968 resultados para IEEE 802.11i


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Free-space optical interconnects (FSOIs), made up of dense arrays of vertical-cavity surface-emitting lasers, photodetectors and microlenses can be used for implementing high-speed and high-density communication links, and hence replace the inferior electrical interconnects. A major concern in the design of FSOIs is minimization of the optical channel cross talk arising from laser beam diffraction. In this article we introduce modifications to the mode expansion method of Tanaka et al. [IEEE Trans. Microwave Theory Tech. MTT-20, 749 (1972)] to make it an efficient tool for modelling and design of FSOIs in the presence of diffraction. We demonstrate that our modified mode expansion method has accuracy similar to the exact solution of the Huygens-Kirchhoff diffraction integral in cases of both weak and strong beam clipping, and that it is much more accurate than the existing approximations. The strength of the method is twofold: first, it is applicable in the region of pronounced diffraction (strong beam clipping) where all other approximations fail and, second, unlike the exact-solution method, it can be efficiently used for modelling diffraction on multiple apertures. These features make the mode expansion method useful for design and optimization of free-space architectures containing multiple optical elements inclusive of optical interconnects and optical clock distribution systems. (C) 2003 Optical Society of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Concurrent programs are hard to test due to the inherent nondeterminism. This paper presents a method and tool support for testing concurrent Java components. Too[ support is offered through ConAn (Concurrency Analyser), a too] for generating drivers for unit testing Java classes that are used in a multithreaded context. To obtain adequate controllability over the interactions between Java threads, the generated driver contains threads that are synchronized by a clock. The driver automatically executes the calls in the test sequence in the prescribed order and compares the outputs against the expected outputs specified in the test sequence. The method and tool are illustrated in detail on an asymmetric producer-consumer monitor. Their application to testing over 20 concurrent components, a number of which are sourced from industry and were found to contain faults, is presented and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contrata????o de servi??os t??cnicos profissionais especializados de treinamento e aperfei??oamento de pessoal para a realiza????o de Oficina, Sob Medida, de planejamento estrat??gico para elabora????o do Plano de A????o 2013 da Secretaria Nacional Assist??ncia Social (SNAS) do Minist??rio do Desenvolvimento Social e Combate ?? Fome (MDS)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Textos apresentados no XI Seminário Capixaba de Educação Inclusiva, realizado no município de Vitória, em setembro de 2008.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A rinometria acústica permite aferir a geometria nasal de forma objetiva e não-invasiva. OBJETIVO: O presente estudo teve por finalidade determinar os volumes de segmentos específicos da cavidade nasal, incluindo a nasofaringe, de adultos sadios por rinometria acústica. Forma de Estudo: Clínico prospectivo. CASUÍSTICA E MÉTODO: Foram analisados 30 voluntários sem evidências de obstrução nasal com idade entre 18 e 30 anos, sendo 14 homens e 16 mulheres. Os volumes foram medidos nos segmentos correspondentes à região da válvula nasal (V1), cornetos (V2) e nasofaringe (V3), antes e após a aplicação tópica de vasoconstritor nasal. RESULTADOS: Os volumes médios aferidos em 60 cavidades, antes da vasoconstrição nasal foram os seguintes: 1,81±0,35cm³ (V1), 4,02±1,41cm³ (V2) e 17,52±4,44cm3 (V3) no grupo masculino, e, 1,58±0,25cm³ (V1), 3,94±1,03cm³ (V2) e 17,80±2,73cm³ (V3) no grupo feminino. As diferenças entre os sexos foram significantes apenas para V1 (p<0,05). Após a vasoconstrição nasal, os volumes de todos os segmentos analisados foram significantemente maiores (p<0,05), sendo as diferenças entre os sexos significantes para V1 e V2. CONCLUSÃO: Os volumes dos três segmentos da cavidade nasal determinados em adultos sem evidências de obstrução nasal podem ser utilizados como valores de referência para outros estudos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The success of the digital game industry is spawning several undergraduate degrees aiming at the training of digital game developers. Building adequate new courses curricula is not a trivial task and demands a profound analysis of the scientific areas to introduce as well as the dependencies throughout the entire degree. Another important aspect of every academic educational plan are the satellite projects that promote entrepreneurship and provide practical professional experiences to students. This paper presents the main guidelines adopted in the creation of the first digital game development undergraduate degree created in Portugal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Laparoscopy is a surgical procedure on which operations in the abdomen are performed through small incisions using several specialized instruments. The laparoscopic surgery success greatly depends on surgeon skills and training. To achieve these technical high-standards, different apprenticeship methods have been developed, many based on in vivo training, an approach that involves high costs and complex setup procedures. This paper explores Virtual Reality (VR) simulation as an alternative for novice surgeons training. Even though several simulators are available on the market claiming successful training experiences, their use is extremely limited due to the economic costs involved. In this work, we present a low-cost laparoscopy simulator able to monitor and assist the trainee’s surgical movements. The developed prototype consists of a set of inexpensive sensors, namely an accelerometer, a gyroscope, a magnetometer and a flex sensor, attached to specific laparoscopic instruments. Our approach allows repeated assisted training of an exercise, without time constraints or additional costs, since no human artificial model is needed. A case study of our simulator applied to instrument manipulation practice (hand-eye coordination) is also presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

COORDINSPECTOR is a Software Tool aiming at extracting the coordination layer of a software system. Such a reverse engineering process provides a clear view of the actually invoked services as well as the logic behind such invocations. The analysis process is based on program slicing techniques and the generation of, System Dependence Graphs and Coordination Dependence Graphs. The tool analyzes Common Intermediate Language (CIL), the native language of the Microsoft .Net Framework, thus making suitable for processing systems developed in any .Net Framework compilable language. COORDINSPECTOR generates graphical representations of the coordination layer together with business process orchestrations specified in WSBPEL 2.0

