975 resultados para Abdominal aorta
Resumo:
Objective:To evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis.Materials and Methods:Retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis.Results:Abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients.Conclusion:Computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis.
Resumo:
AbstractTuberculosis is a disease whose incidence has increased principally as a consequence of HIV infection and use of immunosuppressive drugs. The abdomen is the most common site of extrapulmonary tuberculosis. It may be confused with several different conditions such as inflammatory bowel disease, cancer and other infectious diseases. Delay in the diagnosis may result in significantly increased morbidity, and therefore an early recognition of the condition is essential for proper treatment. In the present essay, cases with confirmed diagnosis of abdominal tuberculosis were assessed by means of computed tomography and magnetic resonance imaging, demonstrating the involvement of different organs and systems, and presentations which frequently lead radiologists to a diagnostic dilemma. A brief literature review was focused on imaging findings and their respective prevalence.
Resumo:
AbstractObjective:To assess the reduction of estimated radiation dose in abdominal computed tomography following the implementation of new scan protocols on the basis of clinical suspicion and of adjusted images acquisition parameters.Materials and Methods:Retrospective and prospective review of reports on radiation dose from abdominal CT scans performed three months before (group A – 551 studies) and three months after (group B – 788 studies) implementation of new scan protocols proposed as a function of clinical indications. Also, the images acquisition parameters were adjusted to reduce the radiation dose at each scan phase. The groups were compared for mean number of acquisition phases, mean CTDIvol per phase, mean DLP per phase, and mean DLP per scan.Results:A significant reduction was observed for group B as regards all the analyzed aspects, as follows: 33.9%, 25.0%, 27.0% and 52.5%, respectively for number of acquisition phases, CTDIvol per phase, DLP per phase and DLP per scan (p < 0.001).Conclusion:The rational use of abdominal computed tomography scan phases based on the clinical suspicion in conjunction with the adjusted images acquisition parameters allows for a 50% reduction in the radiation dose from abdominal computed tomography scans.
Resumo:
Abstract Objective: To estimate the prevalence and evaluate sonographic findings compatible with changes consistent with hepatic steatosis in patients referred for abdominal ultrasonography at four reference centers in Aracaju, SE, Brazil. Materials and Methods: Prospective, descriptive survey, with analytical and quantitative approach, comprising abdominal ultrasonography scans performed with a convex, dynamic 3.75 MHz transducer. Liver dimensions and parenchymal echotexture were evaluated, classifying hepatic steatosis into grades (1, 2 or 3). The SPSS® 22.0 software was used for statistical analysis, adopting p < 0.05 as significance level. Results: A total of 800 individuals (561 women and 239 men) were evaluated. The prevalence of steatosis was 29.1%, and the male patients were most affected, presenting with more advanced grades of disease (p = 0.021), as follows: 119 grade 1 (51.0%); 94 grade 2 (40.4%); and 20 grade 3 (8.6%). The median age patients' was 46 years. Conclusion: In the present study sample, the prevalence of hepatic steatosis was high, particularly in the male patients. Ultrasonography is suggested as a first choice for the diagnosis of this condition, considering its wide availability, low cost and absence of side effects or risks to the patient.
