827 resultados para Femoral shaft Fractures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Serum protein S-100B determinations have been widely proposed in the past as markers of traumatic brain injury and used as a predictor of injury severity and outcome. The purpose of this prospective observational case series was therefore to determine S-100B serum levels in patients with isolated injuries to the back. METHODS: Between 1 February and 1 May 2008, serum samples for S-100B analysis were obtained within 1 hour of injury from 285 trauma patients. All patients with a head injury, polytrauma, and intoxicated patients were excluded to select isolated injuries to the spine. 19 patients with isolated injury of the back were included. Serum samples for S-100B analysis and CT spine were obtained within 1 hours of injury. RESULTS: CT scans showed vertebral fractures in 12 of the 19 patients (63%). All patients with fractures had elevated S-100B levels. Amongst the remaining 7 patients without a fracture, only one patient with a severe spinal contusion had an S-100B concentration above the reference limit. The mean S-100B value of the group with fractures was more than 4 times higher than in the group without fractures (0.385 vs 0.087 mug/L, p = 0.0097). CONCLUSION: Our data, although limited due to a very small sample size, suggest that S-100B serum levels might be useful for the diagnosis of acute vertebral body and spinal cord injury with a high negative predictive power. According to the literature, the highest levels of serum S-100B are found when large bones are fractured. If a large prospective study confirms our findings, determining the S-100B level may contribute to more selective use of CT and MRI in spinal trauma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for the introduction of strong discontinuities into a mesh will be developed. This method, applicable to a number of eXtended Finite Element Methods (XFEM) with intra-element strong discontinuities will be demonstrated with one specific method: the Generalized Cohesive Element (GCE) method. The algorithm utilizes a subgraph mesh representation which may insert the GCE either adaptively during the course of the analysis or a priori. Using this subgraphing algorithm, the insertion time is O(n) to the number of insertions. Numerical examples are presented demonstrating the advantages of the subgraph insertion method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate fracture patterns in bicondylar tibial plateau fractures and their impact on treatment strategy. DESIGN: Prospective data analysis with documentation of initial injury and treatment strategy, computed tomography scans, conventional x-rays, long-term evaluation of radiographs, and functional assessments. SETTING: Level 1 regional trauma center. PATIENTS: Prospective data acquisition of 14 consecutive patients (10 male and 4 female) with a bicondylar tibial plateau fracture (AO Type C). INTERVENTION: Application of a stepwise reconstruction strategy of the tibial plateau starting with the reposition and fixation of the posteromedial split fragment using a 3.5 buttress plate, followed by reposition and grafting of the lateral compartment and lateral fixation with a 3.5 plate in 90 degree to the medial fixation device. MAIN OUTCOME MEASUREMENTS: All patients were evaluated with full-length standing film, standardized x-rays, Lysholm score for functional assessment, and patient's self-appraisal. RESULTS: Most of the complex bicondylar fractures follow a regular pattern in that the medial compartment is split in a mediolateral direction with a posteromedial main fragment, combined with various amounts of multifragmental lateral compartment depression. The technique introduced allows for accurate and stable reduction and fixation of this fracture type. The final Lysholm knee score showed an average of 83.5 points (range: 64.5-92). CONCLUSIONS: Complex bicondylar tibial plateau fractures follow a regular pattern, which is not represented in existing 2-dimensional fracture classifications. A 2-incision technique starting with the reduction of the posteromedial edge results in accurate fracture reduction with low complication rates and excellent knee function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extended lateral L-shaped approach for the treatment of displaced intra-articular fractures of the calcaneum may be complicated by wound infection, haematoma, dehiscence and injury to the sural nerve. In an effort to reduce the risk of problems with wound healing a technique was developed that combined open reduction and fixation of the joint fragments and of the anterior process with percutaneous reduction and screw fixation of the tuberosity. A group of 24 patients with unilateral isolated closed Sanders type II and III fractures was treated using this technique and compared to a similar group of 26 patients managed by the extended approach and lateral plating. The operation was significantly shorter (p < 0.001) in the first group, but more minor secondary procedures and removal of heel screws were necessary. There were no wound complications in this group, whereas four minor complications occurred in the second group. The accuracy and maintenance of reduction, and ultimate function were