982 resultados para Group B Streptococcus (GBS)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Examining three bleaching systems, this in vivo clinical trial evaluated the relationship among tooth sensitivity, light activation, and agent concentration, and it correlated dental sensitivity with tooth thickness.Materials and Methods: Eighty-seven volunteer patients were included. Inclusion criteria were the presence of anterior teeth without restorations as well as the absence of a previous bleaching experience and absence of non-carious cervical lesions or dental pain. Exclusion criteria included pregnancy or breastfeeding, a maximum of TF3 hypoplasia, tetracycline-fluorosis stains, malpositioned teeth, orthodontic treatment, periodontal disease, and/or analgesic/anti-inflammatory intake. Patients were randomly assigned to three bleaching groups: Group A (n=25) was treated with 15% H2O2 and nitrogenous-titanium-dioxide and was light activated (Lase Peroxide Lite, DMC, SaoCarlos, Sao Paulo, Brazil); Group B (n=27) was treated with 35% H2O2 and was light activated (Lase Peroxide Sensy, DMC); and Group C (n=35) was treated with 35% H2O2 (White Gold Office, Dentsply, 38West Clark Ave., Milford, USA) without light activation. Tooth sensitivity (TS) was self-reported by the patients using the visual analog scale (VAS) at baseline (TSO), immediately after treatment (TSI), and at seven days after treatment (TS7). In 46 patients, tooth thickness was determined by computed tomography. TSO, TSI, and TS7 were compared between the A and B groups to determine the effect of concentration and between the B and C groups to determine the effect of light using analysis of covariance. The correlation between tooth thickness and TSI was determined by Spearman Rho test (SPSS 15).Results: Eighty-seven patients were evaluated at baseline, and 61 were evaluated at seven days. Separated by groups, tooth sensitivity, expressed as VAS value at the time points TS0, TS1, and TS7, respectively, were as follows: Group A: 13.76 +/- 13.53, 24.40 +/- 25.24, and 5.94 +/- 5.5; Group B: 15.07 +/- 18.14, 42.4 +/- 31.78, and 8.68 +/- 17.99; and Group C: 10.80 +/- 14.83, 31.51 +/- 29.34, and 7.24 +/- 9.2. Group A showed significantly lower tooth sensitivity than group B at TSI (p=0.032). No differences were observed in the tooth sensitivities between groups B and C. No correlation was encountered between tooth thickness and tooth sensitivity immediately after treatment (Rho=-0.088,p=0.563). The median tooth thickness was 2.78 +/- 0.21 mm.Conclusions: Increases in the concentration of bleaching agents directly affect tooth sensitivity, and LED/laser activation and tooth thickness are not correlated with tooth sensitivity after dental bleaching.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The primary stability of dental implants is fundamental for osseointegration. Therefore, this study aimed to assess the correlation between insertion torque (IT) and resonance frequency analysis (RFA) of implants placed in mandibles and maxillas of different bone densities. Eighty dental implants were placed in maxillas and mandibles, and IT and the implant stability quotient (ISQ) were measured at the time of implant insertion. Bone density was assessed subjectively by the Lekholm and Zarb index. The type I and II densities were grouped together (group A)as were the type III and IV densities (group B). The IT in group A was higher (Student t test, P = .0013) than in group B (46.27 +/- 18.51 Ncm, 33.62 +/- 14.74 Ncm, respectively). The implants placed in group A showed higher ISQ (Student t test, P = .0004) than those placed in group B (70.09 +/- 7.50, 63.66 +/- 8.00, respectively). A significant correlation between IT and the ISQ value was observed for group A (Pearson correlation test; r = 0.35; P = .0213) and for group B (r = 0.37; P = .0224). Within the limitations of this study, it was possible to conclude that there is a correlation between IT and RFA of implants placed in mandibles and maxillas of different bone densities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to evaluate the effect of surface treatment with Er:YAG and Nd:YAG lasers on resin composite bond strength to recently bleached dentin. A total of 120 bovine incisors were distributed into two groups: C- without bleaching; and B- bleached with 35% hydrogen peroxide. Each group was divided into three subgroups: N- without laser treatment; Nd- Nd:YAG laser irradiation; and Er- Er:YAG laser irradiation. The adhesive system (Adper Single Bond 2) was applied and composite build-ups were constructed with Filtek Supreme (3M/ESPE). The teeth were sectioned to obtain dentin-resin sticks (1x1mm(2)) and tested by microtensile bond testing. The bond strength values in group B, subgroup N (16.1 +/- 3.5MPa) presented no significant difference compared with group B, subgroup Er (14.7 +/- 6.1MPa). Group C, subgroup N (26.8 +/- 7.4MPa) presented no significant difference compared with group B, subgroup Nd (28.8 +/- 5.6MPa). Group C, subgroup Nd (36.1 +/- 7.9MPa) presented a significant increase in bond strength compared with the other groups. The Er:YAG laser did not influence the bond strength of bleached specimens, and the use of the Nd:YAG laser on bleached specimens was able to reverse the immediate effects of