840 resultados para 4D Dosimetry


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The compound [Pd(dmba)(NCO)(imz)] (dmba = N,N-dimethylbenzilamine; NCO = cyanate; imz = imidazole) was studied through experimental and theoretical methods. The complex was synthesized and characterized by IR and NMR spectroscopy. To an appropriate representation of the molecular environment, Gaussian basis sets for the constituent atoms of the compound were built and, after adequate supplementation with polarization and diffuse functions, they were used to study the molecule. Calculations of electronic and vibrational structure of two possible isomers were carried out, showing that the compound, which contains the NCO GROUP trans to the Pd-C bond, is 4.29 kcal/mol more stable than the analogous one, where the imz ligand is trans to the Pd-C bond. The calculated molecular parameters, bond distances, and bond angles showed that the geometry around the metallic center is square-planar with the cyanate being linear. The theoretical infrared spectrum of C(1) symmetry (electronic state (1)A) is in accordance with the experimental one. It also verified the contribution of Pd (4d(xz) + 4d(yz)) and Pd (4d(xy)) in the HOMO and LUMO orbitals, respectively. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

SrMoO4 doped with rare earth are still scarce nowadays and have attracted great attention due to their applications as scintillating materials in electro-optical like solid-state lasers and optical fibers, for instance. In this work Sr1-xEuxMoO4 powders, where x = 0.01; 0.03 and 0.05, were synthesized by Complex Polymerization (CP) Method. The structural and optical properties of the SrMoO4:Eu3+ were analyzed by powder X-ray diffraction patterns, Fourier Transform Infra-Red (FTIR), Raman Spectroscopy, and through Photoluminescent Measurements (PL). Only a crystalline scheelite-type phase was obtained when the powders were heat-treated at 800 A degrees C for 2 h, 2 theta = 27.8A degrees (100% peak). The excitation spectra of the SrMoO4:Eu3+ (lambda(Em.) = 614 nm) presented the characteristic band of the Eu3 + 5L6 transition at 394 nm and a broad band at around 288 nm ascribed to the charge-transfer from the O (2p) state to the Mo (4d) one in the SrMoO4 matrix. The emission spectra of the SrMoO4:Eu3+ powders (lambda(Exc.) = 394 and 288 nm) show the group of sharp emission bands among 523-554 nm and 578-699 nm, assigned to the D-5(1)-> F-7(0,1and 2) and D-5(0)-> F-7(0,1,2,3 and 4), respectively. The band related to the D-5(0)-> F-7(0) transition indicates the presence of Eu3+ site without inversion center. This hypothesis is strengthened by the fact that the band referent to the D-5(0)-> F-7(2) transition is the most intense in the emission spectra.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Southwest region of the Bahia state in Brazil hosts the largest uranium reserve of the country (100 kton in uranium, only), plus the cities of Caetite, Lagoa Real and Igapora. In this work, aim was at the investigation of uranium burdens on residents of these cities by using teeth as bioindicators, as a contribution for possible radiation protection measures. Thus, a total of 41 human teeth were collected, plus 50 from an allegedly uranium free area (the control region). Concentrations of uranium in teeth from residents of 5- to 87-y old were determined by means of a high-resolution inductively coupled plasma mass spectrometer (ICP-MS). The highest uranium concentration in teeth was measured from samples belonging to residents of Caetite (median equal to 16 ppb). Assuming that the uranium concentrations in teeth and bones are similar within 10-20% (for children and young adults), it concluded that uranium body levels in residents of Caetite are at least one order of magnitude higher than the worldwide average. This finding led to conclude that daily ingestion of uranium, from food and water, is equally high.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thin uranium films built on muscovite mica basis and obsidian samples having known ages were irradiated with thermal neutrons at the IPEN/CNEN reactor, São Paulo. Comparing thin film performance with the obsidian one, it was observed that the latter feel a greater neutron fluence. Nominal fluences at the used facility are in agreement with the results obtained analysing the obsidian samples. A probable hypothesis to explain this disagreement, namely, the uranium loss from the thin films, was ruled out. © 1995.