equivalent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To present the functional and radiographic outcome 1 and 6 years after application of a new intramedullary fixation device for proximal humerus fractures. DESIGN: Retrospective case series. SETTING: Level II orthopaedic surgery hospital. PATIENTS: Twenty-six consecutive patients (average age 68.9 years) with 2-, 3- and 4-part fractures of the proximal humerus were operated at a single institution. Follow-up was performed after 1 year (26 patients) and 6 years (16 patients). INTERVENTION: All patients were treated with closed reduction and intramedullary helix wires. MAIN OUTCOME MEASUREMENTS: The Constant-Murley score and the University of California Los Angeles (UCLA) score. Clinical complications and radiological posttraumatic arthritis were recorded. RESULTS: The average Constant-Murley score was 70.3 (points) and 70.7 after 1 and 6 years, respectively; the average UCLA score was 27.2 and 31.5 after 1 and 6 years, respectively. Major complications were 4 revisions for 3 secondary fragment displacements and 1 nonunion with partial avascular osteonecrosis in the first postoperative year. Complications were found predominantly in 4-part fractures (3/5, 60%). There were no further complications or progressive posttraumatic arthritis up to 6 years following surgery. CONCLUSION: The helix wire is well suited for displaced or unstable 2- and 3-part proximal humerus fractures. Adequate functional outcome, a low number of implant displacements, a low number of application morbidity, and infrequent implant removals were recorded. The use of this device is not recommended for 4-part fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to use advanced MR techniques to evaluate and compare cartilage repair tissue after matrix-associated autologous chondrocyte transplantation (MACT) in the patella and medial femoral condyle (MFC). Thirty-four patients treated with MACT underwent 3-T MRI of the knee. Patients were treated on either patella (n = 17) or MFC (n = 17) cartilage and were matched by age and postoperative interval. For morphological evaluation, the MR observation of cartilage repair tissue (MOCART) score was used, with a 3D-True-FISP sequence. For biochemical assessment, T2 mapping was prepared by using a multiecho spin-echo approach with particular attention to the cartilage zonal structure. Statistical evaluation was done by analyses of variance. The MOCART score showed no significant differences between the patella and MFC (p > or = 0.05). With regard to biochemical T2 relaxation, higher T2 values were found throughout the MFC (p < 0.05). The zonal increase in T2 values from deep to superficial was significant for control cartilage (p < 0.001) and cartilage repair tissue (p < 0.05), with an earlier onset in the repair tissue of the patella. The assessment of cartilage repair tissue of the patella and MFC afforded comparable morphological results, whereas biochemical T2 values showed differences, possibly due to dissimilar biomechanical loading conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural deformities of the femoral head occurring during skeletal development (eg, Legg-Calvé-Perthes disease) are associated with individual shapes of the acetabulum but it is unclear whether differences in acetabular shape are associated with differences in proximal femoral shape. We questioned whether the amount of acetabular coverage influences femoral morphology. We retrospectively compared the proximal femoral anatomy of 50 selected patients (50 hips) with developmental dysplasia of the hip (lateral center-edge angle [LCE] < or = 25 degrees ; acetabular index > or = 14 degrees ) with 45 selected patients (50 hips) with a deep acetabulum (LCE > or = 39 degrees ). Using MRI arthrography we measured head sphericity, epiphyseal shape, epiphyseal extension, and femoral head-neck offset. A deep acetabulum was associated with a more spherical head shape, increased epiphyseal height with a pronounced extension of the epiphysis towards the femoral neck, and an increased offset. In contrast, dysplastic hips showed an elliptical femoral head, decreased epiphyseal height with a less pronounced extension of the epiphysis, and decreased head-neck offset. Hips with different acetabular coverage are associated with different proximal femoral anatomy. A nonspherical head in dysplastic hips could lead to joint incongruity after an acetabular reorientation procedure. LEVEL OF EVIDENCE: Level IV, retrospective comparative study. See the Guidelines for Authors for a complete description of levels of evidence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Percutaneous Kirschner wire fixation represents the classic treatment for displaced supracondylar humeral fractures in childhood. This type of treatment first requires satisfactory reduction of the fracture. Failure to achieve a satisfactory reduction or inadequate stabilization can result in instability of the fracture fragments, which can result in either an unsatisfactory cosmetic or functional outcome. In our experience, these problems can be overcome with the use of a small lateral external fixator. METHODS: Between 1999 and 2005, thirty-one of 170 Gartland type-III supracondylar humeral fractures were treated with a lateral external fixator. The outcome of treatment was analyzed