996 resultados para video imaging
Resumo:
Iowa Department of Transportation Fiscal Year 2007 Report of Savings by Using Video Conferencing Through Iowa Communications Network to the Iowa General Assembly Pursuant to Chapter II 84 Acts and Joint Resolutions Enacted at the 1994 Regular Session of the 75th General Assembly of the State of Iowa Code section 8D.10 Report of Savings by State Agencies Iowa Code section 8D.10 requires certain state agencies prepare an annual report to the General Assembly certifying the identified savings associated with that state agency’s use of the Iowa Communications Network (ICN). This report covers estimated cost savings related to video conferencing via ICN for the Iowa Department of Transportation (DOT). In FY 2007, the DOT conducted two sessions utilizing ICN’s video conferencing system. These two sessions included DOT employees in Ames with non-DOT participants at remote ICN sites. Since the cost savings is calculated based on DOT staff savings, no cost savings from these conferences were gained because the public participants were attending from the ICN sites.
Resumo:
PURPOSE: To suppress the noise, by sacrificing some of the signal homogeneity for numerical stability, in uniform T1 weighted (T1w) images obtained with the magnetization prepared 2 rapid gradient echoes sequence (MP2RAGE) and to compare the clinical utility of these robust T1w images against the uniform T1w images. MATERIALS AND METHODS: 8 healthy subjects (29.0±4.1 years; 6 Male), who provided written consent, underwent two scan sessions within a 24 hour period on a 7T head-only scanner. The uniform and robust T1w image volumes were calculated inline on the scanner. Two experienced radiologists qualitatively rated the images for: general image quality; 7T specific artefacts; and, local structure definition. Voxel-based and volume-based morphometry packages were used to compare the segmentation quality between the uniform and robust images. Statistical differences were evaluated by using a positive sided Wilcoxon rank test. RESULTS: The robust image suppresses background noise inside and outside the skull. The inhomogeneity introduced was ranked as mild. The robust image was significantly ranked higher than the uniform image for both observers (observer 1/2, p-value = 0.0006/0.0004). In particular, an improved delineation of the pituitary gland, cerebellar lobes was observed in the robust versus uniform T1w image. The reproducibility of the segmentation results between repeat scans improved (p-value = 0.0004) from an average volumetric difference across structures of ≈6.6% to ≈2.4% for the uniform image and robust T1w image respectively. CONCLUSIONS: The robust T1w image enables MP2RAGE to produce, clinically familiar T1w images, in addition to T1 maps, which can be readily used in uniform morphometry packages.
Resumo:
Cancer is a major health issue that absorbs the attention of a large part of the biomedical research. Intercalating agents bind to DNA molecules and can inhibit their synthesis and transcription; thus, they are increasingly used as drugs to fight cancer. In this work, we show how atomic force microscopy in liquid can characterize, through time-lapse imaging, the dynamical influence of intercalating agents on the supercoiling of DNA, improving our understanding of the drug's effect.
Resumo:
We propose a novel compressed sensing technique to accelerate the magnetic resonance imaging (MRI) acquisition process. The method, coined spread spectrum MRI or simply s(2)MRI, consists of premodulating the signal of interest by a linear chirp before random k-space under-sampling, and then reconstructing the signal with nonlinear algorithms that promote sparsity. The effectiveness of the procedure is theoretically underpinned by the optimization of the coherence between the sparsity and sensing bases. The proposed technique is thoroughly studied by means of numerical simulations, as well as phantom and in vivo experiments on a 7T scanner. Our results suggest that s(2)MRI performs better than state-of-the-art variable density k-space under-sampling approaches.
