880 resultados para thermoplastic extrusion


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the periodontal conditions of anterior teeth that presented pathologic migration in patients with chronic periodontitis and to compare periodontal destruction in migrated versus non-migrated teeth. The sample included 32 patients of both sexes (mean age: 46.0 +/- 11.6 years) diagnosed with generalized chronic periodontitis and selected on the basis of the presence of pathologic migration in one or more anterior teeth. This migration was classified according to the following categories: facial flaring, diastema, proximal tilting, rotation or extrusion. The periodontal parameters recorded were clinical attachment loss (CAL) and percentage of radiographic bone loss (BL). Mean CAL of 5.50 +/- 2.20 mm and mean BL of 41.90 +/- 15.40% were found in 115 teeth assessed. The most frequent type of migration was facial flaring (34.80%), followed by diastema (27.00%). Extrusion was hardly observed in the sample (4.30%). However, greater severity of BL and CAL were observed in teeth with this type of migration (59.44% and 8.42 mm, respectively), and in teeth with facial flaring (45.17% of BL and 6.07 mm of CAL). Kruskal-Wallis test indicated that BL presented by teeth with extrusion or facial flaring was greater than that observed in rotated or tilted teeth (p < 0.05), while there was no difference between groups regarding CAL (p = 0.11). It was observed that anterior teeth with pathologic migration presented greater CAL and BL (5.1 mm and 40%) than non-migrated teeth (4.1 and 31%). The study indicated that the most prevalent kind of pathologic migration is facial flaring, which was associated to higher level of bone loss.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carbon/epoxy 8552 prepreg is a thermoplastic toughened high-performance epoxy being used in the manufacture of advanced army material. Understanding the cure behavior of a thermosetting system is essential in the development and optimization of composite fabrication processes. The cure kinetics and rheological behavior were evaluated using a differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA) and a rheometer. Values of the kinetic parameters were obtained from dynamic DSC scans using an nth order reaction model. Rheological measurements as a function of temperature and time were made for the prepreg system. The manufacturer's recommended cure cycle was evaluated and considered adequate to consolidated the studied system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Effect of extrusion parameters was studied on the expansion index, specific volume, water absorption index (WAI) and water solubility index (WSI) of expanded yam snacks. The central composite design was used to study the parameters effect. It was verified three levels of temperature in the barrel (100, 115 and 130°C), three levels of screw speed (163, 204 and 245 rpm) and three levels of flour moisture (12, 15 and 18%). The results showed that expansion properties (expansion index and specific volume) depend on flour moisture and extrusion temperature. The WSI was dependant of three parameters. Higher levels of temperature and screw speed increase the water solubility index (WSI). The studied parameters did not influence the water absorption index (WAI).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to analyze the morphometry of hybrids' eggs under stereomicroscopy. The induced reproduction was carried out in specimens of pintado's females (P. corruscans) and cachara's males (P. fasciatum) from Cepta - Ibama, Pirassununga, state of São Paulo, Brazil. Samples were collected in extrusion moment, during the fertilization, in times of 10 and 30 seconds, 1, 2, 5, 8, 10, 15, 20, 30 and 45 minutes, 1 hour, at every 15 minutes until completing 2 hours, and afterwards, at every hour until the larval hatching. Oocytes and eggs' external morphology were observed, photographed and 30 samples from each moment were measured in stereomicroscopy. Oocytes, in the time of extrusion, and the eggs presented a spherical form and yellowish color. Characteristics such as wide perivitelinic space, somites, presence of optical vesicle and the main phases of embryonic development as egg-cell (blastodisc), 2, 4, 8, 16, 32 and 64 blastomeres, morula, blastula, gastrula, epiboly movements, formation and larvae hatching were verified.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this study was to evaluate the thermoplasticity of conventional and thermoplastic gutta-percha and Resilon®, a polyester polymer-based material. Specimens with standardised dimensions were made from the following materials: conventional and thermoplastic gutta-percha (Dentsply), conventional and thermoplastic gutta-percha (Endopoints) and Resilon®. After 24 h, the specimens were placed in water at 70°C for 60 s, and thereafter positioned between two glass slabs. Each set was compressed by a 5-kg weight. Digital images of the specimens before and after compression were obtained and analysed. The thermoplasticity of each material was confirmed by the difference between final and initial areas of each sample. The data were analysed statistically by ANOVA and Tukey's test at a 5% significance level. Resilon® had the highest thermoplasticity means (P < 0.05). Among the gutta-percha cones, Endopoints TP (thermoplastic) presented the highest thermoplasticity means and differed significantly from the other commercial brands (P < 0.05). Resilon® had good thermoplasticity, endorsing its use as a thermoplastic root canal filling material. © 2007 The Authors. Journal compilation © 2007 Australian Society of Endodontology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the characteristics of patients with anophthalmic cavity who developed sphere extrusion. Methods: A retrospective observational study was done evaluating 37 patients with anophthalmic cavity and sphere extrusion at the Faculdade de Medicina de Botucatu-UNESP. Results: Extrusion was observed in enucleated and eviscerated cavities. The majority of the patients had the eye removed because of phthisis bulbi or trauma and the extrusion happened 1 or 2 years after the surgery. Extrusion was preceded by conjunctival dehiscence and exposure of the sphere and occurred with all used implants. Conclusion: Complications after orbital implant placement are a possibility. Dehiscence and sphere extrusion may happen and another surgery would be necessary. The patient and the ophthalmologist have to be prepared for this.