952 resultados para Conventional hemodialysis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is growing interest in studies on sanitizers other than chlorine that can maintain the quality of organic products without affecting their phytochemical content. The effects of using chlorinated and ozonized water treatments, as sanitizing procedures, on the post-harvest quality of organic and conventional broccoli (Brassica oleracea L.) cv. Italica was evaluated. The biochemical parameters (chlorophyll, polyphenols, flavonoids, vitamin C and antioxidant capacity) of the broccoli samples were analyzed at day (C) (arrival of the plant from the field, original features), and 1, 4 and 7 days after harvest. The polyamine analysis was performed on arrival of the plant from the field and on the first and seventh days. The cultivation procedure influenced polyphenol, vitamin C and total chlorophyll content, and the highest value was observed in organic broccoli after the fourth day. Flavenoid content was higher in organic broccoli. The use of ozone appears not to have had an influence on the amount of polyphenolic, flavonoids and vitamin C during storage. Total chlorophyll content was less affected by ozonized water than by the chlorine treatment as at the first and fourth days of storage. The highest content of putrescine was found in conventional broccoli, while the highest levels of spermidine and spermine were found in organic broccoli. Antioxidant capacity was highest in organic broccoli after day 4 of storage and was affected by the bioactive compounds analyzed. Methods of cultivation influenced natural antioxidant and chlorophyll contents in broccoli under cold storage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to investigate the influence of Nd:YAG laser on the shear bond strength to enamel and dentin of total and self-etch adhesives when the laser was applied over the adhesives, before they were photopolymerized, in an attempt to create a new bonding layer by dentin-adhesive melting.Material and Methods: One-hundred twenty bovine incisors were ground to obtain flat surfaces. Specimens were divided into two substrate groups (n=60): substrate E (enamel) and substrate D (dentin). Each substrate group was subdivided into four groups (n=15), according to the surface treatment accomplished: X (Xeno III self-etching adhesive, control), XL (Xeno III + laser Nd:YAG irradiation at 140 mJ/10 Hz for 60 seconds + photopolymerization, experimental), S (acid etching + Single Bond conventional adhesive, Control), and SL (acid etching + Single Bond + laser Nd:YAG at 140 mJ/10 Hz for 60 seconds + photopolymerization, experimental). The bonding area was delimited with 3-mm-diameter adhesive tape for the bonding procedures. Cylinders of composite were fabricated on the bonding area using a Teflon matrix. The teeth were stored in water at 37 degrees C/48 h and submitted to shear testing at a crosshead speed of 0.5 mm/min in a universal testing machine. Results were analyzed with three-way analysis of variance (ANOVA; substrate, adhesive, and treatment) and Tukey tests (alpha=0.05). ANOVA revealed significant differences for the substrate, adhesive system, and type of treatment: lased or unlased (p<0.05). The mean shear bond strength values (MPa) for the enamel groups were X=20.2 +/- 5.61, XL=23.6 +/- 4.92, S=20.8 +/- 4.55, SL=22.1 +/- 5.14 and for the dentin groups were X=14.1 +/- 7.51, XL=22.2 +/- 6.45, S=11.2 +/- 5.77, SL=15.9 +/- 3.61. For dentin, Xeno III self-etch adhesive showed significantly higher shear bond strength compared with Single Bond total-etch adhesive; Nd:YAG laser irradiation showed significantly higher shear bond strength compared with control (unlased).Conclusion: Nd:YAG laser application prior to photopolymerization of adhesive systems significantly increased the bond strength to dentin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the 2-year clinical performance of class II restorations made with a composite resin with two different viscosities.Methods: 47 patients received two class II restorations (n = 94), one made with GrandioSO (conventional viscosity CV), and the other with GrandioSO Heavy Flow (flowable viscosity FV), subjecting both materials to the same clinical conditions. The self-etching adhesive Futurabond M was used for all restorations. The composites were inserted using the incremental technique. The restorations were evaluated using the modified USPHS criteria according to the periods: baseline, 6 months, 1 year and 2 years after restorative procedures.Results: After 24 months, 40 patients attended the recall and 78 restorations were evaluated. In all periods, no secondary caries was observed. After 6 months, there were slightly overall changes of scores for most parameters. After 24 months, the higher number of changes from score Alfa to Bravo was observed for marginal discolouration (32.5% CV and 39.5% FV) and colour match (15% CV and 31.6% FV), followed by proximal contact (25% CV and 23.7% FV) and marginal adaptation (20% CV and 21.1% FV). For wear, surface texture and postoperative sensitivity the changes were very small. Just two restorations were lost during the 24-month follow up. Less than 5% of all restorations showed postoperative sensitivity. Chi-square test showed no significant differences between the two materials for all parameters analysed.Conclusion: After 2 years of clinical service, no significant differences were observed between GrandioSO conventional and GrandioSO Heavy Flow for the parameters analysed. Both materials provided acceptable clinical behaviour in class II restorations. Clinical Significance: This study presents the possibility of using a flowable composite with high filler content, for performing class II restorations. