977 resultados para INFRARED


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have analyzed the spectral sub-bandgap photoresponse of silicon (Si) samples implanted with vanadium (V) at different doses and subsequently processed by pulsed-laser melting. Samples with V concentration clearly above the insulator-metal transition limit show an important increase of the photoresponse with respect to a Si reference sample. Their photoresponse extends into the far infrared region and presents a sharp photoconductivity edge that moves towards lower photon energies as the temperature decreases. The increase of the value of the photoresponse is contrary to the classic understanding of recombination centers action and supports the predictions of the insulator-metal transition theory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measuring skin temperature (TSK) provides important information about the complex thermal control system and could be interesting when carrying out studies about thermoregulation. The most common method to record TSK involves thermocouples at specific locations; however, the use of infrared thermal imaging (IRT) has increased. The two methods use different physical processes to measure TSK, and each has advantages and disadvantages. Therefore, the objective of this study was to compare the mean skin temperature (MTSK) measurements using thermocouples and IRT in three different situations: pre-exercise, exercise and post-exercise. Analysis of the residual scores in Bland-Altman plots showed poor agreement between the MTSK obtained using thermocouples and those using IRT. The averaged error was -0.75 °C during pre-exercise, 1.22 °C during exercise and -1.16 °C during post-exercise, and the reliability between the methods was low in the pre- (ICC = 0.75 [0.12 to 0.93]), during (ICC = 0.49 [-0.80 to 0.85]) and post-exercise (ICC = 0.35 [-1.22 to 0.81] conditions. Thus, there is poor correlation between the values of MTSK measured by thermocouples and IRT pre-exercise, exercise and post-exercise, and low reliability between the two forms of measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La termografía infrarroja (TI) registra el calor irradiado de un cuerpo, que es emitido en un rango del espectro electromagnético que la visión humana no es capaz de identificar. La respuesta térmica depende de una serie de ajustes fisiológicos específicos como la homeostasis corporal y salud del deportista, lo cual permite establecer interesantes aplicaciones en el deporte. El objetivo de este trabajo ha sido revisar la literatura en torno a las aplicaciones de la TI en el ámbito del deporte, y proponer las características óptimas del registro en relación al evaluado, las condiciones ambientales y la cámara utilizada. Concluimos que la principal contribución de la TI en el ámbito del deporte es ayudar a identificar signos de lesión antes de que la lesión se produzca, permitiéndonos actuar de manera preventiva durante el proceso de entrenamiento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From the last decades, infrared thermography is quite often associated with things other than clinical medicine. For example, the chemical, automobile, aeronautic industries and civil engineering. However, thermography is where infrared images of the breast are analyzed by board certified thermographers and an abnormal thermogram is reported as the significant risk for the existence of breast tumor (Ng, 2009). Thermography is a painless, noninvasive, no radiation, as well as being cheaper and faster, easier access. The aim of this review was to identify the views of clinicians on the use of thermography for quantifying the risk of breast cancer. We used articles published recently in a reliable database. Thermography has been convicted over the years; it has been labeled by subjective interpretation. Most of the reviewed articles agree that mammography is currently the main examination chosen by doctors for the screening of breast cancer (Acharya et al., 2010; Kennedy et al., 2009). However, several studies have reported promising results for the technique (Wang et al., 2010). Additionally, some authors suggest that thermography is complementary to other diagnostic methods, and that the best strategy for the early detection of breast cancer would be to use them together (Kennedy et al., 2009; Hersh, 2004). The combination of thermal imaging with other tests would increase accuracy, sensitivity and specificity of the evaluation and allow a better quantification of the risk of breast cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technical improvement and new applications of Infrared Thermography (IRT) with healthy subjects should be accompanied by results about the reproducibility of IRT measurements in different popula-tion groups. In addition, there is a remarkable necessity of a larger supply on software to analyze IRT images of human beings. Therefore, the objectives of this study were: firstly, to investigate the reproducibility of skin temperature (Tsk) on overweight and obese subjects using IRT in different Regions of Interest (ROI), moments and side-to-side differences (?T); and secondly, to check the reliability of a new software called Termotracker®, specialized on the analysis of IRT images of human beings. Methods: 22 overweight and obese males (11) and females (11) (age: 41,51±7,76 years; height: 1,65±0,09 m; weight: 82,41±11,81 Kg; BMI: 30,17±2,58 kg/m²) were assessed in two consecutive thermograms (5 seconds in-between) by