936 resultados para screening methods
Resumo:
Background In 2009 Malawi introduced a new protocol to screen potential blood donors for anaemia, using the WHO Haemoglobin Colour Scale (HCS) for initial screening. Published studies of the accuracy of the HCS to screen potential blood donors show varying levels of accuracy and opinion varies whether this is an appropriate screening test. The aim of the study was to assess the validity of the HCS, as a screening test, by comparison to HemoCue in potential blood donors in Malawi. Study design and Methods This was a blinded prospective study in potential blood donors aged over 18 years, at Malawi Blood Transfusion Service in Blantyre, Malawi. Capillary blood samples were analysed using the HCS and HemoCue, independent of each other. The sensitivity and specificity of correctly identifying ineligible blood donors (Hb≤12g/dL) were calculated. Results From 242 participants 234 (96.7%) were correctly allocated and 8 (3.3%), were wrongly allocated on the basis of the Haemoglobin Colour Scale (HCS) compared to HemoCue, all were subjects that were wrongly accepted as donors when their haemoglobin results were ≤12.0g/dL. This gave a sensitivity of 100% and specificity of 96.7% to detect donor eligibilty. The negative predictive value of the HCS was 100% but the positive predictive value to identify ineligible donors on the basis of anaemia was only 20%. Conclusions Initial screening with the HCS correctly predicts eligibility for blood donation in the majority of potential blood donors at considerable cost saving compared with use of HemoCue as the first line anaemia screening test, however, by this method a small number of anaemic patients were allowed to donate blood.
Resumo:
Background and aim: The usefulness of high definition colonoscopy plus i-scan (HD+i-SCAN) for average-risk colorectal cancer screening has not been fully assessed. The detection rate of adenomas and other measurements such as the number of adenomas per colonoscopy and the flat adenoma detection rate have been recognized as markers of colonoscopy quality. The aim of the present study was to compare the diagnostic performance of an HD+i-SCAN with that of standard resolution white-light colonoscope. Methods: This is a retrospective analysis of a prospectively collected screening colonoscopy database. A comparative analysis of the diagnostic yield of an HD+i-SCAN or standard resolution colonoscopy for average-risk colorectal screening was conducted. Results: During the period of study, 155/163 (95.1%) patients met the inclusion criteria. The mean age was 56.9 years. Sixty of 155 (39%) colonoscopies were performed using a HD+i-SCAN. Adenoma-detection-rates during the withdrawal of the standard resolution versus HD+i-SCAN colonoscopies were 29.5% and 30% (p = n.s.). Adenoma/colonoscopy values for standard resolution versus HD+i-SCAN colonoscopies were 0.46 (SD = 0.9) and 0.72 (SD = 1.3) (p = n.s.). A greater number of flat adenomas were detected in the HD+i-SCAN group (6/60 vs. 2/95) (p < .05). Likewise, serrated adenomas/polyps per colonoscopy were also higher in the HD+i-SCAN group. Conclusions: A HD+i-SCAN colonoscopy increases the flat adenoma detection rate and serrated adenomas/polyps per colonoscopy compared to a standard colonoscopy in average-risk screening population. HD+i-SCAN is a simple, available procedure that can be helpful, even for experienced providers. The performance of HD+i-SCAN and substantial prevalence of flat lesions in our average-risk screening cohort support its usefulness in improving the efficacy of screening colonoscopies.
Resumo:
The efficiency of current cargo screening processes at sea and air ports is unknown as no benchmarks exists against which they could be measured. Some manufacturer benchmarks exist for individual sensors but we have not found any benchmarks that take a holistic view of the screening procedures assessing a combination of sensors and also taking operator variability into account. Just adding up resources and manpower used is not an effective way for assessing systems where human decision-making and operator compliance to rules play a vital role. For such systems more advanced assessment methods need to be used, taking into account that the cargo screening process is of a dynamic and stochastic nature. Our project aim is to develop a decision support tool (cargo-screening system simulator) that will map the right technology and manpower to the right commodity-threat combination in order to maximize detection rates. In this paper we present a project outline and highlight the research challenges we have identified so far. In addition we introduce our first case study, where we investigate the cargo screening process at the ferry port in Calais.
