970 resultados para EQUIPMENT CONTAMINATION
Resumo:
The aim of this work is to develop a software that allows the inspection of spur gear manufactured in the sub-millimeter range. The measurements are made using a digital optical machine and using an analysis proprietary software implemented in Matlab®, which is able to handle images, captured using the digital optical machine. The software allows to evaluate the profile and pitch deviations as establish in the ISO/TR 10064-1:1992 standard
Resumo:
This paper proposes a method for the identification of different partial discharges (PDs) sources through the analysis of a collection of PD signals acquired with a PD measurement system. This method, robust and sensitive enough to cope with noisy data and external interferences, combines the characterization of each signal from the collection, with a clustering procedure, the CLARA algorithm. Several features are proposed for the characterization of the signals, being the wavelet variances, the frequency estimated with the Prony method, and the energy, the most relevant for the performance of the clustering procedure. The result of the unsupervised classification is a set of clusters each containing those signals which are more similar to each other than to those in other clusters. The analysis of the classification results permits both the identification of different PD sources and the discrimination between original PD signals, reflections, noise and external interferences. The methods and graphical tools detailed in this paper have been coded and published as a contributed package of the R environment under a GNU/GPL license.
Resumo:
The need for the use of another surveillance system when radar cannot be used is the reason for the development of the Multilateration (MLT) Systems. However, there are many systems that operate in the L-Band (960-1215MHz) that could produce interference between systems. At airports, some interference has been detected between transmissions of MLT systems (1030MHz and 1090MHz) and Distance Measuring Equipment (DME) (960-1215MHz).
Resumo:
This work focuses on the analysis of a structural element of MetOP-A satellite. Given the special interest in the influence of equipment installed on structural elements, the paper studies one of the lateral faces on which the Advanced SCATterometer (ASCAT) is installed. The work is oriented towards the modal characterization of the specimen, describing the experimental set-up and the application of results to the development of a Finite Element Method (FEM) model to study the vibro-acoustic response. For the high frequency range, characterized by a high modal density, a Statistical Energy Analysis (SEA) model is considered, and the FEM model is used when modal density is low. The methodology for developing the SEA model and a compound FEM and Boundary Element Method (BEM) model to provide continuity in the medium frequency range is presented, as well as the necessary updating, characterization and coupling between models required to achieve numerical models that match experimental results.
Resumo:
Damages -reduced in fruit packing lines is a major cause of grace reduction and quality loos in fresh marks: fruit. Fruit must be treated gently during in sir handling to improve their qualityin order to get a good price in a competitive market. The correct post-hardvest handling in fruit packing lines is a prerequisite to cut down the heavy post-harvest losses. Fruit packing lines must be evaluated, studying their design, the impacts applied to the fruits, the characteristics of the materials, etc. This study establishes the possibility of carrying out modifications and tests in a packing line during a long period of time. For this purpose, an experimental fruit packing line has been designed and located in the Agricultural Engineering Department of the Polythecnic University of Madrid with the aim of improving mechanical devices and fruit handling conditions to minimize damage to fruit. The experimental line consists of several transporting belts, one rollers transporter, one sizer, one elevator, one singularizer, and three trays to receive the calibrated fruit. The line has a length of 6.15 m and a width cf 1.9 m. Movement of the different components is regulated by electric motors with variable velocity electronically controlled. The height of the transfer points is variable and can be easily modified. The experimental line has been calibrated using two instrumented spheres IS 100 (8.8 cm Ø and6.2cm Ø). Average acceleration values obtained in all the transfers of the experimental line lay under 80 g's, although there is big variation for some of them being some values above 100 g's.
Resumo:
Effects of considering the particle comminution rate -kc- in addition to particle rumen outflow -kp- and the ruminal microbial contamination on estimates of by-pass and intestinal digestibility of DM, organic matter and crude protein were examined in perennial ryegrass and oat hays. By-pass kc-kp-based values of amino acids were also determined. This study was performed using particle transit, in situ and 15N techniques on three rumen and duodenum-cannulated wethers. The above estimates were determined using composite samples from rumen-incubated residues representative of feed by-pass. Considering the comminution rate, kc, modified the contribution of the incubated residues to these samples in both hays and revealed a higher microbial contamination, consistently in oat hay and only as a tendency for crude protein in ryegrass hay. Not considering kc or rumen microbial contamination overvalued by-pass and intestinal digestibility in both hays. Therefore, non-microbial-corrected kp-based values of intestinal digested crude protein were overestimated as compared with corrected and kc-kp-based values in ryegrass hay -17.4 vs 4.40%- and in oat hay -5.73 vs 0.19%-. Both factors should be considered to obtain accurate in situ estimates in grasses, as the protein value of grasses is very conditioned by the microbial synthesis derived from their ruminal fermentation. Consistent overvaluations of amino acid by-pass due to not correcting microbial contamination were detected in both hays, with large variable errors among amino acids. A similar degradation pattern of amino acids was recorded in both hays. Cysteine, methionine, leucine and valine were the most degradation-resistant amino acids.
Resumo:
Effects of considering the comminution rate -kc- and the correction of microbial contamination -using 15N techniques- of particles in the rumen on estimates of ruminally undegraded fractions and their intestinal digestibility were examined generating composite samples -from rumen-incubated residues- representative of the undegraded feed rumen outflow. The study used sunflower meal -SFM- and Italian ryegrass hay -RGH- and three rumen and duodenum cannulated wethers fed with a 40:60 RGH to concentrate diet -75 g DM/kgBW0.75-. Transit studies up to the duodenum with Yb-SFM and Eu-RGH marked samples showed higher kc values -/h- in SFM than in RGH -0.577 vs. 0.0892, p = 0.034-, whereas similar values occurred for the rumen passage rate -kp-. Estimates of ruminally undegraded and intestinal digestibility of all tested fractions decreased when kc was considered and also applying microbial correction. Thus, microbial uncorrected kp-based proportions of intestinal digested undegraded crude protein overestimated those corrected and kc-kp-based by 39% in SFM -0.146 vs. 0.105- and 761% in RGH -0.373 vs. 0.0433-. Results show that both kc and microbial contamination correction should be considered to obtain accurate in situ estimates in grasses, whereas in protein concentrates not considering kc is an important source of error.