the same observer, using an infrared camera (FLIR T335, Sweden) to get 4 IRT images from the whole body. 11 ROI were selected using Termotracker® to analyze its reproducibility and reliability through Intra-class Correlation Coefficient (ICC) and Coefficient of Variation (CV) values. Results: The reproducibility of the side-to-side differences (?T) between two consecutive thermograms was very high in all ROIs (Mean ICC = 0,989), and excellent between two computers (Mean ICC = 0,998). The re-liability of the software was very high in all the ROIs (Mean ICC = 0,999). Intraexaminer reliability analysing the same subjects in two consecutive thermograms was also very high (Mean ICC = 0,997). CV values of the different ROIs were around 2%. Conclusions: Skin temperature on overweight subjects had an excellent reproducibility for consecutive ther-mograms. The reproducibility of thermal asymmetries (?T) was also good but it had the influence of several factors that should be further investigated. Termotracker® reached excellent reliability results and it is a relia-ble and objective software to analyse IRT images of humans beings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a new class of semiconductor device: the optically triggered infrared photodetector (OTIP). This photodetector is based on a new physical principle that allows the detection of infrared light to be switched ON and OFF by means of an external light. Our experimental device, fabricated using InAs/AlGaAs quantum-dot technology, demonstrates normal incidence infrared detection in the 2−6 μm range. The detection is optically triggered by a 590 nm light-emitting diode. Furthermore, the detection gain is achieved in our device without an increase of the noise level. The novel characteristics of OTIPs open up new possibilities for third generation infrared imaging systems

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a new class of semiconductor device: the optically triggered infrared photodetector (OTIP). This photodetector is based on a new physical principle that allows the detection of infrared light to be switched ON and OFF by means of an external light. Our experimental device, fabricated using InAs/AlGaAs quantum-dot technology, demonstrates normal incidence infrared detection in the 2−6 μm range. The detection is optically triggered by a 590 nm light-emitting diode. Furthermore, the detection gain is achieved in our device without an increase of the noise level. The novel characteristics of OTIPs open up new possibilities for third generation infrared imaging systems

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of a common environment for processing different powder foods in the industry has increased the risk of finding peanut traces in powder foods. The analytical methods commonly used for detection of peanut such as enzyme-linked immunosorbent assay (ELISA) and real-time polymerase chain reaction (RT-PCR) represent high specificity and sensitivity but are destructive and time-consuming, and require highly skilled experimenters. The feasibility of NIR hyperspectral imaging (HSI) is studied for the detection of peanut traces down to 0.01% by weight. A principal-component analysis (PCA) was carried out on a dataset of peanut and flour spectra. The obtained loadings were applied to the HSI images of adulterated wheat flour samples with peanut traces. As a result, HSI images were reduced to score images with enhanced contrast between peanut and flour particles. Finally, a threshold was fixed in score images to obtain a binary classification image, and the percentage of peanut adulteration was compared with the percentage of pixels identified as peanut particles. This study allowed the detection of traces of peanut down to 0.01% and quantification of peanut adulteration from 10% to 0.1% with a coefficient of determination (r2) of 0.946. These results show the feasibility of using HSI systems for the detection of peanut traces in conjunction with chemical procedures, such as RT-PCR and ELISA to facilitate enhanced quality-control surveillance on food-product processing lines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Las personas que usan la silla de ruedas como su forma de movilidad prioritaria presentan una elevada incidencia (73%) de dolor de hombro debido al sobreuso y al movimiento repetitivo de la propulsión. Existen numerosos métodos de diagnóstico para la detección de las patologías del hombro, sin embargo la literatura reclama la necesidad de un test no invasivo y fiable, y sugiere la termografía como una técnica adecuada para evaluar el dolor articular. La termografía infrarroja (IRT) proporciona información acerca de los procesos fisiológicos a través del estudio de las distribuciones de la temperatura de la piel. Debido a la alta correlación entre ambos lados corporales, las asimetrías térmicas entre flancos contralaterales son una buena indicación de patologías o disfunciones físicas subyacentes. La fiabilidad de la IRT ha sido estudiada con anterioridad en sujetos sanos, pero nunca en usuarios de sillas de ruedas. Las características especiales de la población con discapacidad (problemas de sudoración y termorregulación, distribución sanguínea o medicación), hacen necesario estudiar los factores que afectan a la aplicación de la IRT en usuarios de sillas de ruedas. La bibliografía discrepa en cuanto a los beneficios o daños resultantes de la práctica de la actividad física en las lesiones de hombro por sobreuso en usuarios de sillas