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of poorly treated water during hemodialysis may lead to contamination with nontuberculous mycobacteria (NTM). This study aimed to isolate and identify NTM species in the water of a Brazilian hemodialysis center. We collected 210 samples of water from the hydric system of the unit (post-osmosis system, hemodialysis rooms, reuse system, and hemodialysis equipment) and from the municipal supply network; we isolated the NTM by a classic microbiological technique and identified them by the PCR restriction enzyme pattern of the hsp65 gene (PRA). Fifty-one (24.3 %) of the collected samples tested positive for NTM; both the municipal supply network (2 samples, 3.2 %) and the hydric system of the hemodialysis center (49 samples, 96.1 %) contained NTM. We isolated and identified potentially pathogenic bacteria such as Mycobacterium lentiflavum (59.0 %) and M. kansasii (5.0 %), as well as rarely pathogenic bacteria like M. gordonae (24.0 %), M. gastri (8.0 %), and M. szulgai (4.0 %). The ability of NTM to cause diseases is well documented in the literature. Therefore, the identification of NTM in the water of a Brazilian hemodialysis center calls for more effective water disinfection procedures in this unit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess the impact of replacing conventional mandibular complete dentures with implant-supported fixed complete dentures (ISFDs) on the oral health related quality of life (OHOOL) of edentulous patients and on the associated kinesiographic parameters. The patients had their complete dentures replaced by ISFDs and were assessed after 1, 2, 3, 6, and 12 months. An improvement of general OHQOL was observed 2 months after treatment with ISFDs. Kinesiographic recordings revealed significant mandibular vertical and horizontal opening increases and a greater vertical intrusion of the maxillary complete dentures during clenching after the treatment with ISFD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate the effects of elastic tubing training compared with conventional resistance training on the improvement of functional exercise capacity, muscle strength, fat-free mass, and systemic inflammation in patients with chronic obstructive pulmonary disease.Design: A prospective, randomized, eight-week clinical trial.Setting: The study was conducted in a university-based, outpatient, physical therapy clinic.Subjects: A total of 49 patients with moderate chronic obstructive pulmonary disease.Interventions: Participants were randomly assigned to perform elastic tubing training or conventional resistance training three times per week for eight weeks.Main measures: The primary outcome measure was functional exercise capacity. The secondary outcome measures were peripheral muscle strength, health-related quality of life assessed by the Chronic Respiratory Disease Questionnaire (CRDQ), fat-free mass, and cytokine profile.Results: After eight weeks, the mean distance covered during six minutes increased by 73 meters (69) in the elastic tubing group and by 42 meters (+/- 59) in the conventional group (p < 0.05). The muscle strength and quality of life improved in both groups (P < 0.05), with no significant differences between the groups. There was a trend toward an improved fat-free mass in both groups (P = 0.05). After the first and last sessions, there was an increase in interleukin 1 (IL-1) and interleukin 10 (IL-10) in both groups, while tumour necrosis factor alpha (TNF-) was stimulated only in the conventional training group.Conclusion: Elastic tubing training had a greater effect on functional exercise capacity than conventional resistance training. Both interventions were equally effective in improving muscle strength and quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the velocity of canine retraction, anchorage loss and changes on canine and first molar inclinations using self-ligating and conventional brackets.Materials and Methods: Twenty-five adults with Class I malocclusion and a treatment plan involving extractions of four first premolars were selected for this randomized split-mouth control trial. Patients had either conventional or self-ligating brackets bonded to maxillary canines randomly. Retraction was accomplished using 100-g nickel-titanium closed coil springs, which were reactivated every 4 weeks. Oblique radiographs were taken before and after canine retraction was completed, and the cephalograms were superimposed on stable structures of the maxilla. Cephalometric points were digitized twice by a blinded operator for error control, and the following landmarks were collected: canine cusp and apex horizontal changes, molar cusp and apex horizontal changes, and angulation changes in canines and molars. The blinded data, which were normally distributed, were analyzed through paired t-tests for group differences.Results: No differences were found between the two groups for all variables tested.Conclusions: Both brackets showed the same velocity of canine retraction and loss of anteroposterior anchorage of the molars. No changes were found between brackets regarding the inclination of canines and first molars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The imaging is essential to aid the diagnosis of horses that have performance decrease associated with any pain or clinical signs related to the vertebral column. Radiography is the first imaging examination performed in these cases, particularly for disorders affecting the cervical region. However, this technique has limitations when the study of subtle changes due to the overlapping of adjacent structures. Computed tomography is a new diagnostic method in Brazil for the study of bone disorders in horses, but it is of great diagnostic value associate with the radiographic examination in order to provide an accurate assessment of the study area, owing to superiority in image quality when compared to conventional radiography. The aim of this study is increase and update knowledge of diagnostic imaging available to investigate cervical disorders in horses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The understanding and quantification of the impact of tillage systems in their physical quality are fundamental in the development of sustainable agricultural systems. This study aimed to evaluate the quality of an Oxisol under conventional tillage (CT) and no-tillage system (NT), through different physical indicators. The management systems were: CT and NT for seven or eight consecutive years (medium textured soil) and CT and NT by nine and ten consecutive years (clay soil). Were determined, at the layers 0-0.10, 0.10-0.20; 0.20-0.30 m, soil resistance to penetration, total soil porosity, macroporosity and microporosity, soil water retention, S index, soil bulk density, maximum density and relative bulk density. Was observed great variation of soil resistance to penetration throughout the soybean and corn cycles, with its highest values were found in the surface layers. The NT showed greater resistance to penetration. Among the management systems, the results against indicators of soil physical quality were similar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)