941 resultados para Cochlear Implant


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. The aim of the present study was to evaluate if a smaller morse taper abutment has a negative effect on the fracture resistance of implant-abutment connections under oblique compressive loads compared to a conventional abutment MATERIALS AND METHODS. Twenty morse taper conventional abutments (4.8 mm diameter) and smaller abutments (3.8 mm diameter) were tightened (20 Ncm) to their respective implants (3.5 x 11 mm) and after a 10 minute interval, implant/abutment assemblies were subjected to static compressive test, performed in a universal test machine with 1 mm/min displacement, at 45 degrees inclination. The maximum deformation force was determined. Data were statistically analyzed by student t test. RESULTS. Maximum deformation force of 4.8 mm and 3.8 mm abutments was approximately 95.33 kgf and 95.25 kgf, respectively, but no fractures were noted after mechanical test. Statistical analysis demonstrated that the evaluated abutments were statistically similar (P=.230). CONCLUSION. Abutment measuring 3.8 mm in diameter (reduced) presented mechanical properties similar to 4.8 mm (conventional) abutments, enabling its clinical use as indicated. [J Adv Prosthodont 2012;4:158-61]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the masticatory efficiency of patients rehabilitated with conventional dentures (CDs) or implant-retained mandibular overdentures. Background: Despite the evident benefits of implants on mastication as assessed by subjective patient-based outcomes, the extent of implant overdenture treatment effect on food comminution is not well established. Materials and methods: A randomised clinical trial was carried out with 29 completely edentulous patients divided into two groups. The first group was rehabilitated with a mandibular overdenture retained by two splinted implants with bar-clip system, while the second group was rehabilitated with a mandibular CD. Both groups also were rehabilitated with maxillary CDs. Masticatory efficiency and patient satisfaction were assessed 3 months after denture insertion. Masticatory efficiency was evaluated through the colorimetric method with the beads as the artificial test-food. Comparisons for masticatory efficiency and patient satisfaction were performed using Student's t-test (alpha = 0.05). Results: No significant statistical difference was found for masticatory efficiency (p = 0.198). Patient overall satisfaction was significantly higher for the mandibular overdenture (p < 0.001). In addition, mandibular overdenture patients were significantly more satisfied with chewing experience (p < 0.05) and retention of the lower denture (p < 0.005). Conclusion: The results of this study suggest that mandibular overdenture significantly improves chewing experience, although limited effect on masticatory efficiency has been observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The puerperium is the period of highest risk for thrombosis during a woman's reproductive life and it is an important time for initiating an effective contraceptive method in order to increase intergestational interval. Thus, the objective of the present study was to evaluated the effects of the etonogestrel (ENG)-releasing contraceptive implant inserted immediately postpartum on maternal hemostasis markers during the first six weeks of delivery. Materials and Methods: Forty healthy women aged 18 to 35 years-old were randomized to receive either the ENG-releasing implant 24-48 h after delivery (implant group; n=20) or nothing (control group) until the sixth postpartum week. Blood samples were collected at 24-48 h and at 6 weeks after delivery, and hemostatic variables, including fibrinogen, coagulation factors, protein C, free protein S, antithrombin, alpha 2-antiplasmin, plasminogen activator inhibitor 1, thrombin-antithrombin complex (TAT), prothrombin fragment (PF)1+2, and D-dimers, as well as normalized activated protein C sensitivity ratio (nAPCsr), thrombin time, activated partial thromboplastin time, and prothrombin time were evaluated. Results: Insertion of the ENG-releasing contraceptive implant did not change the physiological reduction in overall coagulation (TAT and PF1+2) and fibrinolysis (D-dimer) markers, or nAPCsr. Reductions in factors II, VII, X and fibrinogen and increases in factor V were greater in the control than in the implant group. Clotting factors remained within normal limits throughout the study. Conclusion: The ENG-releasing contraceptive implant inserted immediately postpartum did not have negative effects on physiological variations of the hemostatic system during the first 6 weeks postpartum. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS. Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The frameworks were cast as one-piece (Group A) and later transversally sectioned through a diagonal axis (Group B) and compared to frameworks that were cast diagonally separated (Group C). All separated frameworks were laser welded. Only one side of the frameworks was screwed. RESULTS. The results on the tightened side were significantly lower in Group C (6.43 +/- 3.24 mu m) when compared to Groups A (16.50 +/- 7.55 mu m) and B (16.27 +/- 1.71 mu m) (P<.05). On the opposite side, the diagonal section of the one-piece castings for laser welding showed significant improvement in the levels of misfit of the frameworks (Group A, 58.66 +/- 14.30 mu m; Group B, 39.4.8 +/- 12.03 mu m; Group C, 23.13 +/- 8.24 mu m) (P<.05). CONCLUSION. Casting diagonally sectioned frameworks lowers the misfit levels. Lower misfit levels for the frameworks can be achieved by diagonally sectioning one-piece frameworks. [J Adv Prosthodont 2012;4:89-92]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two cases of swallowing of foreign material related to dental implants during dental practice are described. A conservative approach by clinical-radiographic follow-up was performed in both cases; however, one of the patients required colonoscopy under general anesthesia for the removal of the impacted foreign body from the intestinal region. These complications not only have associated economic cost but also carry the risk of malpractice litigation against the professional; thus, the surgeon was responsible for all the costs of hospital and surgery management of this case. Details of the clinical signs, radiographic examinations, type of treatment, and follow-up are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the role of transitory latex and sylastic (R) implants in tympanoplasty on the closure of tympanic perforations. METHODS: A randomized double-blind prospective study was conducted on 107 patients with chronic otitis media submitted to underlay tympanoplasty and divided at random into three groups: control with no transitory implant, latex membrane group, and sylastic (R) membrane group. RESULTS: Greater graft vascularization occurred in the latex membrane group (p<0.05). Good biocompatibility was obtained with the use of the latex and silicone implants, with no effect on the occurrence of infection, otorrhea or otorragy. CONCLUSION: The use of a transitory latex implant induced greater graft vascularization, with a biocompatible interaction with the tissue of the human tympanic membrane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mini-implant insertion requires accurate surgical technique. This study shows an insertion technique using only tooth crown references; its scientific basis is evaluated radiographically. The sample consisted of 213 inter-radicular septa, evaluated in 53 bitewing radiographs. The proximal contour of adjacent tooth crowns was used to define septum width. The midpoint of the septum width was linked to the interdental contact point to determine septum midline. The distances from septum midline to "mesial and distal teeth were measured to evaluate the septum midline centralization degree in two different septum heights. The difference between mesial and distal distances represented the septum midline deviation degree. The mesial and distal distances were compared by t-tests, and the septum midline deviation was correlated with septum height using Pearson's correlation test. The mesial and distal distances were not statistically different in the midpoint of the septum height, but they were different at the apical septum height. There was a moderate correlation (r = 0.45) between septum midline deviation and septum height. The tooth crown references evaluated on interproximal radiographs determine a high centralization degree of the septum midline on which the insertion site could be defined. The greater centralization degree was observed at the coronal septum area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cochlear implants are the best treatment for congenital profound deafness. Pediatric candidates to implantation are seen as vulnerable citizens, and the decision of implanting cochlear devices is ultimately in the hands of their parents/guardians. The Brazilian Penal Code dictates that deaf people may enjoy diminished criminal capacity. Many are the bioethical controversies around cochlear implants, as representatives from the deaf community have seen in them a means of decimating their culture and intrinsic values. Objective: This paper aims to discuss, in bioethical terms, the validity of implanting cochlear hearing aids in children by analyzing their vulnerability and the social/cultural implications of the procedure itself, aside from looking into the medical/legal aspects connected to their criminal capacity. Materials and Methods: The topic was searched on databases Medline and Lilacs; ethical analysis was done based on principialist bioethics. Results: Cochlear