de ruedas. Recientes resultados apuntan a un aumento del riesgo de rotura del manguito rotador en personas con paraplejia que practican deportes con elevación del brazo por encima de la cabeza. Debido a esta falta de acuerdo en la literatura, surge la necesidad de analizar el perfil termográfico en usuarios de sillas de ruedas sedentarios y deportistas y su relación con el dolor de hombro. Hasta la fecha sólo se han publicado estudios termográficos durante el ejercicio en sujetos sanos. Un mayor entendimiento de la respuesta termográfica al ejercicio en silla de ruedas en relación al dolor de hombro clarificará su aparición y desarrollo y permitirá una apropiada intervención. El primer estudio demuestra que la fiabilidad de la IRT en usuarios de sillas de ruedas varía dependiendo de las zonas analizadas, y corrobora que la IRT es una técnica no invasiva, de no contacto, que permite medir la temperatura de la piel, y con la cual avanzar en la investigación en usuarios de sillas de ruedas. El segundo estudio proporciona un perfil de temperatura para usuarios de sillas de ruedas. Los sujetos no deportistas presentaron mayores asimetrías entre lados corporales que los sedentarios, y ambos obtuvieron superiores asimetrías que los sujetos sin discapacidad reportados en la literatura. Los no deportistas también presentaron resultados más elevados en el cuestionario de dolor de hombro. El área con mayores asimetrías térmicas fue hombro. En deportistas, algunas regiones de interés (ROIs) se relacionaron con el dolor de hombro. Estos resultados ayudan a entender el mapa térmico en usuarios de sillas de ruedas. El último estudio referente a la evaluación de la temperatura de la piel en usuarios de sillas de ruedas en ejercicio, reportó diferencias significativas entre la temperatura de la piel antes del test y 10 minutos después del test de propulsión de silla de ruedas, en 12 ROIs; y entre el post-test y 10 minutos después del test en la mayoría de las ROIs. Estas diferencias se vieron atenuadas cuando se compararon las asimetrías antes y después del test. La temperatura de la piel tendió a disminuir inmediatamente después completar el ejercicio, e incrementar significativamente 10 minutos después. El análisis de las asimetrías vs dolor de hombro reveló relaciones significativas negativas en 5 de las 26 ROIs. No se encontraron correlaciones significativas entre las variables de propulsión y el cuestionario de dolor de hombro. Todas las variables cinemáticas correlacionaron significativamente con las asimetrías en múltiples ROIs. Estos resultados indican que los deportistas en sillas de ruedas exhiben una capacidad similar de producir calor que los deportistas sin discapacidad; no obstante, su patrón térmico es más característico de ejercicios prolongados que de esfuerzos breves. Este trabajo contribuye al conocimiento de la termorregulación en usuarios de sillas de ruedas durante el ejercicio, y aporta información relevante para programas deportivos y de rehabilitación. ABSTRACT Individuals who use wheelchairs as their main means of mobility have a high incidence (73%) of shoulder pain (SP) owing to overuse and repetitive propulsion movement. There are numerous diagnostic methods for the detection of shoulder pathologies, however the literature claims that a noninvasive accurate test to properly assess shoulder pain would be necessary, and suggests thermography as a suitable technique for joint pain evaluation. Infrared thermography (IRT) provides information about physiological processes by studying the skin temperature (Tsk) distributions. Due to the high correlation of skin temperature between both sides of the body, thermal asymmetries between contralateral flanks are an indicator of underlying pathologies or physical dysfunctions. The reliability of infrared thermography has been studied in healthy subjects but there are no studies that have analyzed the reliability of IRT in wheelchair users (WCUs). The special characteristics of people with disabilities (sweating and thermoregulation problems, or blood distribution) make it necessary to study the factors affecting the application of IRT in WCUs. Discrepant reports exist on the benefits of, or damage resulting from, physical exercise and the relationship to shoulder overuse injuries in WCUs. Recent findings have found that overhead sports increase the risk of rotator cuff tears in wheelchair patients with paraplegia. Since there is no agreement in the literature, the thermographic profile of wheelchair athletes and nonathletes and its relation with shoulder pain should also be analysed. Infrared thermographic studies during exercise have been carried out only with able-bodied population at present. The understanding of the thermographic response to wheelchair exercise in relation to shoulder pain will offer an insight into the development of shoulder pain, which is necessary for appropriate interventions. The first study presented in this thesis demonstrates that the reliability of IRT in WCUs varies depending on the areas of the body that are analyzed. Moreover, it corroborates that IRT is a noninvasive and noncontact technique that allows the measurement of Tsk, which will allow for advances to be made in research concerned with WCUs. The second study provides a thermal profile of WCUs. Nonathletic subjects presented higher side-to-side skin temperature differences (ΔTsk) than athletes, and both had greater ΔTsk than the able-bodied results that have been published in the literature. Nonathletes