843 resultados para “Hybrid” implementation model


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present thesis was to investigate the influence of lower-limb joint models on musculoskeletal model predictions during gait. We started our analysis by using a baseline model, i.e., the state-of-the-art lower-limb model (spherical joint at the hip and hinge joints at the knee and ankle) created from MRI of a healthy subject in the Medical Technology Laboratory of the Rizzoli Orthopaedic Institute. We varied the models of knee and ankle joints, including: knee- and ankle joints with mean instantaneous axis of rotation, universal joint at the ankle, scaled-generic-derived planar knee, subject-specific planar knee model, subject-specific planar ankle model, spherical knee, spherical ankle. The joint model combinations corresponding to 10 musculoskeletal models were implemented into a typical inverse dynamics problem, including inverse kinematics, inverse dynamics, static optimization and joint reaction analysis algorithms solved using the OpenSim software to calculate joint angles, joint moments, muscle forces and activations, joint reaction forces during 5 walking trials. The predicted muscle activations were qualitatively compared to experimental EMG, to evaluate the accuracy of model predictions. Planar joint at the knee, universal joint at the ankle and spherical joints at the knee and at the ankle produced appreciable variations in model predictions during gait trials. The planar knee joint model reduced the discrepancy between the predicted activation of the Rectus Femoris and the EMG (with respect to the baseline model), and the reduced peak knee reaction force was considered more accurate. The use of the universal joint, with the introduction of the subtalar joint, worsened the muscle activation agreement with the EMG, and increased ankle and knee reaction forces were predicted. The spherical joints, in particular at the knee, worsened the muscle activation agreement with the EMG. A substantial increase of joint reaction forces at all joints was predicted despite of the good agreement in joint kinematics with those of the baseline model. The introduction of the universal joint had a negative effect on the model predictions. The cause of this discrepancy is likely to be found in the definition of the subtalar joint and thus, in the particular subject’s anthropometry, used to create the model and define the joint pose. We concluded that the implementation of complex joint models do not have marked effects on the joint reaction forces during gait. Computed results were similar in magnitude and in pattern to those reported in literature. Nonetheless, the introduction of planar joint model at the knee had positive effect upon the predictions, while the use of spherical joint at the knee and/or at the ankle is absolutely unadvisable, because it predicted unrealistic joint reaction forces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hybrid vehicles (HV), comprising a conventional ICE-based powertrain and a secondary energy source, to be converted into mechanical power as well, represent a well-established alternative to substantially reduce both fuel consumption and tailpipe emissions of passenger cars. Several HV architectures are either being studied or already available on market, e.g. Mechanical, Electric, Hydraulic and Pneumatic Hybrid Vehicles. Among the others, Electric (HEV) and Mechanical (HSF-HV) parallel Hybrid configurations are examined throughout this Thesis. To fully exploit the HVs potential, an optimal choice of the hybrid components to be installed must be properly designed, while an effective Supervisory Control must be adopted to coordinate the way the different power sources are managed and how they interact. Real-time controllers can be derived starting from the obtained optimal benchmark results. However, the application of these powerful instruments require a simplified and yet reliable and accurate model of the hybrid vehicle system. This can be a complex task, especially when the complexity of the system grows, i.e. a HSF-HV system assessed in this Thesis. The first task of the following dissertation is to establish the optimal modeling approach for an innovative and promising mechanical hybrid vehicle architecture. It will be shown how the chosen modeling paradigm can affect the goodness and the amount of computational effort of the solution, using an optimization technique based on Dynamic Programming. The second goal concerns the control of pollutant emissions in a parallel Diesel-HEV. The emissions level obtained under real world driving conditions is substantially higher than the usual result obtained in a homologation cycle. For this reason, an on-line control strategy capable of guaranteeing the respect of the desired emissions level, while minimizing fuel consumption and avoiding excessive battery depletion is the target of the corresponding section of the Thesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Within this thesis, new approaches for the concepts of peptide-polymer conjugates and peptide-based hybrid nanomaterials are investigated. In the first