995 resultados para radiographic apex


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To determine the interobserver reliability of radiologists' interpretations of mobile chest radiographs for nursing home-acquired pneumonia. Design: A cross-sectional reliability study. Setting: Nursing homes and an acute care hospital. Participants: Four radiologists reviewed 40 mobile chest radiographs obtained from residents of nursing homes who met a clinical definition of lower respiratory tract infections. Measurements: Radiologists were asked to interpret radiographs with respect to the film quality; presence, pattern, and extent of an infiltrate; and the presence of a pleural effusion or adenopathy. Interrater reliability was evaluated using the intraclass correlation coefficient derived from a 2-way random effects model. Results: On average the radiologists reported that 6 of the 40 films were of very good or excellent quality and 16 of the 40 were of fair or poor quality. When the finding of an infiltrate was dichotomized (0 = no; 1 = possible, probable, or definite) all 4 radiologists agreed on 21 of the 37 chest radiographs. The intraclass correlation coefficient for the presence or absence of infiltrates was 0.54 (95% confidence intervals [CI] 0.38 to 0.69). For the 14 radiographs where infiltrates were observed by all radiologists, intraclass correlation coefficients for the presence of pleural effusions was 0.08 (95% CI -0.10 to 0.41), hilar adenopathy 0.54 (95% CI 0.29 to 0.79), and mediastinal adenopathy 0.49 (95% CI 0.21 to 0.76). Conclusion: In conclusion, the interrater agreement among radiologists for mobile chest radiographs in establishing the presence or absence of an infiltrate can be judged to be "fair." Treatment decisions need to include clinical findings and should not be made based on radiographic findings alone. © 2006 American Medical Directors Association.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The feasibility of apertureless scanning near-field Raman microscopy, exploiting the local enhancement in Raman scattering in the vicinity of a silver or gold tip, was investigated. Using the finite difference time domain method we calculated the enhancement of electric field strength, and hence Raman scattering, achieved through the resonant excitation of local modes in the tip. By modelling the frequency-dependent dielectric response of the metal tip we were able to highlight the resonant nature of the tip-enhancement and determine the excitation wavelength required for the strongest electric field enhancement, and hence Raman scattering intensity, which occurs for the excitation of modes localized at the tip apex. It is demonstrated that a peak Raman enhancement of 10(7)-fold should be achievable with <5 nm spatial resolution. We show that surface-enhanced Raman scattering from carbon contamination on a silver or gold tip can be significant. However, we find for a tip of radius of curvature 20 nm that the Raman enhancement should decay totally within 20 nm from the tip. Hence withdrawal of the tip by this distance should lead to the disappearance of the tip-enhanced signal, leaving only that from carbon contamination on the tip itself and the intrinsic signal from the sample. Copyright (C) 2003 John Wiley Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was carried out to investigate whether the electronic portal imaging (EPI) acquisition process could be optimized, and as a result tolerance and action levels be set for the PIPSPro QC-3V phantom image quality assessment. The aim of the optimization process was to reduce the dose delivered to the patient while maintaining a clinically acceptable image quality. This is of interest when images are acquired in addition to the planned patient treatment, rather than images being acquired using the treatment field during a patient's treatment. A series of phantoms were used to assess image quality for different acquisition settings relative to the baseline values obtained following acceptance testing. Eight Varian aS500 EPID systems on four matched Varian 600C/D linacs and four matched Varian 2100C/D linacs were compared for consistency of performance and images were acquired at the four main orthogonal gantry angles. Images were acquired using a 6 MV beam operating at 100 MU min(-1) and the low-dose acquisition mode. Doses used in the comparison were measured using a Farmer ionization chamber placed at d(max) in solid water. The results demonstrated that the number of reset frames did not have any influence on the image contrast, but the number of frame averages did. The expected increase in noise with corresponding decrease in contrast was also observed when reducing the number of frame averages. The optimal settings for the low-dose acquisition mode with respect to image quality and dose were found to be one reset frame and three frame averages. All patients at the Northern Ireland Cancer Centre are now imaged using one reset frame and three frame averages in the 6 MV 100 MU min(-1) low-dose acquisition mode. Routine EPID QC contrast tolerance (+/-10) and action (+/-20) levels using the PIPSPro phantom based around expected values of 190 (Varian 600C/D) and 225 (Varian 2100C/D) have been introduced. The dose at dmax from electronic portal imaging has been reduced by approximately 28%, and while the image quality has been reduced, the images produced are still clinically acceptable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since the financial crash of 2008 monetary policy has been in a state of stasis – a condition in which things are not changing, moving, or progressing, but rather appear frozen. Interest rates have been frozen at low levels for a considerable period time. Inflation targets have consistently been missed, through phases of both overshooting and undershooting. At the same time, a variety of unconventional monetary policies involving asset purchases and liquidity provision have been pursued. Questions have been raised from a variety of sources, including various international organizations, covering distinct BIS and IMF positions about the continuing validity and sustainability of existing monetary policy frameworks, not least because inflation targeting has ceased to act as reliable guide for policy for over six years. Despite this central banks have been reluctant to debate moving to a new formal policy framework. This article argues that as an apex policy forum only the G20 leaders’ summits has the necessary political authority to call their central banks to account and initiate a wide ranging debate on the future of monetary policy. A case is made for convening a monetary policy working group to discuss a range of positions, including those of the BIS and IMF, and to make recommendations, because the G20 has been most effective in displaying international financial leadership, when leaders have convened and made use of specialist working groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dental Panoramic Tomography (DPT) is a widely used and valuable examination in dentistry. One area prone to artefacts and therefore misinterpretation is the anterior region of the mandible. This case study discusses a periapical radiolucency related to lower anterior teeth that is discovered to be a radiographic artefact. Possible causes of the artefact include a pronounced depression in the mental region of the mandible or superimposition of intervertebral spaces. Additional limitations of the DPT image include superimposition of radio-opaque structures, reduced image detail compared to intra-oral views and uneven magnification. These problems often make the DPT inappropriate for imaging the anterior mandible.

