941 resultados para lower-limb swelling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Natural killer T (NKT) cells are efficiently targeted by HIV and severely reduced in numbers in the circulation of infected individuals. The functional capacity of the remaining NKT cells in HIV-infected individuals is poorly characterized. This study measured NKT cell cytokine production directly ex vivo and compared these responses with both the disease status and NKT subset distribution of individual patients. Methods: NKT cell frequencies, subsets, and ex-vivo effector functions were measured in the peripheral blood mononuclear cells of HIV-infected patients and healthy controls by flow cytometry. We measured cytokines from NKT cells after stimulation with either a-galactosyl ceramide-loaded CD1d dimers (DimerX-alpha GalCer) or phorbol myristate acetate and ionomycin. Results: The frequencies of NKT cells secreting interferon-gamma and tumor necrosis factor-alpha were significantly lower in HIV-infected patients than healthy controls after DimerX-alpha GalCer treatment, but responses were similar after treatment with phorbol myristate acetate and ionomycin. The magnitude of the interferon-gamma response to DimerX-alpha GalCer correlated inversely with the number of years of infection. Both interferon-gamma and tumor necrosis factor-alpha production in response to DimerX-alpha GalCer correlated inversely with CD161 expression. Conclusion: The ex-vivo Th1 responses of circulating NKT cells to CD1d-glycolipid complexes are impaired in HIV-infected patients. NKT cell functions may be progressively lost over time in HIV infection, and CD161 is implicated in the regulation of NKT cell responsiveness. (C) 2009 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the rate of occupational leg swelling depending on the time period of the working day Volumetric variations of the legs of 70 hospital employees, enrolled in three groups, were evaluated. Group I: 35 morning shift workers; Group II: 35 afternoon shift workers; and Group III: 15 individuals randomly selected from Groups I and II, who were evaluated on the day they worked 12 hours consecutively. Volumetry was performed before and after each shift for both legs of the participants in Groups I and II. For Group III volumetry was performed early in the morning, at noon and in the evening, For statistical analysis, the Student`s t-test and Mann-Whitney test were used with an alpha error of 5%. being considered acceptable (P value < 0.05). Significant increases in volume were recorded for the limbs in all three groups (P value < 0.001). On comparing Groups I and II, the accumulation of fluids was significantly higher in the morning than in the afternoon (P value < 0.003). Asymptomatic workers may present with oedema of the legs during their work with the rate of oedema being different for morning and afternoon shifts. The possibility of wearing compression stockings should be considered for this type of work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coaptive thermo coagulation (CTC) for the treatment of stigmata of recent hemorrhage (SRH) in the colon is risky. We evaluated the safety and effectiveness of endoclips in 13 patients with acute lower gastrointestinal bleeding (GIB). Thirty-day re-bleeding and complication rates were comparable to a historical cohort of 41 patients (group 2) who underwent CTC/IE (injection epinephrine) for the management of acute lower GIB. There was no difference in the 30-day re-bleeding rates in the two groups. In group I, immediate hemostasis was successful in all patients. Three of 13 patients (23.1%) developed re-bleeding. In group II, 41 patients from six prior studies underwent CTC and/or IE for the treatment of HRS where 12 (29.3%) developed re-bleeding. There were no immediate complications. Endoclip deployment is as effective as CTC and/or IE for treatment of SRH in the colon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Lower urinary tract symptoms (LUTS) and erectile dysfunction (ED) are common problems in middle-aged and older men. Recently, epidemiologic studies have shown significant associations between severity of LUTS and male sexual dysfunction. Aim. We analyzed the role of prostate enlargement, LUTS, and prostate specific antigen (PSA) levels in the erectile function of Brazilian men who underwent prostate cancer (PCa) screening. Method. We analyzed data from 1,008 consecutive patients enrolled in a PCa screening program. Benign prostatic hyperplasia (BPH) was defined as a prostate weight greater than 30 g as defined by digital rectal examination. For statistical analysis, we used the chi-squared and analysis of variance tests. The odds ratios (OR) for correlation of ED with prostate volume LUTS and PSA were estimated using logistic regression models. Main Outcome Measure. The American Urological Association (AUA) symptom score for LUTS and the International Index of Erectile Function. Results. Mean patient age was 61.2 years (45-87) and median PSA value was 1.9 ng/mL. BPH was identified in 48.5% of patients. Mild, moderate, and severe LUTS were found in 52.3%, 30.9%, and 16.8% of cases, respectively. ED was classified as absent, mild, mild to moderate, moderate, and severe in 18.6%, 23.1%, 18.6%, 15.2%, and 24.5%, respectively. While only 5.4% of the patients with no ED presented severe LUTS, this finding was observed in 27.1% of patients with severe ED (P<0.001). Univariate logistic regression analysis demonstrated