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the histological and systemic response to subcutaneous injection of polyethylene gel in rats. Methods: Twenty-one white male rats were divided into 3 groups (G): G1 and G2 received subcutaneous polyethylene gel injection in the dorsal midline and were sacrificed at 30 and 60 postoperative days, respectively. G3 was not exposed to the polyethylene gel and was sacrificed after 60 days. Blood levels of lactate dehydrogenase (LDH), creatine kinase (CK), and alkaline phosphatase (ALP) were evaluated. The heart, kidney, liver, adrenal gland, injection site, and adjacent tissues were histologically examined. The results were submitted to statistical analysis. Results: There was no clinical evidence of extrusion, reduction of the injected volume, or abnormalities in the adjacent tissues. Blood levels of CK and LDH were normal and similar in all groups. ALP levels were significantly lower in G2 than in G1 and G3. The systemic organs were normal on histological examination in the 3 groups evaluated. Microscopically, the polyethylene gel was surrounded by a thin pseudocapsule formation and minimal inflammatory cell response, which decreased from G1 to G2. Conclusion: The subcutaneous injection of polyethylene gel in rats elicited minimal local inflammatory response and no systemic side effects. Copyright © 2008 Informa Healthcare USA, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: The aim of this study was to assess the thermoplasticity of materials used in root canal filling. Methods: Specimens with standardized dimensions were fabricated using Tanari, Roeko and Activ Point gutta-percha cones, as well as Microseal and TC gutta-percha. After 24 hours, the specimens were placed in water at 70 °C for 60 seconds and positioned between two glass slabs. Each set was compressed by a 5 g weight. Digital images of the specimens before and after compression were obtained and analyzed. The thermoplasticity was evaluated based on the difference between the final and initial areas. Data were statistically analyzed using ANOVA and Tukey's tests at a 5% significance level. Results: TC and Microseal gutta-percha presented the highest thermoplasticity (p < 0.05). Among the gutta-percha cones, Tanari and Roeko presented the highest thermoplasticity and differed when compared to Activ Point (p < 0.05). Conclusions: The results of the present study showed that TC and Microseal gutta-percha filling systems present better thermoplastic properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effectiveness of different light-curing units on the bond strength (push-out) of glass fiber posts in the different thirds of the root (cervical, middle and apical) with different adhesive luting resin systems (dual-cure total-etch; dual-cured and self-etch bonding system; and dual-cure self-adhesive cements), Disks of the samples (n = 144) were used, with approximately 1 mm of thickness of 48 bovine roots restored with glass fiber posts, that were luted with resin cements photo-activated by halogen LCU (QTH, Optilux 501) and blue LED (Ultraled), with power densities of 600 and 550 mW/cm 2, respectively. A universal testing machine (MTS 810 Material Test System) was used with a 1 mm diameter steel rod at cross-head speed of 0.5 mm/min until post extrusion, with load cell of 50 kg, for evaluation of the push-out strength in the different thirds of each sample. The push-out strength values in kgf were converted to MPa and analyzed through Analysis of Variance and Tukey's test, at significance level of 5%. The results showed that there were no statistical differences between the QTH and LED LCUs. The self-adhesive resin cement had lower values of retention. The total-etch and self-adhesive system resin cements seem to be a possible alternative for glass fiber posts cementation into the radicular canal and the LED LCU can be applied as an alternative to halogen light on photo-activation of dual-cured resin cements. © 2009 Pleiades Publishing, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Among the factors that influence the success of treatment of a root perforation, its location and possibility of contamination are determinant because the interaction of these 2 factors may result in significant periodontal injury. The management of cases of hard-to-reach contaminated perforations depends on the choice of an adequate technique. In the case reported in this article, controlled orthodontic tooth extrusion was successfully performed to treat gingival recession secondary to root perforation. The outcomes showed that this technique preserves the zone of attached gingiva, maintains the crown height, and prevents the involvement of the supporting bone tissue. The favorable clinical and radio?graphic conditions after 7 years of follow-up demonstrate the viability of this