part, the synthesis of a triblock polymer-peptide-polymer is carried out following a typical peptide coupling reaction, both in solution and on solid-phase. The peptide sequence is chosen, so that it is cleaved by an enzyme preparation of trypsin. End-functionalized polystyrene is used as a model hydrophobic polymer and coupled to the peptide sequence. The results show successful coupling reactions in both methods, while the solid phase method produced a more defined product. Suspensions, consisting of peptide-polymer conjugates particles, are prepared in water by ultrasonication. In contact with the enzyme, the peptide constituting the conjugated particles is cleaved. This demonstrates the enzymatic cleavage in heterophase of enzymatic sequence bond to hydrophobic polymers, and is of great interest for the encapsulation and delivery of hydrophobic molecules.rnA second approach is the preparation of peptide-based hybrid nanocapsules. This is achieved by interfacial polyaddition in inverse miniemulsion with the peptide sequence functionalized with additional amino acids. A method suitable to the use of a peptide sequence for interfacial polyaddition was developed. It is shown that, the polarity of the dispersed phase influences the structures prepared, from particle-like to polymeric shell with a liquid core.rnThe peptide sequence is equipped with a FRET pair (more exactly, an internally-quenched fluorescent system) which allows the real-time monitoring of the enzymatic cleavage of the recognition site. This system shows the successful cleavage of the peptide-based nanocapsules when trypsin preparation is added to the suspensions. A water-soluble fluorescent polymer is efficiently entrapped and its possible use as marker for the capsules is highlighted. Furthermore, a small water-soluble fluorescent dye (SR-101) is successfully encapsulated and the encapsulation efficiency as a function of the functionality of the peptide and the amount of comonomer equivalent (toluene diisocyanate) is studied. The dye is encapsulated at such a high concentration, that self-quenching occurs. Thus, the release of the encapsulated dye triggered by the enzymatic cleavage of the peptide results in a fluorescence recovery of the dye. The fluorescence recovery of the FRET pair in the peptide and of the encapsulated dye correlate well.rnFinally, nanocapsules based on a hepsin-cleavable peptide sequence are prepared. Hepsin is an enzyme, which is highly upregulated in prostate cancer cells. The cleavage of the nanocapsules is investigated with healthy and “cancerous” (hepsin-expressing) cell cultures. The degradation, followed via fluorescence recovery of the FRET system, is faster for the suspensions introduced in the hepsin expressing cell cultures.rnIn summary, this work tackles the domain of responsive nanomaterials for drug delivery from a new perspective. It presents the adaptation of the miniemulsion process for hybrid peptide-based materials, and their successful use in preparing specific enzyme-responsive nanoparticles, with hydrophilic payload release properties.rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A unique characteristic of soft matter is its ability to self-assemble into larger structures. Characterizing these structures is crucial for their applications. In the first part of this work, I investigated DNA-organic hybrid material by means of Fluorescence Correlation Spectroscopy (FCS) and Fluorescence Cross-Correlation Spectroscopy (FCCS). DNA-organic hybrid materials, a novel class of hybrid materials composed of synthetic macromolecules and oligodeoxynucleotide segmenta, are mostly amphiphilic and can self-assemble into supramolecular structures in aqueous solution. A hybrid material of a fluorophore, perylenediimide (PDI), and a DNA segment (DNA-PDI) has been developed in Prof. A. Hermann’s group (University of Groningen). This novel material has the ability to form aggregates through pi-pi stacking between planar PDIs and can be traced in solution due to the fluorescence of PDI. I have determined the diffusion coefficient of DNA-PDI conjugates in aqueous solution by means of FCS. In addition, I investigated whether such DNA-PDIs form aggregates with certain structure, for instance dimers. rnOnce the DNA hybrid material self-assemble into supermolecular structures for instance into micelles, the single molecules do not necessarily stay in one specific micelle. Actually, a single molecule may enter and leave micelles constantly. The average residence time of a single molecule in a certain micelle depends on the nature of the molecule. I have chosen DNA-b-polypropylene oxide (PPO) as model molecules and investigated the residence time of DNA-b-PPO molecules in their according micelles by means of FCCS.rnBesides the DNA hybrid materials, polymeric colloids can also form ordered structures once they are brought to an air/water interface. Here, hexagonally densely packed monolayers can be generated. These monolayers can be deposited onto different surfaces as coating layers. In the second part of this work, I investigated the mechanical properties of such colloidal monolayers using micromechanical cantilevers. When