998 resultados para Consumo de água - Optimização
Resumo:
Considering that alcohol has been identified, in the literature, as an evident risk factor for osteoporosis development, inducing loss of bone mass, the aim of this study was to evaluate the effect of the alcohol on the femur of male and female rats. For this purpose, 35 male and 35 female rats, divided into seven groups of five animals per genera were included. The groups were: control group that received food and water as much as they wished; alcohol group in the concentrations of 10, 20 and 30% and the isocalorie: groups corresponding to the concentration of alcohol. After 8 weeks, the animals were sacrificed and evaluated regarding to the body weight and nutritional conditions. Unilateral femurs were removed and analyzed in relation to the length, width, and thickness of the bone cortical, trabeculae percentage and optical density. Data obtained were analyzed by ANOVA (Tukey; p<0.05). Regarding to the weight, loss of weight was observed in the animals of the group alcohol 20% among females and 30% among the males. In relation to the nutritional conditions, the females with the dosages of 10, 20 and 30% of alcohol swallowed a mean of 25, 39 and 53% of Kcall and the males 22, 36 and 45 Kcal Jday coming from the alcohol. Alcohol reduced the length of the femur only in the group MG6. Mesio-distal width was higher in the group FG6 although the antero-posterior width was not modified. The cortical thickness among males and females was not altered however the percentage of trabeculae bone was reduced among females alcohol 30% and among males with the three alcoholic concentrations. Optical density was reduced in the concentration of 30% among the males and females. Under the experimental conditions, it could be concluded that the effect of alcohol was more evident among the males and in the trabeculae bone, and that the alcoholic concentration of 30% was the most harmful for the bone tissue, ....
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We conducted a study of the quality of water distributed by Artesian Well in relation to water supply served by the public for purposes of human consumption of UNESP Campus Guaratinguetá. Two sections of the network were randomly chosen and monitored for 105 days: the stretch of the pipeline started off the Water Treatment Station of the Autonomous Service of Water, Sewage and waste in the Municipality of Guaratinguetá and ended in a point consumption of the Child Family Center, while the section B began at the output of an artesian well and finished in a point of consumption of the Department of Civil Engineering. It is the deterioration of water quality in parts A and B, through comparative analysis of Bicarbonates, Total Hardness, Total Iron, free residual chlorine, pH, Total Residual, Turbidity, Conductivity, Color, Fecal Coliforms and Total Coliforms. Among the observations that can be highlighted: the Total Hardness was found in highest concentration in the extract; for Total Iron significant variations were obtained for both parts, and reduction of this parameter in two points of consumption analyzed, not the expected increase concentration, because the contact of water along the pipe, the CRL showed significant depletion to section A, which can be related to impurities in the water, the presence of biofilm on the walls of pipes, or because this is the stretch of greater extent to be covered by water for pH, this indicated that the water is alkaline and slightly acidic stretch in section B; Turbidity was found for the higher concentration to the passage, and a considerable reduction of this parameter at point consumption due to deposition of particulate matter along the stretch, the conductivity also showed a higher concentration in the extract, as well as an increase in this parameter at the point of consumption. Upon leaving ... (Complete abstract click electronic access below)
Resumo:
Frente ao desafio de prover água de melhor qualidade para o uso humano a um custo acessível e de simples execução, muitos métodos tem sido desenvolvidos e estudados. Uma metodologia que tem se destacado atualmente, é o método SODIS, sigla em inglês que significa, desinfecção da água por meio da luz solar. Essa metodologia tem como princípio a inativação de uma variada gama de microrganismos patogênicos a partir da ação dos raios solares. Essa metodologia consiste em submeter garrafas de água a um banho de luz solar por algumas horas. Para a realização do método SODIS pode-se utilizar garrafas PET (politereftalato de etileno), sendo que sua execução é simples e rápida além de possuir mínimos riscos envolvidos. A fim de comprovar a eficácia desse método, muitos estudos tem investigado os mecanismos e fatores importantes envolvidos no processo de inativação. Da compreensão desses mecanismos e fatores críticos, preconizou-se ações que visam garantir e maximizar a eficiência do método em variadas situações e condições climáticas sem que o método se torne complexo ou oneroso. O método SODIS se mostrou eficaz na inativação de várias espécies de fungos, vírus, bactérias e até protozoários. Estudos de campo revelaram a sua eficácia prática, ocasionando uma diminuição expressiva nas ocorrências referentes a quadros de diarréia e diarréia severa nas populações estudadas
