949 resultados para Efficiency of cleaning


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article presents results of an experimental investigation on the resistance to chemical attack (with sulphuric, hydrochloric and nitric acid) of several materials: OPC concrete, high-performance concrete, epoxy resin, acrylic painting and a fly ash-based geopolymeric mortar). Three types of acids with three high concentrations (10, 20 and 30%) were used to simulate long-term degradation. A cost analysis was also performed. The results show that the epoxy resin has the best resistance to chemical attack independently of the acid type and the acid concentration. However, the cost analysis shows that the epoxy resin-based solution is the least cost-efficient solution being 70% above the cost efficiency of the fly ash-based geopolymeric mortar.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays cities are facing several environmental problems due to the population migration to urban areas, which is causing urban sprawl. This way, it is very important to define solutions to improve Land Use Efficiency (LUE). This article proposes the use of community buildings features as a solution to increase land use efficiency. Community buildings consider the design of shared building spaces to reduce the floor area of buildings. This work tests the performance of some case-study buildings regarding LUE to analyse its possible pros and cons. A quantifiable method is used to assess buildingsâ LUE, which considers the number of occupants, the gross floor area, the functional area, the implantation area and the allotment area. Buildings with higher values for this index have reduced environmental impacts because they use less construction materials, produce less construction and demolition wastes and require less energy for building operation. The results showed that the use of community building features can increase Land Use Efficiency of buildings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tese de Doutoramento em Engenharia Civil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are presently over 182 RBC plants, treating domestic wastewater, in the Republic of Ireland, 136 of which have been installed since 1986. The use of this treatment plant technology, although not new, is becoming increasingly popular. The aim of this research was to assess the effects that a household detergent has on rotating biological contractor treatment plant efficiency. Household detergents contribute phosphorus to the surrounding environment and can also remove beneficial biomass from the disc media. A simple modification was made to a conventional flat disc unit to increase the oxygen transfer of the process. The treatment efficiency of the modified RBC (with aeration cups attached) was assessed against a parallel conventional system, with and without degergent loading. The parameters monitored were chemical oxygen demand (COD), bio-chemical oxygen demand (BOD), nitrates, phosphates, dissolved oxygen, the motors power consumption, pH, and temperature. Some microscopic analysis of the biofilm was also to be carried out. The treatment efficiency of both units was compared, based on COD/BOD removal. The degree of nitrification achievable by both units was also assessed with any fluctuations in pH noted. Monitoring of the phosphorus removal capabilities of both units was undertaken. Relationships between detergent concentrations and COD removal efficiencies were also analysed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose - This paper focuses on analyzing the effect that public reforms have on the efficiency of state-owned enterprises in regulated environments. Design/methodology/approach - The research is focused in the postal sector where public and private companies must obey a legal framework related to provide a universal service. The analysis is carried out using a panel of 7 European postal operators for the period 1997-2003. The activity analyzed was the letter mail division; we take as key variable the unit cost of a letter and use a translog cost function where as independent variables we include traffic levels, labor cost per employee, quality and availability of the service as well as the type of ownership (public or private). Additionally, in a second stage the geographical differences among countries are considered. Findings - Results indicate that postal operators that experienced organizational changes without being privatized, such as the Spanish and Greek operators, do not have higher unit costs than privatized postal operators like the one of Germany and the Netherlands. Moreover, we find that in all cases the operator of Ireland appear to be the most efficient. In this case restructuring