824 resultados para upper respiratory tract infection (URTI)
Resumo:
At the Sixth International Cough Symposium, eleven clinical posters were presented at the podium in a formal symposium session. Here we summarize the posters and the discussions.
Resumo:
Nontypeable Haemophilus influenzae (NTHi) is a frequent commensal of the human nasopharynx that causes opportunistic infection in immunocompromised individuals. Existing evidence associates lipooligosaccharide (LOS) with disease, but the specific and relative contributions of NTHi LOS modifications to virulence properties of the bacterium have not been comprehensively addressed. Using NTHi strain 375, an isolate for which the detailed LOS structure has been determined, we compared systematically a set of isogenic mutant strains expressing sequentially truncated LOS. The relative contributions of 2-keto-3-deoxyoctulosonic acid, the triheptose inner core, oligosaccharide extensions on heptoses I and III, phosphorylcholine, digalactose, and sialic acid to NTHi resistance to antimicrobial peptides (AMP), self-aggregation, biofilm formation, cultured human respiratory epithelial infection, and murine pulmonary infection were assessed. We show that opsX, lgtF, lpsA, lic1, and lic2A contribute to bacterial resistance to AMP; lic1 is related to NTHi self-aggregation; lgtF, lic1, and siaB are involved in biofilm growth; opsX and lgtF participate in epithelial infection; and opsX, lgtF, and lpsA contribute to lung infection. Depending on the phenotype, the involvement of these LOS modifications occurs at different extents, independently or having an additive effect in combination. We discuss the relative contribution of LOS epitopes to NTHi virulence and frame a range of pathogenic traits in the context of infection.
Resumo:
High concentration levels of Ganoderma spp. spores were observed in Worcester, UK, during 2006–2010.These basidiospores are known to cause sensitization due to
the allergen content and their small dimensions. This enables them to penetrate the lower part of the respiratory tract in humans. Establishment of a link between occurring symptoms of sensitization to Ganoderma spp. and other basidiospores is challenging due to lack of information regarding spore concentration in the air. Hence, aerobiological monitoring should be conducted, and if possible extended with the construction of forecast models. Daily mean concentration of allergenic Ganoderma spp. spores in the atmosphere of Worcester was measured using 7-day volumetric spore sampler through five consecutive years. The relationships between the presence of spores in the air and the weather parameters were examined. Forecast models were constructed for Ganoderma spp. spores using advanced statistical techniques, i.e. multivariate regression trees and artificial neural networks. Dew point temperature along with maximumtemperature was the most important factor influencing the presence of spores in the air of Worcester. Based on these two major factors and several others of lesser importance, thresholds for certain levels of fungal spore concentration, i.e. low (0–49 s m−3), moderate(50–99 s m−3), high (100–149 s m−3) and very high (150
Resumo:
The impact of climate change on fungal growth and spore production is less well documented than for allergenic pollen grains, although similar implications for respiratory tract diseases in humans occur. Fungal spores are commonly described as either “dry” or “wet” according to the type of weather associated with their occurrence in the air. This study examined the distribution of selected fungal spores (Alternaria spp., Cladosporium spp., Didymella spp., Epicoccum spp., Leptosphaeria spp. and rusts) occurring in the West Midlands of UK during 2 years of contrasting weather. Spore specimens were collected using a 7-day volumetric air sampler and then analysed with the aid of light microscopy. Distributions of spores were then studied using normality tests and Mann–Whitney U test, while relationships with meteorological parameters were investigated using Spearman’s rank test and angular-linear correlation for wind direction analysis. Our results showed that so-called wet spores were more sensitive to the weather changes showing statistically significant differences between the 2 years of study, in contrast to “dry” spores. We predict that in following years we will observe accelerated levels in allergenic fungal spore production as well as changes in species diversity. This study could be a starting point to revise the grouping system of fungal spores as either “dry” or “wet” types and their response to climate change
Resumo:
Air quality is an increasing concern of the European Union, local authorities, scientists and most of all inhabitants that become more aware of the quality of the surrounding environment. Bioaerosols may be consisted of various elements, and the most important are pollen grains, fungal spores, bacteria, viruses. More than 100 genera of fungal spores have been identified as potential allergens that cause immunological response in susceptible individuals. Alternaria and Cladosporium have been recognised as the most important fungal species responsible for respiratory tract diseases, such as asthma, eczema, rhinitis and chronic sinusitis. While a lot of attention has been given to these fungal species, a limited number of studies can be found on Didymella and Ganoderma, although their allergenic properties were proved clinically. Monitoring of allergenic fungal spore concentration in the air is therefore very important, and in particular at densely populated