implants are the best therapeutic option for people with profound deafness and are morally justified. The level of criminal capacity attributed to deaf people requires careful analysis of the subject's degree of understanding and determination when carrying out the acts for which he/she has been charged. Conclusion: Cochlear implants are morally valid. Implantations must be analyzed on an each case basis. ENT physicians bear the ethical responsibility for indicating cochlear implants and must properly inform the child's parents/guardians and get their written consent before performing the procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the role of keratinized mucosa around dental implants, correlating with other clinical parameters related to the success of dental implants. Design: Cross-section. Setting: Institutional tertiary referral hospital. Patients: A total of 202 dental implants fixed in the cleft area of 109 patients with cleft lip and/or palate were evaluated. Interventions: The evaluated clinical parameters were probing depth and gingival and plaque indexes on the buccal surface (three sites). Main Outcome Measures: All clinical parameters were correlated with the width of keratinized mucosa around the implants. Results: The largest probing depths were detected when the width of keratinized mucosa was 2 mm or more, with a statistically significant difference between the means of the probing depth and keratinized mucosa width. Conclusion: Even though the present results suggest that peri-implant health can be observed in areas with keratinized mucosa width under 2 mm provided an adequate oral hygiene control is performed, longitudinal randomized studies are necessary to analyze the relationship between the width of keratinized mucosa and the health of peri-implant tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetives: Determine the stability of tibial and femoral components of 20 cementless knee arthroplasties with rotating platform. Methods: The 20 patients (20 knees) underwent an analysis of dynamic radiographs with an image amplifier and maneuvers of varus and valgus which were compared to static frontal and lateral radiographs of the knees and analyzed by two experienced surgeons in a double-blind way. Results: We could observe in this study that both methods showed very similar results for the stability of the tibial and femoral components (p<0.001) using the Kappa method for comparison. Conclusion: The tibial component was more unstable in relation to the femoral component in both static and dynamic studies. Level of Evidence IV, Case Series.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In sites with diminished bone volume, the osseointegration of dental implants can be compromised. Innovative biomaterials have been developed to aid successful osseointegration outcomes. Purpose: The aim of this study was to evaluate the osteogenic potential of angiogenic latex proteins for improved bone formation and osseointegration of dental implants. Materials and Methods: Ten dogs were submitted to bilateral circumferential defects (5.0 x 6.3 mm) in the mandible. Dental implant (3.3 x 10.0 mm, TiUnite MK3 (TM), Nobel Biocare AB, Goteborg, Sweden) was installed in the center of the defects. The gap was filled either with coagulum (Cg), autogenous bone graft (BG), or latex angiogenic proteins pool (LPP). Five animals were sacrificed after 4 weeks and 12 weeks, respectively. Implant stability was evaluated using resonance frequency analysis (Osstell Mentor T, Osstell AB, Goteborg, Sweden), and bone formation was analyzed by histological and histometric analysis. Results: LPP showed bone regeneration similar to BG and Cg at 4 weeks and 12 weeks, respectively (p >= 3.05). Bone formation, osseointegration, and implant stability improved significantly from 4 to 12 weeks (p <= 2.05). Conclusion: Based on methodological limitations of this study, Cg alone delivers higher bone formation in the defect as compared with BG at 12 weeks; compared with Cg and BG, the treatment with LPP exhibits no advantage in terms of osteogenic potential in this experimental model, although overall osseointegration was not affected by the treatments employed in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been a matter of debate as to whether dental implant therapies are suitable for patients subjected to long-term use of bisphosphonates (BPs). This report presents a case of a 76-year-old woman who developed BPs-related osteonecrosis of the jaw (BRONJ) in the left hemimandible after dental implant exposure. The implants and the necrotic crestal bone were removed, and postoperatively, a delay in tissue healing with bone exposure was noticed. The histologic analysis of the block biopsies revealed a lamellar bone tissue exhibiting necrotic areas and bacterial colonies associated with the bone outer surface. The bone-implant