Resumo:
O presente trabalho aborda os problemas relacionados com a escassez de água, os desafios para preservação, as perspectivas futuras e a conscientização da população. Mostra que grande parcela da população mundial já sofre com a falta de água potável, levando a conflitos pelos usos múltiplos da água. As diversas formas de poluição causam degradação dos rios, lagos e aquíferos prejudicando todas as formas de vida, desequilibrando todo o ecossistema. Novas tecnologias para agricultura, estratégias para aumentar as reservas de água potável tanto superficiais quanto subterrâneas e estratégias para o reaproveitamento de água são medidas encontradas para um consumo sustentável
Resumo:
The anaerobic treatment of sewage is widely employed in Brazil and it is an appreciated way for the treatment of effluents, helping to reduce the environmental impact in rivers. The methane gas obtained from the process can be applied to improve the energetic efficiency of the system, reducing the amount of waste and the cost of the treatment process. This work presents the net energy balance of anaerobic reactors applied to the treatment of sewage. The analysis was performed considering full-scale and laboratory-scale treatment systems. In laboratory scale, the results from three kinds of systems were compared regarding the biological treatment of greywater. Two of them (UASB7 and UASB12) were anaerobic and the other one was a combined anaerobic-aerobic system (UASB7/SBR6). Greywater methanization (compared to theoretical maximum) was calculated considering 100% removal (g BOD/day), the literature percentage removal and the anionic surfactant presence in the effluentt. For each of these three cases, the efficiencies were, respectively, 16.9%, 43.6% and 51.3% in UASB7 reactor, 25.6%, 50.3% and 59.2% in UASB12 reactor and 30.6%, 61.2% and 71.9% in UASB7/SBR6 reactor. The energetic potential was found to be 4.66x10-4, 7.77x10-4 and 5.12x10-4 kWh/L for the UASB7, UASB12 and UASB7/SBR6 reactors, respectively. The pumping system, the aeration (in the anaerobic-aerobic system) and the temperature controlled heating system were considered to calculate the energetic consumption. However, the third one was not employed since tropical regions like Brazil do not need heating systems and also because of its high energetic consumption. The calculated net energy balance in the reactors was negative in the case of greywater, respectively -0.16, -0.28 and -0.18 kWh/L for the reactors UASB7, UASB12 and UASB7/SRB6. In full scale (ETE Jardim das Flores - Rio Claro, SP), the average energy... (Complete abstract click electronic access below)
Resumo:
Nowadays, the biggest part of the world's energy supply comes from fossil fuels and nuclear. However, the current need of the society for the preservation of the environment and wise use of natural resources, has favored the search for alternative energy sources and improvement of energy efficiency. In this new scenario, companies are beginning to mobilize in order to adapt its facilities to renewable energy. Solar, with its immense potential, not really exploited yet, can be very useful for companies that want to beat their sustainability goals. Given these facts, the aim is to evaluate the economic viability of introducing a solar water heater which uses a colorless PET bottle as one of its components in a plant. The hot water generated will heat the air of a paint booth and a warm house, reducing energy consumption, since they are heated by electric heaters
Resumo:
The purpose of this project is to verify whether anaerobic reactors applied to sewage treatment are energetically self-sufficient. This evaluation can be made by balancing the methane produced through the anaerobic transformation stages (hydrolysis, acidogenesis, acetogenesis and methanogenesis) and the reactor energy consumption requirements. The original project included methanogenic activity tests, which could not be performed due to setbacks in the installation of an analytical instrument. Scientific articles about bench- and full-scale anaerobic reactors were investigated instead. An average substrate-to-methane conversion efficiency of 58,2±18,6% was found for the bench-scale reactors and higher efficiencies (89,2%) were found for the cases which had higher Organic Loading Rates (OLRs) values. The average energy output was 0,013 kWh/Lsewage, value unable to meet the energy needs for the reactor operation, considering equipments normally used such as temperature controller. This balance can become positive if few hypotheses are made, for example (i) to eliminate the use of temperature controller (ii) to alter the operation pattern from continuous to intermittent. Based on energy balance assessment of eight bench-scale reactors, it was observed that the implementation of a system for biogas utilization is not energetically feasible. However, interesting results were found for a full-scale sewage treatment plant, ETE Ouro Verde – Foz do Iguaçu, PR, Brazil. Even though its substrate-tomethane conversion efficiency was about 10% only, the energy balance was quite positive, with energy consumption of 68 kWh/month and energy production of 660 kWh/month. This analysis leads us to conclude that energy recovery from full-scale sewage treatment plants should be practiced by other plants
