We present a novel filtering method for multispectral satellite image classification. The proposed method learns a set of spatial filters that maximize class separability of binary support vector machine (SVM) through a gradient descent approach. Regularization issues are discussed in detail and a Frobenius-norm regularization is proposed to efficiently exclude uninformative filters coefficients. Experiments carried out on multiclass one-against-all classification and target detection show the capabilities of the learned spatial filters.
Resumo:
BACKGROUND: Collateral damage to upper eyelid margin during proton beam radiotherapy (PBR) for choroidal melanoma may cause squamous metaplasia of the tarsal conjunctiva with keratinisation, corneal irritation, discomfort and, rarely, corneal perforation. We evaluated transpalpebral PBR as a means of avoiding collateral damage to the upper eyelid margin without increasing the risk of failure of local tumour control. METHODS: Retrospective study of consecutive patients who underwent PBR for choroidal melanoma between 1992 and 2007 at the Royal Liverpool University Hospital and the Douglas Cyclotron at Clatterbridge Cancer Centre, UK. RESULTS: Sixty-three patients were included in this study. Mean basal tumour diameter and tumour thickness were 11.8 mm and 3.6 mm, respectively. PBR mean beam range and modulation were 26.5 mm and 16.9 mm respectively. The eyelid margin was included in the radiation field in 15 (24%) eyes. The median follow-up was 2.5 years. Local tumour recurrence developed in 2 (3.2%) patients. In these two cases that developed tumour recurrence the transpalpebral treatment did not involve the eyelid margin. Six (9.5%) patients died of metastatic disease. No eyelid or ocular surface problems developed in any of the 48 patients who were treated without eyelid rim involvement, while 7 of the 15 patients with unavoidable irradiation of the eyelid rim developed some degree of madarosis. These seven patients all received more than 26.55 proton Gy to the eyelid margin. Symptoms, such as grittiness occurred in 12% of 48 patients without eyelid margin irradiation as compared with 53% of 15 patients whose lid margin was irradiated. CONCLUSIONS: Transpalpebral PBR of choroidal melanoma avoids eyelid and ocular surface complications without increasing failure of local tumour control.
Resumo:
Iterative image reconstruction algorithms provide significant improvements over traditional filtered back projection in computed tomography (CT). Clinically available through recent advances in modern CT technology, iterative reconstruction enhances image quality through cyclical image calculation, suppressing image noise and artifacts, particularly blooming artifacts. The advantages of iterative reconstruction are apparent in traditionally challenging cases-for example, in obese patients, those with significant artery calcification, or those with coronary artery stents. In addition, as clinical use of CT has grown, so have concerns over ionizing radiation associated with CT examinations. Through noise reduction, iterative reconstruction has been shown to permit radiation dose reduction while preserving diagnostic image quality. This approach is becoming increasingly attractive as the routine use of CT for pediatric and repeated follow-up evaluation grows ever more common. Cardiovascular CT in particular, with its focus on detailed structural and functional analyses, stands to benefit greatly from the promising iterative solutions that are readily available.
Resumo:
Between April 1981 and June 1985, 195 patients with ovarian cancer, International Federation of Gynecology and Obstetrics (FIGO) Stages IIB, IIC, III, and IV, entered a trial that consisted of surgery and chemotherapy with cisplatin (P) and melphalan (PAM) with or without hexamethylmelamine (HexaPAMP or PAMP regimens) every 4 weeks for 6 cycles. Because the intent was to study the outcome by treatment after evaluation of first-line chemotherapy, patients were evaluable only if the response was assessed by a second-look operation or if measurable disease progression was documented. One hundred fifty-eight patients (81%) were evaluable for response. Forty-five (28%) achieved pathologically confirmed complete remissions (pCR), and 24 of these patients received whole-abdominal radiation (WAR) for consolidation of response. Five patients with complete remission after WAR relapsed, as did nine of the 21 with complete remission who had not undergone WAR. The 3-year time to progression percentage (TTP +/- SE) from second-look operation was 70% +/- 7% for all patients who achieved pCR, 83% +/- 8% for those who received WAR, and 49% +/- 15% for those who did not receive WAR (this was not a randomized comparison). The 3-year TTP percentage for the 49 partial responders was 21% +/- 6%, identical for the 19 who had WAR and the 30 who had no radiation therapy. Additional or alternative methods for consolidation of pCR are needed since patients continue to relapse despite optimal initial response to therapy.
Resumo:
Measurement of arterial input function is a restrictive aspect for quantitative (18)F-FDG PET studies in rodents because of their small total blood volume and the related difficulties in withdrawing blood.