also revealed larger Wheelchair Users Shoulder Pain Index (WUSPI) score than athletes. The shoulder region of interest (ROI) was the area with the highest ΔTsk of the regions measured. The analysis of the athletes’ Tsk showed that some ROIs are related to shoulder pain. These findings help to understand the thermal map in WCUs. Finally, the third study evaluated the thermal response of WCUs in exercise. There were significant differences in Tsk between the pre-test and the post-10 min in 12 ROIs, and between the post-test and the post-10 in most of the ROIs. These differences were attenuated when the ΔTsk was compared before and after exercise. Skin temperature tended to initially decrease immediately after the test, followed by a significant increase at 10 minutes after completing the exercise. The ΔTsk versus shoulder pain analysis yielded significant inverse relationships in 5 of the 26 ROIs. No significant correlations between propulsion variables and the results of the WUSPI questionnaire were found. All kinematic variables were significantly correlated with the temperature asymmetries in multiple ROIs. These results present indications that high performance wheelchair athletes exhibit similar capacity of heat production to able-bodied population; however, they presented a thermal pattern more characteristic of a prolonged exercise rather than brief exercise. This work contributes to improve the understanding about temperature changes in wheelchair athletes during exercise and provides implications to the sports and rehabilitation programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The scientific objectives, design, and implementation of the Optical, Spectroscopic, and Infrared Remote Imaging System (OSIRIS) for the International Rosetta Mission are described. The instrument comprises two camera systems with a common electronics box. A narrow angle camera will provide high resolution images of the structure and morphology of the nucleus of a comet. A wide angle camera with high straylight rejection and dynamic range will be used to investigate the innermost coma and the emission process at the surface of the comet. An infrared imaging system, which dramatically enhances the scientific return has been included in the narrow angle camera at little extra cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infrared thermography (IRT) is a safe and non-invasive tool used for examining physiological functions based on skin temperature (Tsk) control. Thermograms from 25 anterior cruciate ligament (ACL) surgically operated patients (2 female, 23 male) were taken with a FLIR infrared camera according to the protocol established by the International Academy of Clinical Thermology (IACT). This work consists of 4 studies. Studies 1 and 3 were related to establish the probable thermal difference among different moments of an ACL rupture after surgery: before starting the rehabilitation (P0), at the end of rehabilitation (P1) and 18 months from the end of rehabilitation (P2). For this purpose, on the other hand, studies 2 and 4 were related to establish the skin thermal difference (Tsk) between the injured and the non-injured leg in P0, P1 and P2. Results of the first study showed significant temperature increases in the posterior thigh area between P0 and P1 probably due to a compensatory mechanism. According to this, we can conclude that temperature of the posterior area of the injured and noninjured leg has increased from the first to the last day of the rehabilitation process. In the second study we found significant temperature differences between the injured and non-injured leg in both stages of rehabilitation (p<.01). On the one hand, the temperature of the injured leg is higher in the anterior view and the temperature of the non-injured leg is higher in the posterior view. By the time the patients had recovered from the reconstruction, thermal imbalances should have not been shown between symmetrical parts, but differences seemed to be still latent.. Study 3 shows that temperatures seem to be higher after a year and a half (P2) than in P1. Study 4 shows how thermal values 18 months later seemed to be normalized between both legs. No significant differences were found between the injured leg and the noninjured leg after one year and a half of the rehabilitation process. Considering results from Study 3 and 4 we can conclude that patients seemed to have recovered from a thermal point of view. The temperature in P2 was higher but symmetrical. RESUMEN La termografía infrarroja (IRT) es una herramienta segura y no invasiva utilizada para examinar funciones fisiológicas que se basan en el control de temperatura de la piel (Tsk). Termogramas de 25 pacientes intervenidos quirúrgicamente del ligamento cruzado anterior (LCA) (2 mujeres, 23 hombres) fueron tomadas con una cámara de infrarrojos FLIR de acuerdo con el protocolo establecido por la Academia Internacional de Termología Clínica (IACT). Este trabajo consiste en 4 estudios. Los estudios 1 y 3 describen la diferencia térmica entre los diferentes momentos tras la operación del ligamento cruzado anterior: antes de comenzar la rehabilitación (P0), al final de la rehabilitación (P1) y 18 meses tras finalizar la rehabilitación (P2). Por otra parte, los estudios 2 y 4 describen la diferencia de temperatura de la piel (Tsk) entre la pierna lesionada y la pierna no lesionada en P0, P1 y P2. Los resultados del primer estudio mostraron aumentos significativos de temperatura en la zona posterior