891 resultados para Hazardous waste treatment facilities


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present paper presents the study of the decolourisation of real textile effluent by constant current electrolysis in a flow-cell using a DSAO type material. The effect of using different anode materials (Ti/Ru0.3Ti0.7O2; Ti/Ir0.3Ti0.7O2; Ti/RuxSn1-xO2, where X = 0.1, 0.2 or 0.3) on the efficiency of colour removal is discussed. Attempts to perform galvanostatic oxidation (40 and 60 mA cm(-2)) on the as-received effluent demonstrate that colour removal and total organic carbon (TOC) removal are limited. In this case the greatest degree of colour removal is achieved when anode containing 90% SnO2 is used. If the conductivity of the effluent is increased by adding NaCl (0.1 mol L-1) appreciable colour/TOC removal is observed. The efficiencies of colour and TOC removal are discussed in terms of the energy per order (E-EO/kWhm(-3) order(-1)) and energy consumption (E-C/kW h kg(-1) TOC), respectively. Finally, the extent of colour removal is compared to consent levels presented in the literature. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Between 75% and 90% of the waste produced by health-care providers no risk or is "general" health-care waste, comparable to domestic waste. The remaining 10-25% of health-care waste is regarded as hazardous due to one or more of the following characteristics: it may contain infectious agents, sharps, toxic or hazardous chemicals or it may be radioactive. Infectious health-care waste, particularly sharps, has been responsible for most of the accidents reported in the literature. In this work the preliminary risks analysis (PRA) technique was used to evaluate practices in the handling of infectious health-care waste. Currently the PRA technique is being used to identify and to evaluate the potential for hazard of the activities, products, and services from facilities and industries. The system studied was a health-care establishment which has handling practices for infectious waste. Thirty-six procedures related to segregation, containment, internal collection, and storage operation were analyzed. The severity of the consequences of the failure (risk) that can occur from careless management of infectious health-care waste was classified into four categories: negligible, marginal, critical, and catastrophic. The results obtained in this study showed that events with critics consequences, about 80%, may occur during the implementation of the containment operation, suggesting the need to prioritize this operation. As a result of the methodology applied in this work, a flowchart the risk series was also obtained. In the flowchart the events that can occur as a consequence of a improper handling of infectious health-care waste, which can cause critical risks such as injuries from sharps and contamination (infection) from pathogenic microorganisms, are shown.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Produced water in oil fields is one of the main sources of wastewater generated in the industry. It contains several organic compounds, such as benzene, toluene, ethyl benzene and xylene (BTEX), whose disposal is regulated by law. The aim of this study is to investigate a treatment of produced water integrating two processes, i.e., induced air flotation (IAF) and photo-Fenton. The experiments were conducted in a column flotation and annular lamp reactor for flotation and photodegradation steps, respectively. The first order kinetic constant of IAF for the wastewater studied was determined to be 0.1765 min(-1) for the surfactant EO 7. Degradation efficiencies of organic loading were assessed using factorial planning. Statistical data analysis shows that H2O2 concentration is a determining factor in process efficiency. Degradations above 90% were reached in all cases after 90 min of reaction, attaining 100% mineralization in the optimized concentrations of Fenton reagents. Process integration was adequate with 100% organic load removal in 20 min. The results of the integration of the IAF with the photo-Fenton allowed to meet the effluent limits established by Brazilian legislation for disposal. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work demonstrates that the plasma - induced combustion of intermediate to low-level radioactive waste is a suitable method for volume reduction and stabilization. Weaknesses of existing facilities can be overcome with novel developments. Plasma treatment of LILW has a high economical advantage by volume reduction for storage in final repositories.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Waste management represents an important issue in our society and Waste-to-Energy incineration plants have been playing a significant role in the last decades, showing an increased importance in Europe. One of the main issues posed by waste combustion is the generation of air contaminants. Particular concern is present about acid gases, mainly hydrogen chloride and sulfur oxides, due to their potential impact on the environment and on human health. Therefore, in the present study the main available technological options for flue gas treatment were analyzed, focusing on dry treatment systems, which are increasingly applied in Municipal Solid Wastes (MSW) incinerators. An operational model was proposed to describe and optimize acid gas removal process. It was applied to an existing MSW incineration plant, where acid gases are neutralized in a two-stage dry treatment system. This process is based on the injection of powdered calcium hydroxide and sodium bicarbonate in reactors followed by fabric filters. HCl and SO2 conversions were expressed as a function of reactants flow rates, calculating model parameters from literature and plant data. The implementation in a software for process simulation allowed the identification of optimal operating conditions, taking into account the reactant feed rates, the amount of solid products and the recycle of the sorbent. Alternative configurations of the reference plant were also assessed. The applicability of the operational model was extended developing also a fundamental approach to the issue. A predictive model was developed, describing mass transfer and kinetic phenomena governing the acid gas neutralization with solid sorbents. The rate controlling steps were identified through the reproduction of literature data, allowing the description of acid gas removal in the case study analyzed. A laboratory device was also designed and started up to assess the required model parameters.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Heavy alcohol consumption may accelerate the progression of hepatitis C-related liver disease and/or limit efforts at antiviral treatment in opioid-dependent patients receiving heroin-assisted treatment (HAT). Our study aims to assess alcohol intake among HAT patients by self-reports compared to direct ethanol metabolites.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

