952 resultados para Chromatography liquid with fluorescence detection
Resumo:
DNA block copolymer, a new class of hybrid material composed of a synthetic polymer and an oligodeoxynucleotide segment, owns unique properties which can not be achieved by only one of the two polymers. Among amphiphilic DNA block copolymers, DNA-b-polypropylene oxide (PPO) was chosen as a model system, because PPO is biocompatible and has a Tg < 0 °C. Both properties might be essential for future applications in living systems. During my PhD study, I focused on the properties and the structures of DNA-b-PPO molecules. First, DNA-b-PPO micelles were studied by scanning force microscopy (SFM) and fluorescence correlation spectroscopy (FCS). In order to control the size of micelles without re-synthesis, micelles were incubated with template-independent DNA polymerase TdT and deoxynucleotide triphosphates in reaction buffer solution. By carrying out ex-situ experiments, the growth of micelles was visualized by imaging in liquid with AFM. Complementary measurements with FCS and polyacrylamide gel electrophoresis (PAGE) confirmed the increase in size. Furthermore, the growing process was studied with AFM in-situ at 37 °C. Hereby the growth of individual micelles could be observed. In contrast to ex-situ reactions, the growth of micelles adsorbed on mica surface for in-situ experiments terminated about one hour after the reaction was initiated. Two reasons were identified for the termination: (i) block of catalytic sites by interaction with the substrate and (ii) reduced exchange of molecules between micelles and the liquid environment. In addition, a geometrical model for AFM imaging was developed which allowed deriving the average number of mononucleotides added to DNA-b-PPO molecules in dependence on the enzymatic reaction time (chapter 3). Second, a prototype of a macroscopic DNA machine made of DNA-b-PPO was investigated. As DNA-b-PPO molecules were amphiphilic, they could form a monolayer at the air-water interface. Using a Langmuir film balance, the energy released owing to DNA hybridization was converted into macroscopic movements of the barriers in the Langmuir trough. A specially adapted Langmuir trough was build to exchange the subphase without changing the water level significantly. Upon exchanging the subphase with complementary DNA containing buffer solution, an increase of lateral pressure was observed which could be attributed to hybridization of single stranded DNA-b-PPO. The pressure versus area/molecule isotherms were recorded before and after hybridization. I also carried out a series of control experiments, in order to identify the best conditions of realizing a DNA machine with DNA-b-PPO. To relate the lateral pressure with molecular structures, Langmuir Blodgett (LB) films were transferred to highly ordered pyrolytic graphite (HOPG) and mica substrates at different pressures. These films were then investigated with AFM (chapter 4). At last, this thesis includes studies of DNA and DNA block copolymer assemblies with AFM, which were performed in cooperation with different group of the Sonderforschungsbereich 625 “From Single Molecules to Nanoscopically Structured Materials”. AFM was proven to be an important method to confirm the formation of multiblock copolymers and DNA networks (chapter 5).
Resumo:
Die vorliegende Dissertation entstand im Rahmen eines multizentrischen EU-geförderten Projektes, das die Anwendungsmöglichkeiten von Einzelnukleotid-Polymorphismen (SNPs) zur Individualisierung von Personen im Kontext der Zuordnung von biologischen Tatortspuren oder auch bei der Identifizierung unbekannter Toter behandelt. Die übergeordnete Zielsetzung des Projektes bestand darin, hochauflösende Genotypisierungsmethoden zu etablieren und zu validieren, die mit hoher Genauigkeit aber geringen Aufwand SNPs im Multiplexformat simultan analysieren können. Zunächst wurden 29 Y-chromosomale und 52 autosomale SNPs unter der Anforderung ausgewählt, dass sie als Multiplex eine möglichst hohe Individualisierungschance aufweisen. Anschließend folgten die Validierungen beider Multiplex-Systeme und der SNaPshot™-Minisequenzierungsmethode in systematischen Studien unter Beteiligung aller Arbeitsgruppen des Projektes. Die validierte Referenzmethode auf der Basis einer Minisequenzierung diente einerseits für die kontrollierte Zusammenarbeit unterschiedlicher Laboratorien und andererseits als Grundlage für die Entwicklung eines Assays zur SNP-Genotypisierung mittels der elektronischen Microarray-Technologie in dieser Arbeit. Der eigenständige Hauptteil dieser Dissertation beschreibt unter Verwendung der zuvor validierten autosomalen SNPs die Neuentwicklung und Validierung eines Hybridisierungsassays für die elektronische Microarray-Plattform der Firma Nanogen Dazu wurden im Vorfeld drei verschiedene Assays etabliert, die sich im Funktionsprinzip auf dem Microarray unterscheiden. Davon wurde leistungsorientiert das Capture down-Assay zur Weiterentwicklung ausgewählt. Nach zahlreichen Optimierungsmaßnahmen hinsichtlich PCR-Produktbehandlung, gerätespezifischer Abläufe und analysespezifischer Oligonukleotiddesigns stand das Capture down-Assay zur simultanen Typisierung von drei Individuen mit je 32 SNPs auf einem Microarray bereit. Anschließend wurde dieses Verfahren anhand von 40 DNA-Proben mit bekannten Genotypen für die 32 SNPs validiert und durch parallele SNaPshot™-Typisierung die Genauigkeit bestimmt. Das Ergebnis beweist nicht nur die Eignung des validierten Analyseassays und der elektronischen Microarray-Technologie für bestimmte Fragestellungen, sondern zeigt auch deren Vorteile in Bezug auf Schnelligkeit, Flexibilität und Effizienz. Die Automatisierung, welche die räumliche Anordnung der zu untersuchenden Fragmente unmittelbar vor der Analyse ermöglicht, reduziert unnötige Arbeitsschritte und damit die Fehlerhäufigkeit und Kontaminationsgefahr bei verbesserter Zeiteffizienz. Mit einer maximal erreichten Genauigkeit von 94% kann die Zuverlässigkeit der in der forensischen Genetik aktuell eingesetzten STR-Systeme jedoch noch nicht erreicht werden. Die Rolle des neuen Verfahrens wird damit nicht in einer Ablösung der etablierten Methoden, sondern in einer Ergänzung zur Lösung spezieller Probleme wie z.B. der Untersuchung stark degradierter DNA-Spuren zu finden sein.
