888 resultados para matlab push-off tests steel fiber reinforced concrete
Resumo:
Purpose: To evaluate the pullout strength of a glass fiber-reinforced composite post (glass FRC) cemented with three different adhesive systems and one resin cement. The null hypothesis was that pullout strengths yielded by the adhesive systems are similar. Materials and Methods: Thirty bovine teeth were selected. The size of the specimens was standardized at 16 mm by sectioning off the coronal portion and part of the root. The specimens were divided into three groups, according to the adhesive system, which were applied following the manufacturers' instructions: G1, ScotchBond Multi-Purpose Plus; G2, Single Bond; G3, Tyrian SPE/One-Step Plus. The glass FRCs (Reforpost) were etched with 37% H3PO4 for 1 min and silanized (Porcelain Primer). Thereafter, they were cemented with the dual resin cement En-Force. The specimens were stored for 24 h, attached to an adapted device, and submitted to the pullout test in a universal testing machine (1 mm/min). The data were submitted to the one-way ANOVA and Tukey's test (α = 0.05). Results: G1 (30.2 ± 5.8 Kgf) displayed the highest pullout strength (p < 0.001) when compared to G2 (18.6 ± 5.8 Kgf) and G3 (14.3 ± 5.8 Kgf), which were statistically similar. Analysis of the specimens revealed that all failures occurred between the adhesive system and the root dentin (pullout of the post cement), regardless of group. Conclusion: The multiple-bottle, total-etch adhesive system provided higher pullout strength of the glass FRC when compared to the single-bottle, total-etch, and single-step self-etching adhesive systems. The null hypothesis was rejected (p < 0.001).
Resumo:
This study aimed to evaluate the influence of cement thickness on the bond strength of a fiber-reinforced composite (FRC) post system to the root dentin. Eighteen single-rooted human teeth were decoronated (length: 16 mm), the canals were prepared, and the specimens were randomly allocated to 2 groups (n = 9): group 1 (low cement thickness), in which size 3 FRC posts were cemented using adhesive plus resin cement; and group 2 (high cement thickness), in which size 1 FRC posts were cemented as in group 1. Specimens were sectioned, producing 5 samples (thickness: 1.5 mm). For cement thickness evaluation, photographs of the samples were taken using an optical microscope, and the images were analyzed. Each sample was tested in push-out, and data were statistically analyzed. Bond strengths of groups 1 and 2 did not show significant differences (P = .558), but the cement thicknesses for these groups were significantly different (P < .0001). The increase in cement thickness did not significantly affect the bond strength (r2 = 0.1389, P = .936). Increased cement thickness surrounding the FRC post did not impair the bond strength.
Resumo:
Carbon fiber reinforced polymer composites have been used in wide variety of applications including, aerospace, marine, sporting equipment as well as in the defense sector due to their outstanding properties at low density. In many of their applications, moisture absorption takes place which may result in a reduction in mechanical properties even at lower temperature service. In this work, the viscoelastic properties, such as storage modulus (E′) and loss modulus (E″), were obtained through vibration damping tests for three carbon fiber/epoxy composite families up to the saturation point (6 weeks). Three carbon fiber/epoxy composites having [0/0] s, [0/90] s, and [±45] s orientations were studied. During vibration tests the storage modulus (E′) and loss modulus (E″) were monitored as a function of moisture uptake, and it was observed that the natural frequencies and E′ values decreased with the increase during hygrothermal conditioning due to the matrix plasticization. © 2007 Wiley Periodicals, Inc.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Este trabalho visou a demonstrar o dimensionamento e verificação de cálculo da NBR 6118 (ABNT, 2007) com as suas características geométricas, cobrimento da armadura, armaduras, flambagem e a resistência de pilares à compressão centrada dos pilares em concreto armado, apresentando na revisão bibliográfica as principais técnicas de reforço estrutural de pilares de concreto armado para edificações antigas, identificando as principais metodologias e técnicas utilizadas no Brasil e apresentando os pontos positivos e negativos de cada técnica:encamisamento de concreto, perfis metálicos, chapa de aço colado, manta/tecido de carbono, aramida e vidro e polímeros reforçados com fibras de carbono (PRFC). Os pilares com aumento da seção transversal retangular, com adição de armação e concreto, sendo mais usual e prática a técnica apresenta dificuldades em obras antigas, geralmente devido à necessidade arquitetônica de permanecer o mais fiel a sua forma original. Justificando-se a necessidade de conhecimento das diversas técnicas de reforço estrutural descritas neste trabalho com aumento de capacidade de resistência, sem que haja aumento substancial, na seção transversal dos pilares e objetivando a análise do reforço proposto através dos cálculos do projeto, programa – PDOP 2.0 e parâmetros de cálculo da NBR 6118 (ABNT, 2007). Os resultados obtidos através da análise comparativa do reforço executado no estudo de caso “revitalização do casarão” - com relação à análise dos pilares retangulares submetidos à flexão composta oblíqua, esforços cortantes e torsores quanto à NBR 6118 (ABNT, 2007) utilizando o programa para dimensionamento otimizado de pilares – PDOP 2.0 - indicaram que a técnica de reforço estudada foi eficiente, pois todas as peças reforçadas tiveram uma capacidade portante maior que a do pilar original sem o reforço.
