974 resultados para resonant push-pull
Resumo:
As nuclear magnetic resonance imaging and spectroscopy move inexorably toward higher field-strength magnets in search of improved signal-to-noise ratio, spectral resolution, and spatial resolution, the way in which radiofrequency (RF) probes are designed changes. At higher frequencies, resonant cavities become the favored RF ''coil'' type and may be built using streamline elements to reduce the inductance of the system. In modeling such systems, the quasi-static approach of assuming that current flows evenly in all conductor cross sections and that adjacent conductors do not affect each other becomes less reasonable. The proximity of RF conductors in resonators typically causes RF eddy currents to flow, whereby the current density in each rung is altered by the RF fields generated by nearby conductors. The proper understanding and prediction of how resonators will perform require a model of the current densities flowing in conducting sections, including all RF eddy current effects. Very few models of this type have been presented in the literature. This article presents an overview of one such model and of how it may be applied to a variety of resonators, both shielded and unshielded, circular, and elliptical, in cross section. Results are presented from a shielded head coil operating at 2 tesla. (C) 1997 John Wiley & Sons, Inc.
Resumo:
We have developed a sensitive resonant four-wave mixing technique based on two-photon parametric four-wave mixing with the addition of a phase matched ''seeder'' field. Generation of the seeder field via the same four-wave mixing process in a high pressure cell enables automatic phase matching to be achieved in a low pressure sample cell. This arrangement facilitates sensitive detection of complex molecular spectra by simply tuning the pump laser. We demonstrate the technique with the detection of nitric oxide down to concentrations more than 4 orders of magnitude below the capability of parametric four-wave mixing alone, with an estimated detection threshold of 10(12) molecules/cm(3).
Resumo:
Background. We aimed at investigating the influence of diabetic neuropathy and previous history of plantar ulcers on electromyography (EMG) of the thigh and calf and on vertical ground reaction forces during gait. Methods. This study involved 45 adults divided into three groups: a control group (n = 16), diabetic neuropathic group (n = 19) and diabetic neuropathic group with previous history of plantar ulceration (it = 10). EMG of the right vastus lateralis, lateral gastrocnemius and tibialis anterior were studied during the stance phase. The peaks and time of peak occurrence were determined and a co-activation index between tibialis anterior and lateral gastrocnemius. In order to represent the effect of the changes in EMG, the first and second peaks and the minimum value of the vertical ground reaction force were also determined. Inter-group comparisons of the electromyographical and ground reaction forces variables were made using three MANCOVA (peaks and times of EMG and peaks of force) and one ANCOVA (co-activation index). Findings. The ulcerated group presented a delayed in the time of the lateral gastrocnemius and vastus lateralis peak occurrence in comparison to control`s. The lateral gastrocnemius delay may be related to the lower second vertical peak in diabetic subjects. However, the delay of the vastus lateralis did not cause any significant change on the first vertical peak. Interpretations. The vastus lateralis and lateral gastrocnemius delay demonstrate that ulcerated diabetic neuropathic patients have a motor deficit that could compromise their ability to walk, which was partially confirmed by changes on ground reaction forces during the push-off phase. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The time evolution of the populations of the collective states of a two-atom system in a squeezed vacuum can exhibit quantum beats. We show that the effect appears only when the carrier frequency of the squeezed field is detuned from the atomic resonance. Moreover, we find that the quantum beats are not present for the case in which the two-photon correlation strength is the maximum possible for a field with a classical analog. We also show that the population inversion between the excited collective states, found for the resonant squeezed vacuum, is sensitive to the detuning and the two-photon correlations. For large detunings or a field with a classical analog there is no inversion between the collective states. Observation of the quantum beats or the population inversion would confirm the essentially quantum-mechanical nature of the squeezed vacuum. (C) 1997 Optical Society of America.