a coating layer is deposited on a cantilever, it can modify the elasticity of the cantilever. This variation can be reflected either by a deflection or by a resonance frequency shift of the cantilever. In turn, detecting these changes provides information about the mechanical properties of the coating layer. rnIn the second part of this work, polymeric colloidal monolayers were coated on a cantilever and homogenous polymer films of a few hundred nanometers in thickness were generated from these colloidal monolayers by thermal annealing or organic vapor annealing. Both the film formation process and the mechanical properties of these resulting homogenous films were investigated by means of cantilever. rnElastic property changes of the coating film, for example upon absorption of organic vapors, induce a deflection of the cantilever. This effect enables a cantilever to detect target molecules, when the cantilever is coated with an active layer with specific affinity to target molecules. In the last part of this thesis, I investigated the applicability of suitably functionalized micromechanical cantilevers as sensors. In particular, glucose sensitive polymer brushes were grafted on a cantilever and the deflection of this cantilever was measured during exposure to glucose solution. rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The synthesis, characterization and application of aqueous dispersions of superparamagnetic/polymer hybrid nanoparticles and capsules is described. Implementation of the superparamagnetic moiety into the polymer matrix enables a response of the nanomaterials towards an external magnetic field. Application of the external field is used for two main purposes: i) As heat generator, when an alternating magnetic field is applied. ii) As structuring agent to self-assemble superparamagnetic nanoparticles in the external field.rnIn the first part, superparamagnetic nanoparticles were used as heat generators in order to achieve a magnetic field induced release of an active compound from nanocontainers. To achieve such a release in remote-controlled fashion, the encapsulation of superparamagnetic nanoparticles into polymer nanocapsules was combined with the integration of a thermolabile compound into the shell of the nanocontainers. The magnetic nanoparticles acted as generators for heat, which decomposed the thermolabile compound. Pores were created in the degrading shell and an active substance was released.rn Additionally, the self-assembly of polymer nanoparticles, which were labeled with a superparamagnetic moiety as structuring agent, could be demonstrated. A combination of a magnetic field induced self-assembly and a sintering of neighboring particles upon an increase in temperature above the glass transition temperature of the polymer was used to form stable architectures. Various structures with tunable periodicity could be obtained ranging from smooth linear nanofibers to zigzag fibers. Besides solely creating linear architectures, the frugal process additionally allowed the creation of arrangements in analogy to more complex polymer architectures: By the introduction of defined junction points, the generation of branched structures and networks was demonstrated. Additionally, by tailoring the interaction of differently sized particles, the preparation of nanoparticle arrangements in statistical or block copolymer fashion was shown. Moreover, a reversible linear assembly and linkage of the nanoparticles was demonstrated following a lock/unlock mechanism. Therefore, the particles were locked in their linear assembly by a stable iron(III) hydroxamato-complex and unlocked by addition of a reducing agent and formation of a less stable iron(II)-complex.Further, in various projects with collaboration partners, nanoparticles and nanocapsules were labeled with a superparamagnetic moiety for their use as contrast agents in magnetic resonance imaging or as magnetically separable dispersions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose Accurate three-dimensional (3D) models of lumbar vertebrae can enable image-based 3D kinematic analysis. The common approach to derive 3D models is by direct segmentation of CT or MRI datasets. However, these have the disadvantages that they are expensive, timeconsuming and/or induce high-radiation doses to the patient. In this study, we present a technique to automatically reconstruct a scaled 3D lumbar vertebral model from a single two-dimensional (2D) lateral fluoroscopic image. Methods Our technique is based on a hybrid 2D/3D deformable registration strategy combining a landmark-to-ray registration with a statistical shape model-based 2D/3D reconstruction scheme. Fig. 1 shows different stages of the reconstruction process. Four cadaveric lumbar spine segments (total twelve lumbar vertebrae) were used to validate the technique. To evaluate the reconstruction accuracy, the surface models reconstructed from the lateral fluoroscopic images were compared to the associated ground truth data derived from a 3D CT-scan reconstruction technique. For each case, a surface-based matching was first used to recover the scale and the rigid transformation