Resumo:
Background and objective: Participation in colorectal cancer (CRC) screening varies widely among different countries and different socio-demographic groups. Our objective was to assess the effectiveness of three primary-care interventions to increase CRC screening participation among persons over the age of 50 years and to identify the health and socio-demographic-related factors that determine greater participation. Methods: We conducted a randomized experimental study with only one post-test control group. A total of 1,690 subjects were randomly distributed into four groups: written briefing; telephone briefing; an invitation to attend a group meeting; and no briefing. Subjects were evaluated 2 years post-intervention, with the outcome variable being participation in CRC screening. Results: A total of 1,129 subjects were interviewed. Within the groups, homogeneity was tested in terms of socio-demographic characteristics and health-related variables. The proportion of subjects who participated in screening was: 15.4% in the written information group (95% confidence interval [CI]: 11.2-19.7); 28.8% in the telephone information group (95% CI: 23.6-33.9); 8.1% in the face-to-face information group (95% CI: 4.5-11.7); and 5.9% in the control group (95% CI: 2.9-9.0), with this difference proving statistically significant (p < 0.001). Logistic regression showed that only interventions based on written or telephone briefing were effective. Apart from type of intervention, number of reported health problems and place of residence remained in the regression model. Conclusions: Both written and telephone information can serve to improve participation in CRC screening. This preventive activity could be optimized by means of simple interventions coming within the scope of primary health-care professionals.
Resumo:
African American women account for a disproportionate burden of cervical cancer incidence and mortality rate when compared to non-Hispanic White women. Cervical cancer is one of the most preventable types of cancer, and women can be screened for it with a routine Pap test. Given that religion occupies an essential place in African American lives, framing health messages with important spiritual themes and delivering them through a popular communication delivery channel may allow for a more culturally-relevant and accessible technology-based approach to promoting cervical cancer educational content to African American women. Using community-engaged research as a framework, the purpose of this multiple methods study was to develop, pilot test, and evaluate the feasibility, acceptability, and initial efficacy of a spiritually-based SMS text messaging intervention to increase cervical cancer awareness and Pap test screening intention among African American women. The study recruited church-attending African American women ages 21-65 and was conducted in three phases. Phases 1 and 2 consisted of a series of focus group discussions (n=15), cognitive response interviews (n=8), and initial usability testing that were conducted to inform the intervention development and modifications. Phase 3 utilized a non-experimental one-group pretest-posttest design to pilot test the 16-day text messaging intervention (n=52). Of the individuals enrolled, forty-six completed the posttest (retention rate=88%). Findings provided evidence for the early feasibility, high acceptability, and some initial efficacy of the CervixCheck intervention. There were significant pre-post increases observed for knowledge about cervical cancer and the Pap test (p = .001) and subjective norms (p = .006). Additionally, results post-intervention revealed that 83% of participants reported being either “satisfied” or “very satisfied” with the program and 85% found the text messages either “useful” or “very useful”. 85% of the participants also indicated that they would “likely” or “very likely” share the information they learned from the intervention with the women around them, with 39% indicating that they had already shared some of the information they received with others they knew. A spiritually-based SMS text messaging intervention could be a culturally appropriate and cost-effective method of promoting cervical cancer early detection information to African American women.
Resumo:
Introduction: Hospital malnutrition risk has prevalence values of 20%-50%, and it is a major health problem in the health institutions worldwide. Objective: To assess the accomplishment of nutritional screening and the prevalence of hospital malnutrition risk in a University Hospital. Materials and methods: A retrospective analysis was carried out with nutritional screening, using primary data from six clinical areas obtained in the period between July 2012 and December 2013. According to previous results in Mexican health institutions and considering a mean malnutrition risk prevalence of 50%, it was calculated that a sample size of 3200 subjects was required for the assessment of valid risk values. Patients with values ≥3 on the Nutritional Risk Screening (NRS, 2002) were classiied as carriers of nutritional risk. Results: A total of 5611 patients (38% of all patients admitted) were studied. The rate of screening declined from 55% in 2012 to 31% in 2013. During the whole period, 3034 patients were classiied with risk of malnutrition (54% prevalence). Conclusions: The prevalence of hospital malnutrition risk was high. The accomplishment of the nutritional screening was deicient, and declined between 2012 and 2013. The lack of nutritional screening does not meet the vital care requirements of hospitalized patients and prevents the timely treatment of those at malnutrition risk.