process has been carried out giving an important leadership role to workers. This suggests us that labor culture could be a key variable to study when analyzing reform processes in public enterprises. Originality/value - Our findings show that in a regulated environment like in the postal sector, public and private companies can obtain similar efficiency levels in term of unit costs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this report, the efficiency of Adultrap under field conditions is compared to a CDC backpack aspirator and to MosquiTRAP. An urban dengue-endemic area of Rio de Janeiro was selected to evaluate the efficiency of mosquito traps in capturing Aedes aegypti females. Adultrap and aspirator captured similar numbers of Ae. aegypti females, with the former showing high specificity to gravid individuals (93.6%). A subsequent mark-release-recapture experiment was conducted to evaluate Adultrap and MosquiTRAP efficiency concomitantly. With a 6.34% recapture rate, MosquiTRAP captured a higher mean number of female Ae. aegypti per trap than Adultrap (Ç2 = 14.26; df = 1; p < 0,05). However, some MosquiTRAPs (28.12%) contained immature Ae. aegypti after 18 days of exposure in the field and could be pointed as an oviposition site for female mosquitoes. Both trapping methods, designed to collect gravid Ae. aegypti females, seem to be efficient, reliable and may aid routine Ae. aegypti surveillance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Genetic diversity might increase the performance of social groups by improving task efficiency or disease resistance, but direct experimental tests of these hypotheses are rare. We manipulated the level of genetic diversity in colonies of the Argentine ant Linepithema humile, and then recorded the short-term task efficiency of these experimental colonies. The efficiency of low and high genetic diversity colonies did not differ significantly for any of the following tasks: exploring a new territory, foraging, moving to a new nest site, or removing corpses. The tests were powerful enough to detect large effects, but may have failed to detect small differences. Indeed, observed effect sizes were generally small, except for the time to create a trail during nest emigration. In addition, genetic diversity had no statistically significant impact on the number of workers, males and females produced by the colony, but these tests had low power. Higher genetic diversity also did not result in lower variance in task efficiency and productivity. In contrast to genetic diversity, colony size was positively correlated with the efficiency at performing most tasks and with colony productivity. Altogether, these results suggest that genetic diversity does not strongly improve short-term task efficiency in L. humile, but that worker number is a key factor determining the success of this invasive species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The net mechanical efficiency of positive work (eta(pos)) has been shown to increase if it is immediately preceded by negative work. This phenomenon is explained by the storage of elastic energy during the negative phase and its release during the subsequent positive phase. If a transition time (T) takes place, the elastic energy is dissipated into heat. The aim of the present study was to investigate the relationship between eta(pos) and T, and to determine the minimal T required so that eta(pos) reached its minimal value. Seven healthy male subjects were tested during four series of lowering-raising of the body mass. In the first series (S (0)), the negative and positive phases were executed without any transition time. In the three other series, T was varied by a timer (0.12, 0.24 and 0.56 s for series S (1), S (2) and S (3), respectively). These exercises were performed on a force platform sensitive to vertical forces to measure the mechanical work and a gas analyser was used to determine the energy expenditure. The results indicated that eta(pos) was the highest (31.1%) for the series without any transition time (S (0)). The efficiencies observed with transition times (S (1), S (2) and S (3)) were 27.7, 26.0 and 23.8%, respectively, demonstrating that T plays an important role for mechanical efficiency. The investigation of the relationship between eta(pos) and T revealed that the minimal T required so that eta(pos) reached its minimal value is 0.59 s.