995 resultados para Collaborative Testing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. Collaborative quality improvement programs have been successfully used to manage chronic diseases in adults and acute lung complications in premature infants. Their effectiveness to improve pain management in acute care hospitals is currently unknown. The purpose of this study was to determine whether a collaborative quality improvement program implemented at hospital level could improve pain management and overall pain relief. Design.To assess the effectiveness of the program, we performed a before-after trial comparing patient's self-reported pain management and experience before and after program implementation. We included all adult patients hospitalized for more than 24 hours and discharged either to their home or to a nursing facility, between March 1, 2001 and March 31, 2001 (before program implementation) and between September 15, 2005 and October 15, 2005 (after program implementation). Setting.A teaching hospital of 2,096 beds in Geneva, Switzerland. Patients.All adult patients hospitalized for more than 24 hours and discharged between 1 to 31 March 2001 (before program) and 15 September to 15 October 2005 (after program implementation). Interventions.Implementation of a collaborative quality improvement program using multifaceted interventions (staff education, opinion leaders, patient education, audit, and feedback) to improve pain management at hospital level. Outcome Measures.Patient-reported pain experience, pain management, and overall hospital experience based on the Picker Patient Experience questionnaire, perceived health (SF-36 Health survey). Results.After implementation of the program only 2.3% of the patients reported having no pain relief during their hospital stay (vs 4.5% in 2001, P = 0.05). Among nonsurgical patients, improvements were observed for pain assessment (42.3% vs 27.9% of the patients had pain intensity measured with a visual analog scale, P = 0.012), pain management (staff did everything they could to help in 78.9% vs 67.9% of cases P = 0.003), and pain relief (70.4% vs 57.3% of patients reported full pain relief P = 0.008). In surgical patients, pain assessment also improved (53.7.3% vs 37.6%) as well as pain treatment. More patients received treatments to relieve pain regularly or intermittently after program implementation (95.1% vs 91.9% P = 0.046). Conclusion.Implementation of a collaborative quality improvement program at hospital level improved both pain management and pain relief in patients. Further studies are needed to determine the overall cost-effectiveness of such programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To determine 1) HIV testing practices in a 1400-bed university hospital where local HIV prevalence is 0.4% and 2) the effect on testing practices of national HIV testing guidelines, revised in March 2010, recommending Physician-Initiated Counselling and Testing (PICT). METHODS: Using 2 hospital databases, we determined the number of HIV tests performed by selected clinical services, and the number of patients tested as a percentage of the number seen per service ('testing rate'). To explore the effect of the revised national guidelines, we examined testing rates for two years pre- and two years post-PICT guideline publication. RESULTS: Combining the clinical services, 253,178 patients were seen and 9,183 tests were performed (of which 80 tested positive, 0.9%) in the four-year study period. The emergency department (ED) performed the second highest number of tests, but had the lowest testing rates (0.9-1.1%). Of inpatient services, neurology and psychiatry had higher testing rates than internal medicine (19.7% and 9.6% versus 8%, respectively). There was no significant increase in testing rates, either globally or in the majority of the clinical services examined, and no increase in new HIV diagnoses post-PICT recommendations. CONCLUSIONS: Using a simple two-database tool, we observe no global improvement in HIV testing rates in our hospital following new national guidelines but do identify services where testing practices merit improvement. This study may show the limit of PICT strategies based on physician risk assessment, compared to the opt-out approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of our study was to identify and document some key cognitive aptitudes used by ambulance people in emergency situations. Better knowing such aptitudes is necessary for a school of ambulance people in order to improve the selection and education of students. The idea was to better consider real work activity requirements and characteristics, and to develop and implement genuine educational content and selection tools. We followed the work activity of ambulance professionals involved in real emergency situations. Some interventions were filmed and post-analyzed. We completed and validated our analysis by means of interviews with ambulance personnel. We selected some video sequences and used them as a support for the interviews. We identified and documented many different key aptitudes like orientation and spatial sense, the capacity to perform complex cognitive tasks and delicate manipulations in the context of divided attention, as well as diverse aptitudes relevant in collaborative work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Platelet P2YI2 receptor inhibition with clopidogrel, prasugrel or ticagrelor plays a key role to prevent recurrent ischaemic events after percutaneous coronary intervention in acute coronary syndromes or elective settings. The degree of platelet inhibition depends on the antiplatelet medication used and is influenced by clinical and genetic factors. A concept of therapeutic window exists. On one side, efficient anti-aggregation is required in order to reduce cardio-vascular events. On the other side, an excessive platelet inhibition represents a risk of bleeding complications. This article describes the current knowledge about some platelet function tests and genetic tests and summarises their role in the clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integral abutment bridges are constructed without an expansion joint in the superstructure of the bridge; therefore, the bridge girders, deck, abutment diaphragms, and abutments are monolithically constructed. The abutment piles in an integral abutment bridge are vertically orientated, and they are embedded into the pile cap. When this type of a bridge experiences thermal expansion or contraction, horizontal displacements are induced at the top of the abutment piles. The flexibility of the abutment piles eliminates the need to provide an expansion joint at the inside face to the abutments: Integral abutment bridge construction has been used in Iowa and other states for many years. This research is evaluating the performance of integral abutment bridges by investigating thermally induced displacements, strains, and temperatures in two Iowa bridges. Each bridge has a skewed alignment, contains five prestressed concrete girders that support a 30-ft wide roadway for three spans, and involves a water crossing. The bridges will be monitored for about two years. For each bridge, an instrumentation package includes measurement devices and hardware and software support systems. The measurement devices are displacement transducers, strain gages, and thermocouples. The hardware and software systems include a data-logger; multiplexers; directline telephone service and computer