977 resultados para INJECTION DETERMINATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of serological markers for hepatitis B virus (HBsAg, anti-HBc IgM and Anti-HBc total) was investigated in the serum of 1,396 individuals who had clinical suspect of hepatitis. It was observed that 50.7% of the individuals were positive and, from the total of the studied individuals, 14.5% were positive for HBsAg. From these, 8.5% were also positive for anti-HBc IgM. The analysis in relation to gender showed a higher seroprevalence index among male individuals (p < 0.0001). It was observed the occurrence of subtypes adw2 (62.7%), ayw3 (23.5%), ayw2 (9.8%) and adw4 (3.9%). The viral DNA was detected in 61 (33.9%) HBsAg positive samples and in one sample positive only for anti-HBc total. These results indicate an important incidence of the HBV infection in this population, and reinforce previous studies regarding this virus in the central west region of Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the prostate cancer (PCa) progresses, sarcosine levels increase both in tumor cells and urine samples, suggesting that this metabolite measurements can help in the creation of non-invasive diagnostic methods for this disease. In this work, a biosensor device was developed for the quantification of sarcosine via electrochemical detection of H2O2 (at 0.6 V) generated from the catalyzed oxidation of sarcosine. The detection was carried out after the modification of carbon screen printed electrodes (SPEs) by immobilization of sarcosine oxidase (SOX) on the electrode surface. The strategies used herein included the activation of the carbon films by an electrochemical step and the formation of an NHS/EDAC layer to bond the enzyme to the electrode, the use of metallic or semiconductor nanoparticles layer previously or during the enzyme immobilization. In order to improve the sensor stability and selectivity a polymeric layer with extra enzyme content was further added. The proposed methodology for the detection of sarcosine allowed obtaining a limit of detection (LOD) of 16 nM, using a linear concentration range between 10 and 100 nM. The biosensor was successfully applied to the analysis of sarcosine in urine samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

XIX Meeting of the Portuguese Electrochemical Society - XVI Iberic Meeting of Electrochemistry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfadimethoxine (SDM) is one of the drugs, often used in the aquaculture sector to prevent the spread of disease in freshwater fish aquaculture. Its spread through the soil and surface water can contribute to an increase in bacterial resistance. It is therefore important to control this product in the environment. This work proposes a simple and low-cost potentiometric device to monitor the levels of SDM in aquaculture waters, thus avoiding its unnecessary release throughout the environment. The device combines a micropipette tip with a PVC membrane selective to SDM, prepared from an appropriate cocktail, and an inner reference solution. The membrane includes 1% of a porphyrin derivative acting as ionophore and a small amount of a lipophilic cationic additive (corresponding to 0.2% in molar ratio). The composition of the inner solution was optimized with regard to the kind and/or concentration of primary ion, chelating agent and/or a specific interfering charged species, in different concentration ranges. Electrodes constructed with inner reference solutions of 1 × 10−8 mol/L SDM and 1 × 10−4 mol/L chromate ion showed the best analytical features. Near-Nernstian response was obtained with slopes of −54.1 mV/decade, an extraordinary detection limit of 7.5 ng/mL (2.4 × 10−8 mol/L) when compared with other electrodes of the same type. The reproducibility, stability and response time are good and even better than those obtained by liquid contact ISEs. Recovery values of 98.9% were obtained from the analysis of aquaculture water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel optical disposable probe for screening fluoroquinolones in fish farming waters is presented, having Norfloxacin (NFX) as target compound. The colorimetric reaction takes place in the solid/liquid interface consisting of a plasticized PVC layer carrying the colorimetric reagent and the sample solution. NFX solutions dropped on top of this solid-sensory surface provided a colour change from light yellow to dark orange. Several metals were tested as colorimetric reagents and Fe(III) was selected. The main parameters affecting the obtained colour were assessed and optimised in both liquid and solid phases. The corresponding studies were conducted by visible spectrophotometry and digital image acquisition. The three coordinates of the HSL