954 resultados para ICC-profiler
Resumo:
Background: Current guidelines underline the limitations of existing instruments to assess fitness to drive and the poor adaptability of batteries of neuropsychological tests in primary care settings. Aims: To provide a free, reliable, transparent computer based instrument capable of detecting effects of age or drugs on visual processing and cognitive functions. Methods: Relying on systematic reviews of neuropsychological tests and driving performances, we conceived four new computed tasks measuring: visual processing (Task1), movement attention shift (Task2), executive response, alerting and orientation gain (Task3), and spatial memory (Task4). We then planned five studies to test MedDrive's reliability and validity. Study-1 defined instructions and learning functions collecting data from 105 senior drivers attending an automobile club course. Study-2 assessed concurrent validity for detecting minor cognitive impairment (MCI) against useful field of view (UFOV) on 120 new senior drivers. Study-3 collected data from 200 healthy drivers aged 20-90 to model age related normal cognitive decline. Study-4 measured MedDrive's reliability having 21 healthy volunteers repeat tests five times. Study-5 tested MedDrive's responsiveness to alcohol in a randomised, double-blinded, placebo, crossover, dose-response validation trial including 20 young healthy volunteers. Results: Instructions were well understood and accepted by all senior drivers. Measures of visual processing (Task1) showed better performances than the UFOV in detecting MCI (ROC 0.770 vs. 0.620; p=0.048). MedDrive was capable of explaining 43.4% of changes occurring with natural cognitive decline. In young healthy drivers, learning effects became negligible from the third session onwards for all tasks except for dual tasking (ICC=0.769). All measures except alerting and orientation gain were affected by blood alcohol concentrations. Finally, MedDrive was able to explain 29.3% of potential causes of swerving on the driving simulator. Discussion and conclusions: MedDrive reveals improved performances compared to existing computed neuropsychological tasks. It shows promising results both for clinical and research purposes.
Resumo:
The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.
Resumo:
BACKGROUND: The Foot and Ankle Ability Measure (FAAM) is a self reported questionnaire for patients with foot and ankle disorders available in English, German, and Persian. This study plans to translate the FAAM from English to French (FAAM-F) and assess the validity and reliability of this new version.METHODS: The FAAM-F Activities of Daily Living (ADL) and sports subscales were completed by 105 French-speaking patients (average age 50.5 years) presenting various chronic foot and ankle disorders. Convergent and divergent validity was assessed by Pearson's correlation coefficients between the FAAM-F subscales and the SF-36 scales: Physical Functioning (PF), Physical Component Summary (PCS), Mental Health (MH) and Mental Component Summary (MCS). Internal consistency was calculated by Cronbach's Alpha (CA). To assess test re-test reliability, 22 patients filled out the questionnaire a second time to estimate minimal detectable changes (MDC) and intraclass correlation coefficients (ICC).RESULTS: Correlations for FAAM-F ADL subscale were 0.85 with PF, 0.81 with PCS, 0.26 with MH, 0.37 with MCS. Correlations for FAAM-F Sports subscale were 0.72 with PF, 0.72 with PCS, 0.21 with MH, 0.29 with MCS. CA estimates were 0.97 for both subscales. Respectively for the ADL and Sports subscales, ICC were 0.97 and 0.94, errors for a single measure were 8 and 10 points at 95% confidence and the MDC values at 95% confidence were 7 and 18 points.CONCLUSION: The FAAM-F is valid and reliable for the self-assessment of physical function in French-speaking patients with a wide range of chronic foot and ankle disorders.
Resumo:
BACKGROUND: CODIS-STRs in Native Mexican groups have rarely been analysed for human identification and anthropological purposes. AIM:To analyse the genetic relationships and population structure among three Native Mexican groups from Mesoamerica.SUBJECTS AND METHODS: 531 unrelated Native individuals from Mexico were PCR-typed for 15 and 9 autosomal STRs (Identifiler™ and Profiler™ kits, respectively), including five population samples: Purépechas (Mountain, Valley and Lake), Triquis and Yucatec Mayas. Previously published STR data were included in the analyses. RESULTS:Allele frequencies and statistical parameters of forensic importance were estimated by population. The majority of Native groups were not differentiated pairwise, excepting Triquis and Purépechas, which was attributable to their relative geographic and cultural isolation. Although Mayas, Triquis and Purépechas-Mountain presented the highest number of private alleles, suggesting recurrent gene flow, the elevated differentiation of Triquis indicates a different origin of this gene flow. Interestingly, Huastecos and Mayas were not differentiated, which is in agreement with the archaeological hypothesis that Huastecos represent an ancestral Maya group. Interpopulation variability was greater in Natives than in Mestizos, both significant.CONCLUSION: Although results suggest that European admixture has increased the similarity between Native Mexican groups, the differentiation and inconsistent clustering by language or geography stresses the importance of serial founder effect and/or genetic drift in showing their present genetic relationships.