Resumo:
The aim of this study was to determine the contribution of preoperative gastric secretory and hormonal response, to the appearance of Barrett`s esophagus in the esophageal stump following subtotal esophagectomy. Thirty-eight end-stage chagasic achalasia patients submitted to esophagectomy and cervical gastric pull-up were followed prospectively for a mean of 13.6 +/- 9.2 years. Gastric acid secretion, pepsinogen, and gastrin were measured preoperatively in 14 patients who have developed Barrett`s esophagus (Group I), and the results were compared to 24 patients who did not develop Barrett`s esophagus (Group II). In the group (I), the mean basal and stimulated preoperative gastric acid secretion was significantly higher than in the group II (basal: 1.52 vs. 1.01, p = 0.04; stimulated: 20.83 vs. 12.60, p = 0.01). Basal and stimulated preoperative pepsinogen were also increased at the Group I compared to Group II (Basal = 139.3 vs. 101.7, p = 0.02; stimulated = 186.0 vs. 156.5, p = 0.07. There was no difference in preoperative gastrin between the two groups. Gastritis was present during endoscopy in 57.1% of the Group I, while it was detected in 16.6% of the Group II, p = 0.014. Barrett`s esophagus in the esophageal stump was associated to high preoperative levels of gastric acid secretion, serum pepsinogen, and also gastritis in the transposed stomach.
Resumo:
P>Achalasia surgical treatment alters the esophagogastric junction anatomy (cardiomyotomy plus fundoplication or esophagectomy and gastric pull-up), thus favoring a certain degree of gastroesophageal reflux. Gastric secretory and hormonal functioning is not completely known in chagasic patients. The aim of this study was to evaluate the gastric secretory and hormonal response in patients with end-stage chagasic achalasia compared with normal subjects. Gastric secretion and hormonal response were assessed by estimation of gastric acid secretion (GAS) in basal condition and after pentagastrin stimulation, basal serum gastrin, and serum pepsinogen (SP) in basal condition and after betazole hydrochloride (Histalog (R); Eli Lilly and Company, Indianapolis, IN, USA) stimulation in 27 patients with chagasic achalasia. The results were then compared with those of 24 normal subjects. In the chagasic group, the mean basal and stimulated GAS were significantly lower than in the control group (basal: 1.277 vs. 3.13, P = 0.002; stimulated: 15.9 vs. 35.8, P = 0.0001). Chagasic patients` SG levels showed a significantly higher basal value than the control group (83.3 vs. 36.8, P = 0.0001). There was a significant increase of SP after stimulation compared with the basal levels in both chagasic and control groups. Although the chagasic patients` SP values were higher than the controls, this difference was not statistically significant, either in basal and stimulated conditions (basal: 122.0 vs. 108.9, stimulated 120 min: 177.1 vs. 158.9). In patients with chronic Chagas` disease (ChD), although autonomic denervation does not suppress the strength of the gastric mucosal cells` secretory response to stimulation, it reduces GAS (parietal cell) without, however, affecting SP production (chief cells). On the other hand, the gastrin-producing cells have continuously been stimulated by low GAS.
Resumo:
Background: The purpose of this study was to investigate the ankle range of motion during neuropathic gait and its influence on plantar pressure distribution in two phases during stance: at heel-strike and at push-off. Methods: Thirty-one adults participated in this study (control group, n = 16; diabetic neuropathic group, n = 15). Dynamic ankle range of motion (electrogoniometer) and plantar pressures (PEDAR-X system) were acquired synchronously during walking. Plantar pressures were evaluated at rearfoot. midfoot and forefoot during the two phases of stance. General linear model repeated measures analysis of variance was applied to investigate relationships between groups, areas and stance phases. Findings: Diabetic neuropathy patients walked using a smaller ankle range of motion in stance phase and smaller ankle flexion at heel-strike (P = 0.0005). Peak pressure and pressure-time integral values were higher in the diabetic group in the midfoot at push-off phase when compared to heel-strike phase. On the other hand, the control group showed similar values of peak pressure in midfoot during both stance phases. Interpretation: The ankle mobility reduction observed could be associated to altered plantar pressure distribution observed in neuropathic subjects. Results demonstrated that midfoot and forefoot play a different role in subjects with neuropathy by receiving higher loads at push-off phase that are probably due to smaller ankle flexion at stance phase. This may explain the higher loads in anterior areas of the foot observed in diabetic neuropathy subjects and confirm an inadequate foot rollover associated to the smaller ankle range of motion at the heel-strike phase. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
The purpose is to present the studies of RET gene expression and acetylcholinesterase activity in 23 patients operated for Hirschsprung`s disease (HD). The patients underwent either transanal endorectal pull-through or Duhamell`s procedure. Full-thickness intestinal samples from the three different segments (ganglionic, intermediate and aganglionic) were collected. Each tissue sample was divided in two portions, one for AChE histochemical staining and the other for examination of RET mRNA expression level. All patients had an uneventful postoperative recovery. In all patients, the AChE stainings demonstrated the absence of activity in the ganglionic area, the marked increase of positive fibers in the aganglionic area, and little increase of positive fibers in the intermediate area. In the ganglionic and intermediate areas, all patients (100%) showed significant RET gene expression. In the aganglionic area, 18 patients (78.3%) did not present gene expression and the other five patients (21.7%) presented gene expression that was similar to the ganglionic and intermediate areas. The results reinforce the conclusion that the method of AChE staining is effective for the diagnosis of intestinal aganglionosis and confirm the knowledge that genes beyond RET may be implicated in the genesis of sporadic cases of HD.
