861 resultados para Grid-connected
Resumo:
The power system of the future will have a hierarchical structure created by layers of system control from via regional high-voltage transmission through to medium and low-voltage distribution. Each level will have generation sources such as large-scale offshore wind, wave, solar thermal, nuclear directly connected to this Supergrid and high levels of embedded generation, connected to the medium-voltage distribution system. It is expected that the fuel portfolio will be dominated by offshore wind in Northern Europe and PV in Southern Europe. The strategies required to manage the coordination of supply-side variability with demand-side variability will include large scale interconnection, demand side management, load aggregation and storage in the concept of the Supergrid combined with the Smart Grid. The design challenge associated with this will not only include control topology, data acquisition, analysis and communications technologies, but also the selection of fuel portfolio at a macro level. This paper quantifies the amount of demand side management, storage and so-called ‘back-up generation’ needed to support an 80% renewable energy portfolio in Europe by 2050.
Resumo:
This co-authored essay outlines and analyses the AHRC 'Creative Interruptions' Project, 'Where do I belong?', a theatre-as-research project conducted with Afghan refugees in London under the guidance of PI Sarita Malik, Brunel University London.
Resumo:
This paper presents a framework for a telecommunications interface which allows data from sensors embedded in Smart Grid applications to reliably archive data in an appropriate time-series database. The challenge in doing so is two-fold, firstly the various formats in which sensor data is represented, secondly the problems of telecoms reliability. A prototype of the authors' framework is detailed which showcases the main features of the framework in a case study featuring Phasor Measurement Units (PMU) as the application. Useful analysis of PMU data is achieved whenever data from multiple locations can be compared on a common time axis. The prototype developed highlights its reliability, extensibility and adoptability; features which are largely deferred from industry standards for data representation to proprietary database solutions. The open source framework presented provides link reliability for any type of Smart Grid sensor and is interoperable with existing proprietary database systems, and open database systems. The features of the authors' framework allow for researchers and developers to focus on the core of their real-time or historical analysis applications, rather than having to spend time interfacing with complex protocols.
Resumo:
The need for fast response demand side participation (DSP) has never been greater due to increased wind power penetration. White domestic goods suppliers are currently developing a `smart' chip for a range of domestic appliances (e.g. refrigeration units, tumble dryers and storage heaters) to support the home as a DSP unit in future power systems. This paper presents an aggregated population-based model of a single compressor fridge-freezer. Two scenarios (i.e. energy efficiency class and size) for valley filling and peak shaving are examined to quantify and value DSP savings in 2020. The analysis shows potential peak reductions of 40 MW to 55 MW are achievable in the Single wholesale Electricity Market of Ireland (i.e. the test system), and valley demand increases of up to 30 MW. The study also shows the importance of the control strategy start time and the staggering of the devices to obtain the desired filling or shaving effect.
Resumo:
The results in this paper are based on a data set containing system demand, wind generation and CO2 emission between Jan 2010 and Sep 2013. The data was recorded at 15 minute intervals and reflects the macroscopic operation of the Republic of Ireland's electrical grid. The data was analyzed by investigating how daily wind generation effected daily CO2 emission across multiple days with equivalent daily demand. A figure for wind turbine efficiency was determined by dividing the CO2 mitigation potential of wind power by the CO2 intensity of the grid; both in units of Tonnes of CO2 per MWh. The yearly wind power efficiency appears to have increased by 5.6% per year, now standing around 90%. Over the four years significant regularity was observed in the profiles of wind turbine efficiency against daily demand. It appears that the efficiency profile has moved in recent years so that maximum efficiency coincides with most frequent demand.
Resumo:
This paper explores the theme of exhibiting architectural research through a particular example, the development of the Irish pavilion for the 14th architectural biennale, Venice 2014. Responding to Rem Koolhaas’s call to investigate the international absorption of modernity, the Irish pavilion became a research project that engaged with the development of the architectures of infrastructure in Ireland in the twentieth and twenty-first centuries. Central to this proposition was that infrastructure is simultaneously a technological and cultural construct, one that for Ireland occupied a critical position in the building of a new, independent post-colonial nation state, after 1921.
Presupposing infrastructure as consisting of both visible and invisible networks, the idea of a matrix become a central conceptual and visual tool in the curatorial and design process for the exhibition and pavilion. To begin with this was a two-dimensional grid used to identify and order what became described as a series of ten ‘infrastructural episodes’. These were determined chronologically across the decades between 1914 and 2014 and their spatial manifestations articulated in terms of scale: micro, meso and macro. At this point ten academics were approached as researchers. Their purpose was twofold, to establish the broader narratives around which the infrastructures developed and to scrutinise relevant archives for compelling visual material. Defining the meso scale as that of the building, the media unearthed was further filtered and edited according to a range of categories – filmic/image, territory, building detail, and model – which sought to communicate the relationship between the pieces of architecture and the larger systems to which they connect. New drawings realised by the design team further iterated these relationships, filling in gaps in the narrative by providing composite, strategic or detailed drawings.
