999 resultados para iron extraction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim  Background The expected benefit of transvaginal specimen extraction is reduced incision-related morbidity. Objectives A systematic review of transvaginal specimen extraction in colorectal surgery was carried out to assess this expectation. Method  Search strategy The following keywords, in various combinations, were searched: NOSE (natural orifices specimen extraction), colorectal, colon surgery, transvaginal, right hemicolectomy, left hemicolectomy, low anterior resection, sigmoidectomy, ileocaecal resection, proctocolectomy, colon cancer, sigmoid diverticulitis and inflammatory bowel diseases. Selection criteria Selection criteria included large bowel resection with transvaginal specimen extraction, laparoscopic approach, human studies and English language. Exclusion criteria were experimental studies and laparotomic approach or local excision. All articles published up to February 2011 were included. Results  Twenty-three articles (including a total of 130 patients) fulfilled the search criteria. The primary diagnosis was colorectal cancer in 51% (67) of patients, endometriosis in 46% (60) of patients and other conditions in the remaining patients. A concurrent gynaecological procedure was performed in 17% (22) of patients. One case of conversion to laparotomy was reported. In two patients, transvaginal extraction failed. In left- and right-sided resections, the rate of severe complications was 3.7% and 2%, respectively. Two significant complications, one of pelvic seroma and one of rectovaginal fistula, were likely to have been related to transvaginal extraction. The degree of follow up was specified in only one study. Harvested nodes and negative margins were adequate and reported in 70% of oncological cases. Conclusion  Vaginal extraction of a colorectal surgery specimen shows potential benefit, particularly when associated with a gynaecological procedure. Data from prospective randomized trials are needed to support the routine use of this technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The susceptibility of blood changes after administration of a paramagnetic contrast agent that shortens T(1). Concomitantly, the resonance frequency of the blood vessels shifts in a geometry-dependent way. This frequency change may be exploited for incremental contrast generation by applying a frequency-selective saturation prepulse prior to the imaging sequence. The dual origin of vascular enhancement depending first on off-resonance and second on T(1) lowering was investigated in vitro, together with the geometry dependence of the signal at 3T. First results obtained in an in vivo rabbit model are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Le glaucome à angle ouvert est une neuropathie optique chronique progressive pour laquelle de nombreux traitements tant médicaux que chirurgicaux ont été proposés. La prise en charge chirurgicale s'articule principalement autour de deux chirurgies filtrantes, la trabéculectomie et la sclérectomie profonde avec implant de collagène. Cependant, les complications postopératoires de ces deux interventions étant relativement fréquentes, la recherche s'est orientée vers des traitements alternatifs dont la mise en place de micro-drains. Ces implants de drainage diminuent la pression intraoculaire en créant un court-circuit du flux d'humeur aqueuse de la chambre antérieure vers l'espace sous-conjonctival avec formation d'une bulle de filtration. L'implant Ex-PRESS R-50 est un implant miniature (2.5 mm de long pour 400 µm de diamètre) en acier inoxydable et biocompatible. La présente étude s'est proposée d'étudier l'efficacité et la sécurité de l'implant miniature Ex-Press R-50 lors d'une opération combinée cataracte-glaucome. Trente-cinq yeux de 35 patients (âge moyen: 75 ans) ont été inclus dans l'étude. Tous les patients ont bénéficié d'une opération de la cataracte par phacoemulsification et mise en place d'un implant de chambre postérieure suivie de l'implantation du micro-drain. Les pressions intraoculaires préopératoires et postopératoires, la meilleure acuité visuelle corrigée, le nombre de médicaments anti-glaucomateux ainsi que le type et le nombre de complications ont été évalués mensuellement puis tous les 6 mois pendant 4 ans. Le succès total a été défini par une pression postopératoire finale inférieure à 18mmHg sans traitement médical associé, le succès partiel par une pression postopératoire finale inférieure à 18mmHg avec ou sans traitement médical associé.. Le suivi moyen a été de 36.9 mois avec une baisse de la pression intraoculaire significative d'environ 25%. Une augmentation de l'acuité visuelle a été observée après l'opération de la cataracte et le nombre de médicaments anti-glaucomateux a été réduit de 57%. Dix patients ont bénéficié d'un traitement supplémentaire de la bulle de filtration par injection d'anti-métabolite (mitomycine C). Nous avons observé 8 complications majeures (4 érosions conjonctivales et 4 obstructions de l'orifice interne du micro-drain), toutes suivies de l'ablation de l'implant et de la réalisation d'une chirurgie classique du glaucome. En se basant sur les courbes de Kaplan-Meier à 48 mois, le taux de succès total était de 32.7% et le succès partiel de 53.7%. Nous pouvons conclure suite à ce travail que l'implant miniature Ex-PRESS R-50 est associé à un nombre trop élevé de complications, même si les cas non compliqués ont bénéficié d'une baisse significative de la pression intraoculaire. La modification de l'architecture du micro-drain ainsi que de la technique chirurgicale devrait augmenter le taux de succès.