CLINICAL RELEVANCE: Panoramic radiography is often unsuitable for radiographic examination of the anterior mandible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The first Australian palliative care nurse practitioner (NP) was endorsed in 2003. In 2009 the Victoria Department of Health funded the development of the Victorian Palliative Care Nurse Practitioner Collaborative (VPCNPC). Its aim was to promote the NP role, develop resources, and provide education and mentorship to NPs, nurse practitioner candidates (NPCs), and health service managers. Four key objectives were developed: identify the demographic profile of palliative care NPCs in Victoria; develop an education curriculum and practical resources to support the training and education of palliative care NPCs and NPs; provide mentorship to NPs, NPCs, and service managers; and ensure effective communication with all key stakeholders. An NPC survey was also conducted to explore NPC demographics, models of care, the hours of study required for the role, the mentoring process, and education needs. This paper reports on the establishment of the VPCNPC, the steps taken to achieve its objectives, and the results of the survey. The NP role in palliative care in Australia continues to evolve, and the VPCNPC provides a structure and resources to clearly articulate the benefits of the role to nursing and clinical services. The advanced clinical practice role of the nurse practitioner (NP) has been well established in North America for several decades and across a range of specialties (Ryan-Woolley et al, 2007; Poghosyan et al, 2012). The NP role in Australia and the UK is a relatively new initiative that commenced in the early 2000s (Gardner et al, 2009). There are over 1000 NPs across all states and territories of Australia, of whom approximately 130 work in the state of Victoria (Victorian Government Health Information, 2012). Australian NPs work across a range of specialties, including palliative, emergency, older person, renal, cardiac, respiratory, and mental health care. There has been increasing focus nationally and internationally on developing academic programmes specifically for nurses working toward NP status (Gardner et al, 2006). There has been less emphasis on identifying the comprehensive clinical support requirements for NPs and NP candidates (NPCs) to ensure they meet all registration requirements to achieve and/or maintain endorsement, or on articulating the ongoing requirements for NPs once endorsed. Historically in Australia there has been a lack of clarity and limited published evidence on the benefits of the NP role for patients, carers, and health services (Quaglietti et al, 2004; Gardner and Gardner, 2005; Bookbinder et al, 2011; Dyar et al, 2012). An NP is considered to be at the apex of clinical nursing practice. The NP role typically entails comprehensively assessing and managing patients, prescribing medicines, making direct referrals to other specialists and services, and ordering diagnostic investigations (Australian Nursing and Midwifery Council, 2009). All NPs in Australia are required to meet the following generic criteria: be a registered nurse, have completed a Nursing and Midwifery Board of Australia approved postgraduate university Master's (nurse practitioner) degree programme, and be able to demonstrate a minimum of 3 years' experience in an advanced practice role (Nursing and Midwifery Board of Australia, 2011). An NPC in Victoria is a registered nurse employed by a service or organisation to work toward meeting the academic and clinical requirements for national endorsement as an NP. During the period of candidacy, which is of variable duration, NPCs consolidate their competence to work at the advanced practice level of an NP. The candidacy period is a process of learning the new role while engaging with mentors (medical and nursing) and accessing other learning opportunities both within and outside one's organisation to meet the educational requirements. Integral to the NP role is the development of a model of care that is responsive to identified service delivery gaps that can be addressed by the skills, knowledge, and expertise of an NP. These are unique to each individual service. The practice of an Australian NP is guided by national standards (Nursing and Midwifery Board of Australia 2014). It is defined by four overarching standards: clinical, education, research, and leadership. Following the initial endorsement of four Victorian palliative care NPs in 2005, there was a lull in recruitment. The Victoria Department of Health (DH) recognised the potential benefits of NPs for health services, and in 2008 it provided funding for Victorian public health services to scope palliative care NP models of care that could enhance service delivery and patient outcomes. The scoping strategy was effective and led to the appointment of 16 palliative care nurses to NPC positions over the ensuing 3 years. The NPCs work across a broad range of care settings, including inpatient, community, and outpatient in metropolitan, regional, and rural areas of Victoria. At the same time, the DH also funded the Centre for Palliative Care to establish the Victorian Palliative Care Nurse Practitioner Collaborative (VPCNPC) to support the NPs and NPCs. The Centre is a state-wide service that is part of St Vincent's Hospital Melbourne and a collaborative Centre of the University of Melbourne. Its primary function is to provide training and conduct research in palliative care. The purpose of the VPCNPC was to provide support and mentorship and develop resources targeted at palliative care NPs, NPCs, and health service managers. Membership of the VPCNPC is open to all NPs, NPCs, health service managers, and nurses interested in the NP role. The aim of this paper is to describe the development of the VPCNPC, its actions, and the outcomes of these actions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of the microtubule inhibitors colchicine (1 x 10(-3) M) and tubulozole-C(1 x 10(-6) M) on the ultrastructure of adult Fasciola hepatica has been determined in vitro by transmission electron microscopy (TEM), using both intact flukes and tissue-slice material. With colchicine treatment, the apical membrane of the tegument became increasingly convoluted and blebbed, while accumulations of T1 secretory bodies occurred in the basal region of the syncytium, leading to progressively fewer secretory bodies in the syncytium. In the tegumental cells there were distinct accumulations of T1 secretory bodies around the Golgi complexes, which remained active for up to 12 h incubation. Tubulozole-treated flukes showed more severe effects, with initial accumulations of secretory bodies, both at the tegumental apex and base. This was followed in the later time-periods by the sloughing of the tegumental syncytium. In the underlying tegumental cells, the granular endoplasmic reticulum (GER) cisternae were swollen and disrupted, becoming concentrated around the nucleus. The Golgi complexes were dispersed to the periphery of the cells and gradually disappeared from the cytoplasm. After treatment with both drugs, the cell population in the vitelline follicles was altered, with an abnormally large proportion of stem cells and relatively few intermediate type 1 cells. The nurse cell cytoplasm became fragmented and was no longer in contact with the vitelline cells, while the shell globule clusters within the intermediate type 2 and mature cells were loosely packed. In the mature vitelline cells, 'yolk' globules and glycogen deposits became fewer than normal and lipid droplets were observed. The results are discussed in relation to the different modes of action of the two drugs and potential significance of this to anthelmintic (benzimidazole) therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the permanent prostate brachytherapy (PPB) learning curve using postimplant multisector dosimetric analysis and to assess the correlation between sector -specific dosimetry and patient-reported outcome measures (PROMs).