Resumo:
Apart from its role as a flow generator for ventilation the diaphragm has a circulatory role. The cyclical abdominal pressure variations from its contractions cause swings in venous return from the splanchnic venous circulation. During exercise the action of the abdominal muscles may enhance this circulatory function of the diaphragm. Eleven healthy subjects (25 ± 7 year, 70 ± 11 kg, 1.78 ± 0.1 m, 3 F) performed plantar flexion exercise at ~4 METs. Changes in body volume (ΔVb) and trunk volume (ΔVtr) were measured simultaneously by double body plethysmography. Volume of blood shifts between trunk and extremities (Vbs) was determined non-invasively as ΔVtr-ΔVb. Three types of breathing were studied: spontaneous (SE), rib cage (RCE, voluntary emphasized inspiratory rib cage breathing), and abdominal (ABE, voluntary active abdominal expiration breathing). During SE and RCE blood was displaced from the extremities into the trunk (on average 0.16 ± 0.33 L and 0.48 ± 0.55 L, p < 0.05 SE vs. RCE), while during ABE it was displaced from the trunk to the extremities (0.22 ± 0.20 L p < 0.001, p < 0.05 RCE and SE vs. ABE respectively). At baseline, Vbs swings (maximum to minimum amplitude) were bimodal and averaged 0.13 ± 0.08 L. During exercise, Vbs swings consistently increased (0.42 ± 0.34 L, 0.40 ± 0.26 L, 0.46 ± 0.21 L, for SE, RCE and ABE respectively, all p < 0.01 vs. baseline). It follows that during leg exercise significant bi-directional blood shifting occurs between the trunk and the extremities. The dynamics and partitioning of these blood shifts strongly depend on the relative predominance of the action of the diaphragm, the rib cage and the abdominal muscles. Depending on the partitioning between respiratory muscles for the act of breathing, the distribution of blood between trunk and extremities can vary by up to 1 L. We conclude that during exercise the abdominal muscles and the diaphragm might play a role of an "auxiliary heart."
Resumo:
The hexane and methanolic extracts from pheromonal glands of Castnia licus (Drury) virgin females have been studied. Analyses by gas chromatography and mass spectrometry allowed us to determine the major constituents present in the hexane extract as n-alkanes C21 to C30, (Z)-9-hexadecenoic acid (C16), and (Z)-9-octadecenoic acid (C18) and hexadecanoic acid (C16). Aldehyds, alkenes and acetates were also detected in low concentrations in the extracts. Female pheromone glands were analysed for pheromone precursors using the methanolic extract. In addition to the compounds methyl hexadecanoate and methyl (Z)-9-octadecenoate, the glandular tissue contains a homologous series of methyl esters from C12 to C24. The hexane extract of the female abdomenal glands elicited activity from males in a behavioural bioassay.
Resumo:
Blood flow in human aorta is an unsteady and complex phenomenon. The complex patterns are related to the geometrical features like curvature, bends, and branching and pulsatile nature of flow from left ventricle of heart. The aim of this work was to understand the effect of aorta geometry on the flow dynamics. To achieve this, 3D realistic and idealized models of descending aorta were reconstructed from Computed Tomography (CT) images of a female patient. The geometries were reconstructed using medical image processing code. The blood flow in aorta was assumed to be laminar and incompressible and the blood was assumed to be Newtonian fluid. A time dependent pulsatile and parabolic boundary condition was deployed at inlet. Steady and unsteady blood flow simulations were performed in real and idealized geometries of descending aorta using a Finite Volume Method (FVM) code. Analysis of Wall Shear Stress (WSS) distribution, pressure distribution, and axial velocity profiles were carried out in both geometries at steady and unsteady state conditions. The results obtained in thesis work reveal that the idealization of geometry underestimates the values of WSS especially near the region with sudden change of diameter. However, the resultant pressure and velocity in idealized geometry are close to those in real geometry
Resumo:
The study evaluates the quality of abdominal surgical nursing care. The data were collected from patients (n=1208) having undergone abdominal surgical operations on their last day of hospitalization and nurses (n=218) working in the same wards. Three instruments originally created in Finland and adapted to the Lithuanian context were used: (1) Good Nursing Care Scale for patients and nurses (GNCS-P, GNCS-N), (2) Nurse Competence Scale (NCS), and (3) Nurse Empowerment Scale (NES). Patient and nurses’ perceptions of the quality of nursing care were evaluated. In addition, nurses’ perceptions of their competence and empowerment were evaluated. The patient and nurses' perceptions of the quality of abdominal surgical nursing care were positive, with more criticism in the nurses’ perceptions. Both patients and nurses gave the lowest evaluation to the quality in the progress of nursing care and the co-operation with significant others. The nurses gave the highest evaluation