885 resultados para physiological sensors
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This study evaluated stress indicators of juvenile piau (Leporinus friderici) during and after a 4-hour transportation in order to establish an appropriate transportation protocol for this type of fish. Fish were transported in plastic bags (133.1 g/L) and sampled before loading, during 1, 2, 3 and 4 h and after transportation (2, 6, 12 and 24 h). Blood samples were analyzed for cortisol and glucose levels, hematocrit, hemoglobin level, number and mean corpuscular volume of erythrocytes. Water pH, dissolved oxygen, temperature and ammonia were monitored before, during and after transportation. No mortality was observed through the experiment. Ammonia levels increased throughout transportation, but the low pH values kept NH3 in safe levels for fish. Cortisol levels increased within 4 h of transportation, and returned to control condition 2 h after arrival. Plasma glucose increased within one hour of transportation, reaching peak value within 4 h and returning to initial condition 2 h after arrival. Erythrocyte number and hemoglobin levels showed the lowest levels 2 h after arrival, and mean corpuscular volume increased during transportation, decreasing at 12 and 24 h after arrival. Transporting piau is stressful, but fish recover the initial condition in short time, showing tolerance to the changes in the water quality parameters.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Maize seeds developed at different portions of the ear of two hybrids (one, a large seeded, and the other a small seeded hybrid) were compared as to physical positions, morphological, and physiological characteristics viewing to gain information to be used during seed conditioning. The number of positions in the ear were 10, starting at the proximal and ending at the distal end. For the sake of simplification, the data were combined to refer to seeds of the proximal, the central and the distal sectors of an ear. Measurements made of the seeds as to shape (length, width, and thickness) and as to size (1,000 seeds weight) indicated that the round seeds growing at the distal sector are significantly smaller (mainly when thickness is considered) and lighter than those growing at the proximal sector. on the other hand, determinations of the physiological quality indicated that the round-proximal and the central seeds are equivalent and both significantly superior to the round-distal ones, Considering these significant differences as to size, shape, and physiological quality, a proposition of suppressing part of the round-distal from the totallity of the round seeds during the operations of seed conditioning is made.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The electrical conductivity test is still an excellent tool to evaluate the effect of seeds of various forest and agricultural species and recent studies have been conducted aiming at verifying its application in forest seeds. The objective of this study was to establish a specific methodology to test the electrical conductivity of forest seeds of Zeyheria tuberculosis. Four lots of seeds were used, which were submitted to the germination test, evaluating the percentage of germination, germination speed index and dry mass of seedlings. For the electrical conductivity test, five replicates of 20 seeds installed in three volumes of deionized water (75, 100 and 125 mL) were used and eight periods for seed imbibitions (2, 4, 6, 12, 18, 24, 48 and 72 hour) at 25 degrees C were allowed. The statistical design used was completely random; the comparison of means was performed by Tukey test at 5 % probability. Lot II showed higher germination percentage and speed. The electrical conductivity test allows discrimination of the same batch by the germination test under laboratory conditions. It was possible to separate the seed lot presenting better physiological quality (lot II) from among the other lots. It was recommended the use of 75 or 125 mL of deionized water at a temperature of 25 degrees C to perform the electrical conductivity test.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O uso de fontes não convencionais para fornecimento de K às plantas tem sido amplamente estudado, mas os efeitos de materiais alternativos na qualidade fisiológica das sementes não são conhecidos. Este estudo teve como objetivo avaliar a qualidade fisiológica de sementes de soja e trigo em função da aplicação fontes de potássio em uma sucessão de culturas. O delineamento experimental foi o de blocos ao acaso com quatro repetições. Os tratamentos constaram de três fontes de K (KCl, rocha alcalina e fonolito moído, com 58%, 11% e 8.42% de K2O, respectivamente) aplicados em quatro doses (0, 25, 50 e 100 kg K2O ha-1). As doses de potássio foram aplicadas na soja e seu efeito residual foi avaliado na cultura do trigo, cultivado em sucessão. Logo após a colheita, as sementes de soja e trigo foram avaliadas pelos testes de teor de água, massa de sementes, germinação, primeira contagem, condutividade elétrica, comprimento de plântulas e massa da matéria seca de plântulas. Plantas de soja adubadas com fontes alternativas para fornecimento de K produzem sementes com maior massa e menor permeabilidade de membranas comparado às com KCl; maior qualidade fisiológica de sementes de soja e massa de sementes de trigo são obtidas com maiores doses de K2O independente da fonte.