Resumo:
We report a very unusual case of murder of a 4-year-old male white child who died of asphyxiation. Asphyxia occurred due to 3 factors: manual strangulation, hyperextension of the neck, and atlantoaxial subluxation. The offenses were carried out by a single assailant (the stepfather of the child) who strangled the child with his right hand, using his left hand to pull the hair of the child, forcing the head back and causing hyperextension of the neck, thereby dislocating the first and second cervical vertebrae.
Resumo:
The purpose of the present study was to evaluate the intra and interday reliability of surface electromyographic amplitude values of the scapular girdle muscles and upper limbs during 3 isometric closed kinetic chain exercises, involving upper limbs with the fixed distal segment extremity on stable base of support and on a Swiss ball (relatively unstable). Twenty healthy adults performed the exercises push-up, bench-press and wall-press with different effort levels (80% and 100% maximal load). Subjects performed three maximal voluntary contractions (MVC) in muscular testing position of each muscle to obtain a reference value for root mean square (RMS) normalization. Individuals were instructed to randomly perform three isometric contraction series, in which each exercise lasted 6 s with a 2-min resting-period between series and exercises. Intra and interday reliabilities were calculated through the intraclass correlation coefficient (ICC 2.1), standard error of the measurement (SEM). Results indicated an excellent intraday reliability of electromyographic amplitude values (ICC >= 0.75). The interday reliability of normalized RMS values ranged between good and excellent (ICC 0.52-0.98). Finally, it is suggested that the reliability of normalized electromyographic amplitude values of the analyzed muscles present better values during exercises on a stable surface. However, load levels used during the exercises do not seem to have any influence on variability levels, possibly because the loads were quite similar. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
We assess the effects of chemical processing, ethylene oxide sterilization, and threading on bone surface and mechanical properties of bovine undecalcified bone screws. In addition, we evaluate the possibility of manufacturing bone screws with predefined dimensions. Scanning electronic microscopic images show that chemical processing and ethylene oxide treatment causes collagen fiber amalgamation on the bone surface. Processed screws hold higher ultimate loads under bending and torsion than the in natura bone group, with no change in pull-out strength between groups. Threading significantly reduces deformation and bone strength under torsion. Metrological data demonstrate the possibility of manufacturing bone screws with standardized dimensions.
Resumo:
The purpose of this study was to compare SEMG activities during axial load exercises on a stable base of support and on a medicine ball (relatively unstable). Twelve healthy male volunteers were tested (x = 23 +/- 7y). Surface EMG was recorded from the biceps brachii, anterior deltoid, clavicular portion of pectoralis major, upper trapezius and serratus anterior using surface differential electrodes. All SEMG data are reported as percentage of RMS mean values obtained in maximal voluntary contractions for each muscle studied. A 3-way within factor repeated measures analysis of variance was performed to compare RMS normalized values. The RMS normalized values of the deltoid were always greater during the exercises performed on a medicine ball in relation to those performed on a stable base of support. The trapezius showed greater mean electric activation amplitude values on the wall-press exercise on a medicine ball, and the pectoralis major on the push-up. The serratus and biceps did not show significant differences of electric activation amplitude in relation to both tested bases of support. Independent of the base of support, none of the studied muscles showed significant differences of electric activation amplitude during the bench-press exercise. The results contribute to the identification of the levels of muscular activation amplitude during exercises that are common in clinical practice of rehabilitation of the shoulder and the differences in terms of type of base of support used. (C) 2006 Elsevier Ltd. All rights reserved.