Resumo:
BACKGROUND: The yeast Schizosaccharomyces pombe is frequently used as a model for studying the cell cycle. The cells are rod-shaped and divide by medial fission. The process of cell division, or cytokinesis, is controlled by a network of signaling proteins called the Septation Initiation Network (SIN); SIN proteins associate with the SPBs during nuclear division (mitosis). Some SIN proteins associate with both SPBs early in mitosis, and then display strongly asymmetric signal intensity at the SPBs in late mitosis, just before cytokinesis. This asymmetry is thought to be important for correct regulation of SIN signaling, and coordination of cytokinesis and mitosis. In order to study the dynamics of organelles or large protein complexes such as the spindle pole body (SPB), which have been labeled with a fluorescent protein tag in living cells, a number of the image analysis problems must be solved; the cell outline must be detected automatically, and the position and signal intensity associated with the structures of interest within the cell must be determined. RESULTS: We present a new 2D and 3D image analysis system that permits versatile and robust analysis of motile, fluorescently labeled structures in rod-shaped cells. We have designed an image analysis system that we have implemented as a user-friendly software package allowing the fast and robust image-analysis of large numbers of rod-shaped cells. We have developed new robust algorithms, which we combined with existing methodologies to facilitate fast and accurate analysis. Our software permits the detection and segmentation of rod-shaped cells in either static or dynamic (i.e. time lapse) multi-channel images. It enables tracking of two structures (for example SPBs) in two different image channels. For 2D or 3D static images, the locations of the structures are identified, and then intensity values are extracted together with several quantitative parameters, such as length, width, cell orientation, background fluorescence and the distance between the structures of interest. Furthermore, two kinds of kymographs of the tracked structures can be established, one representing the migration with respect to their relative position, the other representing their individual trajectories inside the cell. This software package, called "RodCellJ", allowed us to analyze a large number of S. pombe cells to understand the rules that govern SIN protein asymmetry. CONCLUSIONS: "RodCell" is freely available to the community as a package of several ImageJ plugins to simultaneously analyze the behavior of a large number of rod-shaped cells in an extensive manner. The integration of different image-processing techniques in a single package, as well as the development of novel algorithms does not only allow to speed up the analysis with respect to the usage of existing tools, but also accounts for higher accuracy. Its utility was demonstrated on both 2D and 3D static and dynamic images to study the septation initiation network of the yeast Schizosaccharomyces pombe. More generally, it can be used in any kind of biological context where fluorescent-protein labeled structures need to be analyzed in rod-shaped cells. AVAILABILITY: RodCellJ is freely available under http://bigwww.epfl.ch/algorithms.html, (after acceptance of the publication).
Resumo:
In many European countries, image quality for digital x-ray systems used in screening mammography is currently specified using a threshold-detail detectability method. This is a two-part study that proposes an alternative method based on calculated detectability for a model observer: the first part of the work presents a characterization of the systems. Eleven digital mammography systems were included in the study; four computed radiography (CR) systems, and a group of seven digital radiography (DR) detectors, composed of three amorphous selenium-based detectors, three caesium iodide scintillator systems and a silicon wafer-based photon counting system. The technical parameters assessed included the system response curve, detector uniformity error, pre-sampling modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Approximate quantum noise limited exposure range was examined using a separation of noise sources based upon standard deviation. Noise separation showed that electronic noise was the dominant noise at low detector air kerma for three systems; the remaining systems showed quantum noise limited behaviour between 12.5 and 380 µGy. Greater variation in detector MTF was found for the DR group compared to the CR systems; MTF at 5 mm(-1) varied from 0.08 to 0.23 for the CR detectors against a range of 0.16-0.64 for the DR units. The needle CR detector had a higher MTF, lower NNPS and higher DQE at 5 mm(-1) than the powder CR phosphors. DQE at 5 mm(-1) ranged from 0.02 to 0.20 for the CR systems, while DQE at 5 mm(-1) for the DR group ranged from 0.04 to 0.41, indicating higher DQE for the DR detectors and needle CR system than for the powder CR phosphor systems. The technical evaluation section of the study showed that the digital mammography systems were well set up and exhibiting typical performance for the detector technology employed in the respective systems.
