929 resultados para low-pressure CVD


Relevância:

30.00% 30.00%

Publicador:

Resumo:

To estimate the possible direct effect of birth weight on blood pressure, it is conventional to condition on the mediator, current weight. Such conditioning can induce bias. Our aim was to assess the potential biasing effect of U, an unmeasured common cause of current weight and blood pressure, on the estimate of the controlled direct effect of birth weight on blood pressure, with the help of sensitivity analyses. We used data from a school-based study conducted in Switzerland in 2005-2006 (n = 3,762; mean age = 12.3 years). A small negative association was observed between birth weight and systolic blood pressure (linear regression coefficient βbw = -0.3 mmHg/kg, 95% confidence interval: -0.9, 0.3). The association was strengthened upon adjustment for current weight (βbw|C = -1.5 mmHg/kg, 95% confidence interval: -2.1, -0.9). Sensitivity analyses revealed that the negative conditional association was explained by U only if U was relatively strongly associated with blood pressure and if there was a large difference in the prevalence of U between low-birth weight and normal-birth weight children. This weakens the hypothesis that the negative relationship between birth weight and blood pressure arises only from collider-stratification bias induced by conditioning on current weight.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Plastic air content is typically tested by the pressure method, ASTM C138. Loss of air content through the paver has been shown to exceed 2 percent at times. Research has shown that early deterioration of pavements in Iowa may be directly or indirectly related to low or inadequate air content. Hardened air content is typically checked using the linear traverse method, ASTM C457. The linear traverse method is very time consuming and could not be used on a production scale. A quick and effective method of testing in place air content is needed. Research has shown a high degree of correlation with the high-pressure method of determining air content of hardened concrete versus plastic air content in laboratory conditions. This research indicated that air contents are more variable when comparing core results to plastic air content, although the overall average for the air content was comparable. Perhaps, the location of the plastic air content test, obtained from construction records, versus location of the cores was not as accurate as needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cardiovascular diseases are the principal cause of death in women in developed countries and are importantly promoted by hypertension. The salt sensitivity of blood pressure (BP) is considered as an important cardiovascular risk factor at any BP level. Preeclampsia is a hypertensive disorder of pregnancy that arises as a risk factor for cardiovascular diseases. This study measured the salt sensitivity of BP in women with a severe preeclampsia compared with women with no pregnancy hypertensive complications. Forty premenopausal women were recruited 10 years after delivery in a case-control study. Salt sensitivity was defined as an increase of >4 mm Hg in 24-hour ambulatory BP on a high-sodium diet. The ambulatory BP response to salt was significantly increased in women with a history of preeclampsia compared with that of controls. The mean (95% confidence interval) daytime systolic/diastolic BP increased significantly from 115 (109-118)/79 (76-82) mm Hg on low-salt diet to 123 (116-130)/80 (76-84) on a high-salt diet in women with preeclampsia, but not in the control group (from 111 [104-119]/77 [72-82] to 111 [106-116]/75 [72-79], respectively, P<0.05). The sodium sensitivity index (SSI=Δmean arterial pressure/Δurinary Na excretion×1000) was 51.2 (19.1-66.2) in women with preeclampsia and 6.6 (5.8-18.1) mm Hg/mol per day in controls (P=0.015). The nocturnal dip was blunted on a high-salt diet in women with preeclampsia. Our study shows that women who have developed preeclampsia are salt sensitive before their menopause, a finding that may contribute to their increased cardiovascular risk. Women with a history of severe preeclampsia should be targeted at an early stage for preventive measures of cardiovascular diseases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS/HYPOTHESIS: To assist in the development of preventive strategies, we studied whether the neighbourhood environment or modifiable behavioural parameters, including cardiorespiratory fitness (CRF) and physical activity (PA), are independently associated with obesity and metabolic risk markers in children. METHODS: We carried out a cross-sectional analysis of 502 randomly selected first and fifth grade urban and rural Swiss schoolchildren with regard to CRF, PA and the neighbourhood (rural vs urban) environment. Outcome measures included BMI, sum of four skinfold thicknesses, homeostasis model assessment of insulin resistance (HOMA-IR) and a standardised clustered metabolic risk score. RESULTS: CRF and PA (especially total PA, but also the time spent engaged in light and in moderate and vigorous intensity PA) were inversely associated with measures of obesity, HOMA-IR and the metabolic risk score, independently of each other, and of sociodemographic and nutritional parameters, media use, sleep duration, BMI and the neighbourhood environment (all p < 0.05). Children living in a rural environment were more physically active and had higher CRF values and reduced HOMA-IR and metabolic risk scores compared with children living in an urban environment (all p < 0.05). These differences in cardiovascular risk factors persisted after adjustment for CRF, total PA and BMI. CONCLUSIONS/INTERPRETATION: Reduced CRF, low PA and an urban environment are independently associated with an increase in metabolic risk markers in children.