930 resultados para BIOMEDICAL RADIOGRAPHY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a hybrid numerical method for the design of asymmetric magnetic resonance imaging magnet systems. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. A new type of asymmetric magnet is proposed in this work. The asymmetric MRI magnet allows the diameter spherical imaging volume to be positioned close to one end of the magnet. The main advantages of making the magnet asymmetric include the potential to reduce the perception of claustrophobia for the patient, better access to the patient by attending physicians, and the potential for reduced peripheral nerve stimulation due to the gradient coil configuration. The results highlight that the method can be used to obtain an asymmetric MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1.2 m in length. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 1999 Academic Press.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present paper reviews research in the area of the broad-spectrum chemotherapeutic agent cisplatin (cis-diamminedichloro-platinum II) and examines the implications for clinical neuropsychology arising from the neurological disruption associated with cisplatin-based therapy. The paper begins with a brief review of cisplatin treatment in terms other than survival alone, and examines the side-effects and the potential central nervous system (CNS) dysfunction in terms of neurological symptoms and concomitant implications for neuropsychology. Two main implications for clinical neuropsychology arising from cisplatin therapy are identified. First, cisplatin therapy impacts upon the psychological well-being of the patient, particularly during and in the months following treatment. It is suggested that during this time, a primary role for neuropsychology is to focus upon the monitoring and the active enhancement of the patient's social, psychological and spiritual resources. Second, with regard to neurocognitive changes, the review suggests that (1) neurocognitive assessment may not yield stable results within 8 months following treatment and (2) while perceptual, memory, attentional and executive dysfunction may be predicted following cisplatin treatment, little systematic research has been carried out to investigate such a possibility. Future research might profitably address this issue and also specifically examine the effects of low dosage cisplatin-based therapy and the effects of recently developed neuroprotective agents. Finally, there is some evidence to suggest that women may be more susceptible to neurotoxicity during cisplatin therapy, but no gender-related cognitive effects are reported in the cisplatin literature. Future research could usefully investigate gender differences in association with cisplatin chemotherapy. Copyright (C) 2000 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a hybrid numerical method of an inverse approach to the design of compact magnetic resonance imaging magnets. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first, kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. The emphasis of this work is on the optimal design of short MRI magnets. Details of the hybrid numerical model are presented, and the model is used to investigate compact, symmetric MRI magnets as well as asymmetric magnets. The results highlight that the method can be used to obtain a compact MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1 m in length, significantly shorter than current designs. Viable asymmetric magnet designs, in which the edge of the homogeneous region is very close to one end of the magnet system are also presented. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00303-5].

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method is presented for including path propagation effects into models of radiofrequency resonators for use in magnetic resonance imaging. The method is based on the use of Helmholtz retarded potentials and extends our previous work on current density models of resonators based on novel inverse finite Hilbert transform solutions to the requisite integral equations. Radiofrequency phase retardation effects are most pronounced at high field strengths (frequencies) as are static field perturbations due to the magnetic materials in the resonators themselves. Both of these effects are investigated and a novel resonator structure presented for use in magnetic resonance microscopy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Over recent years databases have become an extremely important resource for biomedical research. Immunology research is increasingly dependent on access to extensive biological databases to extract existing information, plan experiments, and analyse experimental results. This review describes 15 immunological databases that have appeared over the last 30 years. In addition, important issues regarding database design and the potential for misuse of information contained within these databases are discussed. Access pointers are provided for the major immunological databases and also for a number of other immunological resources accessible over the World Wide Web (WWW). (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A longitudinal study of 144 patents (65 fathers, 79 mothers) was conducted to evaluate the effectiveness of a program of intervention in relieving the psychological distress