between the reconstructed surface model Results Our technique could successfully reconstruct 3D surface models of all twelve vertebrae. After recovering the scale and the rigid transformation between the reconstructed surface models and the ground truth models, the average error of the 2D/3D surface model reconstruction over the twelve lumbar vertebrae was found to be 1.0 mm. The errors of reconstructing surface models of all twelve vertebrae are shown in Fig. 2. It was found that the mean errors of the reconstructed surface models in comparison to their associated ground truths after iterative scaled rigid registrations ranged from 0.7 mm to 1.3 mm and the rootmean squared (RMS) errors ranged from 1.0 mm to 1.7 mm. The average mean reconstruction error was found to be 1.0 mm. Conclusion An accurate, scaled 3D reconstruction of the lumbar vertebra can be obtained from a single lateral fluoroscopic image using a statistical shape model based 2D/3D reconstruction technique. Future work will focus on applying the reconstructed model for 3D kinematic analysis of lumbar vertebrae, an extension of our previously-reported imagebased kinematic analysis. The developed method also has potential applications in surgical planning and navigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Among the huge radiations of haplochromine cichlid fish in Lakes Malawi and Victoria, closely related species are often reproductively isolated via female mate choice although viable fertile hybrids can be produced when females are confined only with heterospecific males. We generated F(2) hybrid males from a cross between a pair of closely related sympatric cichlid fish from Lake Malawi. Laboratory mate choice experiments using microsatellite paternity analysis demonstrated that F(2) hybrid males differed significantly in their attractiveness to females of the two parental species, indicating heritable variation in traits involved in mate choice that may contribute to reproductive isolation between these species. We found no significant correlation between male mating success and any measurement of male colour pattern. A simple quantitative genetic model of reproductive isolation suggests that there may be as few as two chromosomal regions controlling species-specific attractiveness. We propose that adaptive radiation of Lake Malawi cichlids could be facilitated by the presence of genes with major effects on mate choice and reproductive isolation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a novel mock circulation for the evaluation of ventricular assist devices (VADs), which is based on a hardware-in-the-loop concept. A numerical model of the human blood circulation runs in real time and computes instantaneous pressure, volume, and flow rate values. The VAD to be tested is connected to a numerical-hydraulic interface, which allows the interaction between the VAD and the numerical model of the circulation. The numerical-hydraulic interface consists of two pressure-controlled reservoirs, which apply the computed pressure values from the model to the VAD, and a flow probe to feed the resulting VAD flow rate back to the model. Experimental results are provided to show the proper interaction between a numerical model of the circulation and a mixed-flow blood pump.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The electron Monte Carlo (eMC) dose calculation algorithm available in the Eclipse treatment planning system (Varian Medical Systems) is based on the macro MC method and uses a beam model applicable to Varian linear accelerators. This leads to limitations in accuracy if eMC is applied to non-Varian machines. In this work eMC is generalized to also allow accurate dose calculations for electron beams from Elekta and Siemens accelerators. First, changes made in the previous study to use eMC for low electron beam energies of Varian accelerators are applied. Then, a generalized beam model is developed using a main electron source and a main photon source representing electrons and photons from the scattering foil, respectively, an edge source of electrons, a transmission source of photons and a line source of electrons and photons representing the particles from the scrapers or inserts and head scatter radiation. Regarding the macro MC dose calculation algorithm, the transport code of the secondary particles is improved. The macro MC dose calculations are validated with corresponding dose calculations using EGSnrc in homogeneous and inhomogeneous phantoms. The validation of the generalized eMC is carried out by comparing calculated and measured dose distributions in water for Varian, Elekta and Siemens machines for a variety of beam energies, applicator sizes and SSDs. The comparisons are performed in units of cGy per MU. Overall, a general agreement between calculated and measured dose distributions for all machine types and all combinations of parameters investigated is found to be within 2% or 2 mm. The results of the dose comparisons suggest that the generalized eMC is now suitable to calculate dose distributions for Varian, Elekta and Siemens linear accelerators with sufficient accuracy in the range of the investigated