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Temporal and spatial acoustic intensity (SATA) of therapeutic ultrasound (US) equipment should be monitored periodically. In order to evaluate the conditions of US equipment in use in the city of Piracicaba-Sao Paulo, Brazil, 31 machines - representing all Brazilian manufacturers - were analysed under continuous and pulsed conditions at a frequency of 1 MHz. Data about temporal and spatial acoustic intensity were collected and the use of equipment was surveyed. Intensities of 0.1, 0.2, 0.5, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0 Wcm -2, indicated on the equipment panel were analysed using a previously calibrated digital radiation pressure scale, model UPM-DT-1 (Ohmic Instruments Co). The acoustic intensity (I) results were expressed as superior and inferior quartile ranges for transducers with metal surfaces of 9 cm 2 and an effective radiation area (ERA) Of 4 cm 2. The results under continuous conditions were: I 0.1 = -20.0% and -96%. I 0.2 = -3.1% and -83.7%. I 0.5 = -35.0% and -86.5%. I 0.8 = -37.5% and -71.0%. I 2.5 = -49.0% and -69.5%. I 3.0 = -58.1% and -77.6%. For pulsed conditions, intensities were: I 0.1 = -40.0% and -86.2%. I 1.0 = -50.0% and -86.5%. I 1.5 = -62.5% and -82.5%. I 2.0 = -62.5% and -81.6%. I 2.5 = -64.7% and -88.8%. I 3.0 = -87.1% and -94.8%. In reply to the questionnaire drawn up to check the conditions of use of equipment, all users reported the use of hydrosoluble gel as a coupling medium and none had carried out previous calibrations. Most users used intensities in the range of 0.4. to 1.0 Wcm -2 and used machines for 300 to 400 minutes per week. The majority of machines had been bought during the previous seven years and weekly use ranged from less than 100 minutes to 700 minutes (11 hours 40 minutes). Findings confirm previous observations of discrepancy between the intensity indicated on the equipment panel and that emitted by the transducer and highlight the necessity for periodic evaluations of US equipment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The TL, optical absorption (OA) and EPR properties of natural Brazilian alexandrite and chrysoberyl have been investigated. The TL measurements for natural alexandrite show five peaks between 100 and 450°C, with their emission spectrum having 370 and/or 570 nm components. The intensity of the 320°C TL peak was found to be enhanced with pre-annealing treatment, more prominently above 600°C. The OA and EPR measurements showed that this kind of heat treatment induces the Fe2→ Fe3+ conversion in the natural sample. Chrysoberyl samples exhibited the TL peaks at the same temperatures as alexandrite samples, but the glow curves were more than 200 times less intense than alexandrite ones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tissue repair is an integration of dynamic interactive processes that involves soluble mediators, blood components, production of extra-cellular matrix and mesenchymal cells. Many studies involving the use of LLLT shows that the healing process is favored by such therapy. The aim of this work was to evaluate, through histological analysis, the tissue effects of cutaneous wounds submitted to different intensities and a same irradiation dose with lasers in λ670 or λ685nm. Eighteen animals were divided in two experimental groups according to wavelength used (λ670 or λ685nm). Each one of these groups was divided still in three subgroups of three animals each, related to the intensity of applied irradiation (2, 15 or 25mW). Twelve animals acted as untreated controls and were not irradiated. The irradiation was carried out during seven days. The animals were sacrificed eight days after surgery. The specimens were removed, kept in 4% formaldehyde for 24 hours, routinely prepared to wax, stained with H&E and analyzed under light microscopy. The histological characteristics observed, so much in the irradiated animals, as in the control, they are indicative of a substitution repair process, however, the LLLT modulatory positive effect was observed, in the healing process, mainly associate to the use of the shorter wavelength and low power. The results of the present study indicate that LLLT improves cutaneous wound repair and best results are achieved when higher potencies associated to short wavelengths or lower potencies associated to higher wavelengths are used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A major challenge in cancer radiotherapy is to deliver a lethal dose of radiation to the target volume while minimizing damage to the surrounding normal tissue. We have proposed a model on how treatment efficacy might be improved by interfering with biological responses to DNA damage using exogenous electric fields as a