992 resultados para 3-color detector


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To quantify the interobserver variability of abdominal aortic aneurysm (AAA) neck length and angulation measurements. MATERIALS AND METHODS: A total of 25 consecutive patients scheduled for endovascular AAA repair underwent follow-up 64-row computed tomographic (CT) angiography in 0.625-mm collimation. AAA neck length and angulation were determined by four blinded, independent readers. AAA neck length was defined as the longitudinal distance between the first transverse CT slice directly distal to the lowermost renal artery and the first transverse CT slice that showed at least a 15% larger outer aortic wall diameter versus the diameter measured directly below the lowermost renal artery. Infrarenal AAA neck angulation was defined as the true angle between the longitudinal axis of the proximal AAA neck and the longitudinal axis of the AAA lumen as analyzed on three-dimensional CT reconstructions. RESULTS: Mean deviation in aortic neck length determination was 32.3% and that in aortic neck angulation was 32.1%. Interobserver variability of aortic neck length and angulation measurements was considerable: in any reader combination, at least one measurement difference was outside the predefined limits of agreement. CONCLUSIONS: Assessment of the longitudinal extension and angulation of the infrarenal aortic neck is associated with substantial observer variability, even if measurement is carried out according to a standardized protocol. Further studies are mandatory to assess dedicated technical approaches to minimize variance in the determination of the longitudinal extension and angulation of the infrarenal aortic neck.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: This retrospective study was conducted to determine whether a low-volume contrast medium protocol provides sufficient enhancement for 64-detector computed tomography angiography (CTA) in patients with aortoiliac aneurysms. METHODS: Evaluated were 45 consecutive patients (6 women; mean age, 72 +/- 6 years) who were referred for aortoiliac computed tomography angiography between October 2005 and January 2007. Group A (22 patients; creatinine clearance, 64.2 +/- 8.1 mL/min) received 50 mL of the contrast agent. Group B (23 patients; creatinine clearance, 89.4 +/- 7.3 mL/min) received 100 mL of the contrast agent. The injection rate was 3.5 mL/s, followed by 30 mL of saline at 3.5 mL/s. Studies were performed on the same 64-detector computed tomography scanner using a real-time bolus-tracking technique. Quantitative analysis was performed by determination of mean vascular attenuation at 10 regions of interest from the suprarenal aorta to the common femoral artery by one reader blinded to type and amount of contrast agent and compared using the Student t test. Image quality according to a 4-point scale was assessed in consensus by two readers blinded to type and amount of contrast medium and compared using the Mann-Whitney test. Multivariable adjustments were performed using ordinal regression analysis. RESULTS: Mean total attenuation did not differ significantly between both groups (196.5 +/- 33.0 Hounsfield unit [HU] in group A and 203.1 +/- 44.2 HU in group B; P = .57 by univariate and P > .05 by multivariable analysis). Accordingly, attenuation at each region of interest was not significantly different (P > .35). Image quality was excellent or good in all patients. No significant differences in visual assessment were found comparing both contrast medium protocols (P > .05 by univariate and by multivariable analysis). CONCLUSIONS: Aortoiliac aneurysm imaging can be performed with substantially reduced amounts of contrast medium using 64-detector computed tomography angiography technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To determine if multi–detector row computed tomography (CT) can replace conventional radiography and be performed alone in severe trauma patients for the depiction of thoracolumbar spine fractures. MATERIALS AND METHODS: One hundred consecutive severe trauma patients who underwent conventional radiography of the thoracolumbar spine as well as thoracoabdominal multi–detector row CT were prospectively identified. Conventional radiographs were reviewed independently by three radiologists and two orthopedic surgeons; CT images were reviewed by three radiologists. Reviewers were blinded both to one another’s reviews and to the results of initial evaluation. Presence, location, and stability of fractures, as well as quality of reviewed images, were assessed. Statistical analysis was performed to determine sensitivity and interobserver agreement for each procedure, with results of clinical and radiologic follow-up as the standard of reference. The time to perform each examination and the radiation dose involved were evaluated. A resource cost analysis was performed. RESULTS: Sixty-seven fractured vertebrae were diagnosed in 26 patients. Twelve patients had unstable spine fractures. Mean sensitivity and interobserver agreement, respectively, for detection of unstable fractures were 97.2% and 0.951 for multi–detector row CT and 33.3% and 0.368 for conventional radiography. The median times to perform a conventional radiographic and a multi–detector row CT examination, respectively, were 33 and 40 minutes. Effective radiation doses at conventional radiography of the spine and thoracoabdominal multi–detector row CT, respectively, were 6.36 