terminal modem; direct-line electrical power; lap-top computer; and an assortment of computer programs for monitoring, transmitting, and management of the data. Instrumentation has been installed on a bridge located in Guthrie County, and similar instrumentation is currently being installed on a bridge located in Story County. Preliminary test results for the bridge located in Guthrie County have revealed that temperature changes of the bridge deck and girders induce both longitudinal and transverse displacements of the abutments and significant flexural strains in the abutment piles. For an average temperature range of 73° F for the superstructure concrete in the bridge located in Guthrie County, the change in the bridge length was about 1 118 in. and the maximum, strong-axis, flexural-strain range for one of the abutment piles was about 400 micro-strains, which corresponds to a stress range of about 11,600 psi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examine the power of different exact tests of differentiation for diploid populations. Since there is not necessarily random mating within populations, the appropriate hypothesis to construct exact tests is that of independent sampling of genotypes. There are two categories of tests, FST-estimator tests and goodness of fit tests. In this latter category, we distinguish "allelic statistics", which account for the nature of alleles within genotypes, from "genotypic statistics" that do not. We show that the power of FST-estimator tests and of allelic goodness of fit tests are similar when sampling is balanced, and higher than the power of genotypic goodness of fit tests. When sampling is unbalanced, the most powerful tests are shown to belong to the allelic goodness of fit group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Individuals who are unaware of their HIV infection constitute a fragile and a critical population both from a personal and from a community-based point of view: if the infection is diagnosed too late, the outcome can be complicated by AIDS-defining diseases, whose prognosis may remain unfavourable even after the initiation of a potent antiretroviral therapy. These patients contribute to the virus spreading into the community, owing to a high viral load. It is now necessary to recognise the limits of a risk behaviour and disease-driven HIV screening policy. Since 2006, the American guidelines recommend a routine HIV testing for all patients age 13 to 64 years unless they specifically refuse the test (opt-out). In Switzerland, the recommendations remain so far risk-centred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This main report provides a general discussion of the load testing, structural evaluation, and load rating procedures. Specific details for each bridge are provided in individual report sections. Additional supporting information on load testing, analyses, and load rating are also provided in the attached appendices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Gastric banding (GB) is one of the most popular bariatric procedures for morbid obesity. Apart from causing weight loss by alimentary restriction, it can interfere with functions of the esophagus and upper stomach. The aim of this study was to evaluate if the results of extensive preoperative upper GI testing were correlated with long-term outcome and complications after GB. METHODS: Using a prospectively maintained computerized database including all the patients undergoing bariatric operations in both our hospitals, we performed a retrospective analysis of the patients who underwent complete upper gastrointestinal (GI) testing (endoscopy, pH monitoring, and manometry) before GB. RESULTS: One hundred thirty-four patients underwent complete testing before GB. Abnormal pH monitoring (increased total reflux time, increased diurnal reflux time, increased number of reflux episodes) predicted the development of complications and especially pouch dilatation and food intolerance. The mean De Meester score was higher among patients who developed complications than in the remaining ones (25.4 vs 17.7, P=0.03). High lower esophageal sphincter pressure also predicted progressive long-term food intolerance. Endoscopic findings were not predictive of the long-term outcome. CONCLUSIONS: There is some association between the function of the upper digestive tract and long-term complications after gastric banding. Abnormal pH monitoring predicts overall long-term complications, especially food intolerance with or without reflux, and pouch dilatation, and a high lower esophageal sphincter pressure predicts long-term food intolerance. Extended upper gastrointestinal testing with endoscopy, 24-h pH monitoring, and esophageal manometry is probably worthwhile in selecting patients for gastric banding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to obtain organic compounds similar to the ones found in the organic matter of anthropogenic dark earth of Amazonia (ADE) using a chemical functionalization procedure on activated charcoal, as well as to determine their ecotoxicity. Based on the study of the organic matter from ADE, an organic model was proposed and an attempt to reproduce it was described. Activated charcoal was oxidized with the use of sodium hypochlorite at different concentrations. Nuclear magnetic resonance was performed to verify if the spectra of the obtained products were similar to the ones of humic acids from ADE. The similarity between spectra indicated that the obtained products were polycondensed aromatic structures with carboxyl groups: a soil amendment that can contribute to soil fertility and to its sustainable use. An ecotoxicological test with Daphnia similis was performed on the more soluble fraction (fulvic acids) of the produced soil amendment. Aryl chloride was formed during the synthesis of the organic compounds from activated charcoal functionalization and partially removed through a purification process. However, it is probable that some aryl chloride remained in the final product, since the ecotoxicological test indicated that the chemical functionalized soil amendment is moderately toxic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the use of our multimodal mixed reality telecommunication system to support remote acting rehearsal. The rehearsals involved two actors, located in London and Barcelona, and a director in another location in London. This triadic audiovisual telecommunication was performed in a spatial and multimodal collaborative mixed reality environment based on the 'destination-visitor' paradigm, which we define and put into use. We detail our heterogeneous system architecture, which spans the three distributed and technologically asymmetric sites, and features a range of capture, display, and transmission technologies. The actors' and director's experience of rehearsing a scene via the system are then discussed, exploring successes and failures of this heterogeneous form of telecollaboration. Overall, the common spatial frame of reference presented by the system to all parties was highly conducive to theatrical acting and directing, allowing blocking, gross gesture, and unambiguous instruction to be issued. The relative inexpressivity of the actors' embodiments was identified as the central limitation of the telecommunication, meaning that moments relying on performing and reacting to consequential facial expression and subtle gesture were less successful.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peer-reviewed