958 resultados para Cooling ponds


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We propose new theoretical models, which generalize the classical Avrami-Nakamura models. These models are suitable to describe the kinetics of nucleation and growth in transient regime, and/or with overlapping of nucleation and growth. Simulations and predictions were performed for lithium disilicate based on data reported in the literature. One re-examined the limitations of the models currently used to interpret DTA or DSC results, and to extract the relevant kinetic parameters. Glasses and glass-ceramics with molar formulation 0.45SiO2? (0.45-x)MgO?xK2O?0.1(3CaO.P2O5) (0?x?0.090) were prepared, crystallized and studied as potential materials for biomedical applications. Substitution of K+ for Mg2+ were used to prevent devritification on cooling, to adjust the kinetics of crystallization and to modify the in vitro behaviour of resulting biomaterials. The crystallization of the glass frits was studied by DTA, XRD and SEM. Exothermic peaks were detected corresponding to bulk crystallization of whitlockite-type phosphate, Ca9MgK(PO4)7, at approximately 900ºC, and surface crystallization of a predominant forsterite phase (Mg2SiO4) at higher temperatures. XRD also revealed the presence of diopside (CaMgSi2O6 in some samples. The predominant microstructure of the phosphate phase is of the plate-type, seemingly crystallizing by a 2-dimensional growth mechanism. Impedance spectroscopy revealed significant changes in electrical behaviour, associated to crystallization of the phosphate phase. This showed that electrical measurements can be used to study the kinetics of crystallization for cases when DTA or DSC experiments reveal limitations, and to extract estimates of relevant parameters from the dependence of crystallization peak temperature, and its width at half height. In vitro studies of glasses and glass-ceramics in acelular SBF media showed bioactivity and the development of apatite layers The morphology, composition and adhesion of the apatite layer could be changed by substitution of Mg2+ by K+. Apatite layers were deposited on the surface of glass-ceramics of the nominal compositions with x=0 and 0.09, in contact with SBF at 37ºC. The adhesion of the apatite layer was quantified by the scratch test technique, having been related with SBF?s immersion time, with composition and structure of the glass phase, and with the morphology of the crystalline phase of the glass-ceramics. The structure of three glasses (x=0, 0.045 and 0.090) were investigated by MAS-NMR ( 29Si and 31P), showing that the fraction of Q3 structural units increases with the contents of Mg, and that the structure of these glasses includes orthophosphate groups (PO43-) preferentially connected to Ca2+ ions. Mg2+ ions show preference towards the silicate network. Substitution of Mg2+ by K+ allowed one to change the bioactivity. FTIR data revealed octacalcium phosphate precipitation (Ca8H2(PO4)6.5H2O) in the glass without K, while the morphology of the layer acquires the shape of partially superimposed hemispheres, spread over the surface. The glasses with K present a layer of acicular hidroxyapatite, whose crystallinity and needles thickness tend to increase along with K content.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este estudo pretende analisar a influência do caudal de ar novo insuflado num edifício administrativo no desempenho energético do seu sistema AVAC. O RSECE determina os caudais mínimos de AN para renovação do ar interior e qualidade do ar aceitável em espaços em que não haja fontes atípicas de poluentes e sem fumadores. Existe uma tendência para se projectar sistemas AVAC insuflando o caudal mínimo de AN, para assim se poupar no consumo de energia. No entanto, em determinadas situações, com esse procedimento está-se a fazer precisamente o contrário. Nessas situações não se está a aproveitar a oportunidade de aumentar a QAI e, simultaneamente, reduzir o consumo de energia. Neste estudo calculou-se o consumo energético do sistema AVAC do edifício, inicialmente insuflando o caudal mínimo de AN, e depois repetiu-se o cálculo várias vezes aumentando esse mesmo caudal progressivamente. Este cálculo foi feito para dois tipos de sistemas de ar, CAV e VAV, e para três localizações diferentes do mesmo edifício. Foi também estudada a possibilidade do sistema funcionar em regime de “free cooling”, e também foram feitos cálculos para diferentes temperaturas de insuflação em situação de arrefecimento. Concluiu-se que, para as localizações do edifício em que este apresenta necessidades de arrefecimento anuais superiores às de aquecimento, o caudal de AN responsável pelo menor consumo energético do seu sistema AVAC é superior ao mínimo imposto pelo RSECE. Observou-se também que, quando se insufla no edifício o caudal mínimo de AN e o sistema está preparado para funcionar em regime de “free cooling”, conseguem-se poupanças no consumo energético anual do sistema bastante relevantes, independentemente do balanço entre as necessidades de aquecimento e arrefecimento anuais que o edifício apresenta. Em relação aos dois sistemas de ar estudados concluiu-se que, em qualquer das situações estudadas, o sistema VAV apresenta consumos energéticos inferiores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O sector dos edifícios é responsável por uma percentagem significativa dos consumos de energia primária e de energia eléctrica em Portugal, associada principalmente ao conforto térmico dos seus ocupantes. A União Europeia pretende uma redução de 20%, até 2020, dos consumos de energia e consequentes emissões de CO2 através da melhoria da eficiência energética dos edifícios públicos e residenciais. Em Portugal, o Plano Nacional para a Eficiência Energética (PNAEE) tem por objectivo