areas like Worcester, UK. In this thesis a five year spore data set was presented, which was collected using a 7-day volumetric spore trap, analysed with the aid of light microscopy, statistical tests and geographic information system techniques. Although Kruskal-Wallis test detected statistically significant differences between annual concentrations of all examined fungal spore types, specific patterns in their distribution were also found. Alternaria spores were present in the air between mid-May/mid-June until September-October with peak occurring in August. Cladosporium sporulated between mid-May and October, with maximum concentration recorded in July. Didymella spores were seen from June/July up to September, while peaks were found in August. Ganoderma produced spores for 6 months (May-October), and maximum concentration could be found in September. With respect to diurnal fluctuations, Alternaria peaked between 22:00h and 23:00h, Cladosporium 13:00-15:00h, Didymella 04:00-05:00h and 22:00h-23:00h and Ganoderma from 03:00h to 06:00h. Spatial analysis showed that sources of all fungal species were located in England, and there was no evidence for a long distance transport from the continent. The maximum concentration of spores was found several hours delayed in comparison to the approximate time of the spore release from the crops. This was in agreement with diurnal profiles of the spore concentration recorded in Worcester, UK. Spores of Alternaria, Didymella and Ganoderma revealed a regional origin, in contrast to Cladosporium, which sources were situated locally. Hence, the weather conditions registered locally did not exhibit strong statistically significant correlations with fungal spore concentrations. This has had also an impact on the performance of the forecasting models. The best model was obtained for Cladosporium with 66% of the accuracy.
Resumo:
According to numerous studies, airborne nanoparticles have a potential to produce serious adverse human health effects when deposited into the respiratory tract. The most important parts of the lung are the alveolar regions with their enormous surface areas and potential to transfer nanoparticles into the blood stream. These effects may be potentiated in case of the elderly, since this population is more susceptible to air pollutants in general and more to nanoparticles than larger particles. The main goal of this investigation was to determine the exposure of institutionalized elders to nanoparticles using Nanoparticle Surface Area Monitor (NSAM) equipment to calculate the deposited surface area (DSA) of nanoparticles into elderly lungs. In total, 193 institutionalized individuals over 65 yr of age were examined in four elderly care centers (ECC). The occupancy daily pattern was achieved by applying a questionnaire, and it was concluded that these subjects spent most of their time indoors, including the bedroom and living room, the indoor microenvironments with higher prevalence of elderly occupancy. The deposited surface area ranged from 10 to 46 mu m(2)/cm(3). The living rooms presented significantly higher levels compared with bedrooms. Comparing PM10 concentrations with nanoparticles deposited surface area in elderly lungs, it is conceivable that living rooms presented the highest concentration of PM10 and were similar to the highest average DSA. The temporal distribution of DSA was also assessed. While data showed a quantitative fluctuation in values in bedrooms, high peaks were detected in living rooms.
Resumo:
Introduction: Lower Respiratory Tract Infections (LRTIs) are highly prevalent in institutionalised people with dementia, constituting an important cause of morbidity and mortality. Computerised auscultation of Adventitious Lung Sounds (ALS) has shown to be objective and reliable to assess and monitor respiratory diseases, however its application in people with dementia is unknown. Aim: This study characterised ALS (crackles and wheezes) in institutionalised people with dementia. Methods: An exploratory descriptive study, including 6 long-term care institutions was conducted. The sample included a dementia group (DG) of 30 people with dementia and a match healthy group (HG) of 30 elderly people. Socio-demographic and anthropometric data, cognition, type and severity of dementia, cardio-respiratory parameters, balance, mobility and activities and participation were collected. Lung sounds were recorded with a digital stethoscope following Computerised Respiratory Sound Analysis (CORSA) guidelines. Crackles’ location, number (N), frequency (F), two-cycle duration (2CD), initial deflection width (IDW) and largest deflection width (LDW) and wheezes’ number (N), ratio (R) and frequency (F) were analysed per breathing phase. Statistical analyses were performed using PASW Statistics(v.19). Results: There were no significant differences between the two groups in relation to the mean N of crackles during inspiration and expiration in both trachea and thorax. DG trachea crackles had significant higher F during inspiration and lower IDW, 2CD and LDW during expiration when compared with HG. At the thorax, the LDW during inspiration was also significantly lower in the DG. A significant higher N of inspiratory wheezes was found in the HG. Both groups had a low ratio of high frequency wheezes. Conclusion: Computerised analyses of ALS informed on the respiratory system and function of people with dementia and elderly people. Hence, this could be the step towards prevention, early diagnosis and continuous monitoring of respiratory diseases in people with cognitive impairment.