interface showed viable lamellar bone with enlarged vascular spaces in the areas between the implant threads. The possible mechanisms for the loss of implants in BRONJ patients are discussed, and the potential protocols for dental implant rehabilitation for patients under BP therapies are presented. (Implant Dent 2012;21:449-453)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Primary and secondary stabilities of immediately loaded mandibular implants restored with fixed prostheses (FP) using rigid or semirigid splinting systems were clinically and radiographically evaluated. Methods: Fifteen edentulous patients were rehabilitated using hybrid FP; each had 5 implants placed between the mental foramens. Two groups were randomly divided: group 1-FP with the conventional rigid bar splinting the implants and group 2-semi-rigid cantilever extension system with titanium bars placed in the 2 distal abutment cylinders. Primary stability was evaluated using resonance frequency analysis after installation of the implant abutments. The measurements were made at 3 times: T0, at baseline; T1, 4 months after implant placement; and T2, 8 months after implant placement. Presence of mobility and inflammation in the implant surrounding regions were checked. Stability data were submitted to statistical analysis for comparison between groups (P, 0.05). Results: Implant survival rate for the implants was of 100% in both groups. No significant differences in the mean implant stability quotient values were found for both groups from baseline and after the 8-month follow-up. Conclusion: The immediate loading of the implants was satisfactory, and both splinting conditions (rigid and semi-rigid) can be successfully used for the restoration of edentulous mandibles. (Implant Dent 2012;21:486-490)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Because the mechanical behavior of the implant-abutment system is critical for the longevity of implant-supported reconstructions, this study evaluated the fatigue reliability of different implant-abutment systems used as single-unit crowns and their failure modes. Methods and Materials: Sixty-three Ti-6Al-4V implants were divided in 3 groups: Replace Select (RS); IC-IMP Osseotite; and Unitite were restored with their respective abutments. Anatomically correct central incisor metal crowns were cemented and subjected to separate single load to failure tests and step-stress accelerated life testing (n = 18). A master Weibull curve and reliability for a mission of 50,000 cycles at 200 N were calculated. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The load at failure mean values during step-stress accelerated life testing were 348.14 N for RS, 324.07 N for Osseotite, and 321.29 N for the Unitite systems. No differences in reliability levels were detected between systems, and only the RS system mechanical failures were shown to be accelerated by damage accumulation. Failure modes differed between systems. Conclusions: The 3 evaluated systems did not present significantly different reliability; however, failure modes were different. (Implant Dent 2012;21:67-71)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In recent years, the benefits associated with the use of cochlear implants (CIs), especially with regard to speech perception, have proven to surpass those produced by the use of hearing aids, making CIs a highly efficient resource for patients with severe/profound hearing loss. However, few studies so far have assessed the satisfaction of adult users of CIs. Objective: To analyze the relationship between the level of speech perception and degree of satisfaction of adult users of CI. Method: This was a prospective cross-sectional study conducted in the Audiological Research Center (CPA) of the Hospital of Craniofacial Anomalies, University of São Paulo (HRAC/USP), in Bauru, São Paulo, Brazil. A total of 12 users of CIs with pre-lingual or post-lingual hearing loss participated in this study. The following tools were used in the assessment: a questionnaire, "Satisfaction with Amplification in Daily Life" (SADL), culturally adapted to Brazilian Portuguese, as well as its relationship with the speech perception results; a speech perception test under quiet conditions; and the Hearing in Noise Test (HINT)Brazil under free field conditions. Results: The participants in the study were on the whole satisfied with their devices, and the degree of satisfaction correlated positively with the ability to perceive monosyllabic words under quiet conditions. The satisfaction did not correlate with the level of speech perception in noisy environments. Conclusion: Assessments of satisfaction may help professionals to predict what other factors, in addition to speech perception, may contribute to the satisfaction of CI users in order to reorganize the intervention process to improve the users' quality of life.