bleaching, obtaining bond strength values similar to those of the control group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study aimed to evaluate the efficacy of a multivitamin and poly minerals supplemented with Panax ginseng extract (Gerovital®) on patients suffering from common physical or mental stress. The study design was controlled, parallel and double blind. Patients were randomly divided in two groups and underwent a thorough clinical and laboratory examination. Group A received placebo capsules and group B received Gerovital® capsules. In both cases, two capsules were taken daily during meals for eight weeks. Mood as well as physical activity were evaluated through a questionnaire assessing quality of life. From the 126 patients enrolled, 12 patients (8 in group A and 4 in group B) were excluded due to voluntary withdrawal, 55 patients completed the study in group A and 59 in group B. The treatment with Gerovital® significantly increased the quality of life when compared to placebo. After 15 days of study no difference between groups was observed. However, at 30th, 45th and 60th day, group B showed a statistically significant increase in average score from 30.05 to 41.96, 47.01 and finally 50.81 points. No increase in body weight was detected in either group. No difference in blood pressure or heart rate was also observed between treatments. The present study has shown that the daily use of Gerovital® over a 2-month period can be effective in improving quality of life in patients suffering from physical and mental stress among individuals of different ages, ranging from adults to elderly. Moreover, its use has been associated to a lower incidence of flu-like seasonal respiratory illnesses. Finally, the incidence of undesired effects was similar to placebo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste estudo foi buscar um melhor entendimento sobre a dor músculo-esquelética crônica da face e sua relação com o bruxismo do sono. Quarenta pacientes foram avaliados de acordo com o Research Diagnostic Criteria for Temporomandibular Disorders: Grupo A - 20 pacientes com DTM, com média de idade de 32,7 anos e duração média da dor de 4,37 anos; Grupo B - 20 pacientes sem DTM, com média de idade de 30,8 anos. As variáveis do sono e do bruxismo foram avaliadas em exame polissonográfico. As características clínicas foram estatisticamente diferentes entre os dois grupos: o grupo A apresentou maior freqüência de auto-relato de dor matinal (p=0,0113) e estalido articular (p=0,0269), maior grau de sintomas físicos não específicos (p=0,001) e de limitações da função mandibular (p=0,001). Não houve diferença estatisticamente significativa para as variáveis do bruxismo: número de episódios de bruxismo por hora, número de surtos por episódio e por hora, duração total, porcentagem em cada estágio do sono, tipo e amplitude dos episódios. A arquitetura do sono mostrou-se dentro dos parâmetros de normalidade, sem nenhuma diferença estatisticamente significativa entre os dois grupos. Conclusões: as características clínicas dos pacientes com bruxismo do sono, com e sem DTM, são diferentes, mas as características do sono e do bruxismo são similares. Mais estudos são necessários para esclarecer as razões pelas quais alguns pacientes com bruxismo do sono desenvolvem dor milfascial crônica e outros não.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Health care waste (HCW) is the type of waste that results from activities performed in health care services during care provision to humans or animals. Presently, according to RDC 306/04, issued in 2004 by Anvisa, and Resolution no. 358/05, by CONAMA, waste groups have the following classification: Group A (biological waste), Group B (chemical waste), Group C (waste containing radionucleotides), Group D (common waste) and Group E (piercing and cutting waste). In Brazil, 149 tons of wastes are collected every day, and HCW corresponds to approximately 1% to 3 % of that total. An efficient way to adequately manage HCW is through the Health Care Waste Management Plan (HCWMP), and it is possible to reduce the risk posed by certain materials in addition to ensuring disposal in an ecologically correct and economical fashion. According to the Pan-American Health Organization (PAHO), the management process enables health care establishments to adequately manage waste. Hence, there is greater control and reduction in the health risks caused by infectious or special waste, in addition to facilitated recycling, treatment, storage, transport and final disposal of solid hospital waste in an environmentally safe fashion. To evaluate the management of HCW of Groups A and D from the Intensive Care Unit of the University Emergency Hospital - FMB - UNESP in the city of Botucatu according to the guidelines presently in force. The waste flow was followed up, and during four random days in the month of September 2011, waste was quantified by estimating daily and monthly values, according to its classification. : In 2011, the University hospital has produced an average of 57,676.8 kg/month of biological and common waste. By adding Groups A and D, during the four days, approximately 209.8 Kg of waste (202.2 Kg of Group A and 7.6 Kg of Group D) were produced in the establishment under study, which... (Complete