model system of the collected image (Hue, Saturation and Lightness) were obtained by simple image management (enabled in any computer). The analytical response of the optimised solid-state optical probe against concentration was tested for several mathematical transformations of the colour coordinates. Linear behaviour was observed for logarithm NFX concentration against Hue+Lightness. Under this condition, the sensor exhibited a limit of detection below 50 μM (corresponding to about 16 mg/mL). Visual inspection also enabled semi-quantitative information. The selectivity was ensured against drugs from other chemical groups than fluoroquinolones. Finally, similar procedure was used to prepare an array of sensors for NFX, consisting on different metal species. Cu(II), Mn(II) and aluminon were selected for this purpose. The sensor array was used to detect NFX in aquaculture water, without any prior sample manipulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work reports new sensors for the direct determination of Microcystin-LR (MC-LR) in environmental waters. Both selective membrane and solid contact were optimized to ensure suitable analytical features in potentiometric transduction. The sensing layer consisted of Imprinted Sol–Gel (ISG) materials capable of establishing surface interactions with MC-LR. Non-Imprinted Sol–Gel (NISG) membranes were used as negative control. The effects of an ionic lipophilic additive, time of sol–gel polymerization, time of extraction of MC-LR from the sensitive layer, and pH were also studied. The solid contact was made of carbon, aluminium, titanium, copper or nickel/chromium alloys (80 : 20 or 90 : 10). The best ISG sensor had a carbon solid contact and displayed average slopes of 211.3 mV per decade, with detection limits of 7.3 1010 M, corresponding to 0.75 mg L1 . It showed linear responses in the range of 7.7 1010 to 1.9 109 M of MC-LR (corresponding to 0.77–2.00 mg L1 ), thus including the limiting value for MC-LR in waters (1.0 mg L1 ). The potentiometric-selectivity coefficients were assessed by the matched potential method for ionic species regularly found in waters up to their limiting levels. Chloride (Cl) showed limited interference while aluminium (Al3+), ammonium (NH4 + ), magnesium (Mg2+), manganese (Mn2+), sodium (Na+ ), and sulfate (SO4 2) were unable to cause the required potential change. Spiked solutions were tested with the proposed sensor. The relative errors and standard deviation obtained confirmed the accuracy and precision of the method. It also offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol–gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about −58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes −54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solid-contact sensors for the selective screening of sulfadiazine (SDZ) in aquaculture waters are reported. Sensor surfaces were made from PVC membranes doped with tetraphenylporphyrin-manganese(III) chloride, α-cyclodextrin, β-cyclodextrin, or γ-cyclodextrin ionophores that were dispersed in plasticizer. Some membranes also presented a positive or a negatively charged additive. Phorphyrin-based sensors relied on a charged carrier mechanism. They exhibited a near-Nernstian response with slopes of 52 mV decade−1 and detection limits of 3.91 × 10−5 mol L−1. The addition of cationic lipophilic compounds to the membrane originated Nernstian behaviours, with slopes ranging 59.7–62.0 mV decade−1 and wider linear ranges. Cyclodextrin-based sensors acted as neutral carriers. In general, sensors with positively charged additives showed an improved potentiometric performance when compared to those without additive. Some SDZ selective membranes displayed higher slopes and extended linear concentration ranges with an increasing amount of additive (always <100% ionophore). The sensors were independent from the pH of test solutions within 2–7. The sensors displayed fast response, always <15 s. In general, a good discriminating ability was found in real sample environment. The sensors were successfully applied to the fast screening of SDZ in real waters samples from aquaculture fish farms. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in locus measurements of sulfadiazine or parent-drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new man-tailored biomimetic sensor for Chlorpromazine host-guest interactions and potentiometric transduction is presented. The artificial host was imprinted within methacrylic acid, 2-vinyl pyridine and 2-acrylamido-2-methyl-1-propanesulfonic acid based polymers. Molecularly imprinted particles were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. Slopes and detection limits ranged 51–67 mV/decade and 0.46–3.9 μg/mL, respectively, in steady state conditions. Sensors were independent from the pH of test solutions within 2.0–5.5. Good selectivity was observed towards oxytetracycline, doxytetracycline, ciprofloxacin, enrofloxacin, nalidixic acid, sulfadiazine, trimethoprim, glycine, hydroxylamine, cysteine and creatinine. Analytical features in flowing media were evaluated on a double-channel manifold, with a carrier solution of 5.0 × 10−2 mol/L phosphate buffer. Near-Nernstian response was observed over the concentration range 1.0 × 10−4 to 1.0 × 10−2 mol/L. Average slopes were about 48 mV/decade. The sensors were successfully applied to field monitoring of CPZ in fish samples, offering the advantages of simplicity, accuracy, automation feasibility and applicability to complex samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The manifestations caused by Africanized bee stings depend on the sensitivity of the victim and the toxicity of the venom. Previous studies in our laboratory have demonstrated cardiac changes and acute tubular necrosis (ATN) in the kidney of rats inoculated with Africanized bee venom (ABV). The aim of the present study was to evaluate the changes in mean arterial pressure (MAP) and heart rate (HR) over a period of 24 h after intravenous injection of ABV in awake rats. A significant reduction in basal HR as well as in basal MAP occurred immediately after ABV injection in the experimental animals. HR was back to basal level 2 min after ABV injection and remained normal during the time course of the experiment, while MAP returned to basal level 10 min later and remained at this level for the next 5 h. However, MAP presented again a significant reduction by the 7th and 8th h and returned to the basal level by the 24th h. The fall in MAP may contribute to the pathogenesis of ATN observed. The fall in MAP probably is due to several factors, in addition to the cardiac changes already demonstrated, it is possible that the components of the venom themselves or even substances released in the organism play some role in vascular beds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seroprevalence of HCMV in Costa Rica is greater than 95% in adults; primary infections occur early in life and is the most frequent congenital infection in newborns. The objectives of this study were to determine the genetic variability and genotypes of HCMV gB gene in Costa Rica. Samples were collected from alcoholics, pregnant women, blood donors, AIDS patients, hematology-oncology (HO) children and HCMV isolates from neonates with cytomegalic inclusion disease. A semi-nested PCR system was used to obtain a product of 293-296 bp of the gB gene to be analyzed by Single Stranded Conformational Polymorphism (SSCP) and sequencing to determine the genetic polymorphic pattern and genotypes, respectively. AIDS patients showed the highest polymorphic diversity with 14 different patterns while fifty-six percent of HO children samples showed the same polymorphic pattern, suggesting in this group a possible nosocomial infection. In neonates three genotypes (gB1, gB2 and gB3), were determined while AIDS patients and blood donors only showed one (gB2). Of all samples analyzed only genotypes gB1, 2 and 3 were determined, genotype gB2 was the most frequent (73%) and mixed infections were not detected. The results of the study indicate that SSCP could be an important tool to detect HCMV intra-hospital infections and suggests a need to include additional study populations to better determine the genotype diversity and prevalence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Dissertação que se pretende desenvolver decorre em ambiente industrial numa empresa, em que as principais áreas de actuação dizem respeito à injecção e maquinação de alumínio. Os componentes aí injectados e maquinados, são componentes que servirão posteriormente a indústria automóvel num vasto leque de aplicações, desde componentes para sistemas hidráulicos de travagem e componentes para sistemas de lubrificação. Nesta dissertação foi abordada a temática da redução do tempo de paragem não planeada numa linha de maquinação, pelo que se elencaram as principais causas que originavam essas paragens. Recorrendo à metodologia SMED, e a um vasto conjunto de técnicas auxiliares de determinação de causas como os 5 WHY´s, diagrama de Ishikawa, 5S e Kaizen, foram propostas diversas melhorias para a optimização do procedimento de troca de modelo, incluindo um conjunto de regras que visam a sustentabilidade do processo a médio e longo prazo. Com as melhorias adoptadas, verificou-se uma redução de 27,9% no tempo total de troca de modelo comparativamente com o tempo registado antes da implementação da metodologia SMED. Destaca-se a redução de 75% no tempo de montagem e desmontagem dos dispositivos no 3ºProcesso da linha em estudo. Revelou-se também crucial que para a implementação da técnica SMED ser bem sucedida em termos de eficiência e sustentabilidade, devem ser adoptadas um conjunto de diversas ferramentas “Lean Management” e de normalização do trabalho.