METHODS AND METHODS: First 200 patients treated with (125)I PPB monotherapy (145 Gy) at a single institution were assessed. Postimplant dosimetry (PID) using CT was evaluated for whole prostate (global) and 12 sectors, assessing minimum dose to 90% of prostate (D90) and dose to 0.1 cm(3) of rectum (D0.1cc). Global and sector PID results were evaluated to investigate changes in D90 with case number. Urinary and bowel PROMs were assessed using the International Prostate Symptom Score and the Expanded Prostate Cancer Index Composite questionnaire. The correlation between global and individual sector PID and urinary/bowel PROMs was also evaluated.

RESULTS: Linear regression confirmed a significant improvement in global D90 with case number (r(2) = 0.20; p = 0.001) at a rate of 0.11 Gy/case. Postimplant D90 of base sectors increased at a rate of 0.11-0.15 Gy/case (p = 0.0001) and matched global improvement. The regression lines of midgland and apex sectors were significantly different from global D90 (p = 0.01). Posterior midgland sectors showed a significant reduction in D90 with case number at a rate of 0.13-0.19 Gy/case (p = 0.01). Dose to posterior midgland sectors correlated with rectal D0.1cc dose but not bowel PROMs. Dose to posterior midgland sectors correlated with urinary International Prostate Symptom Score change, which was not apparent when global D90 alone was considered.