abstract click electronic access below)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the effect of surface treatment with Er:YAG and Nd:YAG laser on resin composite bond strength to recently bleached dentin. Material and Methods: In this study 120 bovine incisors were used and distributed into two groups: Group C: without bleaching treatment; Group B: with bleaching treatment (35% hydrogen peroxide). Each group was divided into three subgroups: Subgroup N: without laser treatment; Subgroup Nd: irradiation with Nd:YAG laser; Subgroup Er: irradiation with Er:YAG laser. Next, the adhesive system (Adper Single Bond 2) was applied and composite buildups were constructed with Z350 composite. The teeth were sectioned to obtain dentin-resin sticks (1x1mm) and analyzed by microtensile bond testing. The data were statistically analyzed by the ANOVA and Tukey tests. Results: The results showed that the bond strength values in the bleached control group (16.17 MPa) presented no significant difference in comparison with the group bleached and irradiated with Er:YAG laser (14.69 MPa). The non bleached control group (26.79 MPa) presented significant difference in bond strength when compared with the non bleached group irradiated with Er:YAG laser (22.82 MPa) and with the group treated by bleaching and irradiation with Nd:YAG laser (28,792 MPa). The group without bleaching treatment and irradiated with Nd:YAG (36.1 MPa) presented a significant increase in bond strength in comparison with the other groups. Conclusion: The use of Nd:YAG laser on bleached specimens was able of completely reversing the immediate effects of bleaching, obtaining bond strength values similar to those of the control group

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the influence of examiner's clinical experience on detection and treatment decision of caries lesions in primary molars. Design Three experienced dentists (Group A) and three undergraduate students (Group B) used the International Caries Detection and Assessment System (ICDAS) criteria and bitewing radiographs (BW) to perform examinations twice in 77 primary molars that presented a sound or carious occlusal surface. For the treatment decision (TD), the examiners attributed scores, analyzing the teeth in conjunction with the radiographs. The presence and the depth of lesion were validated histologically, and reproducibility was evaluated. The sensitivity, specificity, accuracy, and area under the ROC curve values were calculated for ICDAS and BW. The associations between ICDAS, BW, and TD were analyzed by means of contingency tables. Results Interexaminer agreement for ICDAS, BW, and TD were excellent for Group B and moderate for Group A. The two groups presented similar and satisfactory performance for caries lesion detection using ICDAS and BW. In the treatment decision, Group A was shown to have a less invasive approach than Group B. Conclusion The examiner's experience was not determinant for the clinical and radiographic detection of occlusal lesions in primary teeth but influenced the treatment decision of initial lesions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to assess if the positioning of the impression tray could cause plaster casts distortion during gypsum setting time. fifteen pairs of master models were cast with alginate impression material and immediately poured with gypsum. impressions were allowed to set with the tray in the not inverted position (group a) or in the inverted position (group b). the plaster models were digitized using a laser scanner (3shape r-700, 3shape a/s). tooth size measurements and distances were obtained using o3d software (widialabs, brasil) measurement tools. data were analyzed by paired t test and linear regression with 5% significance. most measurements of both groups were similar, except for the lower intermolar distance. it was not possible to corroborate the presence of distortions owing to the position of the impression tray during gypsum setting time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study was designed to evaluate the correlation between computed tomography findings and data from the physical examination and the Friedman Staging System (FSS) in patients with obstructive sleep apnea (OSA). Patients and Methods: We performed a retrospective evaluation by reviewing the medical records of 33 patients (19 male and 14 female patients) with a mean body mass index of 30.38 kg/m 2 and mean age of 49.35 years. Among these patients, 14 presented with severe OSA, 7 had moderate OSA, 7 had mild OSA, and 5 were healthy. Results: The patients were divided into 2 groups according to the FSS: Group A comprised patients with FSS stage I or II, and group B comprised patients with FSS stage III. By use of the Fisher exact test, a positive relationship between the FSS stage and apnea-hypopnea index ( P = .011) and between the FSS stage and body mass index ( P = .012) was found. There was no correlation between age ( P = .55) and gender ( P = .53) with the FSS stage. The analysis of variance test comparing the upper airway volume between the 2 groups showed P =.018. Conclusions: In this sample the FSS and upper airway volume showed an inverse correlation and were useful in analyzing the mechanisms of airway collapse in patients with OSA.