668 resultados para obturator prostheses


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The introduction of more efficient diagnostic methods, new techniques in surgery and transplantation, antibiotics and chemotherapeutics more potent and novel materials for prostheses, catheters and probes significantly increased the life expectancy and quality of life of critically ill patients, on the other hand, hospital-acquired infections emerged as important iatrogenic complications. Invasive infections are a growing problem in public health hospitals in Brazil and worldwide. Among the various etiological agents found in the hospital environment, the genus Candida has been the third most frequently isolated pathogen. In general, invasive fungal infections are associated with high morbidity and mortality, difficulties in diagnosis, antimicrobial resistance, length of hospital stay and increased hospital costs. This mini review of the literature describes about epidemiology of hospital infection of Candida species, as well as its virulence factors and drugs resistance

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Candida yeasts are common in the oral cavity and can cause candidosis in the presence of predisposing factors, especially diabetes. The manifestation of the disease is related to this set of local factors such as the presence of dental prostheses, salivary pH, salivary flow and tobacco and the ability to form biofilms. Biofilms are specific and organized communities of cells under the control of signaling molecules rather than random accumulations of cells resulting from cell division and frequently are drugs resistance. Aim: The objectives of this study were to determine the genetic patterns of these C. albicans isolates and to evaluate the in vitro activity amphotericin B and caspofungin against C. albicans biofilms. Methods: Microbial samples were collected from subgingival sites and seeded in CHROMagar for subsequent identification of C. albicans by PCR. Genotypes were defined based on the identification of the transposable introns in the 25S rDNA by PCR. Results: In this study, 6 strains were identified as C. albicans and of these, 3 strains were genotype A and 3 were genotype B. The results showed that both amphotericin B and caspofungin exhibited strong antifungal activities against C. albicans biofilm formation and inhibiting the biofilm formation ranging from 70.8 – 95.3% and 77.7 - 88.7%, respectively. The antifungals studied had low inhibitory effect on preformed biofims, ranging from 39.5 - 50.8% for amphotericin B and from 23.1 - 36.9% for caspofungin at the same concentration. The activity of the two drugs was most effective in inhibit biofilm formation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many patients seeking dental care wish to improve facial and smile aesthetics to be accepted in modern day society. In denture wearers, the physiological resorption causes atrophy mainly in the maxilla, being necessary to carry out reconstruction techniques and sometimes orthognathic surgery to improve occlusal stability and facial harmony. The aim of this study is to discuss the features related to the rehabilitation of edentulous patients with indication for reconstruction of the maxilla using bone grafts and orthognathic surgery by means of a clinical case. In the present case, after the prosthetic rehabilitation, the patient was full satisfied with obtained results and dismissed the initially proposed surgical protocol. Therefore, professionals should provide therapeutic options but the patient’s opinion should prevail provided its clinical feasibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Osseointegrated implants have specific nature distinguish them from natural teeth making them more susceptible to the efforts generated by mastication. The absence of periodontal ligament, which absorbs the masticatory forces and allows the movement of the teeth interfere with the reception of occlusal loads and therefore the predictability of implants. In the boneimplant interface did not occur the phenomena of dissipation of impact, even the movement induced. Thus, during planning and installation of implant prosthesis, the type and characteristics of occlusal pattern adopted should be established with criteria to be no grounds for future failures. In this regard we highlight the occlusal overload generated by several reasons like the presence of premature contacts, interference during motion excursive, deleterious habits and inappropriate extensions on cantilevers. Thus, the objective is to provide a review of the literature regarding the importance of occlusion in oral rehabilitation with implants. Factors to be considered in establishing a favorable occlusion, consistent with prostheses on implants will be described