combinations of beam energies, applicator sizes and SSDs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The group analysed some syntactic and phonological phenomena that presuppose the existence of interrelated components within the lexicon, which motivate the assumption that there are some sublexicons within the global lexicon of a speaker. This result is confirmed by experimental findings in neurolinguistics. Hungarian speaking agrammatic aphasics were tested in several ways, the results showing that the sublexicon of closed-class lexical items provides a highly automated complex device for processing surface sentence structure. Analysing Hungarian ellipsis data from a semantic-syntactic aspect, the group established that the lexicon is best conceived of being as split into at least two main sublexicons: the store of semantic-syntactic feature bundles and a separate store of sound forms. On this basis they proposed a format for representing open-class lexical items whose meanings are connected via certain semantic relations. They also proposed a new classification of verbs to account for the contribution of the aspectual reading of the sentence depending on the referential type of the argument, and a new account of the syntactic and semantic behaviour of aspectual prefixes. The partitioned sets of lexical items are sublexicons on phonological grounds. These sublexicons differ in terms of phonotactic grammaticality. The degrees of phonotactic grammaticality are tied up with the problem of psychological reality, of how many degrees of this native speakers are sensitive to. The group developed a hierarchical construction network as an extension of the original General Inheritance Network formalism and this framework was then used as a platform for the implementation of the grammar fragments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We derive a new class of iterative schemes for accelerating the convergence of the EM algorithm, by exploiting the connection between fixed point iterations and extrapolation methods. First, we present a general formulation of one-step iterative schemes, which are obtained by cycling with the extrapolation methods. We, then square the one-step schemes to obtain the new class of methods, which we call SQUAREM. Squaring a one-step iterative scheme is simply applying it twice within each cycle of the extrapolation method. Here we focus on the first order or rank-one extrapolation methods for two reasons, (1) simplicity, and (2) computational efficiency. In particular, we study two first order extrapolation methods, the reduced rank extrapolation (RRE1) and minimal polynomial extrapolation (MPE1). The convergence of the new schemes, both one-step and squared, is non-monotonic with respect to the residual norm. The first order one-step and SQUAREM schemes are linearly convergent, like the EM algorithm but they have a faster rate of convergence. We demonstrate, through five different examples, the effectiveness of the first order SQUAREM schemes, SqRRE1 and SqMPE1, in accelerating the EM algorithm. The SQUAREM schemes are also shown to be vastly superior to their one-step counterparts, RRE1 and MPE1, in terms of computational efficiency. The proposed extrapolation schemes can fail due to the numerical problems of stagnation and near breakdown. We have developed a new hybrid iterative scheme that combines the RRE1 and MPE1 schemes in such a manner that it overcomes both stagnation and near breakdown. The squared first order hybrid scheme, SqHyb1, emerges as the iterative scheme of choice based on our numerical experiments. It combines the fast convergence of the SqMPE1, while avoiding near breakdowns, with the stability of SqRRE1, while avoiding stagnations. The SQUAREM methods can be incorporated very easily into an existing EM algorithm. They only require the basic EM step for their implementation and do not require any other auxiliary quantities such as the complete data log likelihood, and its gradient or hessian. They are an attractive option in problems with a very large number of parameters, and in problems where the statistical model is complex, the EM algorithm is slow and each EM step is computationally demanding.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A major barrier to widespread clinical implementation of Monte Carlo dose calculation is the difficulty in characterizing the radiation source within a generalized source model. This work aims to develop a generalized three-component source model (target, primary collimator, flattening filter) for 6- and 18-MV photon beams that match full phase-space data (PSD). Subsource by subsource comparison of dose distributions, using either source PSD or the source model as input, allows accurate source characterization and has the potential to ease the commissioning procedure, since it is possible to obtain information about which subsource needs to be tuned. This source model is unique in that, compared to previous source models, it retains additional correlations among PS variables, which improves accuracy at nonstandard source-to-surface distances (SSDs). In our study, three-dimensional (3D) dose calculations