Resumo:
Dextran-based polymers are versatile hydrophilic materials, which can provide functionalized surfaces in various areas including biological and medical applications. Functional, responsive, dextran based hydrogels are crosslinked, dextran based polymers allowing the modulation of response towards external stimuli. The controlled modulation of hydrogel properties towards specific applications and the detailed characterization of the optical, mechanical, and chemical properties are of strong interest in science and further applications. Especially, the structural characteristics of swollen hydrogel matrices and the characterization of their variations upon environmental changes are challenging. Depending on their properties hydrogels are applied as actuators, biosensors, in drug delivery, tissue engineering, or for medical coatings. However, the field of possible applications still shows potential to be expanded. rnSurface attached hydrogel films with a thickness of several micrometers can serve as waveguiding matrix for leaky optical waveguide modes. On the basis of highly swelling and waveguiding dextran based hydrogel films an optical biosensor concept was developed. The synthesis of a dextran based hydrogel matrix, its functionalization to modulate its response towards external stimuli, and the characterization of the swollen hydrogel films were main interests within this biosensor project. A second focus was the optimization of the hydrogel characteristics for cell growth with the aim of creating scaffolds for bone regeneration. Matrix modification towards successful cell growth experiments with endothelial cells and osteoblasts was achieved.rnA photo crosslinkable, carboxymethylated dextran based hydrogel (PCMD) was synthesized and characterized in terms of swelling behaviour and structural properties. Further functionalization was carried out before and after crosslinking. This functionalization aimed towards external manipulation of the swelling degree and the charge of the hydrogel matrix important for biosensor experiments as well as for cell adhesion. The modulation of functionalized PCMD hydrogel responses to pH, ion concentration, electrochemical switching, or a magnetic force was investigated. rnThe PCMD hydrogel films were optically characterized by combining surface plasmon resonance (SPR) and optical waveguide mode spectroscopy (OWS). This technique allows a detailed analysis of the refractive index profile perpendicular to the substrate surface by applying the Wentzel Kramers Brillouin (WKB) approximation. rnIn order to perform biosensor experiments, analyte capturing units such as proteins or antibodies were covalently coupled to the crosslinked hydrogel backbone by applying active ester chemistry. Consequently, target analytes could be located inside the waveguiding matrix. By using labeled analytes, fluorescence enhancement was achieved by fluorescence excitation with the electromagnetic field in the center of the optical waveguide modes. The fluorescence excited by the evanescent electromagnetic field of the surface plasmon was 2 3 orders of magnitude lower. Furthermore, the signal to noise ratio was improved by the fluorescence excitation with leaky optical waveguide modes.rnThe applicability of the PCMD hydrogel sensor matrix for clinically relevant samples was proofed in a cooperation project for the detection of PSA in serum with long range surface plasmon spectroscopy (LRSP) and fluorescence excitation by LRSP (LR SPFS). rn
Resumo:
Collinear laser spectroscopy has been used as a tool for nuclear physics for more than 30 years. The unique possibility to extract nuclear properties like spins, radii and nuclear moments in a model-independent manner leads to important physics results to test the predictive power of existing nuclear models. rnThis work presents the construction and the commissioning of a new collinear laser spectroscopy experiment TRIGA-LASER as a part of the TRIGA-SPEC facility at the TRIGA research reactor at the University of Mainz. The goal of the experiment is to study the nuclear structure of radioactive isotopes which will be produced by neutron-induced fission near the reactor core and transported to an ion source by a gas jet system. rnThe versatility of the collinear laser spectroscopy technique will be exploited in the second part of this thesis. The nuclear spin and the magnetic moment of the neutron-deficient isotope Mg-21 will be presented, which were measured by the detection of the beta-decay asymmetry induced by nuclear polarization after optical pumping. A combination of this detection method with the classical fluorescence detection is then used to determine the isotope shifts of the neutron-rich magnesium isotopes from Mg-24 through Mg-32 to study the transition to the ''island of inversion''.