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to losses caused by water erosion, the development of techniques that increase the efficiency of soil conservation practices is fundamental. Terracing of agricultural lands is an important conservation practice. Bearing in mind that improperly built terraces may negatively affect the landscape, the purpose of this work was to evaluate the efficiency as well as the adequacy of retention terraces. Assessments were performed in four terraces implanted in different states, all located in the mideastern region of the state of Minas Gerais. The water storage efficiency of the terraces was determined by comparing the effective with the required storage capacity, as established in the project. Proposals were also made for the adequacy of the assessed terraces, based on the correction of the characteristics that jeopardized storage efficiency. The storage efficiency of three of the four assessed terraces was below the required levels (0.5-13 %). The main properties influencing storage capacity were: uniformity of ridge crest height, terrace end closure, and the cross section finishing. In two of the three low-efficiency terraces, the correction of these characteristics proved sufficient to raise the storage efficiency to nearly 100 %.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Generally, in tropical and subtropical agroecosystems, the efficiency of nitrogen (N) fertilization is low, inducing a temporal variability of crop yield, economic losses, and environmental impacts. Variable-rate N fertilization (VRF), based on optical spectrometry crop sensors, could increase the N use efficiency (NUE). The objective of this study was to evaluate the corn grain yield and N fertilization efficiency under VRF determined by an optical sensor in comparison to the traditional single-application N fertilization (TSF). With this purpose, three experiments with no-tillage corn were carried out in the 2008/09 and 2010/11 growing seasons on a Hapludox in South Brazil, in a completely randomized design, at three different sites that were analyzed separately. The following crop properties were evaluated: aboveground dry matter production and quantity of N uptake at corn flowering, grain yield, and vegetation index determined by an N-Sensor® ALS optical sensor. Across the sites, the corn N fertilizer had a positive effect on corn N uptake, resulting in increased corn dry matter and grain yield. However, N fertilization induced lower increases of corn grain yield at site 2, where there was a severe drought during the growing period. The VRF defined by the optical crop sensor increased the apparent N recovery (NRE) and agronomic efficiency of N (NAE) compared to the traditional fertilizer strategy. In the average of sites 1 and 3, which were not affected by drought, VRF promoted an increase of 28.0 and 41.3 % in NAE and NRE, respectively. Despite these results, no increases in corn grain yield were observed by the use of VRF compared to TSF.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this work was to evaluate an inventory method efficiency for ants. We used subsamples collected in 24 transects of 100 m, distributed in 6 plots of 600 ha each in primary forest, as part of a long-term project. Ten litter subsamples were extracted per transect using Winkler extractors. Ants were identified to genus level, and Crematogaster, Gnamptogenys and Pachycondyla genera to species/morphospecies level. To evaluate the consequences of reduced sampling on the retention of ecological information, we estimated the lowest number of subsamples needed to detect the effects of environmental variables. Multidimensional scaling (MDS) was used to generate dissimilarity matrices, and Mantel correlations between each reduced-sampling effort and maximum effort were used as an index of how much information was maintained and could still be used in multivariate analyses. Lower p-values was observed on the effect of soil pH in the community of genera, and on the effect of the litter volume for the community of Crematogaster. The trend was still detectable in the analysis based on reduced-sampling. The number of subsamples can be reduced, and the cost-efficiency of the protocol can be improved with little loss of information.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Professional cleaning is a basic service occupation with a wide variety of tasks carried out in all kind of different sectors and workplaces by a large workforce. One important risk for cleaning workers is the exposure to chemical substances that are present in cleaning products.Monoethanolamine was found to be often present in cleaning products such as general purpose cleaners, bathroom cleaners, floor cleaners and kitchen cleaners. Monoethanolamine can injure the skin, and exposure to monoethanolamine was associated to asthma even when the air concentrations were low. It is a strong irritant and known to be involved in sensitizing mechanisms. It is very likely that the use of cleaning products containing monoethanolamine gives rise