Resumo:
Pavement profile or smoothness has been identified nationally as a good measure of highway user satisfaction. This has led highway engineers to measure profiles of both operating and new highways. Operational highway profiles are often measured with high-speed inertial profilers. New highway profiles are usually measured with profilographs in order to establish incentives or disincentives for pavement construction. In most cases, these two processes do not measure the same value from the “cradle to grave” life of pavements. In an attempt to correct the inconsistency between measuring techniques, lightweight profilers intended to produce values to be used for construction acceptance are being made that measure the same profile as high-speed inertial profilers. Currently, two profiler systems have been identified that can measure pavement profile during construction. This research has produced a field evaluation of the two systems. The profilers evaluated in this study are able to detect roughness in the final profile, including localized roughness and roughness at joints. Dowel basket ripple is a significant source of pavement surface roughness. The profilers evaluated in this study are able to detect dowel basket ripple with enough clarity to warn the paving crew. String-line disturbances degrade smoothness. The profilers evaluated in this study are able to detect some string-line disturbances during paving operations. The profilers evaluated in this study are not currently able to produce the same absolute International Roughness Index (IRI) values on the plastic concrete that can be measured by inertial profilers on the hardened concrete. Construction application guidelines are provided.
Resumo:
Expressions relating spectral efficiency, power and Doppler spectrum are derived for low-power Rayleighfaded wireless channels with proper complex signaling. Noside information on the state of the channel is assumed at the receiver. Rather, periodic reference signals are postulated inaccordance with the functioning of most wireless systems. In contrast with most previous studies, which relied on block-fading channel models, a continuous-fading model is adopted. This embeds the Doppler spectrum directly in thederived expressions thereby imbuing them with practical significance.
Resumo:
For single-user MIMO communication with uncoded and coded QAM signals, we propose bit and power loading schemes that rely only on channel distribution information at the transmitter. To that end, we develop the relationship between the average bit error probability at the output of a ZF linear receiver and the bit rates and powers allocated at the transmitter. This relationship, and the fact that a ZF receiver decouples the MIMO parallel channels, allow leveraging bit loading algorithms already existing in the literature. We solve dual bit rate maximization and power minimization problems and present performance resultsthat illustrate the gains of the proposed scheme with respect toa non-optimized transmission.
Resumo:
Objective: To test the efficacy of teaching motivational interviewing (MI) to medical students. Methods: Thirteen 4th year medical students volunteered to participate. Seven days before and 7 days after an 8-hour interactive training MI workshop, each student performed a videorecorded interview with two standardized patients: a 60 year old alcohol dependent woman and a 50 year old cigarette smoking man. Students' counseling skills were coded by two blinded clinicians using the Motivational Interviewing Treatment Integrity 3.0 (MITI). Inter-rater reliability was calculated for all interviews and a test-retest was completed in a sub-sample of 10 consecutive interviews three days apart. Difference between MITI scores before and after training were calculated and tested using non-parametric tests. Effect size was approximated by calculating the probability that posttest scores are greater than pretest scores (P*=P(Pre<Post)+1/2P(Pre=Post)), P*>1/2 indicating greater scores in posttest, P*=1/2 no effect, and P*<1/2 smaller scores in posttest. Results: Median differences between MITI scores before and after MI training indicated a general progression in MI skills: MI spirit global score (median difference=1.5, Inter quartile range=1.5, p<0.001, P*=0.90); Empathy global score (med diff=1, IQR=0.5, p<0.001, P*=0.85); Percentage of MI adherent skills (med diff=36.6, IQR=50.5, p<0.001, P*=0.85); Percentage of open questions (med diff=18.6, IQR=21.6, p<0.001, P*=0.96); reflections/ questions ratio (med diff=0.2, IQR=0.4, p<0.001, P*=0.81). Only Direction global score and the percentage of complex reflections were not significantly improved (med diff=0, IQR=1, p=0.53, P*=0.44, and med diff=4.3, IQR=24.8, p=0.48, P*=0.62, respectively). Inter-rater reliability indicated weighted kappa ranged between 0.14 for Direction to 0.51 for Collaboration and ICC ranged between 0.28 for Simple reflection to 0.95 for Closed question. Test-retests indicated weighted kappa ranged between 0.27 for Direction to 0.80 for Empathy and ICC ranged between 0.87 for Complex reflection to 0.98 for Closed question. Conclusion: This pilot study indicated that an 8-hour training in MI for voluntary 4th year medical students resulted in significant improvement of MI skills. Larger sample of unselected medical students should be studied to generalize the benefit of MI training to medical students. Interrater reliability and test-retests suggested that coders' training should be intensified.
