990 resultados para introductory physics course


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seven regional networking events, aimed at supporting and developing ‘early stage’ novice university bioscience teachers were held across the UK. These workshops allowed 230 participants to reflect on teaching styles, learn about Higher Education Academy resources and discuss strategies to deal with a range of teaching situations. Post-event feedback was sought, and the results are presented in this paper. Feedback on the events was overwhelmingly positive, highlighting the need for such events to support the development of new teachers in higher education. Institutional training varies and these opportunities for sharing experiences, asking questions, networking and reflection on teaching practice were highly regarded. Most participants felt more confident about their teaching and believed that students were more directly engaged in their teaching after attending the events. Recommendations for support of this category of teacher include provision of discipline-specific events, opportunity for local area networking and support for the development of reflective practice in teaching and learning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thomas, L., Ratcliffe, M., Woodbury, J., and Jarman, E. 2002. Learning styles and performance in the introductory programming sequence. SIGCSE Bull. 34, 1 (Mar. 2002), 33-37.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lloyd, Noel G., and Pearson, Jane M., 'Space saving calculation of symbolic resultants', Mathematics in Computer Science, 1 (2007), 267-290.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This module will introduce the item submission workflows available in DSpace. Workflows allow submissions to be checked before entering the repository. Submissions may be checked for accuracy, in order to improve the metadata, or simply to decide if they are OK to be archived. The module will show the three workflow steps available in DSpace, along with details about adding, changing and removing them from the submission process of collections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis is a study of Konrad Bayer's dramatic texts. It has evolved out of various attempts to read those texts, some filed and some more successful. It does not claim to be authoritative or complete, since the nature of Bayer's texts, as will become clear in the course of the ensuing chapters, means that they resist such an interpretation. To accept this was an important prerequisite for the writing of this thesis, but a difficult one to fulfill because for the Bayer commentator it constitutes a certain acceptance of defeat even before one begins. Chapter 1 will begin by providing some introductory information about Konrad Bayer, including details of his life and his membership of the Wiener Gruppe, a formative phase in his development as a writer. It will also consider the historical and cultural climate of 1950s Austria that provided the backdrop for Bayer's literary work. The phenomenon of the Wiener Gruppe will then be examined against the background of preceding experimental movements, for the purpose of situating Bayer's work historically and artistically. The aim of this historical and artistic survey is to prepare for the confrontation with Bayer's texts that makes up the other chapters of the thesis. Chapter 2 will constitute a close textual study of one of Bayer's dramatic texts using criteria from the field of text linguistics. Such a study will offer an entry point into Bayer's texts and will supply material which will form the basis for the interpretative investigations of the chapters that follow it. Chapter 3 will consider the influence of language and the individual. In chapter 4 the figure of the Lion of Belfort, a recurring figure in Bayer's dramatic texts, is discussed. The final chapter of this thesis will examine the recurring motifs of violence and cannibalism and will consider them in terms of the findings of preceding chapters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In a time-course microarray experiment, the expression level for each gene is observed across a number of time-points in order to characterize the temporal trajectories of the gene-expression profiles. For many of these experiments, the scientific aim is the identification of genes for which the trajectories depend on an experimental or phenotypic factor. There is an extensive recent body of literature on statistical methodology for addressing this analytical problem. Most of the existing methods are based on estimating the time-course trajectories using parametric or non-parametric mean regression methods. The sensitivity of these regression methods to outliers, an issue that is well documented in the statistical literature, should be of concern when analyzing microarray data. RESULTS: In this paper, we propose a robust testing method for identifying genes whose expression time profiles depend on a factor. Furthermore, we propose a multiple testing procedure to adjust for multiplicity. CONCLUSIONS: Through an extensive simulation study, we will illustrate the performance of our method. Finally, we will report the results from applying our method to a case study and discussing potential extensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examined the frequency and impact of exposure to potentially traumatic events among a nonclinical sample of older adults (n = 3,575), a population typically underrepresented in epidemiological research concerning the prevalence of traumatic events. Current PTSD symptom severity and the centrality of events to identity were assessed for events nominated as currently most distressing. Approximately 90% of participants experienced one or more potentially traumatic events. Events that occurred with greater frequency early in the life course were associated with more severe PTSD symptoms compared to events that occurred with greater frequency during later decades. Early life traumas, however, were not more central to identity. Results underscore the differential impact of traumatic events experienced throughout the life course. We conclude with suggestions for further research concerning mechanisms that promote the persistence of post-traumatic stress related to early life traumas and empirical evaluation of psychotherapeutic treatments for older adults with PTSD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The outcomes for both (i) radiation therapy and (ii) preclinical small animal radio- biology studies are dependent on the delivery of a known quantity of radiation to a specific and intentional location. Adverse effects can result from these procedures if the dose to the target is too high or low, and can also result from an incorrect spatial distribution in which nearby normal healthy tissue can be undesirably damaged by poor radiation delivery techniques. Thus, in mice and humans alike, the spatial dose distributions from radiation sources should be well characterized in terms of the absolute dose quantity, and with pin-point accuracy. When dealing with the steep spatial dose gradients consequential to either (i) high dose rate (HDR) brachytherapy or (ii) within the small organs and tissue inhomogeneities of mice, obtaining accurate and highly precise dose results can be very challenging, considering commercially available radiation detection tools, such as ion chambers, are often too large for in-vivo use.