to respiratory and dermal exposures. Therefore there is a need to further investigate the exposures to monoethanolamine for both, respiratory and dermal exposure.The determination of monoethanolamine has traditionally been difficult and analytical methods available are little adapted for occupational exposure assessments. For monoethanolamine air concentrations, a sampling and analytical method was already available and could be used. However, a method to analyses samples for skin exposure assessments as well as samples of skin permeation experiments was missing. Therefore one main objective of this master thesis was to search an already developed and described analytical method for the measurement of monoethanolamine in water solutions, and to set it up in the laboratory. Monoethanolamine was analyzed after a derivatisation reaction with o-pthtaldialdehyde. The derivated fluorescing monoethanolamine was then separated with high performance liquid chromatography and detection took place with a fluorescent detector. The method was found to be suitable for qualitative and quantitative analysis of monoethanolamine. An exposure assessment was conducted in the cleaning sector to measure the respiratory and dermal exposures to monoethanolamine during floor cleaning. Stationary air samples (n=36) were collected in 8 companies and samples for dermal exposures (n=12) were collected in two companies. Air concentrations (Mean = 0.18 mg/m3, Standard Deviation = 0.23 mg/m3, geometric Mean = 0.09 mg/m3, Geometric Standard Deviation = 3.50) detected were mostly below 1/10 of the Swiss 8h time weighted average occupational exposure limit. Factors that influenced the measured monoethanolamine air concentrations were room size, ventilation system and the concentration of monoethanolamine in the cleaning product and amount of monoethanolamine used. Measured skin exposures ranged from 0.6 to 128.4 mg/sample. Some cleaning workers that participated in the skin exposure assessment did not use gloves and had direct contact with the solutions containing the cleaning product and monoethanolamine. During the entire sampling campaign, cleaning workers mostly did not use gloves. Cleaning workers are at risk to be regularly exposed to low air concentrations of monoethanolamine. This exposure may be problematic if a worker suffers from allergic reactions (e.g. Asthma). In that case a substitution of the cleaning product may be a good prevention measure as several different cleaning products are available for similar cleaning tasks. Currently there are no occupational exposure limits to compare the skin exposures that were found. To prevent skin exposures, adaptations of the cleaning techniques and the use of gloves should be considered. The simultaneous skin and airborne exposures might accelerate adverse health effects. Overall the risks caused by exposures to monoethanolamine are considered as low to moderate when the cleaning products are used correctly. Whenever possible, skin exposures should be avoided. Further research should consider especially the dermal exposure routes, as very high exposures might occur by skin contact with cleaning products. Dermatitis but also sensitization might be caused by skin exposures. In addition, new biomedical insights are needed to better understand the risks of the dermal exposure. Therefore skin permeability experiments should be considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tämän työn tarkoituksena oli selvittää mekaanisen massan valmistuksen käsittävän paperitehtaan rejektija jätevirtojen poltettavuutta, jos paperitehtaan vesikiertojen sulkemisastetta lisätään. Jotta prosessin tilannetta sulkemisen jälkeen saatiin arvioitua, Anjalan paperitehtaan nykypäivän PK3:n prosessia tutkittiin kuorimolta jätevesilaitokselle. Kirjallisuusosassa käsiteltiin rejekti- ja jätevirtojen alkuperää mekaanista massaa käyttävässä paperitehtaassa. Myös tämän päivän jätevedenkäsittelyprosessit sekä sulkemisessa mahdolliset prosessiveden puhdistustekniikat esiteltiin lyhyesti. Lisäksikäytiin läpi nykypäivänä metsäteollisuudessa käytössä olevat polttotekniikat sekä polttoaineiden karakterisointi kattilan käytettävyyden ja päästöjen kannalta. Anjalan PK3:lla käytetään sekä peroksidi- että ditioniittivalkaistua tai pelkästään ditioniittivalkaistua hioketta riippuen tuotannossa olevasta lajista. PK3-prosessissa syntyneet jätevesi-, liete- ja muut jätevirrat selvitettiin molemmissa valkaisuolosuhteissa. Prosessin eniten liuennutta orgaanista ainesta sisältävät jätevesijakeet, 3-hiomon kuumankierron ja kirkassuodoksen ulosajot sekä kuoripuristimen suodos, valittiin puhdistettaviksi virroiksi prosessin sulkemista arvioitaessa. Kun peroksidivalkaisua käytettiin 3-hiomolla, TOC-kuorma jokeen oli 30 % suurempi kuin pelkällä ditioniittivalkaisulla. Jos prosessin sulkemisastetta lisättäisiin, TOC-kuorma olisi 30 %pienempi kuin tänäpäivänä peroksidivalkaisua käytettäessä (80 % puhdistustehokkuudella). Prosessin sulkemisastetta lisättäessä biolietettä muodostuisi n. 30 % vähemmän verrattuna nykytilanteeseen, sillä mikrobien ravintona käyttämää orgaanista ainesta päätyisi vähemmän jäteveteen. 