986 resultados para linguistic validation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

False identity documents constitute a potential powerful source of forensic intelligence because they are essential elements of transnational crime and provide cover for organized crime. In previous work, a systematic profiling method using false documents' visual features has been built within a forensic intelligence model. In the current study, the comparison process and metrics lying at the heart of this profiling method are described and evaluated. This evaluation takes advantage of 347 false identity documents of four different types seized in two countries whose sources were known to be common or different (following police investigations and dismantling of counterfeit factories). Intra-source and inter-sources variations were evaluated through the computation of more than 7500 similarity scores. The profiling method could thus be validated and its performance assessed using two complementary approaches to measuring type I and type II error rates: a binary classification and the computation of likelihood ratios. Very low error rates were measured across the four document types, demonstrating the validity and robustness of the method to link documents to a common source or to differentiate them. These results pave the way for an operational implementation of a systematic profiling process integrated in a developed forensic intelligence model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this research is to determine whether the nationally calibrated performance models used in the Mechanistic-Empirical Pavement Design Guide (MEPDG) provide a reasonable prediction of actual field performance, and if the desired accuracy or correspondence exists between predicted and monitored performance for Iowa conditions. A comprehensive literature review was conducted to identify the MEPDG input parameters and the MEPDG verification/calibration process. Sensitivities of MEPDG input parameters to predictions were studied using different versions of the MEPDG software. Based on literature review and sensitivity analysis, a detailed verification procedure was developed. A total of sixteen different types of pavement sections across Iowa, not used for national calibration in NCHRP 1-47A, were selected. A database of MEPDG inputs and the actual pavement performance measures for the selected pavement sites were prepared for verification. The accuracy of the MEPDG performance models for Iowa conditions was statistically evaluated. The verification testing showed promising results in terms of MEPDG’s performance prediction accuracy for Iowa conditions. Recalibrating the MEPDG performance models for Iowa conditions is recommended to improve the accuracy of predictions. ****************** Large File**************************

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photopolymerization is commonly used in a broad range of bioapplications, such as drug delivery, tissue engineering, and surgical implants, where liquid materials are injected and then hardened by means of illumination to create a solid polymer network. However, photopolymerization using a probe, e.g., needle guiding both the liquid and the curing illumination, has not been thoroughly investigated. We present a Monte Carlo model that takes into account the dynamic absorption and scattering parameters as well as solid-liquid boundaries of the photopolymer to yield the shape and volume of minimally invasively injected, photopolymerized hydrogels. In the first part of the article, our model is validated using a set of well-known poly(ethylene glycol) dimethacrylate hydrogels showing an excellent agreement between simulated and experimental volume-growth-rates. In the second part, in situ experimental results and simulations for photopolymerization in tissue cavities are presented. It was found that a cavity with a volume of 152  mm3 can be photopolymerized from the output of a 0.28-mm2 fiber by adding scattering lipid particles while only a volume of 38  mm3 (25%) was achieved without particles. The proposed model provides a simple and robust method to solve complex photopolymerization problems, where the dimension of the light source is much smaller than the volume of the photopolymerizable hydrogel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fondements : La recherche sur l'oedème postopératoire consécutif à la chirurgie prothétique du genou est peu développée, notamment en raison de l'absence d'une méthode de mesure adaptée. Une collaboration entre