strategy to drastically reduce radiation doses in cancer therapy. This approach is demonstrated at this Laboratory through case studies with prokaryotes (bacteria) and eukaryotes (yeast) cells, in which cellkilling rates induced by both gamma radiation and exogenous electric fields were measured. It was found that when cells exposed to gamma radiation are immediately submitted to a weak electric field, cell death increases more than an order of magnitude compared to the effect of radiation alone. This finding suggests, although does not prove, that DNA damage sites are reached and recognized by means of long-range electric DNA-protein interaction, and that exogenous electric fields could destructively interfere with this process. As a consequence, DNA repair is avoided leading to massive cell death. Here we are proposing the use this new technique for the design and construction of novel radiotherapy facilities associated with linac generated gamma beams under controlled conditions of dose and beam intensity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A microcontrolled instrument for measuring the energy fluence rate (or intensity) of X-ray pulses in the orthovoltage range of 120 to 300 kV is described. The prototype instrument consists of a pyroelectric sensor, a low-noise highsensitivity current-to-voltage converter, a microcontroller and a digital display. The response of the instrument is nonlinear with the intensity of the radiation. The precision is better than 3%. The equipment is inexpensive, rugged, simple to construct and has good long-term stability. © 2009 Springer-Verlag.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims the evaluation of the radiation dose levels involved in veterinary radiology and to contribute to review the procedures for performing radiographic exams in animals in the Department of Veterinary Radiology of Faculdade de Medicina Veterinária e Zootecnia of Universidade Estadual Paulista (FMVZ-UNESP/Brazil). The obtained results has shown to be extremely important the assessment of doses involved in veterinary diagnostic radiology procedures both to protect the occupationally exposed workers and to optimize the delivered doses to the animals. © 2009 Springer-Verlag.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An upconversion random laser (RL) operating in the ultraviolet is reported for Nd 3+ doped fluoroindate glass powder pumped at 575 nm. The RL is obtained by the resonant excitation of the Nd 3+ state 2G 7/2 followed by energy transfer among two excited ions such that one ion in the pair decays to a lower energy state and the other is promoted to state 4D 7/2 from where it decays emitting light at 381 nm. The RL threshold of 30 kW/cm 2 was determined by monitoring the photoluminescence intensity as a function of the pump laser intensity. The RL pulses have time duration of 29 ns that is 50 times smaller than the decay time of the upconversion signal when the sample is pumped with intensities below the RL laser threshold. © 2011 Optical Society of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We study the local properties of a class of codimension-2 defects of the 6d N = (2, 0) theories of type J = A, D, E labeled by nilpotent orbits of a Lie algebra $g, where g is determined by J and the outer-automorphism twist around the defect. This class is a natural generalization of the defects of the six-dimensional (6d) theory of type SU(N) labeled by a Young diagram with N boxes. For any of these defects, we determine its contribution to the dimension of the Higgs branch, to the Coulomb branch operators and their scaling dimensions, to the four-dimensional (4d) central charges a and c and to the flavor central charge k. © 2013 World Scientific Publishing Company.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By means of a triple master action we deduce here a linearized version of the new massive gravity (NMG) in arbitrary dimensions. The theory contains a 4th-order and a 2nd-order term in derivatives. The 4th-order term is invariant under a generalized Weyl symmetry. The action is formulated in terms of a traceless ημνΩμνρ=0 mixed symmetry tensor Ωμνρ=-Ωμρν and corresponds to the massive Fierz-Pauli action with the replacement e μν=∂ρΩμνρ. The linearized 3D and 4D NMG theories are recovered via the invertible maps Ωμνρ=Ïμνρβhβμ and Ωμνρ=ÏμνργδT [γδ]μ respectively. The properties h μν=hνμ and T[[γδ]μ]= 0 follow from the traceless restriction. The equations of motion of the linearized NMG theory can be written as zero curvature conditions ∂νTρμ-∂ρT νμ=0 in arbitrary dimensions. © 2013 American Physical Society.