of parents affected by infant death. Participants were assessed in terms of their psychiatric disturbance, depression, anxiety, physical symptoms, dyadic adjustment, and coping strategies. The experimental group (n = 84) was offered an intervention program comprising the use of specially designed resources and contact with a trained grief worker. A control group (n = 60) was given routine community care. Parental reactions were assessed at four to six weeks postloss (prior to the implementation of the intervention program), at six months postloss, and at 15 months postloss. A series of multivariate analyses of valiance revealed that the intervention was effective in reducing the distress of parents, particularly those assessed prior to the intervention as being at high-risk of developing mourning difficulties. Effects of the intervention were noted in terms of parents' overall psychiatric disturbance, marital quality, and paternal coping strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The increasing emphasis on evidence-based clinical practice has thrown into sharp focus multiple deficiencies in current systems of ethical review. This paper argues that a complete overhaul of systems for ethical oversight of studies involving human subjects is now required as developments in medical, epidemiological and genetic research have outstripped existing structures for ethical supervision. It shows that many problems are now evident and concludes that sequential and piecemeal amendments to present arrangements an inadequate to address these. Ar their core present systems of ethical review still rely on the integrity and judgement of individual investigators. One possible alternative is to train and license research investigators, make explicit their responsibilities and have ethics committees devote much more of their time to monitoring research activity in order to detect those infringing the rules.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To establish the prevalence and predictors of genital warts among healthy women presenting for contraceptive advice at two family planning clinics, one in a major Australian city and one in a country town in the same state. Methods: Consecutive consenting attendees (n = 1218)at two family planning clinics in Queensland completed a questionnaire and were examined for genital warts. Results: The point prevalence of visible genital warts was 3.3 per cent in the city clinic and 14.4 per cent in the country town. For half of these clients a finding of warts was unexpected, in that the client was unaware of their presence and presentation to the family planning clinic was not specifically for advice about sexually transmitted infections. The major predictor of a finding of warts was client age, with the highest prevalence in 20- to 25-year-olds. Warts were also commoner amongst smokers in the country town but not in Brisbane. However, no analysed sociodemographic variable predicted a finding of warts of which the client was not aware. Conclusions: Genital warts are common among young women presenting for contraceptive advice. Such women are often unaware that they have warts. Examination for genital warts should be a part of any routine examination of sexually active women, and medical practitioners should be aware of appropriate advice for patients who are found to have genital warts on routine examination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In humans, intra-abdominal pressure (IAP) is elevated during many everyday activities. This experiment aimed to investigate the extent to which increased IAP-without concurrent activity of the abdominal or back extensor muscles-produces an extensor torque. With subjects positioned in side lying on a swivel table with its axis at L3, moments about this vertebral level were measured when IAP was transiently increased by electrical stimulation of the diaphragm via the phrenic nerve. There was no electromyographic activity in abdominal and back extensor muscles. When IAP was increased artificially to similar to 15% of the maximum IAP amplitude that could be generated voluntarily with the trunk positioned in flexion, a trunk extensor moment (similar to6 Nm) was recorded. The size of the effect was proportional to the increase in pressure. The extensor moment was consistent with that predicted from a model based on measurements of abdominal cross-sectional area and IAP moment arm. When IAP was momentarily increased while the trunk was flexed passively at a constant velocity, the external torque required to maintain the velocity was increased. These results provide the first in vivo data of the amplitude of extensor moment that is produced by increased IAP. Although the net effect of this extensor torque in functional tasks would be dependent on the muscles used to increase the IAP and their associated flexion torque, the data do provide evidence that IAP contributes, at least in part, to spinal stability. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of ionizing radiation in different compositions of polymer gel dosimeters are investigated using FT-Raman spectroscopy and NMR T-2 relaxation times. The dosimeters are manufactured from different concentrations of comonomers (acrylamide and N,N'-methylene-bis-acrylamide) dispersed in different concentrations of an aqueous gelatin matrix. Results are analysed using a model of fast exchange of magnetization between three proton pools. The fraction of protons in each pool is determined using the known chemical composition of the dosimeter and FT-Raman spectroscopy. Based on these results, the physical and chemical processes in interplay in the dosimeters are examined in view of their effect on the changes in T-2 The precipitation of growing macroradicals and the scavenging of free radicals by gelatin are used to explain the rate of polymerization. The model describes the changes in T-2 as a function of the absorbed dose up to 50 Gy for the different compositions. This is expected to aid the theoretical design of new, more efficient dosimeters, since it was demonstrated that the optimum dosimeter (i.e, with the lowest dose resolution) must have a range of relaxation times which match the range of T-2 values which can be determined with the lowest uncertainty using an MRI scanner.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Over the past decade fatal opioid overdose has emerged as a major public health issue internationally. This paper examines the risk factors for overdose from a biomedical perspective. while significant risk factors for opioid overdose fatality are well recognized, the mechanism of fatal overdose remains unclear. Losses of tolerance and concomitant use of alcohol and other CNS depressants clearly play a major role in fatality; howeve, such risk factors do not account for the strong age and gender patterns observed consistently among victims of overdose. There is evidence that systemic disease may be more prevalent in users at greatest risk of overdose. We hypothesize that pulmonary and hepatic dysfunction resulting from such disease may increase susceptibility to both fatal and non-fatal overdose. Sequelae of non-fatal overdose are recognized in the clinical literature but few epidemiological data exist describing the burden of morbidity arising from such sequelae. The potential for overdose to cause persisting morbidity is reviewed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The nuclear magnetic resonance (NMR) spin-spin relaxation time (T-2) is related to the radiation-dependent concentration of polymer formed in polymer gel dosimeters manufactured from monomers in an aqueous gelatin matrix. Changes in T-2 with time post-irradiation have been reported in the literature but their nature is not fully understood. We investigated those changes with time after irradiation using FT-Raman spectroscopy and the precise determination of T-2 at high magnetic field in a polymer gel dosimeter, A model of fast exchange of magnetization taking into account ongoing gelation and strengthening of the gelatin matrix as well as the polymerization of the monomers with time is presented. Published data on the changes of T-2 in gelatin gels as a function of post-manufacture time are used and fitted closely by the model presented. The same set of parameters characterizing the variations of T-2 in gelatin gels and the increasing concentration of polymer determined from Fr-Raman spectroscopy are used successfully in the modelling of irradiated polymer gel dosimeters. Minimal variations in T-2 in an irradiated PAG dosimeter are observed after 13 h.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An inverse methodology is described to assist in the design of radio-frequency (RF) coils for magnetic resonance imaging (MRI) applications. The time-harmonic electromagnetic Green's functions are used to calculate current on the coil and shield cylinders that will generate a specified internal magnetic field. Stream function techniques and the method of moments are then used to implement this theoretical current density into an RF coil. A novel asymmetric coil operating for a 4.5 T MRI machine was designed and constructed using this methodology and the results are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study quantified the release of monomers from polymerized specimens of four commercially available resin composites and one glass ionomer cement immersed in water:ethanol solutions. Individual standard curves were prepared from five monomers: (1) triethylene glycol dimethacrylate (TEGDMA), (2) 2-hydroxy-ethyl methacrylate (HEMA), (3) urethane dimethacrylate (UDMA), (4) bisphenol A glycidyl dimethacrylate (BISGMA), and (5) bisphenol A. The concentration of the monomers was determined at Days 1, 7, 30, and 90 with the use of electrospray ionization/mass spectrometry. Data were expressed in mean mumol per mm(2) surface area of specimen and analyzed with Scheffe's test (P < 0.05). The following monomers were found in water: monomers (1) and (2) from Delton sealant, monomer (5) from ScotchBond Multipurpose Adhesive and Delton sealant, monomer (3) from Definite and monomer (4) from Fuji II LC, ScotchBond Multipurpose Adhesive, Synergy and Definite. All these monomers increased in concentration over time, with the exception of monomer (1) from Delton sealant. Monomers (3) and (5) were found in extracts of materials despite their absence from the manufacturer's published composition. All monomers were released in significantly higher concentrations in water:ethanol solutions than in water. The greatest release of monomers occurred in the first day. The effect of the measured concentrations of monomers (1-5) on human genes, cells, or tissues needs to be considered with the use of a biological model. (C) 2002 Wiley Periodicals, Inc.