Resumo:
BACKGROUND: Upper gastrointestinal bleeding is the severe complication of stress-related mucosal disease in hospitalized patients. In intensive care units (ICU), risk factors are well defined and only mechanical ventilation and coagulopathy proved to be relevant for significant bleeding. On the contrary, in non-ICU settings there is no consensus about this issue. Nevertheless, omeprazole is still widely used in prophylaxis of bleeding. The objective of our study was to evaluate the relevance of stress-related mucosal disease bleeding in patients admitted to an internal medicine ward, and the role of omeprazole in its prophylaxis. METHODS: We conducted a retrospective study in which we analysed consecutive patients who were admitted to our ward over a year. We recorded demographic characteristics of the patients, potential risk factors for stress-related mucosal disease (clinical data, laboratory, and medication), administration of prophylactic omeprazole, and total cost of this prophylaxis. Patients with active gastrointestinal bleeding on the admission were excluded. We recorded every upper gastrointestinal bleeding event with clinical relevance. RESULTS: Five hundred and thirty-five patients, mean age 70 years, mean length of stay 9.6+/-7.7 days; 140 (26.2%) patients were treated with 40 mg of omeprazole intravenously, 193 (36.1%) with 20mg of omeprazole orally, and 202 (37.8%) patients had no prophylaxis. There was only one episode (0.2%) of clinically relevant bleeding. CONCLUSION: In patients admitted to an internal medicine ward, incidence of upper gastrointestinal bleeding as a complication of stress-related mucosal disease is low. We found that there is no advantage in prophylaxis with omeprazole.
Resumo:
RESUMO - Introdução: As infecções associadas aos cuidados de saúde são um importante problema de saúde pública. Entre elas, as infecções urinárias são as mais frequentes associando‐se a elevados custos e morbilidade. Pretende‐se caracterizar as ITU adquiridas no Hospital (ITUaH) ocorridas num serviço de Medicina Interna de um hospital português. Métodos: Efectuou‐se um estudo de coorte (histórica) para determinação da incidência da ITUaH e da bacteriúria assintomática. Analisaram-se os dados correspondentes a uma amostra aleatória sistemática de 388 doentes, representativa dos 3492 admissões ocorridas, em 2014, nesse Serviço. Resultados: A taxa de incidência global de ITUaH foi de 6,2% (24/388; IC 95%:[3,8--‐8,6%]). Ocorreram 19,76 ITU por mil dias de cateter vesical (ITUaCV) e 4,17 ITUaCV por mil dias de internamento. A taxa de incidência de ITUaCV foi de 4% (15/388; IC 95%:[2%--‐6%]). Oitenta por cento destas infecções ocorreram em doentes sem indicação para a algaliação. Um quarto dos doentes desta coorte foram algaliados (24,7%; IC 95%: [20%--‐29%]), não se verificando indicação para o procedimento em 36,5% dos casos. Os principais factores de risco para a algaliação identificados foram a dependência total (OR: 24,47; IC 95%: [5,50--‐ 108,87]; p<0,001) a dependência grave (OR:11,43; IC 95% [2,56--‐50,93]; p=0,001) (escala de Barthel) e a carga de doença (OR: 1,19; IC 95% [1,03--‐1,38]; p=0,017) (índice de comorbilidade de Charlson). Foram utilizados CV em 759 dias dos 3591 dias de internamento quantificados neste estudo (21%). A Taxa de incidência de Bacteriúria Assintomática (BA) foi de 4,4% (IC 95%:[2--‐6%]). Cerca de 60% (10/17) desses doentes foram submetidos a tratamento contrariamente às recomendações clínicas actuais. Conclusões: Este estudo evidencia a necessidade de implementação de estratégias de prevenção, das quais se destaca a redução do número de algaliações. O tratamento da BA deve ser evitado.
Resumo:
Increasingly the development of novel therapeutic strategies is taking into consideration the contribution of the intestinal microbiota to health and disease. Dysbiosis of the microbial communities colonizing the human intestinal tract has been described for a variety of chronic diseases, such as inflammatory bowel disease, obesity and asthma. In particular, reduction of several so-called probiotic species including Lactobacilli and Bifidobacteria that are generally considered to be beneficial, as well as an outgrowth of potentially pathogenic bacteria is often reported. Thus a tempting therapeutic approach is to shape the constituents of the microbiota in an attempt to restore the microbial balance towards the growth of 'health-promoting' bacterial species. A twist to this scenario is the recent discovery that the respiratory tract also harbors a microbiota under steady-state conditions. Investigators have shown that the microbial composition of the airway flora is different between healthy lungs and those with chronic lung diseases, such as asthma, chronic obstructive pulmonary disease as well as cystic fibrosis. This is an emerging field, and thus far there is very limited data showing a direct contribution of the airway microbiota to the onset and progression of disease. However, should future studies provide such evidence, the airway microbiota might soon join the intestinal microbiota as a target for therapeutic intervention. In this review, we highlight the major advances that have been made describing the microbiota in chronic lung disease and discuss current and future approaches concerning manipulation of the microbiota for the treatment and prevention of disease.