Resumo:
Therapeutisches Drug Monitoring (TDM) findet Anwendung in der Therapie mit Immunosuppressiva, Antibiotika, antiretroviraler Medikation, Antikonvulsiva, Antidepressiva und auch Antipsychotika, um die Effizienz zu steigern und das Risiko von Intoxikationen zu reduzieren. Jedoch ist die Anwendung von TDM für Substanzen, die Einsatz finden in der Rückfallprophylaxe, der Substitution oder dem Entzug von Abhängigkeitserkrankungen nicht etabliert. Für diese Arbeit wurde im ersten Schritt eine sensitive Rating-Skala mit 22 Items entwickelt, mit Hilfe derer der theoretische Nutzen von TDM in der Pharmakotherapie von substanzbezogenen Abhängigkeitserkrankungen auf der Basis von pharmakologischen Eigenschaften der Medikamente und von Patientencharakteristika evaluiert wurde. Die vorgenommene Einschätzung zeigte für Bupropion, Buprenorphin, Disulfiram (oder einen Metaboliten), Methadon (chirale Bestimmung wenn möglich) und Naltrexon einen potentiellen Nutzen von TDM.rnFür die meisten Medikamente, die zur Behandlung von Abhängigkeitserkrankungen zugelassen sind, fehlen valide Messverfahren für TDM. Im Alltag werden überwiegend Drogen Screening-Tests in Form immunologischer Schnelltests angewendet. Für die Anwendung von TDM wurden in dieser Arbeit chromatographische Verfahren für die Bestimmung von Naltrexon und 6β-Naltrexol, Bupropion und Hydroxybupropion sowie R,S-Methadon und R,S-2-Ethyliden-1,5-dimethyl-3,3-diphenylpyrrolidin entwickelt, optimiert und validiert. Es handelt sich dabei HPLC-UV-Methoden mit Säulenschaltung sowie zur Bestimmung von Naltrexon und 6β-Naltrexol zusätzlich eine LC-MS/MS-Methode. Voraussetzung für die Interpretation der Plasmaspiegel ist im Wesentlichen die Kenntnis eines therapeutischen Bereichs. Für Naltrexon und seinen aktiven Metaboliten 6β-Naltrexol konnte eine signifikante Korrelation zwischen dem auftretenden Craving und der Summenkonzentration gefunden werden. Mittels Receiver-Operation-Characteristics-Kurven-Analyse wurde ein Schwellenwert von 16,6 ng/ml ermittelt, oberhalb dessen mit einem erhöhten Ansprechen gerechnet werden kann. Für Levomethadon wurde bezüglich der Detoxifikationsbehandlung ein Zusammenhang in der prozentualen Reduktion des Plasmaspiegels und den objektiven und subjektiven Entzugssymptomen gefunden. rnDoch nicht nur die Wirkstoffe, sondern auch das Patientenmerkmal substanzbezogene Abhängigkeit wurde charakterisiert, zum einen bezüglich pharmakokinetischer Besonderheiten, zum anderen in Hinsicht auf die Therapietreue (Adhärenz). Für Patienten mit komorbider Substanzabhängigkeit konnte eine verminderte Adhärenz unabhängig von der Hauptdiagnose gezeigt werden. Die Betrachtung des Einflusses von veränderten Leberwerten zeigt für komorbide Patienten eine hohe Korrelation mit dem Metabolisiererstatus, nicht aber für Patienten ohne Substanzabhängigkeit.rnÜbergeordnetes Ziel von TDM ist die Erhöhung der Therapiesicherheit und die Steigerung der Therapieeffizienz. Dies ist jedoch nur möglich, wenn TDM im klinischen Alltag integriert ist und korrekt eingesetzt wird. Obwohl es klare Evidenz für TDM von psychiatrischer Medikation gibt, ist die Diskrepanz zwischen Laborempfehlung und der klinischen Umsetzung hoch. Durch Intensivierung der interdisziplinären Zusammenarbeit zwischen Ärzten und Labor, der Entwicklung von interaktivem TDM (iTDM), konnte die Qualität der Anwendung von TDM verbessert und das Risiko von unerwünschten Arzneimittelwirkungen vermindert werden. rnInsgesamt konnte durch die eigenen Untersuchungen gezeigt werden, dass TDM für die medikamentöse Einstellung von Patienten mit Abhängigkeitserkrankung sinnvoll ist und dass optimales TDM eine interdisziplinäre Zusammenarbeit erfordert.rn
