865 resultados para Enhanced radiography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The aim of this study was to detect the development of experimentally induced periapical lesions using conventional radiography and computed tomography.Study design. The root canals of dogs' teeth were exposed to the oral environment for 7 days for contamination and then sealed for 7 days (GI), 15 days (GII), 30 days (GIII), and 60 days (GIV). Immediately after each experimental period, radiographs and tomograms were taken in order to detect the occurrence of periapical bone resorption. The periapical radiographs were digitized and areas of bone resorption were measured using the VIXWIN 2000 software. Scores were assigned to the tomograms based on the progression of periapical bone resorption. The specimens were evaluated by calibrated examiners who were blinded to the groups. The radiographic results were analyzed by ANOVA and Tukey's test (P <.05) and the tomographic results were analyzed by Kruskal-Wallis and Dunn's tests (P <.05).Results. The radiographic evaluation did not reveal periapical lesions at the 7-day control. Lesions were radiographically visible at 15 and 30 days (47.4% and 77.8% of the cases, respectively) and presented similar dimensions (P <.05). At 60 days, lesions were detected in all specimens, presenting larger dimensions than those of the earlier evaluation periods (P <.05). The tomographic evaluation detected lesions at 7 and 15 days (32.5% and 83.3% of the cases, respectively). Lesions were detected in all specimens at the 30- and 60-day periods, when the greatest values of bone resorption were observed (P <.05).Conclusions. Tomography was able to detect periapical lesion development in its initial stages, even when the lesions were undetectable radiographically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to describe a new technique by using Adobe Photoshop CS (San Jose, CA) image-analysis software to evaluate the radiographic changes of chronic periapical lesions after root canal treatment by digital subtraction radiography. Thirteen upper anterior human teeth with pulp necrosis and radiographic image of chronic periapical lesion were endodontically treated and radiographed 0, 2, 4, and 6 months after root canal treatment by using a film holder. The radiographic films were automatically developed and digitized. The radiographic images taken 0, 2, 4, and 6 months after root canal therapy were submitted to digital subtraction in pairs (0 and 2 months, 2 and 4 months, and 4 and 6 months) choosing image, calculation, subtract, and new document tools from Adobe Photoshop CS image-analysis software toolbar. The resulting images showed areas of periapical healing in all cases. According to this methodology, the healing or expansion of periapical lesions can be evaluated by means of digital subtraction radiography by using Adobe Photoshop CS software.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to investigate the in vivo and in vitro reactivity of airway smooth muscle in rats depleted of sensory neuropeptides by treatment with capsaicin at neonatal stage. Wistar rats were neonatally injected with either capsaicin (50 mg/kg, s.c., 2nd day of life) or its vehicle (10% ethanol and 10% Tween 80, in 0.9% w/v NaCl solution) and used at adult ages (60-70 days later). Analysis of the lungs showed a higher number of infiltrating neutrophils, eosinophils and mononuclear cells into the peribronchiolar regions of capsaicin-pretreated rats compared to vehicle group. This was associated with a higher contraction index of bronchiolar wall in the capsaicin group. The in vitro tracheal reactivity in response to methacholine (full muscarinic agonist) and pilocarpine (partial muscarinic agonist) was also significantly higher in capsaicin-pretreated rats compared to vehicle group. In conclusion, the neuropeptide depletion by capsaicin neonatal treatment lead to marked contraction of the rat airways at adult age, suggesting a protective role for C fibers in the lungs. (C) 2003 Elsevier B.V. Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Root resorption can cause damage in orthodontic patients. Digital subtraction radiography (DSR) is a useful resource for the detection of mineral losses. The purpose of this study was to compare the efficacy of digital radiography (DR) and DSR in detecting simulated external root resorption. Examiner agreement between the 2 techniques was also evaluated. Methods: Root resorptions of various sizes were simulated on the apical and lingual aspects of 49 teeth from 9 dry human mandibles. The teeth were radiographed in standardized conditions. The radiographs were registered with Regeemy Image Registration and Mosaicking (version 0.2.43-RCB, DPI-INPE, Sao Jose dos Campos, São Paulo, Brazil) and subtracted with Image Tool (University of Texas Health Science Center at San Antonio). The subtracted images and the digital radiographs were evaluated by 3 oral radiologists. Results: No statistically significant differences were found for the methods in the detection of apical root resorptions, independently from lesion size, and of lingual resorptions of 1.2 mm or greater. DSR was significantly better than DR for detection of lingual resorptions up to 1 mm. Resorptions less than 0.5 mm were not precisely detected by either method. DSR provided better intraexaminer and interexaminer agreement than did DR. Conclusions: Both methods are precise for detection of apical root resorptions as small as 0.5 mm and lingual resorptions of 1 mm or more. However, DSR frequently performed better than did DR. (Am J Orthod Dentofacial Orthop 2011;139:324-33)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for improving the accuracy of surface shape measurement by multiwavelength holography is presented. In our holographic setup, a Bi12TiO20 photorefractive crystal was the holographic recording medium, and a multimode diode laser emitting in the red region was the light source in a two-wave mixing scheme. on employing such lasers the resulting holographic image appears covered with interference fringes corresponding to the object relief, and the interferogram spatial frequency is proportional to the diode laser's free spectral range (FSR). Our method consists in increasing the effective free spectral range of the laser by positioning a Fabry-Perot etalon at the laser output for mode selection. As larger effective values of the laser FSR were achieved, higher-spatial-frequency interferograms were obtained and therefore more sensitive and accurate measurements were performed. The quantitative evaluation of the interferograms was made through the phase-stepping technique, and the phase map unwrapping was carried out through the cellular-automata method. For a given surface, shape measurements with different interferogram spatial frequencies were performed and compared with respect to measurement noise and visual inspection. (c) 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies have demonstrated that the sheath dynamics in plasma immersion ion implantation (PIII) is significantly affected by an external magnetic field. In this paper, a two-dimensional computer simulation of a magnetic-field-enhanced PHI system is described. Negative bias voltage is applied to a cylindrical target located on the axis of a grounded vacuum chamber filled with uniform molecular nitrogen plasma. A static magnetic field is created by a small coil installed inside the target holder. The vacuum chamber is filled with background nitrogen gas to form a plasma in which collisions of electrons and neutrals are simulated by the Monte Carlo algorithm. It is found that a high-density plasma is formed around the target due to the intense background gas ionization by the magnetized electrons drifting in the crossed E x B fields. The effect of the magnetic field intensity, the target bias, and the gas pressure on the sheath dynamics and implantation current of the PHI system is investigated.