Resumo:
Purpose: To evaluate whether parametric imaging with contrast material-enhanced ultrasonography (US) is superior to visual assessment for the differential diagnosis of focal liver lesions (FLLs). Materials and Methods: This study had institutional review board approval, and verbal patient informed consent was obtained. Between August 2005 and October 2008, 146 FLLs in 145 patients (63 women, 82 men; mean age, 62.5 years; age range, 22-89 years) were imaged with real-time low-mechanical-index contrast-enhanced US after a bolus injection of 2.4 mL of a second-generation contrast agent. Clips showing contrast agent uptake kinetics (including arterial, portal, and late phases) were recorded and subsequently analyzed off-line with dedicated image processing software. Analysis of the dynamic vascular patterns (DVPs) of lesions with respect to adjacent parenchyma allowed mapping DVP signatures on a single parametric image. Cine loops of contrast-enhanced US and results from parametric imaging of DVP were assessed separately by three independent off-site readers who classified each lesion as benign, malignant, or indeterminate. Sensitivity, specificity, accuracy, and positive and negative predictive values were calculated for both techniques. Interobserver agreement (κ statistics) was determined. Results: Sensitivities for visual interpretation of cine loops for the three readers were 85.0%, 77.9%, and 87.6%, which improved significantly to 96.5%, 97.3%, and 96.5% for parametric imaging, respectively (P < .05, McNemar test), while retaining high specificity (90.9% for all three readers). Accuracy scores of parametric imaging were higher than those of conventional contrast-enhanced US for all three readers (P < .001, McNemar test). Interobserver agreement increased with DVP parametric imaging compared with conventional contrast-enhanced US (change of κ from 0.54 to 0.99). Conclusion: Parametric imaging of DVP improves diagnostic performance of contrast-enhanced US in the differentiation between malignant and benign FLLs; it also provides excellent interobserver agreement.
Resumo:
In this work we present a first feasibility study of the ClearPEM technology for simultaneous PET-MR imaging. The mutual electromagnetic interference (EMI) effects between both systems were evaluated on a 7 T magnet by characterizing the response behavior of the ClearPEM detectors and front-end electronics to pulsed RF power and switched magnetic field gradients; and by analyzing the MR system performance degradation from noise pickup into the RF receiver chain, and from magnetic susceptibility artifacts caused by PET front-end materials.
Resumo:
Iowa Code § 8D.10 requires certain state agencies prepare an annual report to the General Assembly certifying the identified savings associated with that state agency’s use of the Iowa Communications Network (ICN). This report covers estimated cost savings related to video conferencing via ICN for the Iowa Department of Transportation (DOT). In FY 2008, the DOT did not conduct any sessions utilizing ICN’s video conferencing system. Therefore, no cost savings were calculated for this report.
Resumo:
Solid pseudopapillary tumor of the pancreas (SPPP) is a very rare pancreatic tumor with low malignancy potential, occurring mostly in adolescent females and often not considered in the differential diagnosis of pancreas tumors in children. Patients with SPPP usually present with non specific abdominal symptoms and normal clinical laboratory tests. Between 2005 and 2007, 3 cases of SPPP were evaluated in our institution. The purpose of this communication is to describe the typical imaging findings of the SPPP tumor at US, CT and MRI and to correlate the images with the macro- and microscopic features of the lesion.
Resumo:
Cross-sectional imaging techniques such as magnetic resonance imaging and ultrasound are becoming essential tools not only for making an early diagnosis of rheumatoid arthritis, but also to help clarify the prognosis of the disease and better assess the response to various therapies. This article summarises the recommendations established in 2013 by the European League Against Rheumatism on the role of imaging in the diagnosis and follow-up of rheumatoid arthritis, while adding comments and emphasising on our Swiss experience with the use of ultrasound.
Resumo:
BACKGROUND: Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS: Fifteen prototype stents were deployed in coronary arteries of 15 healthy swine and investigated with a double-oblique, navigator-gated, free-breathing, T2-prepared, 3D cartesian gradient-echo sequence; a T2-prepared, 3D spiral gradient-echo sequence; and a T2-prepared, 3D steady-state, free-precession coronary MRA sequence. Furthermore, black-blood vessel wall imaging by a dual-inversion-recovery, turbo spin-echo sequence was performed. Artifacts of the stented vessel segment and signal intensities of the coronary vessel lumen inside and outside the stent were assessed. With all investigated sequences, the vessel lumen and wall could be visualized without artifacts, including the stented vessel segment. No signal intensity alterations inside the stent when compared with the vessel lumen outside the stent were found. CONCLUSIONS: The new, coronary MRI stent allows for completely artifact-free coronary MRA and vessel wall imaging.