Resumo:
Die Elektronen in wasserstoff- und lithium-ähnlichen schweren Ionen sind den extrem starken elektrischen und magnetischen Feldern in der Umgebung des Kerns ausgesetzt. Die Laserspektroskopie der Hyperfeinaufspaltung im Grundzustand des Ions erlaubt daher einen sensitiven Test der Quantenelektrodynamik in starken Feldern insbesondere im magnetischen Sektor. Frühere Messungen an wasserstoffähnlichen Systemen die an einer Elektronenstrahl-Ionenfalle (EBIT) und am Experimentierspeicherring (ESR) der GSI Darmstadt durchgeführt wurden, waren in ihrer Genauigkeit durch zu geringe Statistik, einer starken Dopplerverbreiterung und der großen Unsicherheit in der Ionenenergie limitiert. Das ganze Potential des QED-Tests kann nur dann ausgeschöpft werden, wenn es gelingt sowohl wasserstoff- als auch lithium-ähnliche schwere Ionen mit einer um 2-3 Größenordnung gesteigerten Genauigkeit zu spektroskopieren. Um dies zu erreichen, wird gegenwärtig das neue Penningfallensystem SPECTRAP an der GSI aufgebaut und in Betrieb genommen. Es ist speziell für die Laserspektroskopie an gespeicherten hochgeladenen Ionen optimiert und wird in Zukunft von HITRAP mit nierderenergetischen hochgeladenen Ionen versorgt werden.rnrnSPECTRAP ist eine zylindrische Penningfalle mit axialem Zugang für die Injektion von Ionen und die Einkopplung eines Laserstrahls sowie einem radialen optischen Zugang für die Detektion der Fluoreszenz. Um letzteres zu realisieren ist der supraleitende Magnet als Helmholtz-Spulenpaar ausgelegt. Um die gewünschte Genauigkeit bei der Laserspektroskopie zu erreichen, muss ein effizienter und schneller Kühlprozess für die injizierten hochegeladenen Ionen realisiert werden. Dies kann mittels sympathetischer Kühlung in einer lasergekühlten Wolke leichter Ionen realisiert werden. Im Rahmen dieser Arbeit wurde ein Lasersystem und eine Ionenquelle für die Produktion einer solchen 24Mg+ Ionenwolke aufgebaut und erfolgreich an SPECTRAP in Betrieb genommen. Dazu wurde ein Festkörperlasersystem für die Erzeugung von Licht bei 279.6 nm entworfen und aufgebaut. Es besteht aus einem Faserlaser bei 1118 nm der in zwei aufeinanderfolgenden Frequenzverdopplungsstufen frequenzvervierfacht wird. Die Verdopplerstufen sind als aktiv stabilisierte Resonantoren mit nichtlinearen Kristallen ausgelegt. Das Lasersystem liefert unter optimalen Bedingeungen bis zu 15 mW bei der ultravioletten Wellenlänge und erwies sich während der Teststrahlzeiten an SPECTRAP als ausgesprochen zuverlässig. Desweiteren wurde eine Ionequelle für die gepulste Injektion von Mg+ Ionen in die SPECTRAP Falle entwickelt. Diese basiert auf der Elektronenstoßionisation eines thermischen Mg-Atomstrahls und liefert in der gepulsten Extraktion Ionenbündel mit einer kleinen Impuls- und Energieverteilung. Unter Nutzung des Lasersystems konnten damit an SPECTRAP erstmals Ionenwolken mit bis zu 2600 lasergekühlten Mg Ionen erzeugt werden. Der Nachweis erfolgte sowohl mittels Fluoreszenz als auch mit der FFT-ICR Technik. Aus der Analyse des Fluoreszenz-Linienprofils lässt sich sowohl die Sensitivität auf einzelne gespeicherte Ionen als auch eine erreichte Endtemperatur in der Größenordnung von ≈ 100 mK nach wenigen Sekunden Kühlzeit belegen.
