980 resultados para Finite Abelian P-Groups
Resumo:
In implant therapy, a peri-implant bone resorption has been noticed mainly in the first year after prosthesis insertion. This bone remodeling can sometimes jeopardize the outcome of the treatment, especially in areas in which short implants are used and also in aesthetic cases. To avoid this occurrence, the use of platform switching (PS) has been used. This study aimed to evaluate the biomechanical concept of PS with relation to stress distribution using two-dimensional finite element analysis. A regular matching diameter connection of abutment-implant (regular platform group [RPG]) and a PS connection (PS group [PSG]) were simulated by 2 two-dimensional finite element models that reproduced a 2-piece implant system with peri-implant bone tissue. A regular implant (prosthetic platform of 4.1 mm) and a wide implant (prosthetic platform of 5.0 mm) were used to represent the RPG and PSG, respectively, in which a regular prosthetic component of 4.1 mm was connected to represent the crown. A load of 100 N was applied on the models using ANSYS software. The RPG spreads the stress over a wider area in the peri-implant bone tissue (159 MPa) and the implant (1610 MPa), whereas the PSG seems to diminish the stress distribution on bone tissue (34 MPa) and implant (649 MPa). Within the limitation of the study, the PS presented better biomechanical behavior in relation to stress distribution on the implant but especially in the bone tissue (80% less). However, in the crown and retention screw, an increase in stress concentration was observed.
Resumo:
Purpose: This study evaluated the influence of distal extension removable partial denture associated with implant in cases of different bone level of abutment tooth, using 2D finite element analysis.Materials and Methods: Eight hemiarch models were simulated: model A-presenting tooth 33 and distal extension removable partial denture replacing others teeth, using distal rest connection and no bone lost; model B-similar to model A but presenting distal guide plate connection; model C-similar to model A but presenting osseointegrated implant with ERA retention system associated under prosthetic base; model D-similar to model B but presenting osseointegrated implant as described in model C; models E, F, G, and H were similar to models A, B, C, and D but presenting reduced periodontal support around tooth 33. Using ANSYS 9.0 software, the models were loaded vertically with 50 N on each cusp tip. For results, von Mises Stress Maps were plotted.Results: Maximum stress value was encountered in model G (201.023 MPa). Stress distribution was concentrated on implant and retention system. The implant/removable partial denture association decreases stress levels on alveolar mucosa for all models.Conclusions: Use of implant and ERA system decreased stress concentrations on supporting structures in all models. Use of distal guide plate decreased stress levels on abutment tooth and cortical and trabecular bone. Tooth apex of models with reduced periodontal support presented increased stress when using distal rest. (Implant Dent 2011;20:192-201)
Resumo:
The authors describe a literature revision on assessing stresses in buccomaxillary prostheses photoelasticity, finite element technique, and extensometry. They describe the techniques and the importance for use of each method in buccomaxillary prostheses with implants and the need of accomplishing more studies in this scarce literary area.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: The non-homogenous aspect of periodontal ligament (PDL) has been examined using finite element analysis (FEA) to better simulate PDL behavior. The aim of this study was to assess, by 2-D FEA, the influence of non-homogenous PDL on the stress distribution when the free-end saddle removable partial denture (RPD) is partially supported by an osseointegrated implant. Material and Methods: Six finite element (FE) models of a partially edentulous mandible were created to represent two types of PDL (non-homogenous and homogenous) and two types of RPD (conventional RPD, supported by tooth and fibromucosa; and modified RPD, supported by tooth and implant [10.00x3.75 mm]). Two additional FE models without RPD were used as control models. The non-homogenous PDL was modeled using beam elements to simulate the crest, horizontal, oblique and apical fibers. The load (50 N) was applied in each cusp simultaneously. Regarding boundary conditions the border of alveolar ridge was fixed along the x axis. The FE software (Ansys 10.0) was used to compute the stress fields, and the von Mises stress criterion (sigma vM) was applied to analyze the results. Results: The peak of sigma vM in non-homogenous PDL was higher than that for the homogenous condition. The benefits of implants were enhanced for the non-homogenous PDL condition, with drastic sigma vM reduction on the posterior half of the alveolar ridge. The implant did not reduce the stress on the support tooth for both PDL conditions. Conclusion: The PDL modeled in the non-homogeneous form increased the benefits of the osseointegrated implant in comparison with the homogeneous condition. Using the non-homogenous PDL, the presence of osseointegrated implant did not reduce the stress on the supporting tooth.