There is a growing interest in the location of Treatment, Storage, and Disposal (TSDF) sites in relation to minority communities. A number of studies have been completed, and the results of these studies have been varied. Some of the studies have shown a strong positive correlation between the location of TSDF sites and minority populations, while a few have shown no significance in that relationship. The major difference between these studies has been in the areal unit used.^ This study compared the minority populations of Texas census tracts and ZIP codes containing a TSDF using the associated county as the comparison population. The hypothesis of this study was that there was no difference between using census tracts and ZIP codes to analyze the relationship of minority populations and TSDF's. The census data used was from 1990, and the initial list of TSDF sites was supplied by the Texas Natural Resource Conservation Commission. The TSDF site locations were checked using graphical information systems (GIS) programs, in order to increase the accuracy of the identity of exposed ZIP codes and census tracts. The minority populations of the exposed areal units were compared using proportional differences, crosstables, maps, and logistic regression. The dependent variable used was the exposure status of the areal units under study, including counties, census tracts, and ZIP codes. The independent variables used included minority group proportion and grouping of the proportions, educational status, household income, and home value.^ In all cases, education was significant or near significant at the.05 level. Education rather than minority proportion was therefore the most significant predictor of the exposure status of a census tract or ZIP code. ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Inefficiencies during the management of healthcare waste can give rise to undesirable health effects such as transmission of infections and environmental pollution within and beyond the health facilities generating these wastes. Factors such as prevalence of diseases, conflicts, and the efflux of intellectual capacity make low income countries more susceptible to these adverse health effects. The purpose of this systematic review was to describe the effectiveness of interventions geared towards better managing the generation, collection, transport, treatment and disposal of medical waste, as they have been applied in lower and middle income countries.^ Using a systematic search strategy and evaluation of study quality, this study reviewed the literature for published studies on healthcare waste management interventions carried out in developing countries, specifically the low and lower middle income countries from year 2000 to the current year. From an initially identified set of 829 studies, only three studies ultimately met all inclusion, exclusion and high quality criteria. A multi component intervention in Syrian Arab Republic, conducted in 2007 was aimed at improving waste segregation practice in a hospital setting. There was an increased use of segregation boxes and reduced rates of sharps injury among staff as a result of the intervention. Another study, conducted in 2008, trained medical students as monitors of waste segregation practice in an Indian teaching hospital. There was improved practice in wards and laboratories but not in the intensive care units. The third study, performed in 2008 in China, consisted of modification of the components of a medical waste incinerator to improve efficiency and reduce stack emissions. Gaseous pollutants emitted, except polychlorodibenzofurans (PCDF) were below US EPA permissible exposure limits. Heavy metal residues in the fly ash remained unchanged.^ Due to the paucity of well-designed studies, there is insufficient evidence in literature to conclude on the effectiveness of interventions in low income settings. There is suggestive but insufficient evident that multi-component interventions aimed at improving waste segregation through behavior modification, provision of segregation tools and training of monitors are effective in low income settings.^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The occurrence of waste pharmaceuticals has been identified and well documented in water sources throughout North America and Europe. Many studies have been conducted which identify the occurrence of various pharmaceutical compounds in these waters. This project is an extensive review of the documented evidence of this occurrence published in the scientific literature. This review was performed to determine if this occurrence has a significant impact on the environment and public health. This project and review found that pharmaceuticals such as sex hormone drugs, antibiotic drugs and antineoplastic/cytostatic agents as well as their metabolites have been found to occur in water sources throughout the United States at levels high enough to have noticeable impacts on human health and the environment. It was determined that the primary sources of this occurrence of pharmaceuticals were waste water effluent and solid wastes from sewage treatment plants, pharmaceutical manufacturing plants, healthcare and biomedical research facilities, as well as runoff from veterinary medicine applications (including aquaculture). ^ In addition, current public policies of US governmental agencies such as the Environmental Protection Agency (EPA), Food and Drug Administration (FDA), and Drug Enforcement Agency (DEA) have been evaluated to see if they are doing a sufficient job at controlling this issue. Specific recommendations for developing these EPA, FDA, and DEA policies have been made to mitigate, prevent, or eliminate this issue.^ Other possible interventions such as implementing engineering controls were also evaluated in order to mitigate, prevent and eliminate this issue. These engineering controls include implementing improved current treatment technologies such as the advancement and improvement of waste water treatment processes utilized by conventional sewage treatment and pharmaceutical manufacturing plants. In addition, administrative controls such as the use of “green chemistry” in drug synthesis and design were also explored and evaluated as possible alternatives to mitigate, prevent, or eliminate this issue. Specific recommendations for incorporating these engineering and administrative controls into the applicable EPA, FDA, and DEA policies have also been made.^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The siloxanes present in the biogas produced during anaerobic digestion damage the mechanism of cogeneration equipment and, consequently, negatively affect the energy valorization process. For this reason, the detection and elimination of these silicon-derived chemical compounds are a priority in the management of cogeneration facilities. In this regard, the objectives of this paper are, firstly, to characterize the siloxanes in the biogas and, secondly, to qualitatively evaluate the influence of the dose of iron chloride on its elimination. The research was performed at the Rincón de León Wastewater Treatment Plant (Alicante, Spain). The outflow biogas of the digesters and of the pressurized gasometers was sampled and analyzed. The results obtained made it possible to demonstrate, firstly, the absence of linear siloxanes and that, of the cyclic siloxanes, the predominant type was decamethylcyclopentasiloxane, and, secondly, that the addition of iron chloride in the digesters significantly reduces the siloxane content in the biogas. Additionally, it was demonstrated that the process of compression of the biogas, with the elimination of condensates, also produces significant reductions in the concentration of siloxanes in the biogas.