were performed for SSDs ranging from 50 to 200 cm and for field sizes from 1 x 1 to 30 x 30 cm2 as well as a 10 x 10 cm2 field 5 cm off axis in each direction. The 3D dose distributions, using either full PSD or the source model as input, were compared in terms of dose-difference and distance-to-agreement. With this model, over 99% of the voxels agreed within +/-1% or 1 mm for the target, within 2% or 2 mm for the primary collimator, and within +/-2.5% or 2 mm for the flattening filter in all cases studied. For the dose distributions, 99% of the dose voxels agreed within 1% or 1 mm when the combined source model-including a charged particle source and the full PSD as input-was used. The accurate and general characterization of each photon source and knowledge of the subsource dose distributions should facilitate source model commissioning procedures by allowing scaling the histogram distributions representing the subsources to be tuned.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Study of behavior and influence of a multileaf collimator (MLC) on dose calculation, verification, and portal energy spectra in the case of intensity-modulated fields obtained with a step-and-shoot or a dynamic technique. METHODS: The 80-leaf MLC for the Varian Clinac 2300 C/D was implemented in a previously developed Monte Carlo (MC) based multiple source model (MSM) for a 6 MV photon beam. Using this model and the MC program GEANT, dose distributions, energy fluence maps and energy spectra at different portal planes were calculated for three different MLC applications. RESULTS: The comparison of MC-calculated dose distributions in the phantom and portal plane, with those measured with films showed an agreement within 3% and 1.5 mm for all cases studied. The deviations mainly occur in the extremes of the intensity modulation. The MC method allows to investigate, among other aspects, dose components, energy fluence maps, tongue-and-groove effects and energy spectra at portal planes. CONCLUSION: The MSM together with the implementation of the MLC is appropriate for a number of investigations in intensity-modulated radiation therapy (IMRT).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Implementation of an experimental model to compare cartilage MR imaging by means of histological analyses. MATERIAL AND METHODS: MRI was obtained from 4 patients expecting total knee replacement at 1.5 and/or 3T prior surgery. The timeframe between pre-op MRI and knee replacement was within two days. Resected cartilage-bone samples were tagged with Ethi((R))-pins to reproduce the histological cutting course. Pre-operative scanning at 1.5T included following parameters for fast low angle shot (FLASH: TR/TE/FA=33ms/6ms/30 degrees , BW=110kHz, 120mmx120mm FOV, 256x256 matrix, 0.65mm slice-thickness) and double echo steady state (DESS: TR/TE/FA=23.7ms/6.9ms/40 degrees , BW=130kHz, 120x120mm FOV, 256x256 matrix, 0.65mm slice-thickness). At 3T, scan parameters were: FLASH (TR/TE/FA=12.2ms/5.1ms/10 degrees , BW=130kHz, 170x170mm FOV, 320x320, 0.5mm slice-thickness) and DESS (TR/TE/FA=15.6ms/4.5ms/25 degrees , BW=200kHz, 135mmx150mm FOV, 288x320matrix, 0.5mm slice-thickness). Imaging of the specimens was done the same day at 1.5T. MRI (Noyes) and histological (Mankin) score scales were correlated using the paired t-test. Sensitivity and specificity for the detection of different grades of cartilage degeneration were assessed. Inter-reader and intra-reader reliability was determined using Kappa analysis. RESULTS: Low correlation (sensitivity, specificity) was found for both sequences in normal to mild Mankin grades. Only moderate to severe changes were diagnosed with higher significance and specificity. The use of higher field-strengths was advantageous for both protocols with sensitivity values ranging from 13.6% to 93.3% (FLASH) and 20.5% to 96.2% (DESS). Kappa values ranged from 0.488 to 0.944. CONCLUSIONS: Correlating MR images with continuous histological slices was feasible by using three-dimensional imaging, multi-planar-reformat and marker pins. The capability of diagnosing early cartilage changes with high accuracy could not be proven for both FLASH and DESS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of shot particles on the high temperature, low cycle fatigue of a hybrid fiber/particulate metal-matrix composite (MMC) was studied. Two hybrid composites with the general composition A356/35%SiC particle/5%Fiber (one without shot) were tested. It was found that shot particles acting as stress concentrators had little effect on the fatigue performance. It appears that fibers with a high silica content were more likely to debond from the matrix. Final failure of the composite was found to occur preferentially in the matrix. SiC particles fracture progressively during fatigue testing, leading to higher stress in the matrix, and final failure by matrix overload. A continuum mechanics based model was developed to predict failure in fatigue based on the tensile properties of the matrix and particles. By accounting for matrix yielding and recovery, composite creep and particle strength distribution, failure of the composite was predicted.