de los muslos entre P0 y P1, probablemente debido a un mecanismo de compensación. De acuerdo con esto, se puede concluir que la temperatura de la zona posterior de la pierna lesionada y no lesionada se ha incrementado desde el primero hasta el último día del proceso de rehabilitación. En el segundo estudio se encontraron diferencias significativas de temperatura entre la pierna lesionada y no lesionada en ambas etapas de la rehabilitación (p<.01). Por un lado, la temperatura de la pierna lesionada es mayor en la vista anterior. Por otro lado, la temperatura de la pierna no lesionada es mayor en la vista posterior. Una vez que los pacientes se han recuperado de todo el proceso, no deberían existir desequilibrios térmicos entre partes simétricas del cuerpo, pero las diferencias todavía estaban latentes. El tercer estudio muestra que la temperatura es más alta en P2 que en P1. El cuarto estudio muestra cómo los valores térmicos entre ambas piernas en P2 se han normalizado entre ambas piernas. No se encontraron diferencias significativas entre la pierna lesionada y la pierna no lesionada después de 18 meses tras el proceso de rehabilitación. Considerando los resultados del studio 3 y 4, podemos concluir que se ha llegado a la recuperación total desde un punto de vista térmico. La temperatura es más elevada en P2 pero simétrica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two-dimensional infrared spectra of peptides are introduced that are the direct analogues of two- and three-pulse multiple quantum NMR. Phase matching and heterodyning are used to isolate the phase and amplitudes of the electric fields of vibrational photon echoes as a function of multiple pulse delays. Structural information is made available on the time scale of a few picoseconds. Line narrowed spectra of acyl-proline-NH2 and cross peaks implying the coupling between its amide-I modes are obtained, as are the phases of the various contributions to the signals. Solvent-sensitive structural differences are seen for the dipeptide. The methods show great promise to measure structure changes in biology on a wide range of time scales.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structure of the tetrameric K+ channel from Streptomyces lividans in a lipid bilayer environment was studied by polarized attenuated total reflection Fourier transform infrared spectroscopy. The channel displays approximately 43% α-helical and 25% β-sheet content. In addition, H/D exchange experiments show that only 43% of the backbone amide protons are exchangeable with solvent. On average, the α-helices are tilted 33° normal to the membrane surface. The results are discussed in relationship to the lactose permease of Escherichia coli, a membrane transport protein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The correlation functions of the fluctuations of vibrational frequencies of azide ions and carbon monoxide in proteins are determined directly from stimulated photon echoes generated with femtosecond infrared pulses. The asymmetric stretching vibration of azide bound to carbonic anhydrase II exhibits a pronounced evolution of its vibrational frequency distribution on the time scale of a few picoseconds, which is attributed to modifications of the ligand structure through interactions with the nearby Thr-199. When azide is bound in hemoglobin, a more complex evolution of the protein structure is required to interchange the different ligand configurations, as evidenced by the much slower relaxation of the frequency distribution in this case. The time evolution of the distribution of frequencies of carbon monoxide bound in hemoglobin occurs on the ≈10-ps time scale and is very nonexponential. The correlation functions of the frequency fluctuations determine the evolution of the protein structure local to the probe and the extent to which the probe can navigate those parts of the energy landscape where the structural configurations are able to modify the local potential energy function of the probe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Isolated immature maize (Zea mays L.) embryos have been shown to acquire tolerance to rapid drying between 22 and 25 d after pollination (DAP) and to slow drying from 18 DAP onward. To investigate adaptations in protein profile in association with the acquisition of desiccation tolerance in isolated, immature maize embryos, we applied in situ Fourier transform infrared microspectroscopy. In fresh, viable, 20- and 25-DAP embryo axes, the shapes of the different amide-I bands were identical, and this was maintained after flash drying. On rapid drying, the 20-DAP axes had a reduced relative proportion of α-helical protein structure and lost viability. Rapidly dried 25-DAP embryos germinated (74%) and had a protein profile similar to the fresh control axes. On slow drying, the α-helical contribution in both the 20- and 25-DAP embryo axes increased compared with that in the fresh control axes, and survival of desiccation was high. The protein profile in dry, mature axes resembled that after slow drying of the immature axes. Rapid drying resulted in an almost complete loss of membrane integrity in the 20-DAP embryo axes and much less so in the 25-DAP axes. After slow drying, low plasma membrane permeability ensued in both the 20- and 25-DAP axes. We conclude that slow drying of excised, immature embryos leads to an increased proportion of α-helical protein structures in their axes, which coincides with additional tolerance of desiccation stress.