932 resultados para Classical logic
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: The effects of chronic music auditory stimulation on the cardiovascular system have been investigated in the literature. However, data regarding the acute effects of different styles of music on cardiac autonomic regulation are lacking. The literature has indicated that auditory stimulation with white noise above 50 dB induces cardiac responses. We aimed to evaluate the acute effects of classical baroque and heavy metal music of different intensities on cardiac autonomic regulation. Study design: The study was performed in 16 healthy men aged 18-25 years. All procedures were performed in the same soundproof room. We analyzed heart rate variability (HRV) in time (standard deviation of normal-to-normal R-R intervals [SDNN], root-mean square of differences [RMSSD] and percentage of adjacent NN intervals with a difference of duration greater than 50 ms [pNN50]) and frequency (low frequency [LF], high frequency [HF] and LF/HF ratio) domains. HRV was recorded at rest for 10 minutes. Subsequently, the volunteers were exposed to one of the two musical styles (classical baroque or heavy metal music) for five minutes through an earphone, followed by a five-minute period of rest, and then they were exposed to the other style for another five minutes. The subjects were exposed to three equivalent sound levels (60- 70dB, 70-80dB and 80-90dB). The sequence of songs was randomized for each individual. Results: Auditory stimulation with heavy metal music did not influence HRV indices in the time and frequency domains in the three equivalent sound level ranges. The same was observed with classical baroque musical auditory stimulation with the three equivalent sound level ranges. Conclusion: Musical auditory stimulation of different intensities did not influence cardiac autonomic regulation in men.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This paper reports a research to evaluate the potential and the effects of use of annotated Paraconsistent logic in automatic indexing. This logic attempts to deal with contradictions, concerned with studying and developing inconsistency-tolerant systems of logic. This logic, being flexible and containing logical states that go beyond the dichotomies yes and no, permits to advance the hypothesis that the results of indexing could be better than those obtained by traditional methods. Interactions between different disciplines, as information retrieval, automatic indexing, information visualization, and nonclassical logics were considered in this research. From the methodological point of view, an algorithm for treatment of uncertainty and imprecision, developed under the Paraconsistent logic, was used to modify the values of the weights assigned to indexing terms of the text collections. The tests were performed on an information visualization system named Projection Explorer (PEx), created at Institute of Mathematics and Computer Science (ICMC - USP Sao Carlos), with available source code. PEx uses traditional vector space model to represent documents of a collection. The results were evaluated by criteria built in the information visualization system itself, and demonstrated measurable gains in the quality of the displays, confirming the hypothesis that the use of the para-analyser under the conditions of the experiment has the ability to generate more effective clusters of similar documents. This is a point that draws attention, since the constitution of more significant clusters can be used to enhance information indexing and retrieval. It can be argued that the adoption of non-dichotomous (non-exclusive) parameters provides new possibilities to relate similar information.
Resumo:
In our experiments, we studied the classical dynamic of a particle in vertical motion subject to a constant gravitational field and the partial shock with an elastic wall with oscillatory motion located below the particle. The motion of the particle was confined to the vertical direction by a glass guide tube, which was initially evacuated, allowing viscous drag forces to be disregarded. The time between impacts, as well as the time between the reference phase of the movement of the base and the moment of impact and the period of oscillation of the base will be acquired by a hardware and software to obtain the phases space to be compared later with the description of the system through mapping discrete variables via the 'particle velocity immediately after shock 'and' phase of the movement of the base at the instant of shock 'obtained by computer simulation. This requires developing an electronic analog system followed by Digital implemented in reconfigurable logic, more specifically a sequential machine able to discriminate the impact with the metal base from the impacts of the glass guide tube, based on the frequency spectrum of the response of the microphone to these different impacts
Resumo:
The objective of this study was to compare different resins and determine their matching color with Vita shade, also investigating the possibility of substitution among them and the correlation between the visual and spectrophotometry methods of color selection. The composite resin Tetric N-Ceram® shade A1 was used as light-control and color A4 as dark-control. For each material were prepared five 10 x 2 mm disks. Analyses were performed in a metamerism box by volunteers who ordered the specimens from the lightest to the darkest. The spectrophotometry was carried out using the spectrophotometer Vita Easyshade®. ∆E values were subjected to analysis of variance with 5% significance level. The Fisher exact test showed that there was no color match among the materials and the reference Vita shade. The possibility of substitution among the composites could not be established. The two methods are able to correctly differentiate the control resin A4 as distinct from the other resins shade A2.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Automatic method to classify images based on multiscale fractal descriptors and paraconsistent logic
Resumo:
In this study is presented an automatic method to classify images from fractal descriptors as decision rules, such as multiscale fractal dimension and lacunarity. The proposed methodology was divided in three steps: quantification of the regions of interest with fractal dimension and lacunarity, techniques under a multiscale approach; definition of reference patterns, which are the limits of each studied group; and, classification of each group, considering the combination of the reference patterns with signals maximization (an approach commonly considered in paraconsistent logic). The proposed method was used to classify histological prostatic images, aiming the diagnostic of prostate cancer. The accuracy levels were important, overcoming those obtained with Support Vector Machine (SVM) and Bestfirst Decicion Tree (BFTree) classifiers. The proposed approach allows recognize and classify patterns, offering the advantage of giving comprehensive results to the specialists.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We construct higher-spin N = 1 superalgebras as extensions of the super-Virasoro algebra containing generators for all spins s ≥ 3/2. We find two distinct classical (Poisson) algebras on the phase superspace. Our results indicate that only one of them can be consistently quantized.
Resumo:
Considering that downregulation of HLA expression could represent a potential mechanism for breast carcinogenesis and metastasis, the aim of the present study was to use immunohistochemical methods to analyze the expression of HLA-Ia, HLA-DR, HLA-DQ, HLA-E, and HLA-G in invasive ductal carcinoma (IDC) of the breast and to relate this HLA profile to anatomopathological parameters. Fifty-two IDC from breast biopsies were stratified according to histological differentiation (well, moderately, and poorly differentiated) and to the presence of metastases in axillary lymph nodes. The expression of HLA molecules was assessed by immunohistochemistry, using a computer-assisted system. Overall, 31 (59.6%) out of the 52 IDC breast biopsies exhibited high expression of HLA-G, but only 14 (26.9%) showed high expression of HLA-E. A large number (41, 78.8%) of the biopsies showed low expression of HLA-Ia, while 45 (86.5%) showed high expression of HLA-DQ and 36 (69.2%) underexpressed HLA-DR. Moreover, 24 (41.2%) of 52 biopsies had both low HLA-Ia expression and high HLA-G expression, while 11 (21.2%) had low HLA-Ia expression and high HLA-E expression. These results suggest that, by different mechanisms, the downregulation of HLA-Ia, HLA-E, and HLA-DR and the upregulation of HLA-G and HLA-DQ are associated with immune response evasion and breast cancer aggressiveness.