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Efficacy of iron therapy, whether oral or intravenous, on biological markers of body iron stores is well recognized in medical literature, but current studies are heterogeneous, of sometimes dubious quality, and rarely address clinical outcomes. Precise practical guidelines appear available only for indications related to kidney disease. First-line intravenous use is reserved for situations comprising chronic renal failure, or patients presenting with malabsorption syndromes such as in inflammatory bowel disease. In all other situations, because of the non-negligible risk of hypersensitivity reactions, intravenous iron use is considered justified only in clinically sustained indications, for patients in whom oral administration of iron is unsatisfactory or impossible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Colonoscopy is usually proposed for the evaluation of lower gastrointestinal blood loss (hematochezia) or iron deficiency anemia (IDA). Clinical practice guidelines support this approach but formal evidence is lacking. Real clinical scenarios made available on the web would be of great help in decision-making in clinical practice as to whether colonoscopy is appropriate for a given patient. Method: A multidisciplinary multinational expert panel (EPAGE II) developed appropriateness criteria based on best published evidence (systematic reviews, clinical trials, guidelines) and experts' judgement. Using the explicit RAND Appropriateness Method (3 round of experts' votes and a panel meeting) 102 clinical scenarios were judged inappropriate, uncertain, appropriate, or necessary. Results: In IDA, colonoscopy was appropriate in patients >50 years and necessary in the presence of lower abdominal symptoms. In both men and women aged <50 years, colonoscopy was appropriate if prior sigmoidoscopy and/or gastroscopy did not explain the IDA, and necessary if lower gastrointestinal symptoms were present. In women <50 years with a potential gynecological cause, additional lower gastrointestinal symptoms rendered colonoscopy appropriate. In patients >50 years with hematochezia, colonoscopy was always appropriate and mostly necessary, except if a prior colonoscopy was normal within the previous 5 years. Under age 50 years, the presence of any risk factor for colorectal cancer (CRC) and no previous normal colonoscopy (within the last 5 years) made this procedure appropriate and necessary. Conclusion: Colonoscopy is appropriate and even necessary for many indications related to iron deficiency anemia or hematochezia, in particular in patients aged >50 years. The main factors influencing appropriateness are age, results of prior investigations (sigmoidoscopy, gastroscopy, previous colonoscopy), CRC risk and sex. EPAGE II appropriateness criteria are available on www.epage.ch

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capillary electrophoresis has drawn considerable attention in the past few years, particularly in the field of chiral separations because of its high separation efficiency. However, its routine use in therapeutic drug monitoring is hampered by its low sensitivity due to a short optical path. We have developed a capillary zone electrophoresis (CZE) method using 2mM of hydroxypropyl-β-cyclodextrin as a chiral selector, which allows base-to-base separation of the enantiomers of mianserin (MIA), desmethylmianserin (DMIA), and 8-hydroxymianserin (OHMIA). Through the use of an on-column sample concentration step after liquid-liquid extraction from plasma and through the presence of an internal standard, the quantitation limits were found to be 5 ng/mL for each enantiomer of MIA and DMIA and 15 ng/mL for each enantiomer of OHMIA. To our knowledge, this is the first published CE method that allows its use for therapeutic monitoring of antidepressants due to its sensitivity down to the low nanogram range. The variability of the assays, as assessed by the coefficients of variation (CV) measured at two concentrations for each substance, ranged from 2 to 14% for the intraday (eight replicates) and from 5 to 14% for the interday (eight replicates) experiments. The deviations from the theoretical concentrations, which represent the accuracy of the method, were all within 12.5%. A linear response was obtained for all compounds within the range of concentrations used for the calibration curves (10-150 ng/mL for each enantiomer of MIA and DMIA and 20-300 ng/mL for each enantiomer of OHMIA). Good correlations were calculated between [(R) + (S)]-MIA and DMIA concentrations measured in plasma samples of 20 patients by a nonchiral gas chromatography method and CZE, and between the (R)- and (S)-concentrations of MIA and DMIA measured in plasma samples of 37 patients by a previously described chiral high-performance liquid chromatography method and CZE. Finally, no interference was noted from more than 20 other psychotropic drugs. Thus, this method, which is both sensitive and selective, can be routinely used for therapeutic monitoring of the enantiomers of MIA and its metabolites. It could be very useful due to the demonstrated interindividual variability of the stereoselective metabolism of MIA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to detect fluctuations in ruminal microbial populations due to forage tannins using 16S ribosomal RNA (rRNA) probes, recovery of intact rRNA is required. The objective of this work was to evaluate the effect of polyethylene glycol (PEG) and polyvinylpirrolidone (PVP) on extraction of bacterial rRNA, in the presence of tannins from tropical legume forages and other sources, that hybridize with oligonucleotide probes. Ruminococcus albus 8 cells were exposed to 8 g/L tannic acid or 1 g/L condensed