Resumo:
Background: Incidence of jaundice is high in newborn infants. Since well appearing newborns are rapidly and routinely discharged from hospital, performing an inexpensive noninvasive pre-discharge screening test for evaluation of jaundice seems to be necessary. Objectives: This study was conducted to compare the accuracy of cutaneous v/s serum bilirubin measurements in this regard. Patients and Methods: This was a prospective cross sectional study conducted in Mahdieh hospital, Tehran. 613 neonates weighing ≥ 1,800 g with gestational age of ≥ 35 weeks were enrolled. A pre discharge transcutaneous bilirubin test (TcB) was performed in all. Serum samples were taken from neonates with TcB ≥ 5 mg/dL in first and > 8 mg/dL in second 24 hours. Decision for treatment or recheck of bilirubin level after discharge was made based on serum bilirubin results. Results: Based on the study protocol, among 613 studied neonates, 491 (80%) revealed high TcB, of them 240 (49%) cases showed TBC ≥ 5 mg/dL in first and 251 (51 %) in second pre-discharge 24 hours. TcB ranged 3.3 - 17.1, mean TcB in first 24 hours was 6.9 ± 1 .7 (mode 6) and in second 24 hours 9.1 ± 2.1 (mode 10). Of 491 neonates with high TcB, capillary serum sample was taken as the second step and 398 neonates revealed high total serum bilirubin (TsB) with the same protocol for TcB. 108 (27.1%) neonates showed TsB ≥ 5 mg/dL in first and 290 (72.9%) in second 24 hours. According to the study results TcB has a 81% positive predictive value (PPV) in diagnosis of hyperbilirubinemia. Correlation coefficient of TcB and TsB in highest rate is equal to 72% (P value < 0.001). Conclusions: TcB is an inexpensive, noninvasive and precise pre-discharge screening test for evaluation of hyperbilirubinemia, with a high PPV. It is highly recommended to be performed routinely due to high incidence of hyperbilirubinemia in neonates.
Resumo:
Purpose: To investigate the phytochemistry and cytotoxic activity of stem bark extracts from Genus dolichocarpa and Duguetia chrysocarpa - two species of the Annonaceae family. Methods: The crude ethanol bark extracts (EtOH) of the plants were obtained by maceration. The crude extracts were suspended in a mixture of methanol (MeOH) and water (H2O) (proportion 3:7 v/v) and partitioned with hexane, chloroform (CHCl3) and ethyl acetate (AcOEt) in ascending order of polarity to obtain the respective fractions. The extracts were evaluated on thin layer chromatography (TLC) plates of silica gel to highlight the main groups of secondary metabolites. Cytotoxicity was tested against human tumor cell lines - OVCAR-8 (ovarian), SF-295 (brain) and HCT-116 (colon) - using 3- (4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) assay. Results: The screening results demonstrated that all the extracts were positive for the presence of flavonoids and tannins. The presence of alkaloids also was detected in some extracts. The hexane extract of A. dolichocarpa showed the strongest cytotoxicity against HCT-116 with cell growth inhibition of 89.02 %. Conclusion: The findings demonstrate for the first time the cytotoxic activity of the extracts of A. dolichocarpa and D. chrysocarpa, thus providing some evidence that plants of the Annonaceae family are a source of active secondary metabolites with cytotoxic activity.
Resumo:
Purpose: Colorectal cancer (CRC) is among the top five cancers afflicting both men and women globally. Once predominantly a Western disease, it has begun to rise in Asian countries as well. This systematic review aims to compile and analyze the various barriers towards colorectal cancer screening in Asia, and to determine if the barriers are consistent throughout the continent. Methods: Article Inclusion criteria for based on year of publication from year 2008 till 2015, has been conducted in Asia, and written in English language. A total of 23 studies were included in this review, chosen via primary search of journal websites and databases, and a secondary search through the reference lists of eligible articles. Results: It was found that major barriers of colorectal cancer screening are; poor education/knowledge, negative perceptions towards screening, aversion to test results, financial constraints, time constraints, lack of physicians’ recommendation, limited/difficult access to screening locations, fatalistic beliefs, low perceived risks, language barriers, confidence in traditional medicine/distrust in Western medicine, ignorance and old age. Conclusion: Lack of knowledge/education is the most critical barrier that is linked to a majority of other barriers that can hinder a person from undergoing CRC screening for early prevention, detection and treatment. Majority of these barriers encountered regarding the poor rates of CRC screening are similar across countries in Asia.