Resumo:
The aim of this work is to provide a precise and accurate measurement of the 238U(n,gamma) reaction cross-section. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behaviour of the reactor core. In particular, fast neutron reactors, which are experiencing a growing interest for their ability to burn radioactive waste, operate in the high energy region of the neutron spectrum. In this energy region inconsistencies between the existing measurements are present up to 15%, and the most recent evaluations disagree each other. In addition, the assessment of nuclear data uncertainty performed for innovative reactor systems shows that the uncertainty in the radiative capture cross-section of 238U should be further reduced to 1-3% in the energy region from 20 eV to 25 keV. To this purpose, addressed by the Nuclear Energy Agency as a priority nuclear data need, complementary experiments, one at the GELINA and two at the n_TOF facility, were scheduled within the ANDES project within the 7th Framework Project of the European Commission. The results of one of the 238U(n,gamma) measurement performed at the n_TOF CERN facility are presented in this work, carried out with a detection system constituted of two liquid scintillators. The very accurate cross section from this work is compared with the results obtained from the other measurement performed at the n_TOF facility, which exploit a different and complementary detection technique. The excellent agreement between the two data-sets points out that they can contribute to the reduction of the cross section uncertainty down to the required 1-3%.
Resumo:
Die Invarianz physikalischer Gesetze unter Lorentztransformationen ist eines der fundamentalen Postulate der modernen Physik und alle Theorien der grundlegenden Wechselwirkungen sind in kovarianter Form formuliert. Obwohl die Spezielle Relativitätstheorie (SRT) in einer Vielzahl von Experimenten mit hoher Genauigkeit überprüft und bestätigt wurde, sind aufgrund der weitreichenden Bedeutung dieses Postulats weitere verbesserte Tests von grundsätzlichem Interesse. Darüber hinaus weisen moderne Ansätze zur Vereinheitlichung der Gravitation mit den anderen Wechselwirkungen auf eine mögliche Verletzung der Lorentzinvarianz hin. In diesem Zusammenhang spielen Ives-Stilwell Experimente zum Test der Zeitdilatation in der SRT eine bedeutende Rolle. Dabei wird die hochauflösende Laserspektroskopie eingesetzt, um die Gültigkeit der relativistischen Dopplerformel – und damit des Zeitdilatationsfaktors γ – an relativistischen Teilchenstrahlen zu untersuchen. Im Rahmen dieser Arbeit wurde ein Ives-Stilwell Experiment an 7Li+-Ionen, die bei einer Geschwindigkeit von 34 % der Lichtgeschwindigkeit im Experimentierspeicherring (ESR) des GSI Helmholtzzentrums für Schwerionenforschung gespeichert waren, durchgeführt. Unter Verwendung des 1s2s3S1→ 1s2p3P2-Übergangs wurde sowohl Λ-Spektroskopie als auch Sättigungsspektroskopie betrieben. Durch die computergestützte Analyse des Fluoreszenznachweises und unter Verwendung optimierter Kantenfilter für den Nachweis konnte das Signal zu Rauschverhältnis entscheidend verbessert und unter Einsatz eines zusätzlichen Pumplasers erstmals ein Sättigungssignal beobachtet werden. Die Frequenzstabilität der beiden verwendeten Lasersysteme wurde mit Hilfe eines Frequenzkamms spezifiziert, um eine möglichst hohe Genauigkeit zu erreichen. Die aus den Strahlzeiten gewonnen Daten wurden im Rahmen der Robertson-Mansouri-Sexl-Testtheorie (RMS) und der Standard Model Extension (SME) interpretiert und entsprechende Obergrenzen für die relevanten Testparameter der jeweiligen Theorie bestimmt. Die Obergrenze für den Testparameter α der RMS-Theorie konnte gegenüber den früheren Messungen bei 6,4 % der Lichtgeschwindigkeit am Testspeicherring (TSR) des Max-Planck-Instituts für Kernphysik in Heidelberg um einen Faktor 4 verbessert werden.