to the self-assessed level of their competence and the frequency of using competences in practice, with the highest assessment given to situation management and their role at work and the lowest to teaching-coaching and ensuring quality. The nurse perceptions of their empowerment were positive in the qualities and performance of an empowered nurse and empowerment promoting factors, with the highest evaluation in moral principles and sociability and the lowest evaluation in the future-orientedness and expertise. The empowerment-impeding factors were evaluated as negative. The perceptions of the quality of nursing care of both patients and nurses had significant correlations with patient and nurse satisfaction and nurse job independence. The nurse perceptions of their competence and empowerment correlated with their education, the type of the nurse license, completed courses of development of their knowledge and skills, nurse job independence, and nurse satisfaction. The nurse perceptions of the quality of nursing care had a positive correlation with their perceptions of competence and empowerment. Generally, the quality of nursing care was evaluated as high and had correlations with the patients' demographic and satisfaction factors and with the nurse demographic, work-related, and satisfaction factors. The study produced the knowledge that the quality in co-operation with significant others and the progress of nursing process, surgical nurse competence in teaching-coaching, and future-orientedness of surgical nurse empowerment need to be improved in order to develop the quality of abdominal surgical nursing care. The knowledge may be used to offer better services for abdominal surgical patients and increase their satisfaction with nursing care, as well as to increase nurses' satisfaction with work and independence at work. The study suggests implications for clinical practice and management, nursing education, and nursing research.
Resumo:
The aim of this study was to simulate blood flow in thoracic human aorta and understand the role of flow dynamics in the initialization and localization of atherosclerotic plaque in human thoracic aorta. The blood flow dynamics in idealized and realistic models of human thoracic aorta were numerically simulated in three idealized and two realistic thoracic aorta models. The idealized models of thoracic aorta were reconstructed with measurements available from literature, and the realistic models of thoracic aorta were constructed by image processing Computed Tomographic (CT) images. The CT images were made available by South Karelia Central Hospital in Lappeenranta. The reconstruction of thoracic aorta consisted of operations, such as contrast adjustment, image segmentations, and 3D surface rendering. Additional design operations were performed to make the aorta model compatible for the numerical method based computer code. The image processing and design operations were performed with specialized medical image processing software. Pulsatile pressure and velocity boundary conditions were deployed as inlet boundary conditions. The blood flow was assumed homogeneous and incompressible. The blood was assumed to be a Newtonian fluid. The simulations with idealized models of thoracic aorta were carried out with Finite Element Method based computer code, while the simulations with realistic models of thoracic aorta were carried out with Finite Volume Method based computer code. Simulations were carried out for four cardiac cycles. The distribution of flow, pressure and Wall Shear Stress (WSS) observed during the fourth cardiac cycle were extensively analyzed. The aim of carrying out the simulations with idealized model was to get an estimate of flow dynamics in a realistic aorta model. The motive behind the choice of three aorta models with distinct features was to understand the dependence of flow dynamics on aorta anatomy. Highly disturbed and nonuniform distribution of velocity and WSS was observed in aortic arch, near brachiocephalic, left common artery, and left subclavian artery. On the other hand, the WSS profiles at the roots of branches show significant differences with geometry variation of aorta and branches. The comparison of instantaneous WSS profiles revealed that the model with straight branching arteries had relatively lower WSS compared to that in the aorta model with curved branches. In addition to this, significant differences were observed in the spatial and temporal profiles of WSS, flow, and pressure. The study with idealized model was extended to study blood flow in thoracic aorta under the effects of hypertension and hypotension. One of the idealized aorta models was modified along with the boundary conditions to mimic the thoracic aorta under the effects of hypertension and hypotension. The results of simulations with realistic models extracted from CT scans demonstrated more realistic flow dynamics than that in the idealized models. During systole, the velocity in ascending aorta was skewed towards the outer wall of aortic arch. The flow develops secondary flow patterns as it moves downstream