that age, prostate volume, AUA symptom score, and PSA levels were significant predictors of ED. However, when controlled for patient age, only LUTS remained as an independent predictor of ED. Conclusions. Controlling for patient age, LUTS are independent risk factors for the development of ED among Brazilian men who undergo PCa screening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies have investigated whether low level laser therapy (LLLT) can optimize human muscle performance in physical exercise. This study tested the effect of LLLT on muscle performance in physical strength training in humans compared with strength training only. The study involved 36 men (20.8 +/- 2.2 years old), clinically healthy, with a beginner and/or moderate physical activity training pattern. The subjects were randomly distributed into three groups: TLG (training with LLLT), TG (training only) and CG (control). The training for TG and TLG subjects involved the leg-press exercise with a load equal to 80% of one repetition maximum (1RM) in the leg-press test over 12 consecutive weeks. The LLLT was applied to the quadriceps muscle of both lower limbs of the TLG subjects immediately after the end of each training session. Using an infrared laser device (808 nm) with six diodes of 60 mW each a total energy of 50.4 J of LLLT was administered over 140 s. Muscle strength was assessed using the 1RM leg-press test and the isokinetic dynamometer test. The muscle volume of the thigh of the dominant limb was assessed by thigh perimetry. The TLG subjects showed an increase of 55% in the 1RM leg-press test, which was significantly higher than the increases in the TG subjects (26%, P = 0.033) and in the CG subjects (0.27%, P < 0.001). The TLG was the only group to show an increase in muscle performance in the isokinetic dynamometry test compared with baseline. The increases in thigh perimeter in the TLG subjects and TG subjects were not significantly different (4.52% and 2.75%, respectively; P = 0.775). Strength training associated with LLLT can increase muscle performance compared with strength training only.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High voltage electrical stimulation has been recommended as a means of accelerating the wound healing process. The effects of high voltage electrical stimulation were evaluated in the treatment of three volunteers with chronic ulcers of the lower limbs. After fifteen weeks of treatment, a reduction was found in the area of all the ulcers, suggesting that high voltage electric stimulation is an effective therapeutic option for chronic ulcers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the intra and interday reliability of surface electromyographic amplitude values of the scapular girdle muscles and upper limbs during 3 isometric closed kinetic chain exercises, involving upper limbs with the fixed distal segment extremity on stable base of support and on a Swiss ball (relatively unstable). Twenty healthy adults performed the exercises push-up, bench-press and wall-press with different effort levels (80% and 100% maximal load). Subjects performed three maximal voluntary contractions (MVC) in muscular testing position of each muscle to obtain a reference value for root mean square (RMS) normalization. Individuals were instructed to randomly perform three isometric contraction series, in which each exercise lasted 6 s with a 2-min resting-period between series and exercises. Intra and interday reliabilities were calculated through the intraclass correlation coefficient (ICC 2.1), standard error of the measurement (SEM). Results indicated an excellent intraday reliability of electromyographic amplitude values (ICC >= 0.75). The interday reliability of normalized RMS values ranged between good and excellent (ICC 0.52-0.98). Finally, it is suggested that the reliability of normalized electromyographic amplitude values of the analyzed muscles present better values during exercises on a stable surface. However, load levels used during the exercises do not seem to have any influence on variability levels, possibly because the loads were quite similar. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the arterial and venous blood flow in women who underwent upper limb axillary dissection surgery for the treatment of breast cancer. Sixty women were divided into two groups: group 1 (G1)-30 women who underwent breast surgery with axillary dissection level II or III (55.6 +/- A 8.6 years); group 2 (G2)-control, 30 women with no breast cancer (57.4 +/- A 7.0 years). Blood flow profile was evaluated by a continuous wave ultrasound Doppler device (Nicolet Vascular Versalab SE(A (R))) with an 8 MHz probe. Axillary, brachial arteries and veins, arm circumference, volumes, and the ankle-brachial index (ABI) were examined. Wilcoxon test and Mann-Whitney tests were applied to analyze blood flow velocity intra-group and between G1 and G2, respectively. The G1 results showed no lymphedema and no peripheral arterial disease (ABI > 0.9). Moreover, the mean blood flow velocity of the vessels ipsilateral to the surgery was significantly higher than the contralateral ones for all vessels examined (P < 0.05). The mean velocity of blood flow of the vessels contralateral to surgery was significantly higher than the axillary artery in G2 (P < 0.05). It can be concluded that women who underwent axillary dissection due to breast cancer showed probable stenosis in the arterial and venous axillary and brachial vessels of the upper limb ipsilateral to the surgery, confirmed by the increase of blood flow velocity, and such obstruction might affect the limb contralateral to the operation site.