obter uma poupança anual de energia de pelo menos 1% até ao ano de 2016, tomando como base a média de consumos de energia final, registados entre 2001 e 2005. Neste contexto, os edifícios anteriores a 1990 (primeira versão do RCCTE) podem apresentar um potencial significativo de melhoria da sua eficiência energética com base na sua reabilitação. Os edifícios “Gaioleiros” (1880 – 1930) constituindo uma parte importante do património histórico da cidade de Lisboa, para os quais a informação sobre o seu desempenho térmico é limitada, considerou-se pertinente efectuar um estudo destinado à sua caracterização experimental e numérica, face à especificidade do comportamento térmico das suas paredes caracterizadas pela elevada espessura. No presente trabalho, apresenta-se a metodologia e os resultados experimentais da medição da resistência térmica das paredes e da medição das necessidades térmicas de aquecimento da habitação. Estes resultados experimentais foram utilizados na validação do modelo de simulação térmica da habitação, que posteriormente serviu para avaliar as suas necessidades térmicas de aquecimento (Nic) e de arrefecimento (Nvc), identificar oportunidades de melhoria e avaliar o respectivo potencial de reabilitação. Neste trabalho, como contributos para uma reabilitação sustentável, apresentam-se avaliações de oportunidades de melhoria com base em estratégias de reforço do isolamento térmico. Dos resultados obtidos concluiu-se que melhorando o isolamento térmico das paredes e vãos envidraçados é possível baixar consideravelmente os consumos de energia associados à habitação, cumprindo assim as exigências estabelecidas no RCCTE ao nível dos requisitos de qualidade térmica da envolvente e consumos energéticos para edifícios novos e grandes reabilitações.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A compactação dos equipamentos de tecnologia de informação e os aumentos simultâneos no consumo de energia dos processadores levam a que seja assegurada a distribuição adequada de ar frio, a remoção do ar quente, a capacidade adequada de arrefecimento e uma diminuição do consumo de energia. Considerando-se a cogeração como uma alternativa energeticamente eficiente em relação a outros métodos de produção de energia, com este trabalho faz-se a análise à rentabilidade de uma eventual integração de um sistema de cogeração num centro informático.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Magma flow in dykes is still not well understood; some reported magnetic fabrics are contradictory and the potential effects of exsolution and metasomatism processes on the magnetic properties are issues open to debate. Therefore, a long dyke made of segments with different thickness, which record distinct degrees of metasomatism, the Messejana-Plasencia dyke (MPD), was studied. Oriented dolerite samples were collected along several cross-sections and characterized by means of microscopy and magnetic analyses. The results obtained show that the effects of metasomatism on rock mineralogy are important, and that the metasomatic processes can greatly influence anisotropy degree and mean susceptibility only when rocks are strongly affected by metasomatism. Petrography, scanning electron microscopy (SEM) and bulk magnetic analyses show a high-temperature oxidation-exsolution event, experienced by the very early Ti-spinels, during the early stages of magma cooling, which was mostly observed in central domains of the thick dyke segments. Exsolution reduced the grain size of the magnetic carrier (multidomain to single domain transformation), thus producing composite fabrics involving inverse fabrics. These are likely responsible for a significant number of the 'abnormal' fabrics, which make the interpretation of magma flow much more complex. By choosing to use only the 'normal' fabric for magma flow determination, we have reduced by 50 per cent the number of relevant sites. In these sites, the imbrication angle of the magnetic foliation relative to dyke wall strongly suggests flow with end-members indicating vertical-dominated flow (seven sites) and horizontal-dominated flow (three sites).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When a paleomagnetic pole is sought for in an igneous body, the host rocks should be subjected to a contact test to assure that the determined paleopole has the age of the intrusion. If the contact test is positive, it precludes the possibility that the measured magnetization is a later effect. Therefore, we investigated the variations of the remanent magnetization along cross-sections of rocks hosting the Foum Zguid dyke (southern Morocco) and the dyke itself. A positive contact test was obtained, but it is mainly related with Chemical/Crystalline Remanent Magnetization due to metasomatic processes in the host-rocks during magma intrusion and cooling, and not only with Thermo-Remanent Magnetization as ordinarily assumed in standard studies. Paleomagnetic data obtained within the dyke then reflect the Earth magnetic field during emplacement of this well-dated (196.9 +/- 1.8 Ma) intrusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a study of the magnetic properties of a group of basalt samples from the Saldanha Massif (Mid-Atlantic Ridge - MAR - 36degrees 33' 54" N, 33degrees 26' W), and we set out to interpret these properties in the tectono-magmatic framework of this sector of the MAR. Most samples have low magnetic anisotropy and magnetic minerals of single domain grain size, typical of rapid cooling. The thermomagnetic study mostly shows two different susceptibility peaks. The high temperature peak is related to mineralogical alteration due to heating. The low temperature peak shows a distinction between three different stages of low temperature oxidation: the presence of titanomagnetite, titanomagnetite