3-hiomon peroksidivalkaisun vaikutus kattilan käytettävyyteen ja päästöihin oli pieni, sillä biolietteen osuus polttoaineen syötöstä oli vain 4 %. Vain osa biolietteestä muodostui 3-hiomolta peräisin olevaa orgaanista ainesta poistettaessa. Jos nykyisen pääpolttoaineen, PDF:n,osuuden jättää huomioimatta, SO2- ja NOx-päästöt sekä leijupedin sintrautuvuus ovat hiukan suuremmat käytettäessä peroksidivalkaisua 3-hiomolla kuin pelkästään ditioniittivalkaisulla. Jos kuoripuristimen ja hiomon suodosten puhdistuksen konsentraatit johdetaan poltettaviksi BFB-tyyppiseen kattilaan, leijupedin sintrautuminen tulisi olemaan suurin ongelma. Myös raskasmetalli-, SO2- ja NOx-päästöt lisääntyisivät merkittävästi verrattuna nykyiseen tilanteeseen. Sen sijaan kattilan korroosioriski tuskin lisääntyisi. Lisäksi konsentraattien kosteuspitoisuus olisi korkea, mikä tekisi poltosta kannattamatonta veden haihdutuksen vaatiessa paljon energiaa. Yksityiskohtaisempaa tutkimusta tarvitaan vielä prosessin sulkemisen vaikutuksista päästöihin ja kattilan käytettävyyteen. Myös muita konsentraattien hävittämismahdollisuuksia tulisi tutkia lisää.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this thesis was to produce information for the estimation of the flow balance of wood resin in mechanical pulping and to demonstrate the possibilities for improving the efficiency of deresination in practice. It was observed that chemical changes in wood resin take place only during peroxide bleaching, a significant amount of water dispersed wood resin is retained in the pulp mat during dewatering and the amount of wood resin in the solid phase of the process filtrates is very small. On the basis of this information there exist three parameters related to behaviour of wood resin that determine the flow balance in the process: 1. The liberation of wood resin to the pulp water phase 2. Theretention of water dispersed wood resin in dewatering 3. The proportion of wood resin degraded in the peroxide bleaching The effect of different factors on these parameters was evaluated with the help of laboratory studies and a literature survey. Also, information related to the values of these parameters in existing processes was obtained in mill measurements. With the help of this information, it was possible to evaluate the deresination efficiency and the effect of different factors on this efficiency in a pulping plant that produced low-freeness mechanical pulp. This evaluation showed that the wood resin content of mechanical pulp can be significantly decreased if there exists, in the process, a peroxide bleaching and subsequent washing stage. In the case of an optimal process configuration, as high as a 85 percent deresination efficiency seems to be possible with a water usage level of 8 m3/o.d.t.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose The purpose of this paper is (1) to measure school technical efficiency and (2) to identify the determinants of primary school performance. Design/methodology/approach A two-stage Data Envelopment Analysis (DEA) of school efficiency is conducted. At the first stage, DEA is employed to calculate an individual efficiency score for each school. At the second stage, efficiency is regressed on school characteristics and environmental variables. Findings The mean technical efficiency of schools in the State of Geneva is equal to 93%. By improving the operation of schools, 7% (100 - 93) of inputs could be saved, representing 17'744'656.2 Swiss francs in 2010. School efficiency is negatively influenced by (1) operations being held on multiple sites, (2) the proportion of disadvantaged pupils enrolled at the school and (3) the provision of special education, but positively influenced by school size (captured by the number of pupils). Practical implications Technically, the determinants of school efficiency are outside of the control of the headteachers. However, it is still possible to either boost the positive impact or curb the negative impact. Potential actions are discussed. Originality/value Unlike most similar studies, the model in this study is tested for multicollinearity, heteroskedasticity and endogeneity. It is therefore robust. Moreover, one explanatory variable of school efficiency (operations being held on multiple sites) is a truly original variable as it has never been tested so far.