treatment approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effectiveness of 3 solvents (eucalyptol, orange oil, and xylol) on 2 types of gutta-percha (conventional and thermoplastic) and Resilon. Specimens (10 mm diameter × 1 mm thick; n=7 per condition) were prepared and maintained at 37°C for 48 h. Each specimen was weighed on a precision scale every 24 h until its mass was stable, at which time the initial mass was determined. Specimens (n=7) were then immersed in the solvent solutions and, after 48 h at 37°C, they were reweighed at 24- h intervals, until stabilization (final mass). The difference between the final and the initial mass determined the solvent capacity of each solvent. Data were subjected to analysis of variance and Tukey's test at 5% significance level. The results demonstrated that xylol was the most effective, especially on conventional gutta-percha and Resilon (p<0.05). Eucalyptol and orange oil were more effective on thermoplastic gutta-percha than the other materials (p<0.05). It was concluded that all evaluated substances presented solvent action, but xylol was the most effective on both gutta-percha or Resilon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article describes an orthodontic system used to obtain active continuous torque with movement control of both active and reactive units; the system relies on principles of the segmented technique. A cantilever system with .017 x .025-in beta-titanium alloy wire was designed to provide the desirable moment on the active unit. A transpalatal bar or a lingual arch increases the anchorage and neutralizes the side effects on the reactive unit. This technique is an efficient approach for major corrections of buccolingual inclinations of certain teeth. © 2010 American Association of Orthodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To verify the cleaning of the apical foramen and apical extrusion of dentin chips in single-rooted teeth instrumented with two techniques, one of which including the apical patency procedure. Method: Thirty teeth were internally stained with Indian ink, divided in two groups, of which only group I was subjected to apical patency. The dentin chips extruded through the apical foramen were collected in a glass receptacle and quantified. The apical foramen region was divided in quadrants and analyzed with a stereomicroscope to verify the action of the instrument on the cemental canal walls. The teeth were scored 0 4 according to the number of clean walls (without Indian ink), 0 corresponding to no clean wall. Results: In group I, there was no dentin plug, but only 1 tooth was scored 4. In group II, 10 teeth presented dentin plug and all of them were scored 0. There was no statistically significant difference between groups I and II regarding the extruded dentin mass (Scheffé test; p<0.05). Conclusion: The use of the apical patency procedure in single-rooted teeth does not modify the amount of dentin chips extruded through the apical foramen, does not produce an adequate cleaning of the cemental canal walls, but remove the plug of dentin chips from the cemental canal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the effectiveness of 3 solvents (Citrol orange oil, Eucalyptol and Tetrachloroethylene) and 2 associations of solvents (Citrol orange oil+Tetrachloroethylene and Eucalyptol+Tetrachloroethylene) on 3 types of gutta-percha (conventional, thermoplastic and EndoREZ) and Resilon. Ten discs (10 mm diameter x 1 mm thick) from each material were prepared using standard metallic molds. Each specimen was weighed to determinate its initial mass. The specimens were immersed in the solvents for 10 min, followed by immersion in distilled water for 20 min, and were then reweighed to obtain the final mass. The mean weight loss determined the solvent capacity. Data were analyzed by ANOVA and Tukey's test at 5% significance level. Tetrachloroethylene was the most effective on conventional gutta-percha (p<0.05). Tetrachloroethylene was also the most effective on thermoplastic gutta-percha, but it was not significantly different (p>0.05) from Eucalyptol+Tetrachloroethylene, Citrol+Tetrachloroethylene, and Citrol. All solvents and associations presented little effectiveness on Resilon. The association Eucalyptol+Tetrachloroethylene was the most effective on EndoREZ, but it did not differ significantly (p>0.05) from Citrol+Tetrachloroethylene and Tetrachloroethylene. All evaluated substances presented solvent action. Tetrachloroethylene improved the effectiveness of both Citrol and Eucalyptol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we report our achievements in the elaboration and optical characterizations of low-losses suspended core optical fibers elaborated from As2S3 glass. For preforms elaboration, alternatively to other processes like the stack and draw or extrusion, we use a process based on mechanical drilling. The drawing of these drilled performs into fibers allows reaching a suspended core geometry, in which a 2 μm diameter core is linked to the fiber clad region by three supporting struts. The different fibers that have been drawn show losses close to 0.9 dB/m at 1.55 μm. The suspended core waveguide geometry has also an efficient influence on the chromatic dispersion and allows its management. Indeed, the zero dispersion wavelength, which is around 5 μm in the bulk glass, is calculated to be shifted towards around 2μm in our suspended core fibers. In order to qualify their nonlinearity we have pumped them at 1.995 μm with the help of a fibered ns source. We have observed a strong non linear response with evidence of spontaneous Raman scattering and strong spectral broadening. © 2011 SPIE.