Resumo:
Das in dieser Arbeit vorgestellte Experiment zur Messung des magnetischen Moments des Protons basiert auf der Messung des Verhältnisses von Zyklotronfrequenz und Larmorfrequenz eines einzelnen, in einer kryogenen Doppel-Penning Falle gespeicherten Protons. In dieser Arbeit konnten erstmalig zwei der drei Bewegungsfrequenzen des Protons gleichzeitig im thermischen Gleichgewicht mit entsprechenden hochsensitiven Nachweissystemen nicht-destruktiv detektiert werden, wodurch die Messzeit zur Bestimmung der Zyklotronfrequenz halbiert werden konnte. Ferner wurden im Rahmen dieser Arbeit erstmalig einzelne Spin-Übergänge eines einzelnen Protons detektiert, wodurch die Bestimmung der Larmorfrequenz ermöglicht wird. Mithilfe des kontinuierlichen Stern-Gerlach Effekts wird durch eine sogenannte magnetische Flasche das magnetische Moment an die axiale Bewegungsmode des Protons gekoppelt. Eine Änderung des Spinzustands verursacht folglich einen Frequenzsprung der axialen Bewegungsfrequenz, welche nicht-destruktiv gemessen werden kann. Erschwert wird die Detektion des Spinzustands dadurch, dass die axiale Frequenz nicht nur vom Spinmoment, sondern auch vom Bahnmoment abhängt. Die große experimentelle Herausforderung besteht also in der Verhinderung von Energieschwankungen in den radialen Bewegungsmoden, um die Detektierbarkeit von Spin-Übergängen zu gewährleisten. Durch systematische Studien zur Stabilität der axialen Frequenz sowie einer kompletten Überarbeitung des experimentellen Aufbaus, konnte dieses Ziel erreicht werden. Erstmalig kann der Spinzustand eines einzelnen Protons mit hoher Zuverlässigkeit bestimmt werden. Somit stellt diese Arbeit einen entscheidenden Schritt auf dem Weg zu einer hochpräzisen Messung des magnetischen Moments des Protons dar.
Resumo:
Aerosol particles are important actors in the Earth’s atmosphere and climate system. They scatter and absorb sunlight, serve as nuclei for water droplets and ice crystals in clouds and precipitation, and are a subject of concern for public health. Atmospheric aerosols originate from both natural and anthropogenic sources, and emissions resulting from human activities have the potential to influence the hydrological cycle and climate. An assessment of the extent and impacts of this human force requires a sound understanding of the natural aerosol background. This dissertation addresses the composition, properties, and atmospheric cycling of biogenic aerosol particles, which represent a major fraction of the natural aerosol burden. The main focal points are: (i) Studies of the autofluo-rescence of primary biological aerosol particles (PBAP) and its application in ambient measure-ments, and (ii) X-ray microscopic and spectroscopic investigations of biogenic secondary organic aerosols (SOA) from the Amazonian rainforest.rnAutofluorescence of biological material has received increasing attention in atmospheric science because it allows real-time monitoring of PBAP in ambient air, however it is associated with high uncertainty. This work aims at reducing the uncertainty through a comprehensive characterization of the autofluorescence properties of relevant biological materials. Fluorescence spectroscopy and microscopy were applied to analyze the fluorescence signatures of pure biological fluorophores, potential non-biological interferences, and various types of reference PBAP. Characteristic features and fingerprint patterns were found and provide support for the operation, interpretation, and further development of PBAP autofluorescence measurements. Online fluorescence detection and offline fluorescence microscopy were jointly applied in a comprehensive bioaerosol field measurement campaign that provided unprecedented insights into PBAP-linked biosphere-atmosphere interactions in a North-American semi-arid forest environment. Rain showers were found to trigger massive bursts of PBAP, including high concentrations of biological ice nucleators that may promote further precipitation and can be regarded as part of a bioprecipitation feedback cycle in the climate system. rnIn the pristine tropical rainforest air of the Amazon, most cloud and fog droplets form on bio-genic SOA particles, but the composition, morphology, mixing state and origin of these particles is hardly known. X-ray microscopy and spectroscopy (STXM-NEXAFS) revealed distinctly different types of secondary organic matter (carboxyl- vs. hydroxy-rich) with internal structures that indicate a strong influence of phase segregation, cloud and fog processing on SOA formation, and aging. In addition, nanometer-sized potassium-rich particles emitted by microorganisms and vegetation were found to act as seeds for the condensation of SOA. Thus, the influence of forest biota on the atmospheric abundance of cloud condensation nuclei appears to be more direct than previously assumed. Overall, the results of this dissertation suggest that biogenic aerosols, clouds and precipitation are indeed tightly coupled through a bioprecipitation cycle, and that advanced microscopic and spectroscopic techniques can provide detailed insights into these mechanisms.rn
Resumo:
Die theoretische und experimentelle Untersuchung von wasserstoffähnlichen Systemen hat in den letzten hundert Jahren immer wieder sowohl die experimentelle als auch die theoretische Physik entscheidend vorangebracht. Formulierung und Test der Quantenelektrodynamik (QED) standen und stehen in engen Zusammenhang mit der Untersuchung wasserstoffähnlicher Systeme. Gegenwärtig sind besonders wasserstoffähnliche Systeme schwerer Ionen von Interesse, um die QED in den extrem starken Feldern in Kernnähe zu testen. Laserspektroskopische Messungen der Hyperfeinstrukturaufspaltung des Grundzustandes bieten eine hohe Genauigkeit, ihre Interpretation wird jedoch durch die Unsicherheit in der Größe der Kernstruktureffekte erschwert. Beseitigt werden können diese durch die Kombination der Aufspaltung in wasserstoff- und lithiumähnlichen Ionen des gleichen Nuklids. In den letzten zwei Jahrzehnten scheiterten mehrere dadurch motivierte Versuche, den HFS-Übergang in lithiumähnlichen 209Bi80+ zu finden. Im Rahmen dieser Arbeit wurde kollineare Laserspektroskopie bei etwa 70% der Lichtgeschwindigkeit an 209Bi82+ und 209Bi80+ -Ionen im Experimentier- Speicherring an der GSI in Darmstadt durchgeführt. Dabei wurde der Übergang im lithiumähnlichen Bismut erstmals beobachtet und dessen Übergangswellenlänge zu 1554,74(74) nm bestimmt. Ein eigens für dieses Experiment optimiertes Fluoreszenz-Nachweissystem stellte dabei die entscheidende Verbesserung gegenüber den gescheiterten Vorgängerexperimenten dar. Der Wellenlängenfehler ist dominiert von der Unsicherheit der Ionengeschwindigkeit, die für die Transformation in das Ruhesystem der Ionen entscheidend ist. Für deren Bestimmung wurden drei Ansätze verfolgt: Die Geschwindigkeit wurde aus der Elektronenkühlerspannung bestimmt, aus dem Produkt von Orbitlänge und Umlauffrequenz und aus dem relativistischen Dopplereffekt unter Annahme der Korrektheit des früher bestimmten Überganges in wasserstoffähnlichen Bismut. Die Spannungskalibration des Elektronenkühlers wurde im Rahmen dieser Arbeit erstmals kritisch evaluiert und bislang unterschätzte systematische Unsicherheiten aufgezeigt, die derzeit einen aussagekräftigen QED-Test verhindern. Umgekehrt konnte unter Verwendung der QED-Berechnungen eine Ionengeschwindigkeit berechnet werden, die ein genaueres und konsistenteres Resultat für die Übergangswellenlängen beider Ionenspezies liefert. Daraus ergibt sich eine Diskrepanz zu dem früher bestimmten Wert des Überganges in wasserstoffähnlichen Bismut, die es weiter zu untersuchen gilt.
Resumo:
In the current work, three studies about non-aqueous dispersions of particles were carried out by using an amphiphilic block copolymer poly(isoprene)-block-poly(methyl methacrylate) (PI-b-PMMA) as stabilizer:rn1. Dispersions of polyurethane and polyurea porous particles for polymer compositesrn2. Dispersions of PMMA and PU particles with PDI dye for study of Single Molecule Spectroscopy Detectionrn3. Dispersions of graphene nanosheets for polymer compositesrnrnIn the first study, highly porous polyurethane and polyurea particles were prepared in a non-aqueous emulsion. The preparation of porous particles consisted of two parts: At first, a system was developed where the emulsion had high stability for the polymerization among diisocyanate, diol and water. In the second part, porous particles were prepared by using two methods fission/fusion and combination by which highly porous particles were obtained. In this study, the applications of porous particles were also investigated where polyurethane particles were tested as filling material for polymer composites and as catalyst carrier for polyethylene polymerization. rnrnIn the second study, PMMA and PU particles from one non-aqueous emulsion were investigated via single molecule fluorescence detection. At first the particles were loaded with PDI dye, which were detected by fluorescence microscopy. The distribution and orientation of the PDI molecules in the particles were successfully observed by Single Molecule Fluorescence Detection. The molecules were homogenously distributed inside of the particles. In addition they had random orientation, meaning that no aggregations of dye molecules were formed. With the results, it could be supposed that the polymer chains were also homogenously distributed in the particles, and that the conformation was relatively flexible. rnrnIn the third part of the study, graphene nanosheets with high surface area were dispersed in an organic solvent with low boiling point and low toxicity, THF, stabilized with a block copolymer PI-b-PMMA. The dispersion was used to prepare polymer composites. It was shown that the modified graphene nanosheets had good compatibility with the PS and PMMA matrices. rn
Resumo:
The combination of advanced ultraperformance liquid chromatography coupled with mass spectrometry, chemometrics, and genetically modified mice provide an attractive raft of technologies with which to examine the metabolism of xenobiotics. Here, a reexamination of the metabolism of the food mutagen PhIP (2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine), the suspect carcinogen areca alkaloids (arecoline, arecaidine, and arecoline 1-oxide), the hormone supplement melatonin, and the metabolism of the experimental cancer therapeutic agent aminoflavone is presented. In all cases, the metabolic maps of the xenobiotics were considerably enlarged, providing new insights into their toxicology. The inclusion of transgenic mice permitted unequivocal attribution of individual and often novel metabolic pathways to particular enzymes. Last, a future perspective for xenobiotic metabolomics is discussed and its impact on the metabolome is described. The studies reviewed here are not specific to the mouse and can be adapted to study xenobiotic metabolism in any animal species, including humans. The view through the metabolometer is unique and visualizes a metabolic space that contains both established and unknown metabolites of a xenobiotic, thereby enhancing knowledge of their modes of toxic action.