Resumo:
The bond between steel and concrete is essential for the existence of reinforced concrete structures, as both materials act together to absorb structural strain. The bond phenomenon is considered to be complex regarding many factors that affect it. Several types of bond tests have been proposed over years. One is the modified proposed of pull-out test, which was elaborated by Lorrain and Barbosa [1] called APULOT test (Appropriete pull-out-test). Based on experimental results obtained by Vale Silva[2] either by conventional pull-out tests, or by modified pull-out test, APULOT, seeks to know the numeric behavior of bond steel-concrete through a numerical simulation using a calculation code ATENA which is based on the Finite Element Method (FEM). The numerical simulation provided better evaluate the stress distribution and cracking that occurs during the test, thereby becoming a valuable tool to support the experimental project that aims to validation, validation partially or not recommend the modified bond test steel-concrete - APULOT test - as quality control test of structural concrete. The numerical results showed good representation compared to experimental results.
Fatigue crack growth rate in mode I of a carbon fiber 5HS weave composite laminate processed via RTM
Resumo:
Delamination or crack propagation between plies is a critical issue for structural composites. In viewing this issue and the large application of woven fabrics in structural applications, especially the ones that requires high drapeability to be preformed in a RTM mold cavity such as the asymmetric ones, e.g HS series, this research aimed in dynamically testing the carbon fiber 5HS/RTM6 epoxy composites under opening mode using DCB set up in order to investigate the crack growth rate behavior in an irregular surface produced by the fabric waviness. The evaluation of the energy involved in each crack increment was based on the Irwin-Kies equation using compliance beam theory. The tests were conducted at constant stress ratio of R=0.1 with displacement control, frequency of 10 Hz, in accordance to ASTM E647-00 for measurement of crack growth rate. The results showed large scatter when compared to unidirectional carbon fiber composites due to damage accumulation at the fill tows.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work talks about the importance of the steel adhesion to concrete, reinforced concrete structures, their testing and forms of measurement used and how the results are used in the structural design, which uses as a reference the NBR 6118 and NBR 7480. It also deals with the importance of a reliable assessment, discussing failures that the test used, NBR 7477, features in specific circumstances, as discussed under the EC-094. It also presents an initial proposal for simplified pullout test, which aims to analyze the grip on steel bars with diameter less than 10 mm, which results when used standardized testing by ABNT NBT 7477, has shown excessive variability, the main criticism of the trial today used without distinction to be established thick or thin bars. The proposal also presented methodology is in the consolidation phase, given the time and the volume of necessary tests. For this reason it is not possible to make a comparison between the values obtained and the results of the test used on the basis of the standard in force, this can only be done once the front with a continuation of this work
Resumo:
This work talks about the importance of the steel adhesion to concrete, reinforced concrete structures, their testing and forms of measurement used and how the results are used in the structural design, which uses as a reference the NBR 6118 and NBR 7480. It also deals with the importance of a reliable assessment, discussing failures that the test used, NBR 7477, features in specific circumstances, as discussed under the EC-094. It also presents an initial proposal for simplified pullout test, which aims to analyze the grip on steel bars with diameter less than 10 mm, which results when used standardized testing by ABNT NBT 7477, has shown excessive variability, the main criticism of the trial today used without distinction to be established thick or thin bars. The proposal also presented methodology is in the consolidation phase, given the time and the volume of necessary tests. For this reason it is not possible to make a comparison between the values obtained and the results of the test used on the basis of the standard in force, this can only be done once the front with a continuation of this work
Resumo:
Objective: This study evaluated the performance of different adhesive systems in fiber post placement aiming to clarify the influence of different hydrophobic experimental blend adhesives, and of one commercially available adhesive on the frictional retention during a luting procedure. Material and Methods: One luting agent (70 Wt% BisGMA, 28.5% TEGDMA; 1.5% p-tolyldiethanolamine) to cement fiber posts into root canals was applied with 4 different adhesive combinations: Group 1: The etched roots were rinsed with water for 30 s to remove the phosphoric acid, then rinsed with 99.6% ethanol for 30 s, and blot-dried. A trial adhesive (base to catalyst on a 1: 1 ratio) was used with an experimental luting agent (35% Bis-GMA, 14.37% TEGDMA, 0.5% EDMAB, 0.13% CQ); Group 2: A trial adhesive (base to catalyst on a 1: 2 ratio) was luted as in Group 1; Group 3: One-Step Plus (OSP, Bisco Inc.) following the ethanol bonding technique in combination with the luting agent as in Group 1; Group 4: OSP strictly following the manufacturer's instructions using the luting agent as in Group 1. The groups were challenged with push-out tests. Posted root slices were loaded until post segment extrusion in the apical-coronal direction. Failure modes were analyzed under scanning electron microscopy. Results: Push-out strength was not significantly influenced by the luting agent (p>0.05). No statistically significant differences among the tested groups were found as Group 1 (Exp 1 - ethanol-wet bonding technique)=Group 2 (Exp 2 - ethanol-wet bonding technique)= Group 3 (OSP - ethanol-wet bonding technique)= Group 4 (control, OSP - water-wet bonding technique) (p>0.05). The dominating failure modes in all the groups were cohesive/adhesive failures, which were predominantly observed on the post/luting agent interface. Conclusions: The results of this study support the hypothesis that the proposal to replace water with ethanol to bond fiber posts to the root canal using highly hydrophobic resin is plausible, but this seems to be more the proof of a concept than a clinically applicable procedure.