Resumo:
PURPOSE: The aim of this study was to assess the outcome of patients with primary spinal myxopapillary ependymoma (MPE). MATERIALS AND METHODS: Data from a series of 85 (35 females, 50 males) patients with spinal MPE were collected in this retrospective multicenter study. Thirty-eight (45%) underwent surgery only and 47 (55%) received postoperative radiotherapy (RT). Median administered radiation dose was 50.4 Gy (range, 22.2-59.4). Median follow-up of the surviving patients was 60.0 months (range, 0.2-316.6). RESULTS: The 5-year progression-free survival (PFS) was 50.4% and 74.8% for surgery only and surgery with postoperative low- (<50.4 Gy) or high-dose (>or=50.4 Gy) RT, respectively. Treatment failure was observed in 24 (28%) patients. Fifteen patients presented treatment failure at the primary site only, whereas 2 and 1 patients presented with brain and distant spinal failure only. Three and 2 patients with local failure presented with concomitant spinal distant seeding and brain failure, respectively. One patient failed simultaneously in the brain and spine. Age greater than 36 years (p = 0.01), absence of neurologic symptoms at diagnosis (p = 0.01), tumor size >or=25 mm (p = 0.04), and postoperative high-dose RT (p = 0.05) were variables predictive of improved PFS on univariate analysis. In multivariate analysis, only postoperative high-dose RT was independent predictors of PFS (p = 0.04). CONCLUSIONS: The observed pattern of failure was mainly local, but one fifth of the patients presented with a concomitant spinal or brain component. Postoperative high-dose RT appears to significantly reduce the rate of tumor progression.
Resumo:
Purpose: Invasion and migration are key processes of glioblastoma and are tightly linked to tumor recurrence. Integrin inhibition using cilengitide has shown synergy with chemotherapy and radiotherapy in vitro and promising activity in recurrent glioblastoma. This multicenter, phase I/IIa study investigated the efficacy and safety of cilengitide in combination with standard chemoradiotherapy in newly diagnosed glioblastoma. Patients and Methods: Patients (age >= 18 to >= 70 years) were treated with cilengitide (500 mg) administered twice weekly intravenously in addition to standard radiotherapy with concomitant and adjuvant temozolomide. Treatment was continued until disease progression or for up to 35 weeks. The primary end point was progression-free survival (PFS) at 6 months. Results: Fifty-two patients ( median age, 57 years; 62% male) were included. Six- and 12-month PFS rates were 69% (95% CI, 54% to 80%) and 33% ( 95% CI, 21% to 46%). Median PFS was 8 months ( 95% CI, 6.0 to 10.7 months). Twelve- and 24-month overall survival ( OS) rates were 68% ( 95% CI, 53% to 79%) and 35% ( 95% CI, 22% to 48%). Median OS was 16.1 months ( 95% CI, 13.1 to 23.2 months). PFS and OS were longer in patients with tumors with O-6-methylguanine-DNA methyltransferase (MGMT) promoter methylation (13.4 and 23.2 months) versus those without MGMT promoter methylation (3.4 and 13.1 months). The combination of cilengitide with temozolomide and radiotherapy was well tolerated, with no additional toxicity. No pharmacokinetic interactions between temozolomide and cilengitide were identified. Conclusion: Compared with historical controls, the addition of concomitant and adjuvant cilengitide to standard chemoradiotherapy demonstrated promising activity in patients with glioblastoma with MGMT promoter methylation. J Clin Oncol 28:2712-2718. (C) 2010 by American Society of Clinical Oncology
Resumo:
We propose a method for brain atlas deformation inpresence of large space-occupying tumors, based on an apriori model of lesion growth that assumes radialexpansion of the lesion from its starting point. First,an affine registration brings the atlas and the patientinto global correspondence. Then, the seeding of asynthetic tumor into the brain atlas provides a templatefor the lesion. Finally, the seeded atlas is deformed,combining a method derived from optical flow principlesand a model of lesion growth (MLG). Results show that themethod can be applied to the automatic segmentation ofstructures and substructures in brains with grossdeformation, with important medical applications inneurosurgery, radiosurgery and radiotherapy.
Resumo:
Squamous cell and basocellular carcinoma of the face have an excellent prognosis. Nevertherless, a small proportion therefore of these cancers differs by a much more aggressive behavior, caracterised by a tendency to infiltrate the deep facial soft tissues and facial bones. The invasion of the craniofacial skeleton and the intracranial structures follows the embryonic fusion lines or the facial sensitive or motor nerves, sometimes years after the initial treatment. The development of craniofacial surgery, reconstruction techniques and conformational radiotherapy allows us now to offer curative guided treatments, for these advanced staged tumors with a remaining limited prognosis. A therapeutic benefit implies a rigorous selection of these patients.