Conceived as an open-ended and extendable matrix, the pavilion was influenced by a series of academic writings, curatorial practices, artworks and other installations including: Frederick Kiesler’s City of Space (1925), Eduardo Persico and Marcello Nizzoli’s Medaglio d’Oro room (1934), Sol Le Witt’s Incomplete Open Cubes (1974) and Rosalind Krauss’s seminal text ‘Grids’ (1979). A modular frame whose structural bays would each hold and present an ‘episode’, the pavilion became both a visual analogue of the unseen networks embodying infrastructural systems and a reflection on the predominance of framed structures within the buildings exhibited. Sharing the aspiration of adaptability of many of these schemes, its white-painted timber components are connected by easily-dismantled steel fixings. These and its modularity allow the structure to be both taken down and re-erected subsequently in different iterations. The pavilion itself is, therefore, imagined as essentially provisional and – as with infrastructure – as having no fixed form. Presenting archives and other material over time, the transparent nature of the space allowed these to overlap visually conveying the nested nature of infrastructural production. Pursuing a means to evoke the qualities of infrastructural space while conveying a historical narrative, the exhibition’s termination in the present is designed to provoke in the visitor, a perceptual extension of the matrix to engage with the future.
Resumo:
Cyber-security research in the field of smart grids is often performed with a focus on either the power and control domain or the Information and Communications Technology (ICT) domain. The characteristics of the power equipment or ICT domain are commonly not collectively considered. This work provides an analysis of the physical effects of cyber-attacks on microgrids – a smart grid construct that allows continued power supply when disconnected from a main grid. Different types of microgrid operations are explained (connected, islanded and synchronous-islanding) and potential cyber-attacks and their physical effects are analyzed. A testbed that is based on physical power and ICT equipment is presented to validate the results in both the physical and ICT domain.
Resumo:
We extend the generalized Langevin equation (GLE) method [L. Stella, C. D. Lorenz, and L. Kantorovich, Phys. Rev. B 89, 134303 (2014)] to model a central classical region connected to two realistic thermal baths at two different temperatures. In such nonequilibrium conditions a heat flow is established, via the central system, in between the two baths. The GLE-2B (GLE two baths) scheme permits us to have a realistic description of both the dissipative central system and its surrounding baths. Following the original GLE approach, the extended Langevin dynamics scheme is modified to take into account two sets of auxiliary degrees of freedom corresponding to the mapping of the vibrational properties of each bath. These auxiliary variables are then used to solve the non-Markovian dissipative dynamics of the central region. The resulting algorithm is used to study a model of a short Al nanowire connected to two baths. The results of the simulations using the GLE-2B approach are compared to the results of other simulations that were carried out using standard thermostatting approaches (based on Markovian Langevin and Nosé-Hoover thermostats). We concentrate on the steady-state regime and study the establishment of a local temperature profile within the system. The conditions for obtaining a flat profile or a temperature gradient are examined in detail, in agreement with earlier studies. The results show that the GLE-2B approach is able to treat, within a single scheme, two widely different thermal transport regimes, i.e., ballistic systems, with no temperature gradient, and diffusive systems with a temperature gradient.
Resumo:
Tese de doutoramento, Sistemas Sustentáveis de Energia, Universidade de Lisboa, Faculdade de Ciências, 2016
Resumo:
Doctor Watson Architects joined with Samir Pandya and a select group of architecture students to work with line, colour and thread as a means of achieving a psycho-dynamic suspension of matter form and space in the newly opened studios on the 4th & 5th floors of the University of Westminster's Marylebone Block.
Resumo:
In the Sparse Point Representation (SPR) method the principle is to retain the function data indicated by significant interpolatory wavelet coefficients, which are defined as interpolation errors by means of an interpolating subdivision scheme. Typically, a SPR grid is coarse in smooth regions, and refined close to irregularities. Furthermore, the computation of partial derivatives of a function from the information of its SPR content is performed in two steps. The first one is a refinement procedure to extend the SPR by the inclusion of new interpolated point values in a security zone. Then, for points in the refined grid, such derivatives are approximated by uniform finite differences, using a step size proportional to each point local scale. If required neighboring stencils are not present in the grid, the corresponding missing point values are approximated from coarser scales using the interpolating subdivision scheme. Using the cubic interpolation subdivision scheme, we demonstrate that such adaptive finite differences can be formulated in terms of a collocation scheme based on the wavelet expansion associated to the SPR. For this purpose, we prove some results concerning the local behavior of such wavelet reconstruction operators, which stand for SPR grids having appropriate structures. This statement implies that the adaptive finite difference scheme and the one using the step size of the finest level produce the same result at SPR grid points. Consequently, in addition to the refinement strategy, our analysis indicates that some care must be taken concerning the grid structure, in order to keep the truncation error under a certain accuracy limit. Illustrating results are presented for 2D Maxwell's equation numerical solutions.