with regard to limb alignment, elbow movement, cosmetic appearance, and patient satisfaction. RESULTS: In twenty-eight of the thirty-one patients, a satisfactory reduction was achieved with closed methods. All children except one had a normal or good range of movement. The cosmetic result was excellent in all cases. All of the children and their parents stated that they would choose this treatment again. CONCLUSIONS: The use of a small lateral external fixator seems to be a safe alternative for the treatment of displaced supracondylar fractures of the humerus when a closed reduction appears to be unattainable by means of manipulation alone or when sufficient stability is not achieved with standard methods of Kirschner wire fixation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Open skull fractures have been traditionally managed in 2 stages: urgent craniotomy and elevation of the fracture with removal of contaminated bone, debridement, and delayed cranioplasty. Primary, single-stage repair of these injures has been said to entail risks such as infections. Recent experience, however, disproved these concerns.We used a primary single-stage reconstruction for patients presenting with open depressed skull fractures. All patients received antibiotic prophylaxis. The patients underwent elevation of the compound fracture and craniotomy if necessary. Debridement was performed, followed by skull reconstruction using a 0.6-mm titanium mesh.We present 5 consecutive male patients (age, 32.2 +/- 15.6 years) who underwent primary reconstruction of open depressed skull fractures. Clinical and radiologic follow-up was performed 2 months after surgery. The duration of the surgery was 2 +/- 1.6 hours. The size of the implanted mesh was 13 +/- 13.1 cm. No infection was detected in our series, with a follow-up period of 22 +/- 6.5 months (range, 16-29 months). The cosmetic result was defined in 4 patients as "excellent" and in 1 patient as "good."Primary reconstruction of open skull fractures with titanium mesh is feasible, safe, and cosmetically preferable than the conventional staged approach. The introduction into clinical practice can be warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessment of regional blood flow changes is difficult in the clinical setting. We tested whether conventional pulmonary artery catheters (PACs) can be used to measure regional venous blood flows by inverse thermodilution (ITD). Inverse thermodilution was tested in vitro and in vivo using perivascular ultrasound Doppler (USD) flow probes as a reference. In anesthetized pigs, PACs were inserted in jugular, hepatic, renal, and femoral veins, and their measurements were compared with simultaneous USD flow measurements from carotid, hepatic, renal, and femoral arteries and from portal vein. Fluid boluses were injected through the PAC's distal port, and temperature changes were recorded from the proximally located thermistor. Injectates of 2 and 5 mL at 22 degrees C and 4 degrees C were used. Flows were altered by using a roller pump (in vitro), and infusion of dobutamine and induction of cardiac tamponade, respectively. In vitro: At blood flows between 400 mL . min-1 and 700 mL . min-1 (n = 50), ITD and USD correlated well (r = 0.86, P < 0.0001), with bias and limits of agreement of 3 +/- 101 mL . min-1. In vivo: 514 pairs of measurements had to be excluded from analysis for technical reasons, and 976 were analyzed. Best correlations were r = 0.87 (P < 0.0001) for renal flow and r = 0.46 (P < 0.0001) for hepatic flow. No significant correlation was found for cerebral and femoral flows. Inverse thermodilution using conventional PAC compared moderately well with USD for renal but not for other flows despite good in vitro correlation in various conditions. In addition, this method has significant technical limitations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the auditory ossicles are difficult to display without harming them in conventional autopsies, lesions of these minute bones and the ossicular chain are regularly missed. In this study, the method of choice in clinical medicine for the examination of such lesions, namely multislice computed tomography, was applied to 100 corpses. The hereby obtained results regarding ossicle luxation and petrous bone fracture indicated that the lesions were not dependant on the amount, but rather on the type of energy inflicted to the head.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To review the epidemiology of facial fractures in children and to analyze whether it has changed over time. STUDY DESIGN: Retrospective review of records of children aged < or = 15 years diagnosed for fracture during 2 10-year periods. RESULTS: A total of 378 children were diagnosed with fractures, 187 in 1980-1989 and 191 in 1993-2002. The proportion of children with mandibular fractures decreased by 13.6 percentage-points from the first period to the second, whereas the proportion of patients with midfacial fractures increased by 18.7 percentage-points. Assault as a causative factor increased by 5.5 percentage-points, almost exclusively among children aged 13-15 years, with a high percentage (23.5%). CONCLUSIONS: Recognition of a change in fracture patterns over time is probably due to the increased use of computerized tomographic scanning.