Management and outcome of cholesterol embolus identified in a diabetic retinopathy screening program
Resumo:
Purpose. We examined the incidence, management, and outcomes of patients known to be at high cardiovascular risk, and to assess whether specialist referral to an ophthalmic medical clinic is worthwhile. Methods. Patients in the East Birmingham area with cholesterolembolus who were identified on digital diabetic retinopathy screening over a 3-year period were referred to a specialist ophthalmic medicine clinic within Heart of England NHS Trust for management and investigation. Results. A total of 33 patients were referred for clinical management.(male:female = 22:11, mean age 72 years). A total of 28 patients were known to be receiving medication: 14 anti hypertensive therapy(42%), 19 aspirin (59%), and 21 statin (64%). A total of 18 patients had known cardiovascular disease, 10 of whom had received carotid stenting or coronary artery bypass surgery. Ten patients diagnosed with embolus required and consented to carotid Doppler studies. Six patients were confirmed with significant carotid stenosis and 2 (6%)of these patients required carotid endarterectomy surgery. Overall, 4patients died, a mortality rate of 12% over 3 years. Conclusions. Annual diabetic retinopathy screening provide sopportunistic identification of asymptomatic cholesterol emboli and provides an opportunity for review of medical management in the high-risk patient group with appropriate identification and referral for carotid stenosis surgery. A total of 11 patients were identified with sub optimal cardiovascular risk management: e.g., statin use.
Resumo:
Stroke stands for one of the most frequent causes of death, without distinguishing age or genders. Despite representing an expressive mortality fig-ure, the disease also causes long-term disabilities with a huge recovery time, which goes in parallel with costs. However, stroke and health diseases may also be prevented considering illness evidence. Therefore, the present work will start with the development of a decision support system to assess stroke risk, centered on a formal framework based on Logic Programming for knowledge rep-resentation and reasoning, complemented with a Case Based Reasoning (CBR) approach to computing. Indeed, and in order to target practically the CBR cycle, a normalization and an optimization phases were introduced, and clustering methods were used, then reducing the search space and enhancing the cases re-trieval one. On the other hand, and aiming at an improvement of the CBR theo-retical basis, the predicates` attributes were normalized to the interval 0…1, and the extensions of the predicates that match the universe of discourse were re-written, and set not only in terms of an evaluation of its Quality-of-Information (QoI), but also in terms of an assessment of a Degree-of-Confidence (DoC), a measure of one`s confidence that they fit into a given interval, taking into account their domains, i.e., each predicate attribute will be given in terms of a pair (QoI, DoC), a simple and elegant way to represent data or knowledge of the type incomplete, self-contradictory, or even unknown.
Resumo:
Advanced cell cultures are developing rapidly in biomedical research. Nowadays, various approaches and technologies are being used, however, these culturing systems present limitations from increasing complexity, requiring high costs, and not easily customization. We present two versatile and cost-effective methods for developing culturing systems that integrate 3D cell culture and microfluidic platforms. Firstly, for drug screening applications, many high-quality cell spheres of homogeneous size and shape are required. Conventional approaches usually have a dearth of control over the size and geometry of cell spheres and require sample collection and manipulation. To overcome this difficulty, in this study, hundreds of spheroids of several cell lines were generated using multi-well plates that housed our microdevices. Tumor spheroids grow at a uniform rate (in scaffolded or scaffold-free environments) and can be harvested at will. Microscopy imaging are done in real time during or after the culture. After in situ immunostaining, fluorescence imaging can be conducted while keeping the spatial distribution of spheroids in the microwells. Drug effects were successfully observed through viability, growth, and morphologic investigations. Also, we fabricated a microfluidic device suitable for directed and selective cell culture treatments. The microfluidic device was used to reproduce and confirm in vitro investigations carried out using normal culture methods, using a microglia cell line. The device layout and the syringe pump system, entirely designed in our lab, successfully allowed culture growth and medium flow regulation. Solution flows can be finely controlled, allowing treatments and immunofluorescence in one single chamber selectively. To conclude, we propose the development of two culturing platforms (microstructured well devices and in-flow microfluidic chip), which are the result of separate scientific investigations but have the primary goal of performing treatments in a reproducible manner. Our devices shall improve future studies on drug exposure testing, representing adjustable and versatile cell culture systems.