Resumo:
STUDY DESIGN: Controlled laboratory study. OBJECTIVE: To assess the activation of 7 shoulder muscles under 2 closed kinetic chain (CKC) tasks for the upper extremity using submaximal isometric effort, thus providing relative quantification of muscular isometric effort for these muscles across the CKC exercises, which may be applied to rehabilitation protocols for individuals with shoulder weakness. BACKGROUND: CKC exercises favor joint congruence, reduce shear load, and promote joint dynamic stability. Additionally, knowledge about glenohumeral and periscapular muscle activity elicited during CKC exercises may help clinicians to design protocols for shoulder rehabilitation. METHODS: Using surface electromyography, activation level was measured across 7 shoulder muscles in 20 healthy males, during the performance of a submaximal isometric wall press and bench press. Signals were normalized to the maximal voluntary isometric contraction, and, using paired t tests, data were analyzed between the exercises for each muscle. RESULTS: Compared to the wall press, the bench press elicited higher activity for most muscles, except for the upper trapezius. Levels of activity were usually low but were above 20% maximal voluntary isometric contraction for the serratus anterior on both tasks, and for the long head triceps brachii on the bench press. CONCLUSIONS: Both the bench press and wall press, as performed in this study, led to relatively low EMG activation levels for the muscles measured and may be considered for use in the early phases of rehabilitation. J Ort hop Sports Phys Ther 2011;41(7):520-525, Epub 2 February 2011. doi:10.2519/jospt.2011.3418
Resumo:
Inflammatory responses have been described as occurring after exposure to some latex materials. In this study pro-inflammatory activity in the latex of Cryptostegia grandiflora was investigated. The soluble proteins of the latex (CgLP) were isolated from the whole latex and evaluated by in vivo assays. CgLP induced strong inflammatory activity mediated by neutrophil migration, enlarging vascular permeability and increasing myeloperoxidase activity locally in rats. CgLP-induced inflammation was observed in peritonitis, paw edema and air push models. In addition, CgLP caused hyperemia in a healing model. The peritonitis effect was lost when CgLP was previously boiled suggesting the involvement of proinflammatory proteins. Thioglycollate increased the neutrophil migration induced by CgLP, but not by fMLP Mast cell depletion provoked by 40/80 compound did not modify the course of inflammation triggered by CgLP, being similar to fMLP, which suggested that neutrophil migration was induced by direct mechanism mediated by macrophages. Neutrophil migration stimulated by CgLP was strongly inhibited by Dexamethasone and to a lesser extent by Thalidomide, indicating the involvement of cytokines in mediating neutrophil infiltration. Celecoxib and Indomethacin were inhibitory suggesting the involvement of prostaglandins. Cimetidine was effective only in the initial phase of edema. PCA 4248 was ineffective. It is concluded that the latex of C. grandiflora is a potent inflammatory fluid, and also that laticifer proteins may be implicated in this process. (c) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Objective. The aim of this study was to compare GPX instruments and hand files for gutta-percha removal. Study design. Fifty maxillary central incisors with a single straight canal were instrumented and filled. The teeth were divided into 5 groups of 10 specimens each, according to the gutta-percha removal techniques: group 1: GPX (21-mm-long teeth); group 2: GPX and xylol as solvent (21-mm-long teeth); group 3: GPX (25-mm-long teeth); group 4: GPX and xylol as solvent (25-mm-long teeth); and group 5: hand files and xylol as solvent. The amount of time for gutta-percha removal and the number of fractured instruments were evaluated. Radiographs were taken, and the teeth were grooved longitudinally and split. The area of residual debris was measured using Sigma Scan software. Results. The time for filling material removal was significantly shorter when GPX was used (P < .05). Overall, hand files and solvent produced fewer remnants of filling materials (P < .05). In the GPX 25 mm-long teeth group, the filling material was not removed in the apical third. Conclusions. Under the experimental conditions, the GPX instruments proved to be faster than hand instruments in removing root filling materials; however, hand instruments left a smaller amount of residual filling materials on the canal walls. The GPX instruments did not pull the gutta-percha beyond its tip. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 675-680)