Resumo:
This study aimed to derive an index quantifying the state of alteration of cadavers by quantifying the presence of gas in the body using postmortem multidetector computed tomography (MDCT) imaging, and to validate the index by defining its sensitivity and specificity. The RA (radiological alteration)-index was derived from postmortem MDCT data from 118 nontraumatically deceased people. To validate the index, 100 additional scanned bodies (50 % traumatically deceased) were retrospectively examined by two independent observers. Presence of gas at 82 sites was assessed by a radiologist, whereas a forensic pathologist only investigated the seven sites used for the RA-index. The RA-index was highly correlated to the overall presence of gas in all 82 sites (R(2) = 0.98 in the derivation set and 0.85 in the validation set). Semiquantitative evaluation of gas presence in each site showed moderate reliability (Cohen's kappa range, 0.41-0.78); nevertheless, the overall RA-index was very reliable (ICC(2,1) = 0.95; 95 % CI 0.92-0.96). Examiner using the RA-index detected heart cavities full of gas with a sensitivity of 100 % (95 % CI 51.7-100) and a specificity of 98.8 % (92.6-99.9). We conclude that determining the presence of gas at seven sites is a valid means to measure the distribution of gas due to cadaveric alteration in the entire body. The RA-index is rapid, easy-to-use, and reliable for nonexperienced users, and it is a valid method to suspect the normal presence of gas from cadaveric alteration. MDCT can be used to screen for gas embolism and to give indications for gas composition analysis (gas chromatography).
Resumo:
Este estudo objetivou adaptar culturalmente e analisar as propriedades psicométricas da versão brasileira da Underwood's Daily Spiritual Experience Scale (DSES). A adaptação seguiu as etapas internacionalmente recomendadas e a versão adaptada manteve equivalência com a original, após ajustes na redação de cinco itens. Na aplicação a 179 pacientes médico-cirúrgicos mostrou evidências de consistência interna (alfa de Cronbach=0,91), estabilidade temporal (ICC=0,94 no teste e reteste) e validade de construto convergente, na correlação com a subescala Religiosidade Intrínseca do instrumento DUREL (r=0,56; p<0,001). A análise fatorial exploratória extraiu três componentes, explicando 60,5% da variância do total. A versão brasileira da DSES apresenta evidências de confiabilidade e validade junto a pacientes hospitalizados. São necessários mais estudos para confirmar a sua composição fatorial e testar a sua aplicabilidade em diferentes populações.
Resumo:
Estudo exploratório-descritivo, desenvolvido com o objetivo de construir afirmativas de diagnósticos e intervenções de enfermagem para pacientes portadores de insuficiência cardíaca congestiva. Para tanto, foram identificados na CIPE® 53 termos do eixo foco, que nortearam a construção dessas afirmativas utilizando as diretrizes do Conselho Internacional de Enfermeiros e a ISO 18.104. Foram construídas 92 afirmativas de diagnósticos de enfermagem, que depois de normalizadas, passaram a 66 e foram separadas de acordo com o modelo fisiopatológico, assim distribuídas: 13 para taquicardia, 20 para dispneia, 19 para edema e 14 para congestão. Para essas afirmativas construíram-se 234 intervenções, levando em consideração os termos do Modelo de Sete Eixos da CIPE®, a literatura da área e a experiência clínica das autoras. Espera-se que as afirmativas de diagnósticos e intervenções de enfermagem elaboradas possam favorecer a avaliação de indivíduos portadores de ICC e a construção de um subconjunto terminológico da CIPE®.
Resumo:
When facing age-related cerebral decline, older adults are unequally affected by cognitive impairment without us knowing why. To explore underlying mechanisms and find possible solutions to maintain life-space mobility, there is a need for a standardized behavioral test that relates to behaviors in natural environments. The aim of the project described in this paper was therefore to provide a free, reliable, transparent, computer-based instrument capable of detecting age-related changes on visual processing and cortical functions for the purposes of research into human behavior in computational transportation science. After obtaining content validity, exploring psychometric properties of the developed tasks, we derived (Study 1) the scoring method for measuring cerebral decline on 106 older drivers aged ≥70 years attending a driving refresher course organized by the Swiss Automobile Association to test the instrument's validity against on-road driving performance (106 older drivers). We then validated the derived method on a new sample of 182 drivers (Study 2). We then measured the instrument's reliability having 17 healthy, young volunteers repeat all tests included in the instrument five times (Study 3) and explored the instrument's psychophysical underlying functions on 47 older drivers (Study 4). Finally, we tested the instrument's responsiveness to alcohol and effects on performance on a driving simulator in a randomized, double-blinded, placebo, crossover, dose-response, validation trial including 20 healthy, young volunteers (Study 5). The developed instrument revealed good psychometric properties related to processing speed. It was reliable (ICC = 0.853) and showed reasonable association to driving performance (R (2) = 0.053), and responded to blood alcohol concentrations of 0.5 g/L (p = 0.008). Our results suggest that MedDrive is capable of detecting age-related changes that affect processing speed. These changes nevertheless do not necessarily affect driving behavior.