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Statement of problem. To select the width of denture teeth, the distance between the marks indicating the location of the canines is usually measured around the curvature of the wax occlusal rim; however, most manufacturers' mold charts provide the measurements of the artificial 6 anterior teeth as if they were on a straight line.Purpose. The purpose of this study was to investigate whether the curve distance between the distal surfaces of the maxillary canines can be related to the combined width (straight measurement) of the 6 anterior teeth in 4 ethnic groups.Material and methods. Maxillary stone casts were obtained for 160 dentate subjects of 4 ethnic groups (40 whites, 40 blacks, 40 multiracial - descendants of white and black parents, and 40 Asians). The width of each maxillary anterior tooth was measured on the casts with sliding calipers. The combined width of the 6 anterior teeth (CW) corresponded to the sum of the width of each anterior tooth. The curve distance between the distal surfaces of the canines (CD) was measured by using dental tape and sliding calipers. The Pearson correlation coefficient and regression analysis were used to evaluate the relationship between CD and CW in each ethnic group (alpha=.05).Results. The mean CD and CW values (in mm) obtained were: whites (CD=52.12; CW=45.65); blacks (CD=56.10; CW=48.13); multiracial (CD=53.58; CW=46.54); and Asians (CD=53.29; CW=46.60). Significant (P<.001) correlations between CD and CW measurements were observed for all ethnic groups studied (whites, r=0.957; blacks, r=0.803; multiracial, r=0.917; and Asians, r=0.881). The following linear regression equations were obtained: whites [CD=1.1(CW)+0.3]; blacks [CD=0.95(CW)+9.3]; multiracial [CD=1.2(CW)-1.1]; and Asians [CD=1.0(CW)+5].Conclusions. The curve distance between the distal surfaces of the maxillary canines can be accurately related to the combined width of the 6 anterior teeth in the selection of denture teeth for the studied ethnic groups. (J Prosthet Dent 2012;107:400-404)
Resumo:
Objectives: To evaluate the use of the center of the incisive papilla as a guide for the selection of the proper width of maxillary dentures in 4 racial groups. Method and Materials: One hundred sixty stone casts were obtained from impressions of the maxillary arch of white, black, mixed, and Asian subjects. The occlusal surfaces of the casts were photocopied and the images placed on a digitizer. The most anterior and posterior points of the papilla and cusp tips of the canines were digitized. Dentofacial Planner Plus software was used to calculate the distance from a line passing through the cusp tips of the canines to the center of the papilla, defined as the midpoint of the anterior and posterior points of the papilla. The selection error (in millimeters) due to the clinical application of the method of the incisive papilla was calculated and analyzed. Results: In all studied racial groups, there was no coincidence between the center of the incisive papilla and the canine line. The utilization of the center of the papilla would lead to the selection of wider artificial teeth. In 24.9% of the white, 19.3% of the mixed, 32.9% of the black, and 15.5% of the Asian populations, errors greater than 4 mm would be present with the utilization of the papilla. Conclusion: The method of the center of the incisive papilla is not accurate, but may aid in initial artificial teeth selection for the racial groups studied. (Quintessence Int 2008;39:841-845)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Silica gel chemically modified with 2-aminotiazole groups (SiAT), was used for preconcentration of cupper, zinc, nickel and iron from gasoline, normally used as a engine fuel. Surface characteristics and surface area of the silica gel were obtained before and after chemical modification using FT-IR, Kjeldhal and surface area analysis (B.E.T.). The retention and recovery of the analyte elements were studied by applying batch and column techniques. The experimental parameters, such as shaking time in batch technique, flow rate and concentration of the eluent (HCl-0.25-2.00 mol 1(-1)) and the amount of silica, on retention and elution, have been investigated. Detection limits of the method for cupper, iron, nickel and zinc are 0.8, 3, 2 and 0.1 mug 1(-1), respectively. The sorption-desorption of the studied metal ions made possible the development of a preconcentration method for metal ions at trace level in gasoline using flame AAS for their quantification. (C) 2004 Published by Elsevier Ltd.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)