mSv and 19.42 mSv. Multi–detector row CT enabled identification of 146 associated traumatic lesions. The costs of conventional radiography and multi–detector row CT, respectively, were $145 and $880 per patient. CONCLUSION: Multi–detector row CT is a better examination for depicting spine fractures than conventional radiography. It can replace conventional radiography and be performed alone in patients who have sustained severe trauma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Species that exhibit genetic color polymorphism are suitable for studying the evolutionary forces that maintain heritable phenotypic variation in nature. Male color morphs often differ in behavioral dominance, affecting the evolution of color polymorphisms. However, behavioral dominance among female color morphs has received far less attention. We studied a polymorphic population of the cichlid fish Neochromis omnicaeruleus from Lake Victoria, in which 3 distinct female color morphs coexist, black-and-white blotched (WB), orange blotched (OB), and plain (P) color morphs. First, we investigated dominance relationships among female morphs using triadic and dyadic encounters in the laboratory. In triadic encounters, both WB and OB females dominated plain, whereas WB females dominated OB females. Dominance of WB over OB was confirmed using dyadic encounters. In a second experiment, blotched (WB or OB) and plain full-sib sisters were bred by crossing a blotched and a plain parent. In dyadic encounters, WB female morphs dominated their plain sisters, suggesting that dominance of WB females is a pleiotropic effect of color or that genes coding for color and those influencing behavioral dominance are genetically linked, explaining the association between color and behavioral dominance despite gene flow. We conclude that behavioral dominance asymmetries exist among female color morphs of the fish N. omnicaeruleus, and discuss possible mechanisms that may account for the tight association between color and behavioral dominance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

White corn was compared with yellow corn in a 180-day finishing trial with 600 lb. Angus steers fed 90% concentrate diets. Steers fed yellow corn consumed 3.3% less feed and were 3.8% more efficient in feed utilization. Rate of gain and carcass characteristics were similar for steers fed white or yellow corn. The color of subcutaneous fat over the ribs was significantly whiter from carcasses of steers fed white corn compared with those fed yellow corn. The results of this study indicate that white corn may be used instead of barley to produce whiter fat in beef carcasses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ISU ADVANCE has become Iowa State’s most prominent vehicle to recruit, retain, and advance women and women of color in STEM faculty positions. We are known for a well managed network, innovative research, and an integrated approach to change. We work within departments using a Collaborative Transformation approach to improve the work environment for all faculty members. Our program identifies cultures, practices, and structures that enhance or hinder the careers of ISU faculty, and works with faculty and administrators to transform university policies, practices, and academic culture in pursuit of a diverse and vibrant faculty in STEM disciplines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ce volume recueille les actes du colloque qui sest tenu le 16 mars 2007 à lInstitut suisse de droit comparé (Lausanne) à loccasion de la 19e Journée de droit international privé. Le processus de révision de la Convention de Lugano, instrument dimportance centrale dans le contentieux international impliquant la Suisse, aura duré plus de dix ans. La signature de la Convention révisée est intervenue, pour le compte de la Suisse, le 30 octobre 2007. Le texte a subi un remodelage à laune du droit européen, tout en consacrant sans bouleversement majeur les acquis de la jurisprudence. Limportance de cet événement a incité une dizaine dexperts suisses et étrangers, spécialistes chevronnés et jeunes chercheurs à faire le point sur les quelques innovations du texte ainsi quà rappeler les solutions originelles qui ont résisté au temps.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We re-analyze the signal of non-planetary energetic neutral atoms (ENAs) in the 0.4-5.0 keV range measured with the Neutral Particle Detector (NPD) of the ASPERA-3 and ASPERA-4 experiments on board the Mars and Venus Express satellites. Due to improved knowledge of sensor characteristics and exclusion of data sets affected by instrument effects, the typical intensity of the ENA signal obtained by ASPERA-3 is an order of magnitude lower than in earlier reports. The ENA intensities measured with ASPERA-3 and ASPERA-4 now agree with each other. In the present analysis, we also correct the ENA signal for Compton-Getting and for ionization loss processes under the assumption of a heliospheric origin. We find spectral shapes and intensities consistent with those measured by the Interstellar Boundary Explorer (IBEX). The principal advantage of ASPERA with respect to the IBEX sensors is the two times better spectral resolution. In this study, we discuss the physical significance of the spectral shapes and their potential variation across the sky. At present, these observations are the only independent test of the heliospheric ENA signal measured with IBEX in this energy range. The ASPERA measurements also allow us to check for a temporal variation of the heliospheric signal as they were obtained between 2003 and 2007, whereas IBEX has been operational since the end of 2008.