In this dissertation two tools are developed and applied for both clinical and preclinical radiation measurement. The first tool is a novel radiation detector for acquiring physical measurements, fabricated from an inorganic nano-crystalline scintillator that has been fixed on an optical fiber terminus. This dosimeter allows for the measurement of point doses to sub-millimeter resolution, and has the ability to be placed in-vivo in humans and small animals. Real-time data is displayed to the user to provide instant quality assurance and dose-rate information. The second tool utilizes an open source Monte Carlo particle transport code, and was applied for small animal dosimetry studies to calculate organ doses and recommend new techniques of dose prescription in mice, as well as to characterize dose to the murine bone marrow compartment with micron-scale resolution.

Hardware design changes were implemented to reduce the overall fiber diameter to <0.9 mm for the nano-crystalline scintillator based fiber optic detector (NanoFOD) system. Lower limits of device sensitivity were found to be approximately 0.05 cGy/s. Herein, this detector was demonstrated to perform quality assurance of clinical 192Ir HDR brachytherapy procedures, providing comparable dose measurements as thermo-luminescent dosimeters and accuracy within 20% of the treatment planning software (TPS) for 27 treatments conducted, with an inter-quartile range ratio to the TPS dose value of (1.02-0.94=0.08). After removing contaminant signals (Cerenkov and diode background), calibration of the detector enabled accurate dose measurements for vaginal applicator brachytherapy procedures. For 192Ir use, energy response changed by a factor of 2.25 over the SDD values of 3 to 9 cm; however a cap made of 0.2 mm thickness silver reduced energy dependence to a factor of 1.25 over the same SDD range, but had the consequence of reducing overall sensitivity by 33%.

For preclinical measurements, dose accuracy of the NanoFOD was within 1.3% of MOSFET measured dose values in a cylindrical mouse phantom at 225 kV for x-ray irradiation at angles of 0, 90, 180, and 270˝. The NanoFOD exhibited small changes in angular sensitivity, with a coefficient of variation (COV) of 3.6% at 120 kV and 1% at 225 kV. When the NanoFOD was placed alongside a MOSFET in the liver of a sacrificed mouse and treatment was delivered at 225 kV with 0.3 mm Cu filter, the dose difference was only 1.09% with use of the 4x4 cm collimator, and -0.03% with no collimation. Additionally, the NanoFOD utilized a scintillator of 11 µm thickness to measure small x-ray fields for microbeam radiation therapy (MRT) applications, and achieved 2.7% dose accuracy of the microbeam peak in comparison to radiochromic film. Modest differences between the full-width at half maximum measured lateral dimension of the MRT system were observed between the NanoFOD (420 µm) and radiochromic film (320 µm), but these differences have been explained mostly as an artifact due to the geometry used and volumetric effects in the scintillator material. Characterization of the energy dependence for the yttrium-oxide based scintillator material was performed in the range of 40-320 kV (2 mm Al filtration), and the maximum device sensitivity was achieved at 100 kV. Tissue maximum ratio data measurements were carried out on a small animal x-ray irradiator system at 320 kV and demonstrated an average difference of 0.9% as compared to a MOSFET dosimeter in the range of 2.5 to 33 cm depth in tissue equivalent plastic blocks. Irradiation of the NanoFOD fiber and scintillator material on a 137Cs gamma irradiator to 1600 Gy did not produce any measurable change in light output, suggesting that the NanoFOD system may be re-used without the need for replacement or recalibration over its lifetime.