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wood-dwelling termites are characterized by an extremely high and unique developmental flexibility that allows workers, which are immatures, to explore all caste options. The endocrine signatures underlying this flexibility are only vaguely understood. We determined juvenile hormone (JH) and ecdysteroid hemolymph titers during postembryonic development and in terminal instars of the drywood termite Cryptotermes secundus using field and laboratory colonies. Postembryonic development is characterized by a drop in JH titers at the transition from larval (individuals without wing buds) to nymphal (individuals with wing buds) instars. JH titers were low in winged sexuals and reproducing primary reproductives (< 200 pg/mu l) but were by an order of magnitude higher in neotenic replacement reproductives. The unique regressive molts of termites seem to be characterized by elevated JH titers, compared with progressive or stationary molts. Ecdysteroid titers were generally low in nymphal instars and in primary reproductives (< 50 pg/mu l). It was only during the third and fourth nymphal instars and in winged sexuals where some individuals showed elevated ecdysteroid titers. These results are the most comprehensive endocrinological data set available for any lower termite, with the potential to serve as baseline for understanding the extreme developmental flexibility underlying the evolution of social life in termites.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Limb praxis can be influenced by age, gender, and education. The present Study investigated the influence of these variables on gesture production by healthy elderly Subjects. We evaluated 96 individuals divided into two age groups (60-74 and 75-88 years). Each group contained 48 men and 48 women and was subdivided into four groups according to education: illiterates and 1-3, 4-7, and 8 or more years of education. Individuals were requested to carry Out tasks oil verbal command and imitation. There were no differences between the performance of men and women, while older individuals performed worse than their younger counterparts. Regarding educational level, three major groups emerged: illiterates, individuals with 1-7 years of education, and those with 8 or more years of education. In conclusion, age and education significantly influenced the performance of individuals in limb praxis tests. (JINS, 2009, 157 618-622.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To quantitatively evaluate changes induced by the application of a femoral blood-pressure cuff (BPC) on run-off magnetic resonance angiography (MRA). which is a method generally previously proposed to reduce venous contamination in the leg. Materials and Methods: This study was Health Insurance Portability and Accountability Act (HIPAA)- and Institutional Review Board (IRB)-compliant, We used time-resolved gradient-echo gadolinium (Gd)-enhanced MRA to measure BPC effects on arterial, venous, and soft-tissue enhancement. Seven healthy volunteers (six men) were studied with the BPC applied at the mid-femoral level unilaterally using a 1.5T MR system after intravenous injection of Gd-BOPTA. Different statistical tools were used such as the Wilcoxon signed rank test and a cubic smoothing spline fit. Results: We found that BPC application induces delayed venous filling (as previously described), but also induces significant decreases in arterial inflow, arterial enhancement, vascular-soft tissue contrast, and delayed peak enhancement (which have not been previously measured). Conclusion: The potential benefits from using a BPC for run-off MRA must be balanced against the potential pitfalls, elucidated by our findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the reliability of two- and three-dimensional ultrasonographic measurement of the thickness of the lower uterine segment (LUS) in pregnant women by transvaginal and transabdominal approaches. Methods This was a study of 30 pregnant women who bad bad at least one previous Cesarean section and were between 36 and 39 weeks` gestation, with singleton pregnancies in cephalic presentation. Sonographic examinations were performed by two observers using both 4-7-MHz transabdominal and 5-8-MHz transvaginal volumetric probes. LUS measurements were performed using two- and three-dimensional ultrasound, evaluating the entire LUS thickness transabdominally and the LUS muscular thickness transvaginally. Each observer measured the LUS four times by each method. Reliability was analyzed by comparing the mean of the absolute differences, the intraclass correlation coefficients, the 95% limits of agreement and the proportion of differences <1 mm. Results Transvaginal ultrasound provided greater reliability in LUS measurements than did transabdominal ultrasound. The use of three-dimensional ultrasound improved significantly the reliability of the LUS muscular thickness measurement obtained transvaginally. Conclusions Ultrasonographic measurement of the LUS muscular thickness transvaginally appears more reliable than does that of the entire LUS thickness transabdominally. The use of three-dimensional ultrasound should be considered to improve measurement reliability. Copyright (c) 2009 ISUOG. Published by John Wiley & Sons, Ltd.