towards aortic arch. Unlike idealized models, the distribution of flow was nonplanar and heavily guided by the artery anatomy. Flow cavitation was observed in the aorta model which was imaged giving longer branches. This could not be properly observed in the model with imaging containing a shorter length for aortic branches. The flow circulation was also observed in the inner wall of the aortic arch. However, during the diastole, the flow profiles were almost flat and regular due the acceleration of flow at the inlet. The flow profiles were weakly turbulent during the flow reversal. The complex flow patterns caused a non-uniform distribution of WSS. High WSS was distributed at the junction of branches and aortic arch. Low WSS was distributed at the proximal part of the junction, while intermedium WSS was distributed in the distal part of the junction. The pulsatile nature of the inflow caused oscillating WSS at the branch entry region and inner curvature of aortic arch. Based on the WSS distribution in the realistic model, one of the aorta models was altered to induce artificial atherosclerotic plaque at the branch entry region and inner curvature of aortic arch. Atherosclerotic plaque causing 50% blockage of lumen was introduced in brachiocephalic artery, common carotid artery, left subclavian artery, and aortic arch. The aim of this part of the study was first to study the effect of stenosis on flow and WSS distribution, understand the effect of shape of atherosclerotic plaque on flow and WSS distribution, and finally to investigate the effect of lumen blockage severity on flow and WSS distributions. The results revealed that the distribution of WSS is significantly affected by plaque with mere 50% stenosis. The asymmetric shape of stenosis causes higher WSS in branching arteries than in the cases with symmetric plaque. The flow dynamics within thoracic aorta models has been extensively studied and reported here. The effects of pressure and arterial anatomy on the flow dynamic were investigated. The distribution of complex flow and WSS is correlated with the localization of atherosclerosis. With the available results we can conclude that the thoracic aorta, with complex anatomy is the most vulnerable artery for the localization and development of atherosclerosis. The flow dynamics and arterial anatomy play a role in the localization of atherosclerosis. The patient specific image based models can be used to diagnose the locations in the aorta vulnerable to the development of arterial diseases such as atherosclerosis.
Resumo:
The authors present two patients with solid tumours (benign Schwannoma), which were found during abdominal ultra-sonography. One of them was located adjacent to the hepatic artery, near its origin at the celiac axis. In the second case the tumor was found in the diafragm. Both of them were well limited and non-invasive (benign characteristics). The removal -for diagnosis and treatment - was done using videolaparoscopy. They emphasize the huge advantages of this new diagnostic and therapeutical modality.
Resumo:
Os autores apresentam um estudo retrospectivo de 79 pacientes portadores de distrofias abdominais acompanhadas ou não de hérnias, operados no período compreendido entre 01/06/94 a 31/12/96. A idade média foi de 46 anos. A hérnia incisional isoladamente e o abdome distrófico (em avental) foram o principal objetivo do estudo. Enfatizam a importância da dermolipectomia abdominal para a completa recuperação do paciente bem como demonstram facilitar o manuseio técnico das hérnias. A técnica da transposição peritônio-aponeurótica longitudinal bilateral (técnica de Lázaro da Silva) foi utilizada para as grandes hérnias incisionais. É uma técnica já consagrada, que consta de três planos de suturas sem superposição dos mesmos. Sua recidiva em cinco anos de seguimento tem sido em tomo de 5% segundo estudos do próprio autor. A grande vantagem técnica é que, usando o saco herniário (quanto maior e mais espesso, melhor) como fechamento e reforço do anel, evita-se o uso de prótese com todos os inconvenientes da mesma (fístulas, rejeições etc.) Uma variante desta técnica, para as hérnias com anel herniário de até 10cm, é proposta pelos autores, e consiste no fechamento do anel e reforço da sutura com o saco herniário, em jaquetão. A vantagem seria a facilidade de execução e diminuição do tempo operatório, além de evitar dissecções extensas das camadas aponeuróticas. Quando o anel herniário alcançar 10cm e existir ligeira tensão, deve-se realizar incisão relaxadora na aponeurose anterior dos retos e recobrir a superfície cruenta com o próprio saco herniário que deverá estar íntegro. Esta técnica ainda requer maior observação clínica. É feita a revisão dos resultados dos procedimentos realizados isoladamente e acompanhados com dermolipectomia abdominal: 63 pacientes (81,66%) evoluíram sem complicações, cinco recidivas (6,3%); um caso de hematoma extenso (1,26%); dois casos de abscesso de parede em operações sem dermolipectomia (2,5%); uma necrose de linha média+embolia pulmonar (1,26%); e um óbito por embolia pulmonar (1,26%).
