970 resultados para machine fault diagnosis
Resumo:
Objective: To assess quantitative real-time polymerase chain reaction (q-PCR) for the sputum smear diagnosis of pulmonary tuberculosis (PTB) in patients living with HIV/AIDS with a clinical suspicion of PTB.Method: This is a prospective study to assess the accuracy of a diagnostic test, conducted on 140 sputum specimens from 140 patients living with HIV/AIDS with a clinical suspicion of PTB, attended at two referral hospitals for people living with HIV/AIDS in the city of Recife, Pernambuco, Brazil. A Löwenstein-Jensen medium culture and 7H9 broth were used as gold standard.Results: Of the 140 sputum samples, 47 (33.6%) were positive with the gold standard. q-PCR was positive in 42 (30%) of the 140 patients. Only one (0.71%) did not correspond to the culture. The sensitivity, specificity and accuracy of the q-PCR were 87.2%, 98.9% and 95% respectively. In 39 (93%) of the 42 q-PCR positive cases, the CT (threshold cycle) was equal to or less than 37.Conclusion: q-PCR performed on sputum smears from patients living with HIV/AIDS demonstrated satisfactory sensitivity, specificity and accuracy, and may therefore be recommended as a method for diagnosing PTB.
Resumo:
Visceral Leishmaniasis has been showing remarkable epidemiological changes in recent decades, with marked expansion and an emergence of cases in urban areas of the North, Southeast and Midwest regions of Brazil. The Kala-azar cases reported here, despite being very characteristic, presented a great difficulty of diagnosis, because the disease is not endemic in Volta Redonda. The child underwent two hospitalizations in different hospitals, but got the correct diagnosis only after 11 months of symptom onset. In this report we discuss the main differential diagnoses and call attention to the suspected symptoms of visceral leishmaniasis in patients with prolonged fever, hepatosplenomegaly and pancytopenia, even in areas not traditionally endemic for the disease.
Resumo:
New methodologies were developed for the identification of Nocardia but the initial diagnosis still requires a fast and accurate method, mainly due to the similarity to Mycobacterium, both clinical and bacteriologically. Growth on Löwenstein-Jensen (LJ) medium, presence of acid-fast bacilli through Ziehl-Neelsen staining, and colony morphology can be confusing aspects between Nocardia and Mycobacterium. This study describes the occurrence of Nocardia spp. in a mycobacterial-reference laboratory, observing the main difficulties in differentiating Nocardia spp. from Mycobacterium spp., and correlating isolates with nocardiosis cases. Laboratory records for the period between 2008 and 2012 were analyzed, and the isolates identified as Nocardia sp. or as non-acid-fast filamentous bacilli were selected. Epidemiological and bacteriological data were analyzed as well. Thirty-three isolates identified as Nocardia sp. and 22 as non-acid-fast bacilli were selected for this study, and represented 0.12% of isolates during the study period. The presumptive identification was based on macroscopic and microscopic morphology, resistance to lysozyme and restriction profiles using the PRA-hsp65 method. Nocardia spp. can grow on media for mycobacteria isolation (LJ and BBL MGIT™) and microscopy and colony morphology are very similar to some mycobacteria species. Seventeen patients (54.8%) were reported and treated for tuberculosis, but presented signs and symptoms of nocardiosis. It was concluded that the occurrence of Nocardia sp. during the study period was 0.12%. Isolates with characteristics of filamentous bacilli, forming aerial hyphae, with colonies that may be pigmented, rough and without the BstEII digestion pattern in PRA-hsp65 method are suggestive of Nocardia spp. For a mycobacterial routine laboratory, a flow for the presumptive identification of Nocardia is essential, allowing the use of more accurate techniques for the correct identification, proper treatment and better quality of life for patients.
Resumo:
To contribute to the validation of the sensory and behavioral criteria for Regulation Disorders of Sensory Processing (RDSP) (DC:0-3R, 2005), this study examined a sample of toddlers in a clinical setting to analyze: (1) the severity of sensory modulation deficits and the behavioral symptoms of RDSP; (2) the associations between sensory and behavioral symptoms; and (3) the specific role of sensory modulation deficits in an RDSP diagnosis. Based on clinical observations, 78 toddlers were classified into two groups: toddlers with RDSP (N = 18) and those with‘‘other diagnoses in Axis I/II of the DC:0-3R’’ (OD3R; N = 60). The parents completed the Infant Toddler Sensory Profile and the Achenbach Checklist. The results revealed that the RDSP group had more severe sensory modulation deficits and specific behavioral symptoms; stronger, although not significant, associations between most sensory and behavioral symptoms; and a significant sensory modulation deficit effect. These findings support the validity of RDSP.
