responsible for the release of cytokines in the human body. These cytokines may exacerbate the symptoms of certain diseases, including pulmonary events, worsening their medical condition. The demand for better housing comfort with the creation of "artificial" micro-environments in the house, offers well-being, but often brings a greater quantity of indoor air pollutants, including bioaerosols. The influence of suspended indoor Gram-negative bacteria in basal levels of blood analytical markers of inflammatory and allergic rhinitis, is an important point to consider when attempting to raise the comfort level of a dwelling without negative implications for human health. This study proves that the presence of indoor bacterial endotoxin in the absence of acute pathology, do not affect humans and the improvement of living conditions does not degrade the physiological status of individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The growing world demand for energy supplied by fossil fuels, a major contributor to the emission of pollutants into the atmosphere and causing environmental problems, has been encouraging governments and international organizations to reflect and encourage the use of alternative renewable sources. Among these new possibilities deserves attention biodiesel, fuel cleaner and easy to reproduce. The study of new technologies involving that source is necessary. From this context, the paper aims at analyzing the thermal stability by thermogravimetric analysis, of the waste generated from atmospheric distillation of mixtures with ratios of 5, 10, 15 and 20% palm biodiesel in diesel with and without addition of BHT antioxidant. It was synthesized biodiesel through palm oil, via homogeneous catalysis in the presence of KOH, with and without the use of BHT and subsequently added to the diesel common indoor type (S1800) from a gas station BR. The diesel was already added with 5% biodiesel, and thus the proportions used for these blends were subtracted from the existing ratio in diesel fuel, resulting in the following proportions palm oil biodiesel: 0% (B5), 5% (B10), 10 % (B15) and 15% (B20). From atmospheric distillation analysis, performed in mixtures with and without BHT were collected residue generated by each sample and performed a thermal study from the thermogravimetric analysis at a heating rate of 10 °C.min-1, nitrogen atmosphere and heating to 600 ° C. According to the specifications of Resolution No. 7/2008 for biodiesel, it was found that the material was synthesized in accordance with the specifications. For mixtures, it was noted that the samples were in accordance with the ANP Resolution No. 42/2009. Given the TG / DTG curves of the samples of waste mixtures with and without BHT antioxidant was able to observe that they showed a single stage of thermal decomposition attributed to decomposition of heavy hydrocarbons and esters and other heavier constituents of the waste sample weighed. The thermal behavior of residues from atmospheric distillation of mixtures of diesel / biodiesel is very important to understand how this affects the proper functioning of the engine. A large amount of waste can generate a high content of particulate material, coke formation and carbonaceous deposits in engine valves, compromising their performance

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Routine monitoring of environmental pollution demands simplicity and speed without sacrificing sensitivity or accuracy. The development and application of sensitive, fast and easy to implement analytical methodologies for detecting emerging and traditional water and airborne contaminants in South Florida is presented. A novel method was developed for quantification of the herbicide glyphosate based on lyophilization followed by derivatization and simultaneous detection by fluorescence and mass spectrometry. Samples were analyzed from water canals that will hydrate estuarine wetlands of Biscayne National Park, detecting inputs of glyphosate from both aquatic usage and agricultural runoff from farms. A second study describes a set of fast, automated LC-MS/MS protocols for the analysis of dioctyl sulfosuccinate (DOSS) and 2-butoxyethanol, two components of Corexit®. Around 1.8 million gallons of those dispersant formulations were used in the response efforts for the Gulf of Mexico oil spill in 2010. The methods presented here allow the trace-level detection of these compounds in seawater, crude oil and commercial dispersants formulations. In addition, two methodologies were developed for the analysis of well-known pollutants, namely Polycyclic Aromatic Hydrocarbons (PAHs) and airborne particulate matter (APM). PAHs are ubiquitous environmental contaminants and some are potent carcinogens. Traditional GC-MS analysis is labor-intensive and consumes large amounts of toxic solvents. My study provides an alternative automated SPE-LC-APPI-MS/MS analysis with minimal sample preparation and a lower solvent consumption. The system can inject, extract, clean, separate and detect 28 PAHs and 15 families of alkylated PAHs in 28 minutes. The methodology was tested with environmental samples from Miami. Airborne