tannins extracted from Acacia angustissima, banana (Musa sp.) skin, Desmodium ovalifolium, red grape (Vitis vinifera) skin and Inga edulis, or no tannins. Cells were rinsed with Tris buffer pH 7 containing either 8% PEG or 6% PVP prior to cell lysis. Total RNA samples rinsed with either PEG or PVP migrated through denaturing agarose gels. The 16S rRNA bands successfully hybridized with a R. albus species-specific oligonucleotide probe, regardless of tannin source. The effect of rinsing buffers on the density of 16S rRNA bands, as well as on the hybridization signals was compared. There were significant effects (P<0.01) when the controls were compared to either buffer treatments due to tannin type, buffer used and the interaction of tannin type and buffer. The significant interaction indicates the influence of tannin type on the parameters evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of magnetic nanoparticles is intimately entwined with their structure, mean size and magnetic anisotropy. Besides, ensembles offer a unique way of engineering the magnetic response by modifying the strength of the dipolar interactions between particles. Here we report on an experimental and theoretical analysis of magnetic hyperthermia, a rapidly developing technique in medical research and oncology. Experimentally, we demonstrate that single-domain cubic iron oxide particles resembling bacterial magnetosomes have superior magnetic heating efficiency compared to spherical particles of similar sizes. Monte Carlo simulations at the atomic level corroborate the larger anisotropy of the cubic particles in comparison with the spherical ones, thus evidencing the beneficial role of surface anisotropy in the improved heating power. Moreover we establish a quantitative link between the particle assembling, the interactions and the heating properties. This knowledge opens new perspectives for improved hyperthermia, an alternative to conventional cancer therapies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS: To summarize the published literature on assessment of appropriateness of colonoscopy for the investigation of iron-deficiency anemia (IDA) and hematochezia, and report appropriateness criteria developed by an expert panel, the 2008 European Panel on the Appropriateness of Gastrointestinal Endoscopy, EPAGE II. METHODS: A systematic search of guidelines, systematic reviews and primary studies regarding the evaluation and management of IDA and hematochezia was performed. The RAND/UCLA Appropriateness Method was applied to develop appropriateness criteria for colonoscopy for these conditions. RESULTS: IDA occurs in 2 %-5 % of adult men and postmenopausal women. Examination of both the upper and lower gastrointestinal tract is recommended in patients with iron deficiency. Colonoscopy for IDA yields one colorectal cancer (CRC) in every 9-13 colonoscopies. Hematochezia is a well-recognized alarm symptom and such patients are likely to be referred for colonoscopy. Colonoscopy is unanimously recommended in patients aged > or = 50. Diverticulosis, vascular ectasias, and ischemic colitis are common causes of acute lower gastrointestinal bleeding (LGIB); CRC is found in 0.2 %-11 % of the colonoscopies performed for LGIB. Most patients with scant hematochezia have an anorectal or a distal source of bleeding. The expert panel considered most clinical indications for colonoscopy as appropriate in the presence of IDA (58 %) or hematochezia (83 %). CONCLUSION: Despite the limitations of the published studies, guidelines unanimously recommend colonoscopy for the investigation of IDA and hematochezia in patients aged > or = 50 years. These indications were also considered appropriate by EPAGE II, as were indications in patients at low risk for CRC with no obvious cause of bleeding found during adequate previous investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iron deficiency is generally investigated when faced with anemia, or with symptoms that could be related to iron deficiency without anemia. This simple disorder is easy to treat, provided that the diagnosis is correct. Several biological tests are available, but their interpretation is oftentimes problematic. Pre-analytical factors can interfere with measurements, normal values can change depending on suppliers, and, above all, results from different markers can be contradictory in some clinical situations. The aim of this article is to evaluate how the evolution of scientific knowledge and clinical trials can contribute to a better understanding and greater reliability in the diagnosis of iron deficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: oscillatory activity, which can be separated in background and oscillatory burst pattern activities, is supposed to be representative of local synchronies of neural assemblies. Oscillatory burst events should consequently play a specific functional role, distinct from background EEG activity – especially for cognitive tasks (e.g. working memory tasks), binding mechanisms and perceptual dynamics (e.g. visual binding), or in clinical contexts (e.g. effects of brain disorders). However extracting oscillatory events in single trials, with a reliable and consistent method, is not a simple task. Results: in this work we propose a user-friendly stand-alone toolbox, which models in a reasonable time a bump time-frequency model from the wavelet representations of a set of signals. The software is provided with a Matlab toolbox which can compute wavelet representations before calling automatically the stand-alone application. Conclusion: The tool is publicly available as a freeware at the address: http:// www.bsp.brain.riken.jp/bumptoolbox/toolbox_home.html