923 resultados para hygiene indicators


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This FAL Bulletin analyses the development of logistics observatories and the construction of regional integration indicators in Latin America and the Caribbean. To this end, it examines experiences, in the region and worldwide, in relation to the construction of indicators and presents a set of policy recommendations for proper implementation. The Mesoamerica Project is used as a case study to construct a set of indicators for logistics infrastructures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar o perfil clínico-epidemiológico de saúde bucal em pacientes portadores de hanseníase em PQT através da avaliação clínica da mucosa bucal, dos indicadores epidemiológicos IPV (Índice de Placa Visível), ISG (ìndice de Sangramento Gengival), ICPOD (Índice de Dentes Cariados, Perdidos e Obturados) e mensuração do fluxo salivar pelo ISS (Índice de Secreção Salivar), além da capacidade tampão pelo pH salivar. A amostra foi de 80 pacientes na faixa etária de 8 a 73 anos submetidos ao exame clínico bucal e coleta estimulada de saliva, divididos em Grupo de Estudo (GE), constituído de 40 pacientes portadores de hanseníase em PQT, atendidos no CRTDS Dr. Marcello Candia Marituba-Pa; e Grupo Controle (GC), de pacientes não portadores de hanseníase. Os resultados apontaram, 62,5% de alterações inespecíficas da mucosa bucal, dentre as mais frequentes pigmentação racial na gengiva, linha alba mordiscada na mucosa jugal, inflamação gengival, varicosidade no ventre lingual e trauma por uso de prótese no GE, não havendo diferença estatística significante (p=0,14) com o GC. A média do IPV no GE foi de 50,4% das superfícies dentárias com acúmulo de placa bacteriana, não havendo também diferença estatisticamente significante (p=0,40) com o GC. O IPV foi maior nos indivíduos sem acesso ao serviço odontológico e à medida que aumentou o grau de incapacidade dos pacientes menor foi o acesso ao serviço. A média do ISG foi de 29,7% das superfícies dentárias com sangramento gengival, não havendo diferença estatística significante (p=0,35) com o GC. O ICPOD médio foi de 11,6 variando de 4,0 a 24, o que aumentou com o avanço da idade. O maior acúmulo de placa, o sangramento gengival e o consumo de alimentos carigênicos fora do horário da refeição também contribuiram para o aumento do ICPOD. Outro fator relacionado ao aumento de ICPOD foi o não acesso ao serviço odontológico por 70% dos pacientes hansenianos, havendo diferença estatisticamente significante (p=0,0005) com o GC e a falta de orientação de higiene bucal em 60%, havendo diferença estatisticamente significante (p=0,01) com o GC. O ISS médio foi de 0,9ml/min e não apresentou associação com as doses do PQT e nem com o uso de prednisona. Dos pacientes do GE, 25% apresentaram hipossalivação, mas não houve aumento de ICPOD e nenhum dos grupos revelou alteração de pH salivar, variando de 5,85 a 7,34, com capacidade tampão dentro do padrão de normalidade. Concui-se que perfil clínico-epidemiológico dos pacientes portadores de hanseníase assemelha-se a do grupo controle, não tendo sido diagnosticado nenhuma alteração da mucosa bucal específica para hanseníase, o que não anula, entretanto a póssibilidade da cavidade bucal ser fonte de infecção para hanseníase necessitando de confirmação histopatológica e/ou PCR para detecção de M. leprae viável. Além disso, os dados mostraram que a maioria dos pacientes hansenianos avaliados não tem acesso ao serviço odontológico, nem orientação de higiene bucal, resultante da falta de políticas públicas de saúde bucal para hansenianos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O regime de macromaré e a pororoca controlam a dinâmica estuarina do Araguari, na qual é muito diferente dos modelos tradicionais dos estuários sob este regime de maré. Objetivando estabelecer zonas estuarinas no Araguari com base em assembléias de foraminíferos, tecamebas, palinomorfos e parâmetros físico-químicos, foram estabelecidas dezesseis estações amostrais ao longo do estuário. A turbidez e a temperatura foram os parâmetros ambientais que permitiram determinar gradiente estuarino. Dezoito espécies de foraminíferos, dez espécies de tecamebas e quatorze espécies de palinomorfos foram identificadas. A análise de agrupamento em modo-R mostrou a existência de assembléias de foraminíferos e quatro de palinomorfos. A análise