physiothérapeutes et ingénieurs a permis de développer et valider une méthode de mesure innovante et facilement applicable. Les physiothérapeutes ont identifié un besoin clinique, les ingénieurs ont apporté leur savoir technologique, et l'équipe a conjointement élaboré le protocole de mesure et effectué l'étude de validation. Introduction : La bioimpédance est fréquemment utilisée pour évaluer l'oedème par l'analyse d'un signal électrique passant au travers du corps, en extrapolant la résistance théorique à une fréquence égale à zéro (R0). La mesure s'avère fiable et rapide, mais n'a jamais été appliquée et validée pour l'évaluation de l'oedème en chirurgie orthopédique. Objectif : L'objectif de l'étude est de valider la mesure de l'oedème du membre inférieur par bioimpédance, chez des patients ayant bénéficié d'une prothèse totale de genou (PTG). Questionnement : Après nous être assurés de l'absence d'influence de l'implant métallique de la PTG sur la mesure, nous nous questionnions sur la validité et la fiabilité des mesures de bioimpédance dans ce contexte. Méthodes : Deux évaluateurs ont mesuré à tour de rôle et à deux reprises successives l'oedème chez 24 patients opérés d'une PTG, à trois temps différents (préopératoire, J+2, J+8). L'oedème a été évalué par bioimpédance (R0) et par conversion en volume de mesures centimétriques du membre inférieur (MI). Nous avons calculé le ratio moyen des MI pour chaque méthode. Nous avons évalué la reproductibilité intra- et inter-observateurs de la bioimpédance (coefficient de corrélation intraclasse, CCI) et la corrélation entre méthodes (Spearman). Résultats : Le ratio moyen opéré/sain du volume des MI est de 1.04 (SD ± 0.06) en préopératoire, 1.18 (SD ± 0.09) à J+2 et 1.17 (SD ± 0.10) à J+8. Le ratio sain/opéré des MI de R0 est de 1.04 (SD ± 0.07) en préopératoire, 1.51 (SD ± 0.22) à J+2 et 1.65 (SD ± 0.21) à J+8. En préopératoire, à J+2 et J+8, les CCI tous supérieurs à 0.95 pour la reproductibilité intra- et inter-observateurs de la bioimpédance. La corrélation entre méthodes est de 0.71 en préopératoire, 0.61 à J2 et 0.33 à J8. Analyse et conclusion : La variation du ratio des MI entre les temps préopératoire, J+2 et J+8 est plus marquée pour R0. La mesure de bioimpédance bénéficie d'une excellente reproductibilité intra- et inter-observateurs. L'évolution dans le temps de la corrélation entre méthodes peut être expliquée par l'influence potentielle de facteurs confondants sur R0 (modification de la composition liquidienne) et par l'influence de l'atrophie musculaire postopératoire sur la mesure de volume. La collaboration physiothérapeutes-ingénieurs a permis le développement et l'évaluation d'une nouvelle méthode de mesure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to investigate the impact of a communication skills training (CST) in oncology on clinicians' linguistic strategies. A verbal communication analysis software (Logiciel d'Analyse de la Communication Verbale) was used to compare simulated patients interviews with oncology clinicians who participated in CST (N = 57) (pre/post with a 6-month interval) with a control group of oncology clinicians who did not (N = 56) (T1/T2 with a 6-month interval). A significant improvement of linguistic strategies related to biomedical, psychological and social issues was observed. Analysis of linguistic aspects of videotaped interviews might become in the future a part of individualised feedback in CST and utilised as a marker for an evaluation of training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbapenemases should be accurately and rapidly detected, given their possible epidemiological spread and their impact on treatment options. Here, we developed a simple, easy and rapid matrix-assisted laser desorption ionization-time of flight (MALDI-TOF)-based assay to detect carbapenemases and compared this innovative test with four other diagnostic approaches on 47 clinical isolates. Tandem mass spectrometry (MS-MS) was also used to determine accurately the amount of antibiotic present in the supernatant after 1 h of incubation and both MALDI-TOF and MS-MS approaches exhibited a 100% sensitivity and a 100% specificity. By comparison, molecular genetic techniques (Check-MDR Carba PCR and Check-MDR CT103 microarray) showed a 90.5% sensitivity and a 100% specificity, as two strains of Aeromonas were not detected because their chromosomal carbapenemase is not targeted by probes used in both kits. Altogether, this innovative MALDI-TOF-based approach that uses a stable 10-μg disk of ertapenem was highly efficient in detecting carbapenemase, with a sensitivity higher than that of PCR and microarray.