Resumo:
água que abastece uma cidade se não for tratada pode tornar-se importante veículo de transmissores de doenças. O controle da qualidade é uma medida que visa, principalmente, garantir a saúde da população. O objetivo desta pesquisa foi avaliar a qualidade da água distribuída pelo sistema de abastecimento da cidade de Santa Lúcia – SP. A água proveniente desse sistema chega até as residências e, muitas vezes, é consumida sem nenhum tratamento doméstico complementar. A cidade de Santa Lúcia é abastecida por três poços profundos (P2, P3, e P4). Com o intuito de avaliar a qualidade da água captada desses poços e distribuídas para consumo humano foram coletadas amostras diretamente dos poços e de um ponto de consumo nas áreas abastecidas por cada poço. Foram feitas três coletas em cada ponto, em três diferentes épocas do ano. Realizaram-se análises físico-químicas e bacteriológicas em todas as amostras. As análises bacteriológicas foram feitas para determinação da presença de coliformes totais, E. coli e contagem padrão de bactérias heterotróficas em placa. As análises físico-químicas avaliaram cloro residual livre, fluoreto, turbidez, pH, cor aparente e sólidos totais dissolvidos. Duas amostras foram positivas para coliformes totais, apenas uma amostra coletada no poço 2 foi positiva para E. coli. Para bactérias heterotróficas todas a amostras apresentaram contagem em placa inferior a 500 UFC/mL. Todas as amostras estavam dentro do padrão determinado pela legislação para pH, turbidez e sólidos totais dissolvidos. Todas as amostras coletadas no poço 2 tiveram como resultado ausência de cloro residual livre, o mesmo resultado para os demais pontos na segunda coleta de amostras. Todas as amostras apresentaram fluoreto com valores abaixo do VMP estabelecido pela legislação brasileira porém apenas cinco com concentrações dentro da faixa estabelecida pela legislação do Estado de São Paulo ...
Resumo:
The cassava wastewater, generated during the cassava processing, is a pollutant and toxic waste. This study compared the efficiency of the cassava wastewater treatment in three batch aerobic systems with a ru1nning time of 24 hours, and aeration stoppage of 12h with 2,500, 6,000 and 10,000 mg COD L-1 . The systems were evaluated for COD, pH, SVI and F/M. The results showed that the reactor with aeration stoppage for 12 hours, with 2,500 mg COD L-1 , presented the best reduction in a process with considerable energy consumption saving compared to traditional continuous systems.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Over the years, water has become an increasingly valuable resource and scarce, this situation is attributed to factors such as population growth, poor distribution and increasing degradation of water resources as a result of indiscriminate human activities in the middle environment, making their dwindling availability and increasing its cost. I n this context , the use of rainwater for non-potable purposes begins to be stimulated in Brazil , as a measure to preserve this resource , while in countries such as Japan and Germany , this technique has already been used for a long time. The ability to capture rainwater reduces the demand for sanitation companies, also resulting in cost reduction with the water bill and the risk of flooding in the event of heavy rains. The stored water is used only for non-potable purposes, such as toilets, taps into the garden, for washing vehicles and clothing. This work was developed with the aim of presenting the importance of rational use of water, associated with viability constructive economic and consumption of the installation of rain water harvesting, and for that, considered four case studies. From this study, it was found that the implementation of this system has led to a reduction in costs of water and sewer consumption poses no hazard to the user and its installation does not require significant changes in building construction, however, in relation to the economy, should be made a detailed analysis in each case for investment to bring a suitable financial return within the lifetime of the system
Resumo:
Pós-graduação em Ciência Animal - FMVA
Resumo:
Pós-graduação em Microbiologia Agropecuária - FCAV
Resumo:
Pós-graduação em Ciência Animal - FMVA