Resumo:
This study evaluated the acceptability, ceiling/floor effects, and the reliability of the instrument for measuring the Impact of the Disease on the Daily Life of Patients with Valvular Disease (IDCV) when applied to 135 patients with heart failure (HF). Acceptability was evaluated by the percentage of unanswered items and by the proportion of patients who responded to all items; the ceiling/floor effects by the percentage of patients who scored in the top of 10% best and worst results of the scale, respectively. Reliability was estimated by internal consistency (Cronbach's alpha coefficient) and stability of the measure (intraclass correlation coefficient - ICC). All patients responded to all items. Ceiling/floor effects evidenced were of moderate magnitude. The Cronbach's alpha was satisfactory for the majority of the domains and ICC> 0.90 in all the domains. The IDCV proved to be an easy to understand questionnaire, with evidence of reliability in patients with HF.
Resumo:
OBJECTIVES: Kaposi's sarcoma (KS), invasive cervical carcinoma (ICC) and non-Hodgkin lymphoma (NHL) have been listed as AIDS-defining cancers (ADCs) by the Centers for Disease Control and Prevention since 1993. Despite this, HIV screening is not universally mentioned in ADC treatment guidelines. We examined screening practices at a tertiary centre serving a population where HIV seroprevalence is 0.4%. METHODS: Patients with KS, ICC, NHL and Hodgkin lymphoma (HL), treated at Lausanne University Hospital between January 2002 and July 2012, were studied retrospectively. HIV testing was considered part of the oncology work-up if performed between 90 days before and 90 days after the cancer diagnosis date. RESULTS: A total of 880 patients were examined: 10 with KS, 58 with ICC, 672 with NHL and 140 with HL. HIV testing rates were 100, 11, 60 and 59%, and HIV seroprevalence was 60, 1.7, 3.4 and 5%, respectively. Thirty-seven patients (4.2%) were HIV-positive, of whom eight (22%) were diagnosed at oncology work-up. All newly diagnosed patients had CD4 counts < 200 cells/μL and six (75%) had presented to a physician 12-236 weeks previously with conditions warranting HIV testing. CONCLUSIONS: In our institution, only patients with KS were universally screened. Screening rates for other cancers ranged from 11 to 60%. HIV seroprevalence was at least fourfold higher than the population average. As HIV-positive status impacts on cancer patient medical management, HIV screening should be included in oncology guidelines. Further, we recommend that opt-out screening should be adopted in all patients with ADCs and HL.
Resumo:
BACKGROUND: Hyperoxaluria is a major risk factor for kidney stone formation. Although urinary oxalate measurement is part of all basic stone risk assessment, there is no standardized method for this measurement. METHODS: Urine samples from 24-h urine collection covering a broad range of oxalate concentrations were aliquoted and sent, in duplicates, to six blinded international laboratories for oxalate, sodium and creatinine measurement. In a second set of experiments, ten pairs of native urine and urine spiked with 10 mg/L of oxalate were sent for oxalate measurement. Three laboratories used a commercially available oxalate oxidase kit, two laboratories used a high-performance liquid chromatography (HPLC)-based method and one laboratory used both methods. RESULTS: Intra-laboratory reliability for oxalate measurement expressed as intraclass correlation coefficient (ICC) varied between 0.808 [95% confidence interval (CI): 0.427-0.948] and 0.998 (95% CI: 0.994-1.000), with lower values for HPLC-based methods. Acidification of urine samples prior to analysis led to significantly higher oxalate concentrations. ICC for inter-laboratory reliability varied between 0.745 (95% CI: 0.468-0.890) and 0.986 (95% CI: 0.967-0.995). Recovery of the 10 mg/L oxalate-spiked samples varied between 8.7 ± 2.3 and 10.7 ± 0.5 mg/L. Overall, HPLC-based methods showed more variability compared to the oxalate oxidase kit-based methods. CONCLUSIONS: Significant variability was noted in the quantification of urinary oxalate concentration by different laboratories, which may partially explain the differences of hyperoxaluria prevalence reported in the literature. Our data stress the need for a standardization of the method of oxalate measurement.