Resumo:
There are currently many types of protective materials for reinforced concrete structures and the influence of these materials in the chloride diffusion coefficient and water penetration still needs more research. The aim of this work is to analyze the contributions regarding the typical three surface concrete protection systems (coatings, linings and pore blockers) and discusses the results of three pore blockers (sodium silicate) tested in this work. To this end, certain tests were used: one involving permeability mechanism (low pressure-immersion absorption), one involving capillary water absorption, and the last, a migration test used to estimate the effective chloride diffusion coefficient in saturated condition. Results indicated reduction in chloride diffusion coefficients and capillary water absorption, therefore, restrictions to water penetration from external environmental. As a consequence, a reduction of the corrosion kinetics and a control of the chloride ingress are expected.
Resumo:
L’utilizzo degli FRP (Fiber Reinforced Polymer) nel campo dell’ingegneria civile riguarda essenzialmente il settore del restauro delle strutture degradate o danneggiate e quello dell’adeguamento statico delle strutture edificate in zona sismica; in questi settori è evidente la difficoltà operativa alla quale si va in contro se si volessero utilizzare tecniche di intervento che sfruttano materiali tradizionali. I motivi per cui è opportuno intervenire con sistemi compositi fibrosi sono: • l’estrema leggerezza del rinforzo, da cui ne deriva un incremento pressoché nullo delle masse sismiche ed allo stesso tempo un considerevole aumento della duttilità strutturale; • messa in opera senza l’ausilio di particolari attrezzature da un numero limitato di operatori, da cui un minore costo della mano d’opera; • posizionamento in tempi brevi e spesso senza interrompere l’esercizio della struttura. Il parametro principale che definisce le caratteristiche di un rinforzo fibroso non è la resistenza a trazione, che risulta essere ben al di sopra dei tassi di lavoro cui sono soggette le fibre, bensì il modulo elastico, di fatti, più tale valore è elevato maggiore sarà il contributo irrigidente che il rinforzo potrà fornire all’elemento strutturale sul quale è applicato. Generalmente per il rinforzo di strutture in c.a. si preferiscono fibre sia con resistenza a trazione medio-alta (>2000 MPa) che con modulo elastico medio-alto (E=170-250 GPa), mentre per il recupero degli edifici in muratura o con struttura in legno si scelgono fibre con modulo di elasticità più basso (E≤80 GPa) tipo quelle aramidiche che meglio si accordano con la rigidezza propria del supporto rinforzato. In questo contesto, ormai ampliamente ben disposto nei confronti dei compositi, si affacciano ora nuove generazioni di rinforzi. A gli ormai “classici” FRP, realizzati con fibre di carbonio o fibre di vetro accoppiate a matrici organiche (resine epossidiche), si affiancano gli FRCM (Fiber Reinforced Cementitious Matrix), i TRM (Textile Reinforced Mortars) e gli SRG (Steel Reinforced Grout) che sfruttano sia le eccezionali proprietà di fibre di nuova concezione come quelle in PBO (Poliparafenilenbenzobisoxazolo), sia un materiale come l’acciaio, che, per quanto comune nel campo dell’edilizia, viene caratterizzato da lavorazioni innovative che ne migliorano le prestazioni meccaniche. Tutte queste nuove tipologie di compositi, nonostante siano state annoverate con nomenclature così differenti, sono però accomunate dell’elemento che ne permette il funzionamento e l’adesione al supporto: la matrice cementizia