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigated the changes in both performance and selected physiological parameters following a Live High-Train Low (LHTL) altitude camp in either normobaric hypoxia (NH) or hypobaric hypoxia (HH) replicating current "real" practices of endurance athletes. Well-trained triathletes were split into two groups (NH, n = 14 and HH, n = 13) and completed an 18-d LHTL camp during which they trained at 1100-1200 m and resided at an altitude of 2250 m (PiO2  = 121.7±1.2 vs. 121.4±0.9 mmHg) under either NH (hypoxic chamber; FiO2 15.8±0.8%) or HH (real altitude; barometric pressure 580±23 mmHg) conditions. Oxygen saturations (SpO2) were recorded continuously daily overnight. PiO2 and training loads were matched daily. Before (Pre-) and 1 day after (Post-) LHTL, blood samples, VO2max, and total haemoglobin mass (Hbmass) were measured. A 3-km running test was performed near sea level twice before, and 1, 7, and 21 days following LHTL. During LHTL, hypoxic exposure was lower for the NH group than for the HH group (220 vs. 300 h; P<0.001). Night SpO2 was higher (92.1±0.3 vs. 90.9±0.3%, P<0.001), and breathing frequency was lower in the NH group compared with the HH group (13.9±2.1 vs. 15.5±1.5 breath.min-1, P<0.05). Immediately following LHTL, similar increases in VO2max (6.1±6.8 vs. 5.2±4.8%) and Hbmass (2.6±1.9 vs. 3.4±2.1%) were observed in NH and HH groups, respectively, while 3-km performance was not improved. However, 21 days following the LHTL intervention, 3-km run time was significantly faster in the HH (3.3±3.6%; P<0.05) versus the NH (1.2±2.9%; ns) group. In conclusion, the greater degree of race performance enhancement by day 21 after an 18-d LHTL camp in the HH group was likely induced by a larger hypoxic dose. However, one cannot rule out other factors including differences in sleeping desaturations and breathing patterns, thus suggesting higher hypoxic stimuli in the HH group.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Drug therapy in high-risk individuals has been advocated as an important strategy to reduce cardiovascular disease in low income countries. We determined, in a low-income urban population, the proportion of persons who utilized health services after having been diagnosed as hypertensive and advised to seek health care for further hypertension management. METHODS: A population-based survey of 9254 persons aged 25-64 years was conducted in Dar es Salaam. Among the 540 persons with high blood pressure (defined here as BP >or= 160/95 mmHg) at the initial contact, 253 (47%) had high BP on a 4th visit 45 days later. Among them, 208 were untreated and advised to attend health care in a health center of their choice for further management of their hypertension. One year later, 161 were seen again and asked about their use of health services during the interval. RESULTS: Among the 161 hypertensive persons advised to seek health care, 34% reported to have attended a formal health care provider during the 12-month interval (63% public facility; 30% private; 7% both). Antihypertensive treatment was taken by 34% at some point of time (suggesting poor uptake of health services) and 3% at the end of the 12-month follow-up (suggesting poor long-term compliance). Health services utilization tended to be associated with older age, previous history of high BP, being overweight and non-smoking, but not with education or wealth. Lack of symptoms and cost of treatment were the reasons reported most often for not attending health care. CONCLUSION: Low utilization of health services after hypertension screening suggests a small impact of a patient-centered screen-and-treat strategy in this low-income population. These findings emphasize the need to identify and address barriers to health care utilization for non-communicable diseases in this setting and, indirectly, the importance of public health measures for primary prevention of these diseases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The screening of testosterone (T) misuse for doping control is based on the urinary steroid profile, including T, its precursors and metabolites. Modifications of individual levels and ratio between those metabolites are indicators of T misuse. In the context of screening analysis, the most discriminant criterion known to date is based on the T glucuronide (TG) to epitestosterone glucuronide (EG) ratio (TG/EG). Following the World Anti-Doping Agency (WADA) recommendations, there is suspicion of T misuse when the ratio reaches 4 or beyond. While this marker remains very sensitive and specific, it suffers from large inter-individual variability, with important influence of enzyme polymorphisms. Moreover, use of low dose or topical administration forms makes the screening of endogenous steroids difficult while the detection window no longer suits the doping habit. As reference limits are estimated on the basis of population studies, which encompass inter-individual and inter-ethnic