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The Marburg Heart Score (MHS) aims to assist GPs in safely ruling out coronary heart disease (CHD) in patients presenting with chest pain, and to guide management decisions. AIM: To investigate the diagnostic accuracy of the MHS in an independent sample and to evaluate the generalisability to new patients. DESIGN AND SETTING: Cross-sectional diagnostic study with delayed-type reference standard in general practice in Hesse, Germany. METHOD: Fifty-six German GPs recruited 844 males and females aged ≥ 35 years, presenting between July 2009 and February 2010 with chest pain. Baseline data included the items of the MHS. Data on the subsequent course of chest pain, investigations, hospitalisations, and medication were collected over 6 months and were reviewed by an independent expert panel. CHD was the reference condition. Measures of diagnostic accuracy included the area under the receiver operating characteristic curve (AUC), sensitivity, specificity, likelihood ratios, and predictive values. RESULTS: The AUC was 0.84 (95% confidence interval [CI] = 0.80 to 0.88). For a cut-off value of 3, the MHS showed a sensitivity of 89.1% (95% CI = 81.1% to 94.0%), a specificity of 63.5% (95% CI = 60.0% to 66.9%), a positive predictive value of 23.3% (95% CI = 19.2% to 28.0%), and a negative predictive value of 97.9% (95% CI = 96.2% to 98.9%). CONCLUSION: Considering the diagnostic accuracy of the MHS, its generalisability, and ease of application, its use in clinical practice is recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of laparoscopic surgery has increased rapidly. However, a technically feasible procedure is not automatically recommendable. Thus, if cholecystectomy and fundoplication are currently fully validated techniques, this does not hold true for gastroplasty and kidney harvesting for transplantation: these operations are feasible indeed but their efficacy remains to be proved. Laparoscopic oncology has been shown to be feasible too, but its efficacy has not been documented yet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Coarctation of the aorta is one of the most common congenital heart defects. Its diagnosis may be difficult in the presence of a patent ductus arteriosus, of other complex defects or of a poor echocardiographic window. We sought to demonstrate that the carotid-subclavian artery index (CSA index) and the isthmus-descending aorta ratio (I/D ratio), two recently described echocardiographic indexes, are effective in detection of isolated and complex aortic coarctations in children younger and older than 3 months of age. The CSA index is the ratio of the distal aortic arch diameter to the distance between the left carotid artery and the left subclavian artery. It is highly suggestive of a coarctation when it is <1.5. The I/D ratio defined as the diameter of the isthmus to the diameter of the descending aorta, suggests an aortic coarctation when it is less than 0.64. METHODS: This is a retrospective cohort study in a tertiary care children's hospital. Review of all echocardiograms in children aged 0-18 years with a diagnosis of coarctation seen at the author's institution between 1996 and 2006. An age- and sex-matched control group without coarctation was constituted. Offline echocardiographic measurements of the aortic arch were performed in order to calculate the CSA index and I/D ratio. RESULTS: Sixty-eight patients were included in the coarctation group, 24 in the control group. Patients with coarctation had a significantly lower CSA index (0.84+/-0.39 vs 2.65+/-0.82, p<0.0001) and I/D ratio (0.58+/-0.18 vs 0.98+/-0.19, p<0.0001) than patients in the control group. Associated cardiac defects and age of the child did not significantly alter the CSA index or the I/D ratio. CONCLUSIONS: A CSA index less than 1.5 is highly suggestive of coarctation independent of age and of the presence of other cardiac defects. I/D ratio alone is less specific than CSA alone at any age and for any associated cardiac lesion. The association of both indexes improves sensitivity and permits diagnosis of coarctation in all patients based solely on a bedside echocardiographic measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Aim: Cocktail approach is generally preferred to individual administration of probes in order to characterize the activity of multiple enzymes. However, cocktail strategy has several drawbacks such as drug-drug interactions, tolerability