Resumo:
To enhance understanding of the metabolic indicators of type 2 diabetes mellitus (T2DM) disease pathogenesis and progression, the urinary metabolomes of well characterized rhesus macaques (normal or spontaneously and naturally diabetic) were examined. High-resolution ultra-performance liquid chromatography coupled with the accurate mass determination of time-of-flight mass spectrometry was used to analyze spot urine samples from normal (n = 10) and T2DM (n = 11) male monkeys. The machine-learning algorithm random forests classified urine samples as either from normal or T2DM monkeys. The metabolites important for developing the classifier were further examined for their biological significance. Random forests models had a misclassification error of less than 5%. Metabolites were identified based on accurate masses (<10 ppm) and confirmed by tandem mass spectrometry of authentic compounds. Urinary compounds significantly increased (p < 0.05) in the T2DM when compared with the normal group included glycine betaine (9-fold), citric acid (2.8-fold), kynurenic acid (1.8-fold), glucose (68-fold), and pipecolic acid (6.5-fold). When compared with the conventional definition of T2DM, the metabolites were also useful in defining the T2DM condition, and the urinary elevations in glycine betaine and pipecolic acid (as well as proline) indicated defective re-absorption in the kidney proximal tubules by SLC6A20, a Na(+)-dependent transporter. The mRNA levels of SLC6A20 were significantly reduced in the kidneys of monkeys with T2DM. These observations were validated in the db/db mouse model of T2DM. This study provides convincing evidence of the power of metabolomics for identifying functional changes at many levels in the omics pipeline.
Resumo:
ThioTEPA, an alkylating agent with anti-tumor activity, has been used as an effective anticancer drug since the 1950s. However, a complete understanding of how its alkylating activity relates to clinical efficacy has not been achieved, the total urinary excretion of thioTEPA and its metabolites is not resolved, and the mechanism of formation of the potentially toxic metabolites S-carboxymethylcysteine (SCMC) and thiodiglycolic acid (TDGA) remains unclear. In this study, the metabolism of thioTEPA in a mouse model was comprehensively investigated using ultra-performance liquid chromatography coupled with electrospray ionization quadrupole time-of-flight mass spectrometry (UPLC-ESI-QTOFMS) based-metabolomics. The nine metabolites identified in mouse urine suggest that thioTEPA underwent ring-opening, N-dechloroethylation, and conjugation reactions in vivo. SCMC and TDGA, two downstream thioTEPA metabolites, were produced from thioTEPA from two novel metabolites 1,2,3-trichloroTEPA (VII) and dechloroethyltrichloroTEPA (VIII). SCMC and TDGA excretion were increased about 4-fold and 2-fold, respectively, in urine following the thioTEPA treatment. The main mouse metabolites of thioTEPA in vivo were TEPA (II), monochloroTEPA (III) and thioTEPA-mercapturate (IV). In addition, five thioTEPA metabolites were detected in serum and all shared similar disposition. Although thioTEPA has a unique chemical structure which is not maintained in the majority of its metabolites, metabolomic analysis of its biotransformation greatly contributed to the investigation of thioTEPA metabolism in vivo, and provides useful information to understand comprehensively the pharmacological activity and potential toxicity of thioTEPA in the clinic.