variability, new strategies including individual threshold monitoring and alternative biomarkers were proposed to detect T misuse. The purpose of this study was to evaluate the potential of ultra-high pressure liquid chromatography (UHPLC) coupled with a new generation high resolution quadrupole time-of-flight mass spectrometer (QTOF-MS) to investigate the steroid metabolism after transdermal and oral T administration. An approach was developed to quantify 12 targeted urinary steroids as direct glucuro- and sulfo-conjugated metabolites, allowing the conservation of the phase II metabolism information, reflecting genetic and environmental influences. The UHPLC-QTOF-MS(E) platform was applied to clinical study samples from 19 healthy male volunteers, having different genotypes for the UGT2B17 enzyme responsible for the glucuroconjugation of T. Based on reference population ranges, none of the traditional markers of T misuse could detect doping after topical administration of T, while the detection window was short after oral TU ingestion. The detection ability of the 12 targeted steroids was thus evaluated by using individual thresholds following both transdermal and oral administration. Other relevant biomarkers and minor metabolites were studied for complementary information to the steroid profile, including sulfoconjugated analytes and hydroxy forms of glucuroconjugated metabolites. While sulfoconjugated steroids may provide helpful screening information for individuals with homozygotous UGT2B17 deletion, hydroxy-glucuroconjugated analytes could enhance the detection window of oral T undecanoate (TU) doping.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work was to evaluate the interaction of ultralow oxygen concentrations (ULO) with storage temperatures and carbon dioxide partial pressures and its influence on fruit quality preservation and on the occurrence of physiological disorders in 'Royal Gala' apples. The experiment was carried out in a completely randomized design, with four replicates 25-fruit. ULO conditions (1.0 kPa O2 + 2.0 kPa CO2; 0.8 kPa O2 + 1.5 kPa CO2; 0.8 kPa O2 + 1.0 kPa CO2; 0.6 kPa O2 + 1.5 kPa CO2; and 0.6 kPa O2 + 1.0 kPa CO2) were tested at 0, 0.5 and 1.0°C, in a 5x3 factorial arrangement. Fruit quality and ripening analyses were performed after eight-month storage plus seven days of shelf-life at 20°C. Oxygen partial pressures below 0.8 kPa increased the occurrence of internal breakdown and mealiness. The best ULO condition was 1.0 kPa O2 + plus 2.0 kPa CO2 at 1.0°C. The interaction of ULO conditions and storage temperatures shows the need of increasing O2 partial pressure at higher storage temperatures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The presence of hydrogen in polysilicon films obtained at low temperatures by hot-wire CVD and the post-deposition oxidation by air-exposure of the films are studied in this paper. The experimental results from several characterization techniques (infrared spectroscopy, X-ray photoelectron spectroscopy, secondary ion mass spectrometry and wavelength dispersive spectroscopy) showed that hydrogen and oxygen are homogeneously distributed at grain boundaries throughout the depth of the films. Hydrogen is introduced during the growth process and its concentration is higher in samples deposited at lower temperatures. Oxygen diffuses along the grain boundaries and binds to silicon atoms, mainly in Si 2O groups.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Continuous positive airway pressure, aimed at preventing pulmonary atelectasis, has been used for decades to reduce lung injury in critically ill patients. In neonatal practice, it is increasingly used worldwide as a primary form of respiratory support due to its low cost and because it reduces the need for endotracheal intubation and conventional mechanical ventilation. We studied the anesthetized in vivo rat and determined the optimal circuit design for delivery of continuous positive airway pressure. We investigated the effects of continuous positive airway pressure following lipopolysaccharide administration in the anesthetized rat. Whereas neither continuous positive airway pressure nor lipopolysaccharide alone caused lung injury, continuous positive airway pressure applied following intravenous lipopolysaccharide resulted in increased microvascular permeability, elevated cytokine protein and mRNA production, and impaired static compliance. A dose-response relationship was demonstrated whereby higher levels of continuous positive airway pressure (up to 6 cmH(2)O) caused greater lung injury. Lung injury was attenuated by pretreatment with dexamethasone. These data demonstrate that despite optimal circuit design, continuous positive airway pressure causes significant lung injury (proportional to the airway pressure) in the setting of circulating lipopolysaccharide. Although we would currently avoid direct extrapolation of these findings to clinical practice, we believe that in the context of increasing clinical use, these data are grounds for concern and warrant further investigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To explore the association of short-term exposure to particulate matter with aerodynamic diameters less than 10 μm (PM10) with pulse pressure, SBP, and DBP taking outdoor temperature into account in two large population-based studies in Switzerland. METHODS: We used data from the Bus