861 resultados para Impression


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sacroiliac joint (SIJ) pain is responsible for up to 40% of all cases of lumbar back pain. Objective Report the long-term efficacy of radiofrequency denervation for sacroiliac joint pain at six, twelve and eighteen months. Method Third-two adults’ patients with sacroiliac join pain diagnosis were included for a prospective study. Primary outcome measure was pain intensity on the Numeric Rating Scale (NRS). Secondary outcome measure was Patient Global Impression of Change Scale (PGIC). Results Short-term pain relief was observed, with the mean NRS pain score decreasing from 7.7 ± 1.8 at baseline to 2.8 ± 1.2 at one month and to 3.1 ± 1.9 at six months post-procedure (p < 0.001). Long-term pain relief was sustained at twelve and eighteen months post-procedure, with NRS pain remaining at 3.4 ± 2.1 and 4.0 ± 2.7, respectively. Conclusion Radiofrequency denervation of the SIJ can significantly reduce pain in selected patients with sacroiliac syndrome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the fracture resistance of simulated immature teeth after different intra-radicular treatments. Crowns and roots of bovine incisors were cut transversally and removed to simulate immature teeth. Root canal preparation and flaring were performed using a bur in crown-apex and apex-crown direction. The samples were distributed into 5 groups (n=10): Positive control (PoC) - no root canal flaring or filling; Negative control (NeC) - teeth were sectioned and their root canals were flared; Direct anatomical glass fiber post (RaP) - #2 Reforpost main glass fiber post relined with composite resin; Double tapered conical glass fiber posts (ExP) - #3 Exacto glass fiber post; and #2 Reforpost main glass fiber + Reforpin accessory glass fiber posts (RrP). In RaP, ExP and RrP, 4.0-mm apical plugs were done with MTA Angelus. The specimens were embedded in polystyrene resin inside cylinders and the periodontal ligament was simulated with a polyether-based impression material. The specimens were submitted to compressive fracture strength test (0.5 mm/min at 135° relative to the long axis of the tooth) in a servo-hydraulic mechanical testing machine MTS 810. Data were subjected to one-way ANOVA and Dunnett's C or Tukey's tests (α=0.05). The control groups (PoC and NeC) showed lower fracture strength than the experimental groups. NeC presented the lowest resistance and ExP presented the highest resistance among the experimental groups. The flaring procedures produced a detrimental effect on the fracture resistance of the bovine teeth. Glass fiber intra-radicular posts increased significantly the fracture resistance of simulated immature teeth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Rock Pigeon (Columba livia) submitted for necropsy had an oral white-yellow mass with a friable surface and putrid odor. Impression smears were performed and tissue samples were collected for histopathology. Cytopathological analysis revealed numerous pyriform protozoa, compatible with Trichomonas gallinae. Protozoans were not evident within the lesions by histopathology after staining the samples with Hematoxylin and Eosin or Gomori methenamine silver (GMS) stain. We conclude that impression smears from avian oral trichomoniasis suspects, even during post-mortem evaluation, can be a useful technique for the diagnosis of this disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dental trade has offered dental impression and dental stone for orthodontic use ensuring accurate models. The compatibility between these materials is defined by the wetting of the model surfaces by the mixture water/stone poured over it and the influenced by the method of disinfection of model and disinfectant solution used. It was evaluated the influence of spray disinfection with sodium hypochlorite 1% on the wettability of two commercial alginate (Jeltrate ® - Dentsply and Orthoprint ® - Zhermack) at two commercial type III gypsum (Rio ® - ME and AOBussoli Orthogesso Orthogesso ®-SA). Twenty models were fabricated for each type of alginate, which were divided into two groups (water and sodium hypochlorite), receiving respectively water and sodium hypochlorite 1% spray. Each group of models was then further divided into two subgroups, and on their surface were poured 2 ml of type III gypsum (Gesso Rio® or Orthogesso®). Reached the final setting of the gypsum specimens were sectioned vertically and medially, settled water with sandpaper No. 400 and mounted on suitable device for reading (in the right and left) of the contact angle Carl Zeiss microscope (precision, 001). The results were submitted to ANOVA and founded statistical significance for solutions used. It was concluded that sodium hypochlorite spray improved wettability of alginates studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The cares at the manipulation of the alginate (condensation, disinfection of the impression and the time elapsed until the leak of the plaster) deserve special attention considering the great amount of distortions occurring every time the impression is not fill of plaster in a brief space of time and appropriate storage conditions. Besides its adaptation to the plaster suffers influence of the events happened after the impression is removed of the mouth. The purpose of this research was to evaluate the wetting capacity of three brands of alginate (Jeltrate™,Hydrogum™ e Orthoprint™) by the plaster type III (Rio™) under the influence of disinfection by sodium hypochlorite 1% sprays and the time of storage of 15 minutes,30 minutes, 1 hour, 6, 12 and 24 hours. There were made 60 impressions of each brand of alginate divided in two groups (water and sodium hypochlorite 1%) rearranged after the application of the sodium hypochlorite spray according to the storage time (15 or 30 minutes and 1,6,12, or 24 hours). On the surface of the impressions 2ml of plaster were flowed, proportioned and condensed in agreement with manufacturer‘s instructions. After the final setting expansion the casts were sectioned vertically and medially, regularized at the cut surface (emery paper 400) and setted for reading the contact angle at the microscope Carl Zeiss. The obtained results, submitted to statistical treatment (ANOVA) revealed significant differences when compared the employed solutions (water and sodium hypochlorite 1%) and the time of storage. The sodium hypochlorite 1% exhibited the smallest contact angles and the times of storage of 15 minutes and 6 hours the smallest and larger angles, respectively. It can be concluded that the alginate impressions exhibited larger adaptation to the plaster when disinfected by hypochlorite of sodium 1% and stocked by 15 minutes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The functional impression technique is one of the most important steps for complete and/or partial edentulism treatment. So, correct analysis and record of supporting structures are essential to determine the denture extension. The functional impression technique has two stages - a customized final impression tray and a border impression - which aims to record the optimal denture supporting area. The aim of this study was to review the literature related to border impression and functional impression techniques, describing the technique and materials, and identifying the procedure’s objectives and function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The anatomical and functional impressions philosophies are presented to the professionals who are active in the area, so that they can review concepts and thus obtain more precise molds, based on scientific knowledge. In parallel, impression techniques recommended by the Prosthodontics subject from Araçatuba Dental School – UNESP are also commented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The activities developed in health area are of great importance, because they have the aim to preserve the life of the men, and therefore, must be performed by authorized persons. The increase of the number of dental schools, the decline at the education quality and a higher admission of students with low ability to exercise their profession, are facts that bring disastrous consequences for society. These facts are, also, reflected at the moral, ethical and technical-scientific performance of the professional. The purpose of this clinic case is to show that although there is a significant suplly of education institutions, there is a lack of scientific and adequate technical knowledgement from the graduated dentals surgeons. The patient MSL, 17 year old, female, went to a dental clinic presenting a tray type Vernis, attached to the lower arch. After clinical evaluation, it was showed that an incorrect material was used for the impression technique, being impossible to take out the tray by the conventional manner. The planning for the removal of the tray was through the divide of it. Thus, the consequence of the lack of knowledge in the use of impression materials had caused a great incovinience to the patient. It can be concluded that the rate of malpractice is directly related to the professional preparation, highlighting the importance of quality dental education for a responsible clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)