Resumo:
Introduction : Un chylothorax est une pathologie comprenant des manifestations respiratoires, nutritionnelles et immunologiques. La récidive du chylothorax ou l'échec du traitement conservateur imposent un traitement chirurgical. Ce travail rapporte notre expérience de ligature supra-diaphragmatique, vidéo-assistée du canal thoracique, pour chylothorax récurrent non traumatique. Patients et méthodes : Entre 1999 et 2004, nous avons recensé six observations (quatre du côté droit, un du côté gauche et un bilateral) Le chylothorax s'est développé chez trois patients traités par radio et chimiothérapie pour tumeur (deux lymphomes et une tumeur du sein) un dans le contexte d'une lymphangioléiomatose et un après greffe cardiaque. Résultats : Les patients ont bénéficié sous anesthésie générale, d'une ligature du canal thoracique supra-diaphragmatique, vidéo-assistée. Le temps opératoire moyen a été de 102 minutes. Le chylothorax a régressé chez cinq des six patients en sept jours. Un patient a été repris par thoracotomie droite au huitième jour pour chylothorax persistant. Dans la phase post-opératoire, un patient a développé une détresse respiratoire nécessitant une ventilation mécanique. Un autre patient a présenté un chylopéritoine important traité par un stent de Le Veen®. Le séjour moyen a été de quatorze jours sans mortalité péri-opératoire. Conclusion : Le traitement du chylothorax non traumatique récurrent est, en première intention, un traitement médical. En cas de récidive ou d'échec du traitement conservateur, le traitement chirurgical par ligature du canal thoracique supra- diaphragmatique, vidéo-assistée, permet de traiter avec succès le chylothorax récurrent non traumatique. -- Background: Chylothorax is an uncommon disorder with respiratory, nutritional and immunological manifestations. Surgical management is indicated in case of recurrence or failure after conservative treatment. We report our experience with video-assisted right-sided supradiaphrag¬matic thoracic duct ligation for non-traumatic, non-postoperative persistent or recurrent chylothorax. Patients and methods: The medical records of six patients operated at our institution between 1999 and 2004 were retrospectively reviewed. A right-sided chylothorax was found in four patients, a left-sided in one, and a bilateral in one. Three patients developed chylothorax after chemotherapy and chest irradiation for malignant diseases (lymphoma in two patients and breast cancer in one), one in the context of lymphangioleiomyomatosis, one due to a non-diagnosed lymphoma, and one after heart transplantation. Results: The mean operative time was 102 min, with an average length of hospital stay of 14 days. Persistent cessation of chylous effusion within 7 days after surgery was observed in 5/6 patients without recurrence during a mean follow-up time of 41 months. One patient with undiagnosed mediastinal lymphoma required re-operation and thoracic duct ligation on day 8 by right-sided thoracotomy due to persistent chylothorax. No 30-day mortality was recorded. Two patients presented postoperative complications including respiratory insufficiency requiring mechanical ventilation in one, and chylous ascites development requiring peritoneo-venous LeVeen shunting in one patient. Conclusions: Recurrent or persistent non-traumatic chylothorax may be successfully treated by video-assisted right supradiaphragmatic thoracic duct ligation.
Resumo:
Texte intégral: http://www.springerlink.com/content/3q68180337551r47/fulltext.pdf
Resumo:
This paper compares two well known scan matching algorithms: the MbICP and the pIC. As a result of the study, it is proposed the MSISpIC, a probabilistic scan matching algorithm for the localization of an Autonomous Underwater Vehicle (AUV). The technique uses range scans gathered with a Mechanical Scanning Imaging Sonar (MSIS), and the robot displacement estimated through dead-reckoning with the help of a Doppler Velocity Log (DVL) and a Motion Reference Unit (MRU). The proposed method is an extension of the pIC algorithm. Its major contribution consists in: 1) using an EKF to estimate the local path traveled by the robot while grabbing the scan as well as its uncertainty and 2) proposing a method to group into a unique scan, with a convenient uncertainty model, all the data grabbed along the path described by the robot. The algorithm has been tested on an AUV guided along a 600m path within a marina environment with satisfactory results