974 resultados para Abdominal Aortic Aneurism


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim was to propose a strategy for finding reasonable compromises between image noise and dose as a function of patient weight. Weighted CT dose index (CTDI(w)) was measured on a multidetector-row CT unit using CTDI test objects of 16, 24 and 32 cm in diameter at 80, 100, 120 and 140 kV. These test objects were then scanned in helical mode using a wide range of tube currents and voltages with a reconstructed slice thickness of 5 mm. For each set of acquisition parameter image noise was measured and the Rose model observer was used to test two strategies for proposing a reasonable compromise between dose and low-contrast detection performance: (1) the use of a unique noise level for all test object diameters, and (2) the use of a unique dose efficacy level defined as the noise reduction per unit dose. Published data were used to define four weight classes and an acquisition protocol was proposed for each class. The protocols have been applied in clinical routine for more than one year. CTDI(vol) values of 6.7, 9.4, 15.9 and 24.5 mGy were proposed for the following weight classes: 2.5-5, 5-15, 15-30 and 30-50 kg with image noise levels in the range of 10-15 HU. The proposed method allows patient dose and image noise to be controlled in such a way that dose reduction does not impair the detection of low-contrast lesions. The proposed values correspond to high- quality images and can be reduced if only high-contrast organs are assessed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Standard surgical aortic valve replacement with a biological prosthesis remains the treatment of choice for low- and mid-risk elderly patients (traditionally >65 years of age) suffering from severe symptomatic aortic valve stenosis or insufficiency, and for young patients with formal contraindications to long-lasting anticoagulation. Unfortunately, despite the fact that several technical improvements have noticeably improved the resistance of pericardial and bovine bioprostheses to leaflet calcifications and ruptures, the risk of early valve failure with rapid degeneration still exists, especially for patients under haemodialysis and for patients <60 years of age at the time of surgery. Until now, redo open heart surgery under cardiopulmonary bypass and on cardioplegic arrest was the only available therapeutic option in case of bioprosthesis degeneration, but it carried a higher surgical risk when elderly patients with severe concomitant comorbidities were concerned. Since a few years, the advent of new transcatheter aortic valve procedures has opened new horizons in cardiac surgery and, in particular, the possibility of implanting stented valves within the degenerated stented bioprosthesis, the so-called 'valve-in-valve' (VinV) concept, has become a clinical practice in experienced cardiac centres. The VinV procedure represents a minimally invasive approach dedicated to high-risk redo patients, and published preliminary reports have shown a success rate of 100% with absence of significant valvular leaks, acceptable transvalvular gradients and low complication rate. However, this procedure is not riskless and the most important concerns are about the size mismatch and the right positioning within the degenerated bioprosthesis. In this article, we review the limited available literature about VinV procedures, underline important technical details for the positioning and provide guidelines to prevent valve-prosthesis mismatch comparing the three sizes of the only commercially available transapical device, the Edwards Sapien, with the inner diameter of three of the most commonly used stented bioprostheses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Purpose: To test the hypothesis that simultaneous closure of at least 2 independent vascular territories supplying the spinal cord and/or prolonged hypotension may be associated with symptomatic spinal cord ischemia (SCI) after thoracic endovascular aortic repair (TEVAR). Methods: A pattern matching algorithm was used to develop a risk model for symptomatic SCI using a prospective 63-patient single-center cohort to test the positive predictive value (PPV) of prolonged intraoperative hypotension and/or simultaneous closure of at least 2 of 4 the vascular territories supplying the spinal cord (left subclavian, intercostal, lumbar, and hypogastric arteries). This risk model was then applied to data extracted from the multicenter European Registry on Endovascular Aortic Repair Complications (EuREC). Between 2002 and 2010, the 19 centers participating in EuREC reported 38 (1.7%) cases of symptomatic spinal cord ischemia among the 2235 patients in the database. Results: In the single-center cohort, direct correlations were seen between the occurrence of symptomatic SCI and both prolonged intraoperative hypotension (PPV 1.00, 95% CI 0.22 to 1.00, p = 0.04) and simultaneous closure of at least 2 independent spinal cord vascular territories (PPV 0.67, 95% CI 0.24 to 0.91, p = 0.005). Previous closure of a single vascular territory was not associated with an increased risk of symptomatic spinal cord ischemia (PPV 0.07, 95% CI 0.01 to 0.16, p = 0.56). The combination of prolonged hypotension and simultaneous closure of at least 2 territories exhibited the strongest association (PPV 0.75, 95% CI 0.38 to 0.75, p<0.0001). Applying the model to the entire EuREC cohort found an almost perfect agreement between the predicted and observed risk factors (kappa 0.77, 95% CI 0.65 to 0.90). Conclusion: Extensive coverage of intercostal arteries alone by a thoracic stent-graft is not associated with symptomatic SCI; however, simultaneous closure of at least 2 vascular territories supplying the spinal cord is highly relevant, especially in combination with prolonged intraoperative hypotension. As such, these