Santé study including 5605 adults in Geneva and the CoLaus study including 6183 adults in Lausanne. PM10 and meteorological data were measured from fixed monitoring stations. We analyzed the association of short-term exposure to PM10 (on the day of examination visit and up to 7 days before) with pulse pressure, SBP, and DBP by linear regression, controlling for potential confounders and effect modifiers. RESULTS: Average PM10 levels were 22.4 μg/m in Geneva and 31.7 μg/m in Lausanne. In adjusted models, for each 10 μg/m increase in 7-day PM10 average, pulse pressure and SBP increased by 0.583 (95% confidence interval, 0.296-0.870) mmHg and 0.490 (0.056-0.925) mmHg in Geneva, and 0.183 (0.017-0.348) mmHg and 0.036 (0.042-0.561) mmHg in Lausanne, respectively. Stronger associations of pulse pressure and SBP with PM10 were observed when outdoor temperature was above 5°C. CONCLUSION: Positive associations of pulse pressure and SBP with short-term exposure to PM10 were found and replicated in the Swiss adult population. Our results suggest that even low levels of air pollution may substantially impact cardiovascular risk in the general population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of a tantalum wire in hot-wire chemical vapour deposition (HWCVD) has allowed the deposition of dense nanocrystalline silicon at low filament temperatures (1550 °C). A transition in the crystalline preferential orientation from (2 2 0) to (1 1 1) was observed around 1700 °C. Transmission electron microscopy (TEM) images, together with secondary ion mass spectrometry (SIMS) measurements, suggested that no oxidation occurred in materials obtained at low filament temperature due to the high density of the tissue surrounding grain boundaries. A greater concentration of SiH 3 radicals formed at these temperatures seemed to be responsible for the higher density.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clinical experience and experimental data suggest that intradialytic hemodynamic profiles could be influenced by the characteristics of the dialysis membranes. Even within the worldwide used polysulfone family, intolerance to specific membranes was occasionally evoked. The aim of this study was to compare hemodynamically some of the commonly used polysulfone dialyzers in Switzerland. We performed an open-label, randomized, cross-over trial, including 25 hemodialysis patients. Four polysulfone dialyzers, A (Revaclear high-flux, Gambro, Stockholm, Sweden), B (Helixone high-flux, Fresenius), C (Xevonta high-flux, BBraun, Melsungen, Germany), and D (Helixone low-flux, Fresenius, Bad Homburg vor der Höhe, Germany), were compared. The hemodynamic profile was assessed and patients were asked to provide tolerance feedback. The mean score (±SD) subjectively assigned to dialysis quality on a 1-10 scale was A 8.4 ± 1.3, B 8.6 ± 1.3, C 8.5 ± 1.6, D 8.5 ± 1.5. Kt/V was A 1.58 ± 0.30, B 1.67 ± 0.33, C 1.62 ± 0.32, D 1.45 ± 0.31. The low- compared with the high-flux membranes, correlated to higher systolic (128.1 ± 13.1 vs. 125.6 ± 12.1 mmHg, P < 0.01) and diastolic (76.8 ± 8.7 vs. 75.3 ± 9.0 mmHg; P < 0.05) pressures, higher peripheral resistance (1.44 ± 0.19 vs. 1.40 ± 0.18 s × mmHg/mL; P < 0.05) and lower cardiac output (3.76 ± 0.62 vs. 3.82 ± 0.59 L/min; P < 0.05). Hypotension events (decrease in systolic blood pressure by >20 mmHg) were 70 with A, 87 with B, 73 with C, and 75 with D (P < 0.01 B vs. A, 0.05 B vs. C and 0.07 B vs. D). The low-flux membrane correlated to higher blood pressure levels compared with the high-flux ones. The Helixone high-flux membrane ensured the best efficiency. Unfortunately, the very same dialyzer correlated to a higher incidence of hypotensive episodes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eighty percent of the global 17 million deaths due to cardiovascular disease (CVD) occur in low and middle income countries (LMICs). The burden of CVD and other noncommunicable diseases (NCDs) is expected to markedly increase because of the global aging of the population and increasing exposure to detrimental lifestyle-related risk in LMICs. Interventions to reduce four main risks related to modifiable behaviors (tobacco use, unhealthy diet, low physical activity and excess alcohol consumption) are key elements for effective primary prevention of the four main NCDs (CVD, cancer, diabetes and chronic pulmonary disease). These behaviors are best improved through structural interventions (e.g., clean air policy, taxes on cigarettes, new recipes for processed foods with reduced salt and fat, urban shaping to improve mobility, etc.). In addition, health systems in LMICs should be reoriented to deliver integrated cost-effective treatment to persons at high risk at the primary health care level. The full implementation of a small number of highly cost effective, affordable and scalable interventions ("best buys") is likely to be the necessary and sufficient ingredient for curbing NCDs in LMICs. NCDs are both a cause and a consequence of poverty. It is therefore important to frame NCD prevention and control within the broader context of social determinants and development agenda. The recent emphasis on NCDs at a number of health and economic forums (including the September 2011 High Level Meeting on NCDs at the United Nations) provides a new opportunity to move the NCD agenda forward in LMICs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.