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: to evaluate implant survival immediately placed after tooth extraction considering different sites, prosthodontic modalities, and the need for biomaterials. Material and methods: dental records of 500 patients treated with dental implants between 2004 and 2011 were screened. Results: only 200 records (20%) corresponded to immediate implants. Reasons for tooth extraction included extensive caries, bone loss, and root fractures. From the 197 immediate dental implants, 86 were placed in the maxilla with a survival rate of 93.9% and 111 in the mandible (survival rate of 99.1%). The overall survival rate was 97.46%. Prosthodontic modalities identified were: Brånemark classic complete denture screwed prostheses (36%), overdentures (5.6%), fixed partial denture (31%), and single-tooth prostheses (27.4%). Also, it was observed that in 33% of cases there was a need for the use of grafts and/or biomaterials. Conclusion: it can be concluded that, when correctly indicated, immediate implants are an excellent choice. The anterior mandibular region, screwed and overdenture-type prostheses presented higher success rates when associated to immediate implant placement. The need for bone graft/biomaterial does not affect the clinical results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the deformation suffered by cantilevered implant-supported fixed prostheses frameworks cast in silver-palladium alloy and coated with two occlusal veneering materials: acrylic resin or porcelain. Material and Methods: Two strain gauges were bonded to the inferior surface of the silver-palladium framework and two other were bonded to the occlusal surface of the prosthesis framework covered with ceramic and acrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2 N compression force was applied to the cantilever at 10, 15 and 20 mm from the most distal implant. The measurements of deformation by compression and tension were obtained. The statistical 2-way ANOVA test was used for individual analysis of the experiment variables and the Tukey test was used for the interrelation between all the variables (material and distance of force application). Results: The results showed that both variables had influence on the studied factors (deformation by compression and tension). Conclusion: The ceramic coating provided greater rigidity to the assembly and therefore less distortion compared with the uncoated framework and with the resin-coated framework. The cantilever arm length also influenced the prosthesis rigidity, causing higher deformation the farther the load was applied from the last implant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because of their low elasticity modulus, titanium alloys have excellent biocompatibility, and are largely used in orthopedic prostheses. Among the properties that are beneficial for use in orthopedic implants is the elasticity modulus, which is closely connected to the crystal structure of the material. Interstitial elements, such as oxygen, change the mechanical properties of the material. Anelastic spectroscopy measurements are a powerful tool for the study of the interaction of these elements with the metallic matrix and substitutional solutes, providing information on the diffusion and concentration of interstitial elements. In this study, the effect of oxygen on the anelastic properties of alloys in the Ti-15Mo-Zr system was analyzed using anelastic spectroscopy measurements. The diffusion coefficients, pre-exponential factors, and activation energies of these alloys were calculated for oxygen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The oral cavity is a complex environment where corrosive substances from dietary, human saliva, and oral biofilms may accumulate in retentive areas of dental implant systems and prostheses promoting corrosion at their surfaces. Additionally, during mastication, micromovements may occur between prosthetic joints causing a relative motion between contacting surfaces, leading to wear. Both processes (wear and corrosion) result in a biotribocorrosion system once that occurs in contact with biological tissues and fluids. This review paper is focused on the aspects related to the corrosion and wear behavior of titanium-based structures in the oral environment. Furthermore, the clinical relevance of the oral environment is focused on the harmful effect that acidic substances and biofilms, formed in human saliva, may have on titanium surfaces. In fact, a progressive degradation of titanium by wear and corrosion (tribocorrosion) mechanisms can take place affecting the performance of titanium-based implant and prostheses. Also, the formation of wear debris and metallic ions due to the tribocorrosion phenomena can become toxic for human tissues. This review gathers knowledge from areas like materials sciences, microbiology, and dentistry contributing to a better understanding of bio-tribocorrosion processes in the oral environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Titanium alloys have excellent biocompatibility, and combined with their low elastic modulus, become more efficient when applied in orthopedic prostheses. Samples of Ti-15Mo-Zr and Ti-15Zr-Mo system alloys were prepared using an arc-melting furnace with argon atmosphere. The chemical quantitative analysis was performed using an optical emission spectrometer with inductively coupled plasma and thermal conductivity difference. The X-ray diffractograms, allied with optical microscopy, revealed the structure and microstructure of the samples. The mechanical analysis was evaluated by Vickers microhardness measurements. The structure and microstructure of alloys were sensitive to molybdenum and zirconium concentration, presenting α′, α″ and β phases. Molybdenum proved to have greater β-stabilizer action than zirconium. Microhardness was changed with addition of molybdenum and zirconium, having Ti-15Zr-10Mo (436 ± 2 HV) and Ti-15Mo-10Zr (378 ± 4 HV) the highest values in each system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)