results further emphasize the need to preserve the left subclavian artery during TEVAR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcatheter aortic valve therapies are the newest established techniques for the treatment of high risk patients affected by severe symptomatic aortic valve stenosis. The transapical approach requires a left anterolateral mini-thoracotomy, whereas the transfemoral method requires an adequate peripheral vascular access and can be performed fully percutaneously. Alternatively, the trans-subclavian access has been recently proposed as a third promising approach. Depending on the technique, the fine stent-valve positioning can be performed with or without contrast injections. The transapical echo-guided stent-valve implantation without angiography (the Lausanne technique) relies entirely on transoesophageal echocardiogramme imaging for the fine stent-valve positioning and it has been proved that this technique prevents the onset of postoperative contrast-related acute kidney failure. Recent published reports have shown good hospital outcomes and short-term results after transcatheter aortic valve implantation, but there are no proven advantages in using the transfemoral or the transapical technique. In particular, the transapical series have a higher mean logistic Euroscore of 27-35%, a procedural success rate above 95% and a mean 30-day mortality between 7.5 and 17.5%, whereas the transfemoral results show a lower logistic Euroscore of 23-25.5%, a procedural success rate above 90% and a 30-day mortality of 7-10.8%. Nevertheless, further clinical trials and long-term results are mandatory to confirm this positive trend. Future perspectives in transcatheter aortic valve therapies would be the development of intravascular devices for the ablation of the diseased valve leaflets and the launch of new stent-valves with improved haemodynamic, different sizes and smaller delivery systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aortic access problems due to diseased or small peripheral vessels are a major issue in endovascular aneurysm repair (EVAR). In the emergency setting, like aortic rupture after blunt trauma, or in patients with a hostile abdomen, a more proximal access to the aorta is not a pleasant perspective. We developed in situ introducer sheath dilatation as a bail-out technique for patients with difficult aortic access under various circumstances including EVAR, intra-aortic balloon pump insertion and cannulation for perfusion. The method described allows to increase the access vessel diameter by 50% (from 6 to 9 mm) or the luminal circumference from 18 to 27 F. We have used this technique in five patients without complication, very much in contrast to the traditionally practiced 'forced device insertion'.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Transcatheter aortic valve implantations (TAVI) are indicated in high risk patients requiring aortic valve replacement (AVR). However, CT-scans, coronary angiograms and intraoperative aortographies can induce contrast-related nephro-toxicity with a concrete risk of acute postoperative renal failure, especially in severely diseased patients. To prevent this complication, we routinely perform transapical (TA) TAVI guided by transesophageal echocardiogram and fluoroscopy without angiography. Material and Methods: From November 2008 to December 2009, 31 high-risk patients suffering from severe symptomatic aortic stenosis underwent TA-TAVI in our institution. The preoperative imaging assessment (cardiac CT-scan and coronary angiogram) was performed no less than 10 days before the TA-TAVI in all patients (to recover the renal function) with a low-dose protocol for injected contrast medium (equivalent to the patient's weight for the CT-scan). During the TA-TAVI, the stent-valve positioning was performed without any contrast injection. Results: 32 consecutive stent-valve were successfully positioned in 31 patients (mean age 80.76 8 8.3 years; mean EuroSCORE: 32.2 8 12.9%) through a transapical access (1 patient required 2 valves for valve embolisation). The mean preoperative creatinine and urea blood levels were 102.6 8 67.7 _ g/dl (range 53-339 _ g/dl) and 8.45 8 4.9 mmol/l, respectively. A chronic renal insufficiency affected 12 patients (38.7%) with 1 patient in pre-dialysis. Postoperatively, no patient developed acute myocardial infarction, atrio-ventricular block or acute renal insufficiency (mean creatinine level: 89.7 8 64.55 _ g/dl; urea level: 7.11 8 3.47 mmol/l) and the 30-days mortality was 9.67% (3 patients). Conclusion: Specific preoperative and intraoperative protocols that require lowdoses or absence of contrast medium are useful to preserve the renal function in high risk patients operated for TAVI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complicated acute appendicitis is still associated with an increased morbidity. If laparoscopy has been accepted as a valid approach, some questions remain concerning intra-abdominal abscess formation. Routine prophylactic drainage of the abdomen has been proposed. However, this practice remains a matter of debate, poorly validated in the literature. With the present study, we investigated the impact of drainage in laparoscopic appendectomy for complicated appendicitis. This is a case match study of consecutive patients operated on by laparoscopy in a single institution. One hundred and thirty patients operated for complicated appendicitis (local peritonitis without perforation, with perforation, or with periappendicular abscess) with prophylactic intraperitoneal drainage were matched one by one to 130 patients operated without drainage. Uncomplicated appendicitis and generalized peritonitis were excluded. Primary endpoint was surgical complications and secondary endpoints were transit recovery time and length of hospital stay. Patients without drain had significantly less overall complications (7.7% vs. 18.5%, p = 0.01). Moreover, the absence of drainage was of significant benefit for transit recovery time (2.5 vs. 3.5 days, p = 0.0068) and length of hospital stay (4.2 vs. 7.3 days, p < 0.0001). No benefits were observed for prophylactic drainage of the abdominal cavity during emergency laparoscopic treatment of complicated appendicitis. For this reason, this practice may be abandoned.