and titanomaghemite, and exclusively of titanomaghemite. Based on established empirical relationships between Curie temperature and degree of oxidation, the latter is tentatively deduced for all samples. Finally, swath bathymetry and sidescan sonar data combined with dive observations show that the Saldanha Massif is located over an exposed section of upper mantle rocks interpreted to be the result of detachment tectonics. Basalt samples inside the detachment zone often have higher than expected oxidation rates; this effect can be explained by the higher permeability caused by the detachment fault activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Knowledge on forced magma injection and magma flow in dykes is crucial for the understanding of how magmas migrate through the crust to the Earth's surface. Because many questions still persist, we used the long, thick, and deep-seated Foum Zguid dyke (Morocco) to investigate dyke emplacement and internal flow by means of magnetic methods, structural analysis, petrography, and scanning electron microscopy. We also investigated how the host rocks accommodated the intrusion. Regarding internal flow: 1. Important variations of the rock magnetic properties and magnetic fabric occur with distance from dyke wall; 2. anisotropy of anhysteretic remanent magnetization reveals that anisotropy of magnetic susceptibility (AMS) results mainly from the superposition of subfabrics with distinct coercivities and that the imbrication between magnetic foliation and dyke plane is more reliable to deduce flow than the orientation of the AMS maximum principal axis; and 3. a dominant upward flow near the margins can be inferred. The magnetic fabric closest to the dyke wall likely records magma flow best due to fast cooling, whereas in the core the magnetic properties have been affected by high-temperature exsolution and metasomatic effects due to slow cooling. Regarding dyke emplacement, this study shows that the thick forceful intrusion induced deformation by homogeneous flattening and/or folding of the host sedimentary strata. Dewatering related to heat, as recorded by thick quartz veins bordering the dyke in some localities, may have also helped accommodating dyke intrusion. The spatial arrangement of quartz veins and their geometrical relationship with the dyke indicate a preintrusive to synintrusive sinistral component of strike slip.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A mat of electrospun cellulose fibers are deposed on transparent conductive oxide covered glass, and two such plates enclose a nematic liquid crystal. Thus two new types of Cellulose based Polymer Dispersed Liquid Crystal devices, based on hydroxypropylcellulose and Cellulose Acetate and the nematic liquid crystal E7 have been obtained. The current-voltage characteristics indicates ionic type conduction. Heating-cooling cycles have been applied on the samples and the activation energies have been determined. Simultaneously with the thermo-stimulated currents, the optical transmission dependence on the d.c. electric field and temperature was registered. ON-OFF switching times have been determined for different control voltages. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The optimal power flow problem has been widely studied in order to improve power systems operation and planning. For real power systems, the problem is formulated as a non-linear and as a large combinatorial problem. The first approaches used to solve this problem were based on mathematical methods which required huge computational efforts. Lately, artificial intelligence techniques, such as metaheuristics based on biological processes, were adopted. Metaheuristics require lower computational resources, which is a clear advantage for addressing the problem in large power systems. This paper proposes a methodology to solve optimal power flow on economic dispatch context using a Simulated Annealing algorithm inspired on the cooling temperature process seen in metallurgy. The main contribution of the proposed method is the specific neighborhood generation according to the optimal power flow problem characteristics. The proposed methodology has been tested with IEEE 6 bus and 30 bus networks. The obtained results are compared with other wellknown methodologies presented in the literature, showing the effectiveness of the proposed method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a distributed model predictive control (DMPC) for indoor thermal comfort that simultaneously optimizes the consumption of a limited shared energy resource. The control objective of each subsystem is to minimize the heating/cooling energy cost while maintaining the indoor temperature and used power inside bounds. In a distributed coordinated environment, the control uses multiple dynamically decoupled agents (one for each subsystem/house) aiming to achieve satisfaction of coupling constraints. According to the hourly power demand profile, each house assigns a priority level that indicates how much is willing to bid in auction for consume the limited clean resource. This procedure allows the bidding value vary hourly and consequently, the agents order to access to the clean energy also varies. Despite of power constraints, all houses have also thermal comfort constraints that must be fulfilled. The system is simulated with several houses in a distributed environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Engenharia Química

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de Doutoramento, Física, 17 de Dezembro de 2013, Universidade dos Açores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica com especialização em Energia, Climatização e Refrigeração

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Civil na Área de especialização em Edificações