Resumo:
The mechanisms regulating systemic and mucosal IgA responses in the respiratory tract are incompletely understood. Using virus-like particles loaded with single-stranded RNA as a ligand for TLR7, we found that systemic vs mucosal IgA responses in mice were differently regulated. Systemic IgA responses following s.c. immunization were T cell independent and did not require TACI or TGFbeta, whereas mucosal IgA production was dependent on Th cells, TACI, and TGFbeta. Strikingly, both responses required TLR7 signaling, but systemic IgA depended upon TLR7 signaling directly to B cells whereas mucosal IgA required TLR7 signaling to lung dendritic cells and alveolar macrophages. Our data show that IgA switching is controlled differently according to the cell type receiving TLR signals. This knowledge should facilitate the development of IgA-inducing vaccines.
Resumo:
Through this paper. we have attempted to model the demand for different classes of antibiotics used for respiratory infections in outpatient care in Switzerland using a spatial version of the linear approximate Almost Ideal Demand System (AIDS) model. This model takes spatial dependency into account by means of spatial lags of antibiotic budget shares. We control for the health status of patients and the potential harmful effects of antibiotic use in terms of bacterial resistance. Elasticities to socioeconomic determinants of consumption and own- and cross-price elasticities between different groups of antibiotic have also been computed in this paper. Significant cross-price elasticities are found between newer or more expensive generations and older or less expensive generations of antibiotics. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
A growing number of studies have identified cleaners as a group at risk for adverse health effects of the skin and the respiratory tract. Chemical substances present in cleaning products could be responsible for these effects. Currently, only limited information is available about irritant and health hazardous chemical substances found in cleaning products. We hypothesized that chemical substances present in cleaning products are known health hazardous substances that might be involved in adverse health effects of the skin and the respiratory tract. We performed a systematic review of cleaning products used in the Swiss cleaning sector. We surveyed Swiss professional cleaning companies (n = 1476) to identify the most used products (n = 105) for inclusion. Safety data sheets (SDSs) were reviewed and hazardous substances present in cleaning products were tabulated with current European and global harmonized system hazard labels. Professional cleaning products are mixtures of substances (arithmetic mean 3.5 +/- 2.8), and more than 132 different chemical substances were identified in 105 products. The main groups of chemicals were fragrances, glycol ethers, surfactants, solvents; and to a lesser extent, phosphates, salts, detergents, pH-stabilizers, acids, and bases. Up to 75% of products contained irritant (Xi), 64% harmful (Xn) and 28% corrosive (C) labeled substances. Hazards for eyes (59%) and skin (50%), and hazards by ingestion (60%) were the most reported. Cleaning products potentially give rise to simultaneous exposures to different chemical substances. As professional cleaners represent a large workforce, and cleaning products are widely used, it is a major public health issue to better understand these exposures. The list of substances provided in this study contains important information for future occupational exposure assessment studies.
Resumo:
Measurements and simulations were performed to assess workers' exposure to solvent vapors and aerosols during the waterproofing of a tiled surface. This investigation followed two recent incidents in the same company where workers experienced acute respiratory illness after spraying a stain-repellent resin containing fluorinated polymers on stone-tiled walls and floors. Because the waterproofing activity had been done for years at the tile company without encountering any exposure problems prior to these cases, it was strongly suspected that the incidents were linked to a recent change in the composition of the coating mixture. Experimental measurements and simulations indicated that the emission rate of particles smaller than 10 microm may be estimated at 0.66 mg/sec (SD 0.10) for the old resin and at 0.37 mg/sec (SD 0.04) for the new one. The measurement of the solvent emission rate from surfaces coated with the two resins indicated that shortly after spraying, the emission was in the range of 18 to 20 mg/sec x m2 and was similar for both products. Solvent and overspray emission rates were introduced in a two-zone compartment model. The results obtained in the near-field indicate significant exposure to overspray mist (7 and 34 mg/m3 for new resin) and solvent vapors (80 to 350 ppm for the new resin). It was also shown that the introduction of the new resin tended to significantly decrease the levels of solvents and particulates in the workers' breathing zone. These results strongly suggest that cases of acute respiratory illness are related to the specific toxicity of the fluorinated polymer itself. The fact that the same polymer is used in various commercial products raises concern regarding other possible occupational and domestic exposures.