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A critical step for speciation in the face of gene flow is the origination of reproductive isolation. The evolution of assortative mating greatly facilitates this process. Assortative mating can be mediated by one or multiple cues across an array of sensory modalities. We here explore possible cues that may underlie female mate choice in a sympatric species pair of cichlid fish from Lake Victoria, Pundamilia pundamilia and Pundamilia nyererei. Previous studies identified species-specific female preferences for male coloration, but effects of other cues could not be ruled out. Therefore, we assessed female choice in a series of experiments in which we manipulated visual (color) and chemical cues. We show that the visibility of differences in nuptial hue (i.e., either blue or red) between males of the 2 species is necessary and sufficient for assortative mating by female mate choice. Such assortment mediated by a single cue may evolve relatively quickly, but could make reproductive isolation vulnerable to environmental changes. These findings confirm the important role of female mate choice for male nuptial hue in promoting the explosive speciation of African haplochromine cichlids.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Computed tomography (CT) accounts for more than half of the total radiation exposure from medical procedures, which makes dose reduction in CT an effective means of reducing radiation exposure. We analysed the dose reduction that can be achieved with a new CT scanner [Somatom Edge (E)] that incorporates new developments in hardware (detector) and software (iterative reconstruction). METHODS We compared weighted volume CT dose index (CTDIvol) and dose length product (DLP) values of 25 consecutive patients studied with non-enhanced standard brain CT with the new scanner and with two previous models each, a 64-slice 64-row multi-detector CT (MDCT) scanner with 64 rows (S64) and a 16-slice 16-row MDCT scanner with 16 rows (S16). We analysed signal-to-noise and contrast-to-noise ratios in images from the three scanners and performed a quality rating by three neuroradiologists to analyse whether dose reduction techniques still yield sufficient diagnostic quality. RESULTS CTDIVol of scanner E was 41.5 and 36.4 % less than the values of scanners S16 and S64, respectively; the DLP values were 40 and 38.3 % less. All differences were statistically significant (p < 0.0001). Signal-to-noise and contrast-to-noise ratios were best in S64; these differences also reached statistical significance. Image analysis, however, showed "non-inferiority" of scanner E regarding image quality. CONCLUSIONS The first experience with the new scanner shows that new dose reduction techniques allow for up to 40 % dose reduction while still maintaining image quality at a diagnostically usable level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurements are presented of production properties and couplings of the recently discovered Higgs boson using the decays into boson pairs, H --> gamma-gamma, H --> ZZ* --> 4 leptons and H --> WW --> 2 leptons + 2 neutrinos. The results are based on the complete pp collision data sample recorded by the ATLAS experiment at the CERN Large Hadron Collider at centre-of-mass energies of 7 TeV and 8 TeV, corresponding to an integrated luminosity of about 25/fb. Evidence for Higgs boson production through vector-boson fusion is reported. Results of combined fits probing Higgs boson couplings to fermions and bosons, as well as anomalous contributions to loop-induced production and decay modes, are presented. All measurements are consistent with expectations for the Standard Model Higgs boson.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The dynamics of isolated-photon plus jet production in pp collisions at a centre-of-mass energy of 7 TeV has been studied with the ATLAS detector at the LHC using an integrated luminosity of 37 pb^-^1. Measurements of isolated-photon plus jet bin-averaged cross sections are presented as functions of photon transverse energy, jet transverse momentum and jet rapidity. In addition, the bin-averaged cross sections as functions of the difference between the azimuthal angles of the photon and the jet, the photon-jet invariant mass and the scattering angle in the photon-jet centre-of-mass frame have been measured. Next-to-leading-order QCD calculations are compared to the measurements and provide a good description of the data, except for the case of the azimuthal opening angle.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This Letter describes a model-independent search for the production of new resonances in photon + jet events using 20 inverse fb of proton--proton LHC data recorded with the ATLAS detector at a centre-of-mass energy of s√ = 8 TeV. The photon + jet mass distribution is compared to a background model fit from data; no significant deviation from the background-only hypothesis is found. Limits are set at 95% credibility level on generic Gaussian-shaped signals and two benchmark phenomena beyond the Standard Model: non-thermal quantum black holes and excited quarks. Non-thermal quantum black holes are excluded below masses of 4.6 TeV and excited quarks are excluded below masses of 3.5 TeV.