Particulate Matter is a mixture of particles of chemical and biological origin. Assessment of its elemental composition is critical for the protection of sensitive ecosystems and public health. The APM collected from Port Everglades between 2005 and 2010 was analyzed by ICP-MS after acid digestion of filters. The most abundant elements were Fe and Al, followed by Cu, V and Zn. Enrichment factors show that hazardous elements (Cd, Pb, As, Co, Ni and Cr) are introduced by anthropogenic activities. Data suggest that the major sources of APM were an electricity plant, road dust, industrial emissions and marine vessels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O Presente relatório centra-se no estágio desenvolvido na empresa Hobbyvida Serviços Desportivos, LDA no âmbito da Atividade Física Indoor integrada no Centro de Atividade Física – Aquagym, mais denominado por Ginásio Almourol, onde desenvolvi e cooperei nas atividades do ramo do Cardiofitness como instrutor estagiário. Neste documento encontram-se várias fases de desenvolvimento do trabalho: uma breve introdução teórica ao trabalho em si, passando depois por uma sucinta contextualização teórica acerca do tema do estágio, abordando alguns aspetos mais relevantes de forma a enriquecer o relatório nos diferentes tópicos de trabalho inseridos no mesmo. De seguida, é feita uma focagem geral do local de estágio, atividades que foram desenvolvidas no decorrer das 520 horas totais de estágio. Acompanham em anexo todas as planificações, fundamentações e reflexões que foram desenvolvidas até ao final de estágio. Neste estágio curricular tive a oportunidade de observar, intervir, aconselhar, corrigir e até mesmo cooperar em Exercícios Físicos em contexto indoor, que me ajudou a adquirir ainda mais autonomia perante os utentes e o espaço em si, auferindo conhecimentos dentro desta área tão ampla que é. Numa primeira fase, tive a capacidade de observar o espaço, as máquinas e o seu funcionamento, a forma de trabalho e principalmente acompanhar o meu orientador de estágio. Numa segunda fase já adquiri um pouco mais de autonomia em contexto de trabalho, acompanhando os utentes em todas as fases do exercício consoante o plano de treino, corrigindo a postura e o exercício em si sempre que necessário de forma a puder melhorar a sua performance (em função dos objetivos individuais). Numa fase final, consegui atingir ainda mais competências e com isso tive a capacidade de organizar e realizar planos de aula consoante aquilo que fui aprendendo durante os períodos que mencionei anteriormente e com isso ajudou-me bastante a criar uma maior proximidade, o que me permitiu ser mais útil nas minhas funções profissionais. No final, apresenta-se uma reflexão crítica sobre as minhas aprendizagens, dificuldades e possíveis melhorias, seguida da conclusão.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent advancements in the area of nanotechnology have brought us into a new age of pervasive computing devices. These computing devices grow ever smaller and are being used in ways which were unimaginable before. Recent interest in developing a precise indoor positioning system, as opposed to existing outdoor systems, has given way to much research heading into the area. The use of these small computing devices offers many conveniences for usage in indoor positioning systems. This thesis will deal with using small computing devices Raspberry Pi’s to enable and improve position estimation of mobile devices within closed spaces. The newly patented Orthogonal Perfect DFT Golay coding sequences will be used inside this scenario, and their positioning properties will be tested. After that, testing and comparisons with other coding sequences will be done.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indoor environmental conditions in classrooms, in particular temperature and indoor air quality, influence students’ health, attitude and performance. In recent years, several studies regarding indoor environmental quality of classrooms were published and natural ventilation proved to have great potential, particularly in southern European climate. This research aimed to evaluate indoor environmental conditions in eight schools and to assess their improvement potential by simple natural ventilation strategies. Temperature, relative humidity and carbon dioxide concentration were measured in 32 classrooms. Ventilation performance of the classrooms was characterized using two techniques, first by fan pressurization measurements of the envelope airtightness and later by tracer gas measurements of the air change rate assuming different envelope conditions. A total of 110 tracer gas measurements were made and the results validated ventilation protocols that were tested afterward. The results of the ventilation protocol implementation were encouraging and, overall, a decrease on the CO2 concentration was observed without modifying the comfort conditions. Nevertheless, additional measurements must be performed for winter conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Catedra Ciclismo Indoor CAT001308

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Catedra Ciclismo Indoor CAT001308