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The basidiomycetous yeast Cryptococcus neoformans is an important fungal pathogen mainly in immunocompromised patients. In this study, 47 clinical isolates of C. neoformans from regions of São Paulo State were studied serologically by using the Crypto Check Iatron RM 304-K kit, their genetic diversity was estimated by PCR-fingerprinting with a microsatellite-specific sequence (GACA)4, RAPD with primer 6 (Amersham Pharmacia Biotech), PCR-restriction fragment length polymorphism (RFLP) analysis of the phospholipase B gene (PLB1) digested with AvaI and mating type analysis by PCR. All 47 strains isolated from HIV positive patients included in this study were serotype A and MATalpha. The majority of the isolates (45/47) were VNI and only two were VNII by PCR-fingerprinting and PCR-RFLP analysis. High degree of homogeneity was observed when (GACA)4 was used, being highly correlated (> 0.9). In contrast, the RAPD analysis was more heterogeneous with higher number of molecular profiles. By PCR-RFLP, no new molecular type was found, enhancing the suggestion that the differences based on conserved gene as PLB1, can be resultant of ongoing divergent evolution within the C. neoformans complex, into the current eight subtypes. Our results furnish new information on the molecular epidemiology of C. neoformans in the southeast region of Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the first time, a glassy carbon electrode (GCE) modified with novel N-doped carbon nanotubes (CNT-N) functionalized with MnFe2O4 nanoparticles (MnFe2O4@CNT-N) has been prepared and applied for the electrochemical determination of caffeine (CF), acetaminophen (AC) and ascorbic acid (AA). The electrochemical behaviour of CF, AC and AA on the bare GCE, CNT-N/GCE and MnFe2O4@CNT-N/GCE were carefully investigated using cyclic voltammetry (CV) and square-wave voltammetry (SWV). Compared to bare GCE and CNT-N modified electrode, the MnFe2O4@CNT-N modified electrode can remarkably improve the electrocatalytic activity towards the oxidation of CF, AC and AA with an increase in the anodic peak currents of 52%, 50% and 55%, respectively. Also, the SWV anodic peaks of these molecules could be distinguished from each other at the MnFe2O4@CNT-N modified electrode with enhanced oxidation currents. The linear response ranges for the square wave voltammetric determination of CF, AC and AA were 1.0 × 10−6 to 1.1 × 10−3 mol dm−3, 1.0 × 10−6 to 1.0 × 10−3 mol dm−3 and 2.0 × 10−6 to 1.0 × 10−4 mol dm−3 with detection limit (S/N = 3) of 0.83 × 10−6, 0.83 × 10−6 and 1.8 × 10−6 mol dm−3, respectively. The sensitivity values at the MnFe2O4@CNT-N/GCE for the individual determination of AC, AA and CF and in the presence of the other molecules showed that the quantification of AA and CF show no interferences from the other molecules; however, AA and CF interfered in the determination of AC, with the latter molecule showing the strongest interference. Nevertheless, the obtained results show that MnFe2O4@CNT-N composite material acted as an efficient electrochemical sensor towards the selected biomolecules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development and application of a polyaniline/carbon nanotube (CNT) cyclodextrin matrix (PANI-β-CD/MWCNT)-based electrochemical sensor for the quantitative determination of the herbicide 4-chloro-2-methylphenoxyacetic acid (MCPA) and its main transformation product 4-chloro-2-methylphenol in natural waters are described. A simple cyclic voltammetry-based electrochemical methodology, in phosphate buffer solution at pH 6.0, was used to develop a method to determine both MCPA and 4-chloro-2-methylphenol, without any previous extraction or derivatization steps. A linear concentration range (10 to 50 μmol L−1) and detection limits of 1.1 and 1.9 μmol L−1, respectively, were achieved using optimized cyclic voltammetric parameters. The proposed method was successfully applied to the determination of MCPA and 4-chloro-2-methylphenol in natural water samples with satisfactory recoveries (94 to 107 %) and in good agreement with the results obtained by an established high-performance liquid chromatography technique, no significant differences being found between the methods. Interferences from ionic species and other herbicides used for broad-leaf weed control were shown to be small. The newly developed methodology was also successfully applied to MCPA photodegradation environmental studies.