Resumo:
Plant nutrition can positively influence quality of seeds by improving plant tolerance to adverse climate. In this context, silicon is currently considered a micronutrient and it is beneficial to plant growth, especially Poaceaes such as white oat and wheat, thereby improving physiological quality of seeds. This study had the objective of evaluating the effects of silicon leaf application on plant tillering, silicon levels and physiological quality of white oat and wheat seeds besides establishing correlations between them. Two experiments were carried out in winter with white oat and wheat. The experimental design was the completely randomized block with eight replications. Treatments consisted of foliar application of silicon (0.8% of soluble silicon, as stabilized orthosilicic acid) and a control (with no application). Silicon levels in leaves were determined at flowering whereas the number of plants and panicles/spikes per area was counted right before harvest. Seed quality was evaluated right after harvest through mass, germination and vigor tests. Data was submitted to variance analysis and means were compared by the Tukey test at a probability level of 5%. Person's linear correlation test was performed among silicon level in plants, tillering and seed quality data. Silicon leaf application increases root and total length of white oat seedlings as an effect of higher Si level in leaves. Silicon leaf application increases mass of wheat seeds without affecting germination or vigor.
Resumo:
The quality of the vertical distribution measurements of humidity in the atmosphere is very important in meteorology due to the crucial role that water vapor plays in the earth's energy budget. The radiosonde is the humidity measurement device that provides the best vertical resolution. Also, radiosondes are the operational devices that are used to measure the vertical profile of atmospheric water vapor. The World Meteorological Organization (WMO) has carried out several intercomparison experiments at different climatic zones in order to identify the differences between the available commercial sensors. This article presents the results of an experiment that was carried out in Brazil in 2001 in which major commercial radiosonde manufacturers [e.g., Graw Radiosondes GmbH & Co., KG (Germany); MODEM (France); InterMet Systems (United States); Sippican, Inc. (United States); and Vaisala (Finland)] were involved. One of the main goals of this experiment was to evaluate the performance of the different humidity sensors in a tropical region. This evaluation was performed for different atmospheric layers and distinct periods of the day. It also considers the computation of the integrated water vapor (IWV). The results showed that the humidity measurements achieved by the different sensors were quite similar in the low troposphere (the bias median value regarding the RS80 was around 1.8%) and were quite dispersed in the superior layers (the median rms regarding the RS80 was around 14.9%).
Resumo:
This paper reports on a sensor array able to distinguish tastes and used to classify red wines. The array comprises sensing units made from Langmuir-Blodgett (LB) films of conducting polymers and lipids and layer-by-layer (LBL) films from chitosan deposited onto gold interdigitated electrodes. Using impedance spectroscopy as the principle of detection, we show that distinct clusters can be identified in principal component analysis (PCA) plots for six types of red wine. Distinction can be made with regard to vintage, vineyard and brands of the red wine. Furthermore, if the data are treated with artificial neural networks (ANNs), this artificial tongue can identify wine samples stored under different conditions. This is illustrated by considering 900 wine samples, obtained with 30 measurements for each of the five bottles of the six wines, which could be recognised with 100% accuracy using the algorithms Standard Backpropagation and Backpropagation momentum in the ANNs. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The versatility of sensor arrays made from nanostructured Langmuir-Blodgett (LB) and layer-by-layer (LBL) films is demonstrated in two ways. First, different combinations of sensing units are employed to distinguish the basic tastes, viz. sweet, sour, bitter, and salty tastes, produced, respectively, by small concentrations (down to 0.01 g/mol) of sucrose, HCl, quinine, and NaCl solutions. The sensing units are comprised of LB and/or LBL films from semiconducting polymers, a ruthenium complex, and sulfonated lignin. Then, sensor arrays were used to identify wines from different sources, with the high distinguishing ability being demonstrated in principal component analysis (PCA) plots. Particularly important was the fact that the sensing ability does not depend on specific interactions between analytes and the film materials, but a judicious choice of materials is, nevertheless, required for the materials to respond differently to a given sample. It is also shown that the interaction with the analyte may affect the morphology of the nanostructured films, as indicated with scanning electron microscopy. For instance, in wine analysis these changes are not irreversible and the original film morphology is retrieved if the sensing unit is washed with copious amounts of water, thus allowing the sensor unit to be reused.
Resumo:
Chemical sensors made from nanostructured films of poly(o-ethoxyaniline) POEA and poly(sodium 4-styrene sulfonate) PSS are produced and used to detect and distinguish 4 chemicals in solution at 20 mM, including sucrose, NaCl, HCl, and caffeine. These substances are used in order to mimic the 4 basic tastes recognized by humans, namely sweet, salty, sour, and bitter, respectively. The sensors are produced by the deposition of POEA/PSS films at the top of interdigitated microelectrodes via the layer-by-layer technique, using POEA solutions containing different dopant acids. Besides the different characteristics of the POEA/PSS films investigated by UV-Vis and Raman spectroscopies, and by atomic force microscopy.. it is observed that their electrical response to the different chemicals in liquid media is very fast, in the order of seconds, systematical, reproducible, and extremely dependent on the type of acid used for film fabrication. The responses of the as-prepared sensors are reproducible and repetitive after many cycles of operation. Furthermore, the use of an "electronic tongue" composed by an array of these sensors and principal component analysis as pattern recognition tool allows one to reasonably distinguish test solutions according to their chemical composition. (c) 2007 Published by Elsevier B.V.