Resumo:
BACKGROUND: Wireless capsule endoscopy has been introduced as an innovative, non-invasive diagnostic technique for evaluation of the gastrointestinal tract, reaching places where conventional endoscopy is unable to. However, the output of this technique is an 8 hours video, whose analysis by the expert physician is very time consuming. Thus, a computer assisted diagnosis tool to help the physicians to evaluate CE exams faster and more accurately is an important technical challenge and an excellent economical opportunity. METHOD: The set of features proposed in this paper to code textural information is based on statistical modeling of second order textural measures extracted from co-occurrence matrices. To cope with both joint and marginal non-Gaussianity of second order textural measures, higher order moments are used. These statistical moments are taken from the two-dimensional color-scale feature space, where two different scales are considered. Second and higher order moments of textural measures are computed from the co-occurrence matrices computed from images synthesized by the inverse wavelet transform of the wavelet transform containing only the selected scales for the three color channels. The dimensionality of the data is reduced by using Principal Component Analysis. RESULTS: The proposed textural features are then used as the input of a classifier based on artificial neural networks. Classification performances of 93.1% specificity and 93.9% sensitivity are achieved on real data. These promising results open the path towards a deeper study regarding the applicability of this algorithm in computer aided diagnosis systems to assist physicians in their clinical practice.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
The aim of our study was to access office hysteroscopy results in postmenopausal patients with thickened endometrium. A retrospective descriptive study was carried out on 245 postmenopausal patients submitted to office hysteroscopy after sonographic diagnosis of thickened endometriumin 20 consecutive months.Women were evaluated for age, hormonal therapy, hysteroscopic findings, procedure duration, complications and associated pain, and histological diagnosis. Patients with and without uterine bleeding were considered separately. Symptomatic patients were older and had longer procedure duration. The most frequent hysteroscopic finding was endometrial polyp in both groups. Pain was subjectively assessed in a numeric scale from 0 to 10 and median value was 4. There were no complications reported. Global neoplasia rate was 2.9% for asymptomatic patients and 16.4% for symptomatic ones (p<0.05). Thickened endometrium with postmenopausal metrorrhagia gave patients a significantly higher risk for neoplasia and hyperplasia.
Resumo:
This document presents particular description of work done during student’s internship in PR Metal company realized as ERASMUS PROJECT at ISEP. All information including company’s description and its structure, overview of the problems and analyzed cases, all stages of projects from concept to conclusion can be found here. Description of work done during the internship is divided here into two pieces. First part concerns one activities of the company which is robotic chefs (kitchen robot) production line. Work, that was done for development of this line involved several tasks, among them: creating a single-worker montage station for screwing robots housing’s parts, improve security system for laser welding chamber, what particularly consists in designing automatically closing door system with special surface, that protects against destructive action of laser beam, test station for examination of durability of heating connectors, solving problem with rotors vibrations. Second part tells about main task, realized in second half of internship and stands a complete description of machine development and design. The machine is a part of car handle latch cable production line and its tasks are: cutting cable to required length and hot-forming plastic cover for further assembly needs.
Resumo:
The outbreaks of rabies in humans transmitted by Desmodus rotundus in 2004 and 2005, in the northeast of the Brazilian State of Para, eastern Amazon basin, made this a priority area for studies on this zoonosis. Given this, the present study provides data on this phenomenon in an urban context, in order to assess the possible circulation of the classic rabies virus (RABV) among bat species in Capanema, a town in the Amazon basin. Bats were collected, in 2011, with mist nets during the wet and dry seasons. Samples of brain tissue and blood were collected for virological and serological survey, respectively. None of the 153 brain tissue samples analyzed tested positive for RABV infection, but 50.34% (95% CI: 45.67-55.01%) of the serum samples analyzed were seropositive. Artibeus planirostris was the most common species, with a high percentage of seropositive individuals (52.46%, 95% CI: 52.31 52.60%). Statistically, equal proportions of seropositive results were obtained in the rainy and dry seasons (c2 = 0.057, d.f. = 1, p = 0.88). Significantly higher proportions of males (55.96%, 95% CI: 48.96-62.96%) and adults (52.37%, 95% CI: 47.35-57.39%) were seropositive. While none of the brain tissue samples tested positive for infection, the high proportion of seropositive specimens indicates that RABV may be widespread in this urban area.