Resumo:
Foram avaliados os resultados tardios da colocação de cálculos biliares humanos, de colesterol, na cavidade peritoneal de ratos. Constituíram-se cinco grupos: cinco ratos foram apenas laparotomizados com manuseio da cavidade; cinco foram laparotomizados e receberam um ponto com fio monofilamentar cinco zeros no sulco paracólico direito e mesentério; dez receberam cálculos que foram deixados livres na cavidade peritoneal; em dez, os clculos foram fixados no sulco paracólico direito e, finalmente, dez tiveram clculos fixados no mesentério. Os animais foram mortos após cinco meses de pós-operatório quando se observou a cavidade abdominal e foi coletado material para estudo histopatológico. Concluiu-se que os cálculos não foram absorvidos, desenvolveram uma reação peritoneal do tipo corpo estranho com formação de plastrão e foram envolvidos por tecido fibroso e células inflamatórias.
Resumo:
Trinta e cinco doentes portadores de megacólon chagásico foram operados pela técnica da retocolectomia abdominal com anastomose colorretal mecânica término-lateral durante o período de 1993 a 1997. Vinte (57,14%) doentes eram do sexo feminino e 15 (42,85%) do masculino. A idade variou de 27 a 76 anos, com média de 51 anos. A operação constou de ressecção do segmento dilatado, sepultamento do coto retal na altura da reflexão peritoneal com grampeador, dissecção do espaço retrorretal até o plano dos músculos elevadores e anastomose colorretal mecânica término-lateral posterior. Em quatro (11,42%) doentes a anastomose foi anterior. Em três (8,57%) doentes, o teste de escape da anastomose foi positivo, o que obrigou a complementação manual da sutura em dois (5,71 %) e sutura e ostomia derivativa em um (2,85%). Ocorreram sete (20,00%) complicações pós-operatórias precoces, sendo quatro consideradas relevantes (11,42%) e quatro (11,42%) complicações tardias. Houve um (2,85%) óbito por complicação clínica. Os doentes submetidos a colostomia foram reoperados para fechamento da mesma sem intercorrências. A totalidade dos doentes apresenta hábito intestinal normal. Não houve referências a alterações gênito-urinárias, nem a incontinência fecal. A anastomose foi tocada ou visibilizada em todos os pacientes examinados, durante o seguimento ambulatorial. Não houve casos de fecaloma no coto retal. Embora os resultados iniciais sejam bastante satisfatórios, é necessário maior tempo de observação para se avaliar a possibilidade de recidiva.
Resumo:
A rare case of blunt traumatic abdominal hernia is presented in which jejunal loops herniated through the abdominal wall. The patient had a serious motor vehicle accident seven years ago, while wearing the seat belt. He developed a traumatic hernia in the anterior lateral abdominal wall, which was operated, and relapsed after some months. The patient was reoperated and we observed the unattachment of the anterior lateral abdominal musculature from the ilium crest. After the hernial sac treatment, the defect was solved with the use of a polypropylene mesh. The postoperative evolution was good and four months later there were no signs of recurrence. Traumatic abdominal hernia remains a rare clinical entity, despite the increase in blunt abdominal trauma. Traumatic abdominal wall hernia falls into two general categories: small lower quadrant abdominal defects, typically the result of blunt trauma with bicycle handlebars, and larger abdominal wall defects related to motor vehicle accidents. The diagnosis may be often established by the physical examination alone. Conventional radiology and computerized tomography usefulness have been proved. In the vast majority of cases, early repair is recommended. The appropriate treatment is the reduction of the herniated bowel into the abdomen, the debridment of nonviable tissues, and a primary tension free closure of the detect.