and toxicity. Hence, there is a need to develop cocktails using low doses of probes. Our aim was to investigate whether the simultaneous oral administration of microdoses of midazolam (MDZ) and dextromethorphan (DEM) can be used to assess the simultaneous activities of CYP3A and CYP2D6. Methods: As part of a 5 arm randomized cross-over control trial on the analgesic efficacy of oxycodone, ten healthy young non-smoking males received the following combinations of drugs: Quinidine (Q)+ ketoconazole (K) or Q+placebo (P) or K+P or P+P. In all cases MDZ (0.075 mg) and DEM (2.5 mg) were administrated 1 hour after Q, K or P. CYP2D6 and CYP3A activities were determined after urine collection during 8 hours (ratio DEM/DOR), and a blood sample (EDTA) after 30 min (ratio 1-OH-MDZ/MDZ). DEM and DOR analysis was performed using LC-fluorescence. MDZ and 1-OH-MDZ determination was performed using GC-MS. Allele's variants of CYP2D6 were detected using the AmpliChipTMCYP450 (Roche). Results: CYP2D6 genotype predicted 1 poor (PM), 1 intermediate (IM), 7 extensive (EM) and 2 ultra rapid (UM) metabolizers. A good correlation was obtained between the predicted and the measured phenotypes except for 1 EM phenotyped as UM. Two duplications for alleles *41/*41xN and *1/*2xN were detected and the two volunteers were phenotyped as UM. A potent inhibition of CYP2D6 or CYP3A4 was obtained when Q or K were used. Mean metabolic ratio DEM/DOR in P and K groups were 0.015 (±0.028) and 0.015 (±0.019). It significantly increased in Q and QK groups (0.668 (±0.676) and 0.743 (±1.038)). Mean 1-OH-MDZ/MDZ in P, Q were 2.73 (±1.05) and 2.55 (±1.40) while it significantly decreased in K and QK groups (0.11 (±0.05), 0.10 (±0.05)). Moreover, there were no statistically significant differences between QK and K sessions for CYP3A and between QK and Q for CYP2D6 which indicate that there is no interaction between the two metabolic pathways. Conclusion: Simultaneous assessment of CYP3A and CYP2D6 activities can be obtained by low oral doses (micro-cocktail) of MDZ and DEM. Specific inhibitors such as Q or K modulates selectively CYP2D6 or CYP3A activities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le but de cette étude est de répondre aux 3 questions suivantes: - 1) Le test de MAST est-il applicable, dans sa traduction française, à la population d'un service de médecine interne d'un hôpital universitaire en Suisse romande ? - 2) Le test de MAST apporte-t-il des résultats concordants avec le diagnostic clinique d'une part, et avec les résultats tirés de la littérature d'autre part ? - 3) De quelles façons peut-on définir et choisir deux valeurs critiques du test afin d'optimaliser l'utilisation du test de MAST dans l'étude comparative projetée ? ANNEXE: Traduction littérale en langue française du : "Michigan Alcoholism Screening Test" (MAST); etc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new non parametric atlas registration framework, derived from the optical flow model and the active contour theory, applied to automatic subthalamic nucleus (STN) targeting in deep brain stimulation (DBS) surgery. In a previous work, we demonstrated that the STN position can be predicted based on the position of surrounding visible structures, namely the lateral and third ventricles. A STN targeting process can thus be obtained by registering these structures of interest between a brain atlas and the patient image. Here we aim to improve the results of the state of the art targeting methods and at the same time to reduce the computational time. Our simultaneous segmentation and registration model shows mean STN localization errors statistically similar to the most performing registration algorithms tested so far and to the targeting expert's variability. Moreover, the computational time of our registration method is much lower, which is a worthwhile improvement from a clinical point of view.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new device for the analyses of nurses' satisfaction has been developed and validated on two types of general and intensive treatments at the University Hospital in Vaudois, Switzerland. A questionnaire has been elaborated for identifying the variables linked with characteristics of the nurse's work, as well as personal variables of the employer which could have an influence on the level of satisfaction. In identifying the sources of satisfaction and dissatisfaction, it has been possible to propose recommendations and corrective measures in order to improve the level of global satisfaction of the nursing team.