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The interoperability of IP video equipment is a critical problem for surveillance systems and other video application developers. ONVIF is one of the two specifications addressing the standardization of networked devices interface, and it is based on SOAP. This paper addresses the development of an ONVIF library to develop clients of video cameras. We address the choice of a web services toolkit, and how to use the selected toolkit to develop a basic library. From that, we discuss the implementation of features that ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A unique neural electrode design is proposed with 3 mm long shafts made from an aluminum-based substrate. The electrode is composed by 100 individualized shafts in a 10 × 10 matrix, in which each aluminum shafts are precisely machined via dicing-saw cutting programs. The result is a bulk structure of aluminum with 65 ° angle sharp tips. Each electrode tip is covered by an iridium oxide thin film layer (ionic transducer) via pulsed sputtering, that provides a stable and a reversible behavior for recording/stimulation purposes, a 40 mC/cm2 charge capacity and a 145 Ω impedance in a wide frequency range of interest (10 Hz-100 kHz). Because of the non-biocompatibility issue that characterizes aluminum, an anodization process is performed that forms an aluminum oxide layer around the aluminum substrate. The result is a passivation layer fully biocompatible that furthermore, enhances the mechanical properties by increasing the robustness of the electrode. For a successful electrode insertion, a 1.1 N load is required. The resultant electrode is a feasible alternative to silicon-based electrode solutions, avoiding the complexity of its fabrication methods and limitations, and increasing the electrode performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the number of elderly people increasing tremendously worldwide, comes the need for effective methods to maintain or improve older adults' cognitive performance. Using continuous neurofeedback, through the use of EEG techniques, people can learn how to train and alter their brain electrical activity. A software platform that puts together the proposed rehabilitation methodology has been developed: a digital game protocol that supports neurofeedback training of alpha and theta rhythms, by reading the EEG activity and presenting it back to the subject, interleaved with neurocognitive tasks such as n-Back and Corsi Block-Tapping. This tool will be used as a potential rehabilitative platform for age-related memory impairments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several studies suggest that computer-mediated communication can lead to decreases in group effectiveness and reduce satisfaction levels in terms of trust and comfort of its users. Supported by an experiment, where the emotional or affective aspects of communication were tested with the experimentation of two architectures, Direct Communication Architecture (DCA) and the Virtual Communication Architecture (VCA) this paper validates the thesis that, from the users’ perspective, there is no opposition to the acceptance of virtual environments and interfaces for communication, and that these environments are able to cope with the reconfiguration dynamics requirements of virtual teams or client-server relations in a virtual enterprise operation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents Palco, a prototype system specifically designed for the production of 3D cartoon animations. The system addresses the specific problems of producing cartoon animations, where the main obj ective is not to reproduce realistic movements, but rather animate cartoon characters with predefined and characteristic body movements and facial expressions. The techniques employed in Palco are simple and easy to use, not requiring any invasive or complicated motion capture system, as both body motion and facial expression of actors are captured simultaneously, using an infrared motion detection sensor, a regular camera and a pair of electronically instrumented gloves. The animation process is completely actor-driven, with the actor controlling the character movements, gestures, facial expression and voice, all in realtime. The actor controlled cartoonification of the captured facial and body motion is a key functionality of Palco, and one that makes it specifically suited for the production of cartoon animations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The success of the osseointegration concept and the Brånemark protocol is highly associated to the accuracy in the production of an implant-supported prosthesis. One of most critical steps for long-term success of these prosthesis is the accuracy obtained during the impression procedure, which is affected by factors such as the impression material, implant position, angulation and depth. This paper investigates the feasibility of 3D electromagnetic motion tracking systems as an acquisition method for modeling full-arch implant-supported prosthesis. To this extent, we propose an implant acquisition method at the patient mouth and a calibration procedure, based on a 3D electromagnetic tracker that obtains combined measurements of implant’s position and angulation, eliminating the use of any impression material. Three calibration algorithms (namely linear interpolation, higher-order polynomial and Hardy multiquadric) were tested to compensate for the electromagnetic tracker distortions introduced by the presence of nearby metals. Moreover, implants from different suppliers were also tested to study its impact on tracking accuracy. The calibration methodology and the algorithms employed proved to implement a suitable strategy for the evaluation of novel dental impression techniques. However, in the particular case of the evaluated electromagnetic tracking system, the order of magnitude of the obtained errors invalidates its use for the full-arch modeling of implant-supported prosthesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Laparoscopic surgery (LS) has revolutionized traditional surgical techniques introducing minimally invasive procedures for diagnosis and local therapies. LSs have undeniable advantages, such as small patient incisions, reduced postoperative pain and faster recovery. On the other hand, restricted vision of the anatomical target, difficult handling of the surgical instruments, restricted mobility inside the human body, need of dexterity to hand-eye coordination and inadequate and non-ergonomic surgical instruments may restrict LS only to more specialized surgeons. To overcome the referred limitations, this work presents a new robotic surgical handheld system – the EndoRobot. The EndoRobot was designed to be used in clinical practice or even as a surgical simulator. It integrates an electromechanical system with 3 degrees of freedom. Each degree can be manipulated independently and combined with different levels of sensitivity allowing fast and slow movements. As other features, the EndoRobot has battery power or external power supply, enables the use of bipolar radiofrequency to prevent bleeding while cutting and allows plug-and-play of the laparoscopic forceps for rapid exchange. As a surgical simulator, the system was also instrumented to measure and transmit, in real time, its position and orientation for a training software able to monitor and assist the trainee’s surgical movements.