CONCLUSIONS: Sector analysis provided increased spatial information regarding the PPB learning curve. Furthermore, sector analysis correlated with urinary PROMs and rectal dose.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulsed beams of energetic x-rays and neutrons from intense laser interactions with solid foils are promising for applications where bright, small emission area sources, capable of multi-modal delivery are ideal. Possible end users of laser-driven multi-modal sources are those requiring advanced non-destructive inspection techniques in industry sectors of high value commerce such as aerospace, nuclear and advanced manufacturing. We report on experimental work that demonstrates multi-modal operation of high power laser-solid interactions for neutron and x-ray beam generation. Measurements and Monte Carlo radiation transport simulations show that neutron yield is increased by a factor ∼2 when a 1 mm copper foil is placed behind a 2 mm lithium foil, compared to using a 2 cm block of lithium only. We explore x-ray generation with a 10 picosecond drive pulse in order to tailor the spectral content for radiography with medium density alloy metals. The impact of using >1 ps pulse duration on laser-accelerated electron beam generation and transport is discussed alongside the optimisation of subsequent bremsstrahlung emission in thin, high atomic number target foils. X-ray spectra are deconvolved from spectrometer measurements and simulation data generated using the GEANT4 Monte Carlo code. We also demonstrate the unique capability of laser-driven x-rays in being able to deliver single pulse high spatial resolution projection imaging of thick metallic objects. Active detector radiographic imaging of industrially relevant sample objects with a 10 ps drive pulse is presented for the first time, demonstrating that features of 200 μm size are resolved when projected at high magnification.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To determine the prevalence of untreated carious lesions in permanent teeth in patients (under the age of 18) referred for an orthodontic assessment in specialist practice. In addition, the figures shall be compared with national data for Northern Ireland (as outlined in the recent Child Dental Health Survey 2013)
The Gold standard would be that 100% of patients would be caries free upon presentation.

Methods: The clinical records and radiographs (OPT of quality grading 1 or 2) of 337 patients were reviewed. This encompassed patients who had an orthodontic assessment carried out in specialist practice over a 6 month period (following referral from their general dental practitioner)

Results: A total of 337 patient records were examined. Of these, 149 were male (44.2%) and 188 were female (55.8%), with an age range of 7-17 years at the time of new patient assessment. It was found that 36 patients (10.7%) had evidence (clinical and/or radiographic) of active and untreated dental caries. Of those affected, 14 were male and 22 were female.
Breaking the data down in terms of age, we can also get some indication as to how this cohort compares with national data for Northern Ireland :⃰

7-10 years (Mean = 9.3) = 14.3% caries (versus NI average of 6% for 8 year olds)
11-13 years (Mean = 12.1) = 10.1% caries, (versus NI average of 16% for 12 year olds)
14-17 years (Mean = 15.2) = 9.1% caries (versus NI average of 15% for 15 year olds)

⃰using the diagnostic threshold “Decay into dentine (visual dentine caries excluded)”


Conclusion: In this sample group, a total of 10.7% of patients (9.4% of males, 11.7% of females) presented with evidence of undiagnosed caries upon being assessed as a new patient in specialist orthodontic practice. Hence, the gold standard was not met.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente relatório de conclusão do curso de Mestrado Integrado em Medicina Veterinária da Universidade de Évora, refere-se ao período de estágio curricular obrigatório que decorreu na Clínica Equifort, em Fortaleza, Brasil, na área Patologia e Clínica de Equinos. Numa primeira fase é feita uma descrição das atividades desenvolvidas onde se apresenta a casuística acompanhada durante o estágio, que inclui atividades em diversas áreas como medicina desportiva, clínica médica, clínica reprodutiva, clínica cirúrgica e clínica hospitalar. Numa segunda fase desenvolve-se uma monografia onde se caracterizam as lesões radiográficas de membros anteriores de cavalos de desporto, e por fim são apresentados cinco casos clínicos; ABSTRACT: EQUINE PATHOLOGY AND CLINICAL The present report refers to curricular internship, integrated on the master degree in veterinary medicine at the University of Évora, that took place at the Clinic Equifort in Fortaleza, Brazil, in the área of Equine Pathology and Clinical. Initially a description of the activities accompanied during the internship is given which includes activities in areas such as sports medicine, internal medicine, reprodution and surgery. In a second part a monograph is developd with the characterization of radiographic injuries in forelimbs of sport’s horses, and finally five clinical cases are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contrastedetalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de mestrado. Biologia (Biologia Evolutiva e do Desenvolvimento). Universidade de Lisboa, Faculdade de Ciências, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de doutoramento, Medicina Dentária (Periodontologia), Universidade de Lisboa, Faculdade de Medicina Dentária, 2016

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de doutoramento, Biologia (Biologia do Desenvolvimento), Universidade de Lisboa, Faculdade de Ciências, 2015