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adequate in-vitro training in valved stents deployment as well as testing of the latter devices requires compliant real-size models of the human aortic root. The casting methods utilized up to now are multi-step, time consuming and complicated. We pursued a goal of building a flexible 3D model in a single-step procedure. We created a precise 3D CAD model of a human aortic root using previously published anatomical and geometrical data and printed it using a novel rapid prototyping system developed by the Fab@Home project. As a material for 3D fabrication we used common house-hold silicone and afterwards dip-coated several models with dispersion silicone one or two times. To assess the production precision we compared the size of the final product with the CAD model. Compliance of the models was measured and compared with native porcine aortic root. Total fabrication time was 3 h and 20 min. Dip-coating one or two times with dispersion silicone if applied took one or two extra days, respectively. The error in dimensions of non-coated aortic root model compared to the CAD design was <3.0% along X, Y-axes and 4.1% along Z-axis. Compliance of a non-coated model as judged by the changes of radius values in the radial direction by 16.39% is significantly different (P<0.001) from native aortic tissue--23.54% at the pressure of 80-100 mmHg. Rapid prototyping of compliant, life-size anatomical models with the Fab@Home 3D printer is feasible--it is very quick compared to previous casting methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the outcome and patterns of failure in patients with testicular lymphoma treated by chemotherapy (CT) and/or radiation therapy (RT). METHODS AND MATERIALS: Data from a series of 36 adult patients with Ann Arbor Stage I (n = 21), II (n = 9), III (n = 3), or IV (n = 3) primary testicular lymphoma, consecutively treated between 1980 and 1999, were collected in a retrospective multicenter study by the Rare Cancer Network. Median age was 64 years (range: 21-91 years). Full staging workup (chest X-ray, testicular ultrasound, abdominal ultrasound, and/or thoracoabdominal computer tomography, bone marrow assessment, full blood count, lactate dehydrogenase, and cerebrospinal fluid evaluation) was completed in 18 (50%) patients. All but one patient underwent orchidectomy, and spermatic cord infiltration was found in 9 patients. Most patients (n = 29) had CT, consisting in most cases of cyclophosphamide, doxorubicin, vincristine, and prednisolone (CHOP) with (n = 17) or without intrathecal CT. External RT was delivered to scrotum alone (n = 12) or testicular, iliac, and para-aortic regions (n = 8). The median RT dose was 31 Gy (range: 20-44 Gy) in a median of 17 fractions (10-24), using a median of 1.8 Gy (range: 1.5-2.5 Gy) per fraction. The median follow-up period was 42 months (range: 6-138 months). RESULTS: After a median period of 11 months (range: 1-76 months), 14 patients presented lymphoma progression, mostly in the central nervous system (CNS) (n = 8). Among the 17 patients who received intrathecal CT, 4 had a CNS relapse (p = NS). No testicular, iliac, or para-aortic relapse was observed in patients receiving RT to these regions. The 5-year overall, lymphoma-specific, and disease-free survival was 47%, 66%, and 43%, respectively. In univariate analyses, statistically significant factors favorably influencing the outcome were early-stage and combined modality treatment. Neither RT technique nor total dose influenced the outcome. Multivariate analysis revealed that the most favorable independent factors predicting the outcome were younger age, early-stage disease, and combined modality treatment. CONCLUSIONS: In this multicenter retrospective study, CNS was found to be the principal site of relapse, and no extra-CNS lymphoma progression was observed in the irradiated volumes. More effective CNS prophylaxis, including combined modalities, should be prospectively explored in this uncommon site of extranodal lymphoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urgent reoperative transapical aortic valve-in-valve has never been proposed as a treatment option in case of a failed transcatheter aortic valve implantation (TAVI) or in case of worsening of an existing paravalvular leak, if this complication occurs right after, or a few days after, the primary transapical aortic valve implantation. Experienced surgeons should argue that after a transapical TAVI, the apex is damaged and fragile, with a high risk of irreparable ventricular tears and life-threatening bleeding if a second transapical procedure is scheduled during the acute phase. Nevertheless, if the patient is inoperable and the vascular status, including the ascending aorta, limits alternative accesses, the urgent reoperative transapical valve-in-valve becomes an alternative. We illustrate, for the first time ever, our experience with an 81-year old female patient who underwent a transapical (TA) TAVI with a Sapien? XT 23 mm. The day after the procedure, the patient haemodynamically worsened in combination with a worsening of a known (grade 1-2) paravalvular leak. Thus, on postoperative day two, an urgent transapical valve-in-valve was performed, and a second Sapien? XT 23 mm was placed, with an excellent haemodynamic result and absence of leak. The redo apical access did not appear very complicated and the postoperative recovery was uneventful.