For small animal irradiator systems, researchers can deliver a given dose to a target organ by controlling exposure time. Currently, researchers calculate this exposure time by dividing the total dose that they wish to deliver by a single provided dose rate value. This method is independent of the target organ. Studies conducted here used Monte Carlo particle transport codes to justify a new method of dose prescription in mice, that considers organ specific doses. Monte Carlo simulations were performed in the Geant4 Application for Tomographic Emission (GATE) toolkit using a MOBY mouse whole-body phantom. The non-homogeneous phantom was comprised of 256x256x800 voxels of size 0.145x0.145x0.145 mm3. Differences of up to 20-30% in dose to soft-tissue target organs was demonstrated, and methods for alleviating these errors were suggested during whole body radiation of mice by utilizing organ specific and x-ray tube filter specific dose rates for all irradiations.

Monte Carlo analysis was used on 1 µm resolution CT images of a mouse femur and a mouse vertebra to calculate the dose gradients within the bone marrow (BM) compartment of mice based on different radiation beam qualities relevant to x-ray and isotope type irradiators. Results and findings indicated that soft x-ray beams (160 kV at 0.62 mm Cu HVL and 320 kV at 1 mm Cu HVL) lead to substantially higher dose to BM within close proximity to mineral bone (within about 60 µm) as compared to hard x-ray beams (320 kV at 4 mm Cu HVL) and isotope based gamma irradiators (137Cs). The average dose increases to the BM in the vertebra for these four aforementioned radiation beam qualities were found to be 31%, 17%, 8%, and 1%, respectively. Both in-vitro and in-vivo experimental studies confirmed these simulation results, demonstrating that the 320 kV, 1 mm Cu HVL beam caused statistically significant increased killing to the BM cells at 6 Gy dose levels in comparison to both the 320 kV, 4 mm Cu HVL and the 662 keV, 137Cs beams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the analysis of industrial processes, there is an increasing emphasis on systems governed by interacting continuum phenomena. Mathematical models of such multi-physics processes can only be achieved for practical simulations through computational solution procedures—computational mechanics. Examples of such multi-physics systems in the context of metals processing are used to explore some of the key issues. Finite-volume methods on unstructured meshes are proposed as a means to achieve efficient rapid solutions to such systems. Issues associated with the software design, the exploitation of high performance computers, and the concept of the virtual computational-mechanics modelling laboratory are also addressed in this context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper a computer simulation tool capable of modelling multi-physics processes in complex geometry has been developed and applied to the casting process. The quest for high-quality complex casting components demanded by the aerospace and automobile industries, requires more precise numerical modelling techniques and one that need to be generic and modular in its approach to modelling multi-processes problems. For such a computer model to be successful in shape casting, the complete casting process needs to be addressed, the major events being:-• Filling of hot liquid metal into a cavity mould • Solidification and latent heat evolution of liquid metal • Convection currents generated in liquid metal by thermal gradients • Deformation of cast and stress development in solidified metal • Macroscopic porosity formation The above phenomena combines the analysis of fluid flow, heat transfer, change of phase and thermal stress development. None of these events can be treated in isolation as they inexorably interact with each other in a complex way. Also conditions such as design of running system, location of feeders and chills, moulding materials and types of boundary conditions can all affect on the final cast quality and must be appropriately represented in the model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A brief description of a software environment in FORTRAN77 for the modelling of multi-physics phenomena is given. The numerical approach is based on finite volume methods but extended to unstructured meshes (ie. FV-UM). A range of interacting solution procedures for turbulent fluid flow, heat transfer with solidification/melting and elasto-visco-plastic solid mechanics are implemented in the first version of PHYSICA, which will be released in source code form to the academic community in late 1995.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The demands of the process of engineering design, particularly for structural integrity, have exploited computational modelling techniques and software tools for decades. Frequently, the shape of structural components or assemblies is determined to optimise the flow distribution or heat transfer characteristics, and to ensure that the structural performance in service is adequate. From the perspective of computational modelling these activities are typically separated into: • fluid flow and the associated heat transfer analysis (possibly with chemical reactions), based upon Computational Fluid Dynamics (CFD) technology • structural analysis again possibly with heat transfer, based upon finite element analysis (FEA) techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Procedures are described for solving the equations governing a multi-physics process. Finite volume techniques are used to discretise, using the same unstructured mesh, the equations of fluid flow, heat transfer with solidification, and solid deformation. These discretised equations are then solved in an integrated manner. The computational mechanics environment, PHYSICA, which facilitates the building of multi-physics models, is described. Comparisons between model predictions and experimental data are presented for the casting of metal components.