Resumo:
In this Ph.D. project, original and innovative approaches for the quali-quantitative analysis of abuse substances, as well as therapeutic agents with abuse potential and related compounds were designed, developed and validated for application to different fields such as forensics, clinical and pharmaceutical. All the parameters involved in the developed analytical workflows were properly and accurately optimised, from sample collection to sample pretreatment up to the instrumental analysis. Advanced dried blood microsampling technologies have been developed, able of bringing several advantages to the method as a whole, such as significant reduction of solvent use, feasible storage and transportation conditions and enhancement of analyte stability. At the same time, the use of capillary blood allows to increase subject compliance and overall method applicability by exploiting such innovative technologies. Both biological and non-biological samples involved in this project were subjected to optimised pretreatment techniques developed ad-hoc for each target analyte, making also use of advanced microextraction techniques. Finally, original and advanced instrumental analytical methods have been developed based on high and ultra-high performance liquid chromatography (HPLC,UHPLC) coupled to different detection means (mainly mass spectrometry, but also electrochemical, and spectrophotometric detection for screening purpose), and on attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) for solid-state analysis. Each method has been designed to obtain highly selective, sensitive yet sustainable systems and has been validated according to international guidelines. All the methods developed herein proved to be suitable for the analysis of the compounds under investigation and may be useful tools in medicinal chemistry, pharmaceutical analysis, within clinical studies and forensic investigations.
Resumo:
Objective: Liver transplantation has been associated with a high prevalence of osteoporosis, although most data rely on single-center studies with limited sample size, with most of them dating back to late 1990s and early 2000s. The present thesis aims to assess the prevalence of fragility fractures and contributing factors in a large modern cohort of liver transplant recipients managed in a referral Italian Liver Transplant Center. Design and Methods: Paper and electronic medical records of 429 consecutive patients receiving liver transplantation from 1/1/2010 to 31/12/2015 were reviewed, and 366 patients were selected. Clinically obtained electronic radiological images within 6 months from the date of liver transplant surgery, such as lateral views of spine X-rays or CT abdominal scans, were opportunistically reviewed in a blinded fashion to screen for morphometric vertebral fractures. Clinical fragility fractures reported in the medical records, along with information on etiology of cirrhosis and biochemistries at the time of liver surgery were also recorded. Results: Prevalence of fragility fractures in the whole cohort was 155/366 (42.3%), with no significant differences between sexes. Of patients with fractures, most sustained vertebral fractures (145/155, 93.5%), the majority of which were mild or moderate wedges. Multiple vertebral fractures were common (41.3%). Fracture rates were similar across different etiologies of cirrhosis and were also comparable in patients with diabetes or exposed to glucocorticoids. Kidney function was significantly worse in women with fractures. Independent of age, sex, alcohol use, eGFR, etiology of liver disease, lower BMI was the only independent risk factor for fractures (adjusted OR 1,058, 95%CI 1,001-1,118, P=0.046) in this study population. Conclusions: A considerable fracture burden was shown in a large and modern cohort of liver transplant recipients. Given the remarkably high prevalence of fractures, a metabolic bone disease screening should be implemented in every patient awaiting liver transplantation.
Resumo:
Diabetic Retinopathy (DR) is a complication of diabetes that can lead to blindness if not readily discovered. Automated screening algorithms have the potential to improve identification of patients who need further medical attention. However, the identification of lesions must be accurate to be useful for clinical application. The bag-of-visual-words (BoVW) algorithm employs a maximum-margin classifier in a flexible framework that is able to detect the most common DR-related lesions such as microaneurysms, cotton-wool spots and hard exudates. BoVW allows to bypass the need for pre- and post-processing of the retinographic images, as well as the need of specific ad hoc techniques for identification of each type of lesion. An extensive evaluation of the BoVW model, using three large retinograph datasets (DR1, DR2 and Messidor) with different resolution and collected by different healthcare personnel, was performed. The results demonstrate that the BoVW classification approach can identify different lesions within an image without having to utilize different algorithms for each lesion reducing processing time and providing a more flexible diagnostic system. Our BoVW scheme is based on sparse low-level feature detection with a Speeded-Up Robust Features (SURF) local descriptor, and mid-level features based on semi-soft coding with max pooling. The best BoVW representation for retinal image classification was an area under the receiver operating characteristic curve (AUC-ROC) of 97.8% (exudates) and 93.5% (red lesions), applying a cross-dataset validation protocol. To assess the accuracy for detecting cases that require referral within one year, the sparse extraction technique associated with semi-soft coding and max pooling obtained an AUC of 94.2 ± 2.0%, outperforming current methods. Those results indicate that, for retinal image classification tasks in clinical practice, BoVW is equal and, in some instances, surpasses results obtained using dense detection (widely believed to be the best choice in many vision problems) for the low-level descriptors.