Resumo:
Trichomonas vaginalis is the etiologic agent of trichomoniasis, the most common non-viral sexually transmitted disease (STD) in the world. The diagnosis is based on wet mount preparation and direct microscopy on fixed and stained clinical specimens. The aim of this study was to compare the performance of different fixing and staining techniques used in the detection of T. vaginalis in urine. The smears were fixed and submitted to different methods of permanent staining and then, the morphological aspects of the parasites were analyzed and compared. The Papanicolaou staining with ethanol as the fixative solution showed to be the best method of permanent staining. Our data suggest that staining techniques in association with wet mount examination of fresh specimens contribute to increase the sensitivity in the diagnosis of trichomoniasis.
Resumo:
Liver biopsy is the gold standard method for the grading and staging of chronic viral hepatitis, but optimal biopsy specimen size remains controversial. The aim of this study was to evaluate the quality of liver specimen (number of portal tracts) and to evaluate the impact of the number of portal tracts in the staging of chronic hepatitis. Material and Methods: 468 liver biopsies from consecutive patients with hepatitis C virus and hepatitis B virus infection from 2009 to 2010 were evaluated. Results: The length of fragment was less than 10 mm in 43 cases (9.3%), between 10 and 14 mm in 114 (24.3%), and ≥ 15 mm in 311 (64.4%); of these, in 39 (8.3%) cases were ≥ 20 mm. The mean representation of portal tracts was 17.6 ± 2.1 (5-40); in specimens ≥ 15 mm the mean portal tract was 13.5 ± 4.7 and in cases ≤ 15 mm was 11.4 ± 5.0 (p = 0.002). Cases with less than 11 portal tracts were associated with F3, and cases with 11 or more portal tracts with F2 (p = 0.001). Conclusion: this study demonstrated the good quality of liver biopsy and a relationship between the macroscopic size of the fragment and the number of portal tracts.
Resumo:
The loop-mediated isothermal amplification method (LAMP) is a recently developed molecular technique that amplifies nucleic acid under isothermal conditions. For malaria diagnosis, 150 blood samples from consecutive febrile malaria patients, and healthy subjects were screened in Thailand. Each sample was diagnosed by LAMP, microscopy and nested polymerase chain reaction (nPCR), using nPCR as the gold standard. Malaria LAMP was performed using Plasmodiumgenus and Plasmodium falciparum specific assays in parallel. For the genus Plasmodium, microscopy showed a sensitivity and specificity of 100%, while LAMP presented 99% of sensitivity and 93% of specificity. For P. falciparum, microscopy had a sensitivity of 95%, and LAMP of 90%, regarding the specificity; and microscopy presented 93% and LAMP 97% of specificity. The results of the genus-specific LAMP technique were highly consistent with those of nPCR and the sensitivity of P. falciparum detection was only marginally lower.
Resumo:
Circulating anti-phospholipase A2 receptor antibodies (anti-PLA2R) have been described in 70% to 80% of the patients with idiopathic membranous nephropathy (iMN), but not in patients with secondary membranous nephropathy or other glomerular diseases. The goal of this study was to evaluate the sensitivity and specificity of the assay for anti-PLA2R in the diagnosis of iMN. Anti-PLA2R IgG, Elisa and immunofluorescence tests were used to detect circulating anti-PLA2R. These tests were applied in 53 patients who had a kidney biopsy. Of these, 38 had histological diagnosis of membranous nephropathy (MN) and the remaining had other glomerular diseases. The MN was classified as idiopathic in 33 patients after clinical exclusion of secondary causes. Anti-PLA2R were positive in 57.6% of the patients with iMN. All patients with secondary membranous nephropathy or other glomerular diseases did not show circulating anti-PLA2R. The sensitivity was 57.6% (CI 39.2-74.5) and specificity 100% (CI 47.8-100), AUC 0.788; p < 0.0001 for the detection of iMN. 71.4% of the iMN patients that tested negative for anti-PLA2R were in partial or complete remission. The detection of anti-PLA2R in the studied population had a specificity of 100% for the iMN diagnosis. Prior treatments seem to make the test negative and contribute to a lower sensitivity.