em CCA demonstrou que a turbidez e a matéria orgânica como os parâmetros de maior influência na distribuição dos foraminíferos tecamebas no Araguari. A análise de agrupamento em Modo-Q usando todos os dados formou quarto grupos de estações que sugerem a existência de três zonas estuarinas: Zona I - composta por tecamebas e palinomorfos continentais; Zona II - compostas por foraminíferos de manguezal, acritacos e todas as assembléias de palinomorfos; e Zona III - composta por foraminíferos de manguezal e estuarinos e por todas as assembléias de palinomorfos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Malnutrition is prevalent in patients with advanced liver disease (LD) related to multifactorial causes. Fluid retention can underestimate the nutritional status based on anthropometric measures. We evaluated nutritional indicators and body composition (BC) in patients with liver cirrhosis and correlated them with LD severity. METHODS: Forty three patients with LD enrolled for liver transplantation were evaluated by Anthropometric measures, subjective evaluation (Global Assessment of Nutritional Status - SGA) and biochemical indicators. Single-frequency electrical bioimpedance (SFE-BIA) was used to evaluate body composition (BC). It measured resistance (R), reactance (Xc) and the phase angle (PA). LD severity was estimated by Child-Pugh and Meld criteria (Model for End-Stage Liver Disease). RESULTS: Child-Pugh index between patients was 7.11±1.70 and Meld was 12.23±4.22. Arm Circumference, Arm Muscle Circumference and Arm Muscle Area, SGA, hemoglobin, hematocrit and albumin showed better correlation with disease severity. Xc and PA showed correlation both with Meld and Child-Pugh score when BC were evaluated. PA was depleted in 55.8% of the patients. CONCLUSIONS: Diagnosis of malnutrition varied according to the method. Global assessment of nutritional status showed better correlation with disease severity than with objective methods. Single-frequency electrical bioimpedance for body composition analysis in cirrhotic patients must be cautiously used; however, primary vectors seems to be valid and promising in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo do estudo foi descrever e analisar os indicadores de qualidade de Centros de Material e Esterilização de hospitais públicos acreditados do Estado de São Paulo e sua gestão pelos responsáveis do setor. Trata-se de um estudo de casos múltiplos, onde são apresentados os dados interligados de três hospitais acreditados num relatório de casos cruzados. Os dados foram coletados por entrevista semiestruturada com o responsável e por visita técnica com análise documental. Os resultados constatam a dificuldade dos responsáveis em pontuar os indicadores específicos do setor e os referidos foram os de produção e pesquisa de satisfação do cliente que não retratam a qualidade efetiva do serviço, pois são fragmentados, sem consolidação de resultados na busca de melhorias, o que sugere baixa especificidade e baixa sensibilidade dos critérios da Organização Nacional de Acreditação à realidade deste setor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiovascular diseases are a growing public health problem that affects most people over the age of 65 years and abdominal obesity is one of the risk factors for the development of these diseases. There are several methods that can be used to measure body fat, but their accuracy needs to be evaluated, especially in specific populations such as the elderly. The aim of this study was to assess the accuracy of anthropometric indicators to estimate the percentage of abdominal fat in subjects aged 80 years or older. A total of 125 subjects ranging in age from 80 to 95 years (83.5 ± 3), including 79 women (82.4 ± 3 years) and 46 men (83.6 ± 3 years), were studied. The following anthropometric indicators were used: body mass index (BMI), waist circumference (WC), waist-hip ratio (WHR), and waist-to-height ratio (WHtR). The percentage of abdominal fat was measured by DEXA. Sensitivity and specificity were analyzed using an ROC curve. The sensitivity, specificity and AUC were 0. 578, 0. 934 and 0. 756 for BMI, respectively; 0.703, 0.820 and 0.761 for WC; 0.938, 0.213 and 0.575 for WHR, and 0.984, 0.344 and 0.664 for WHtR. BMI and WC were the anthropometric indicators with the largest area under the curve and were therefore more adequate to identify the presence or absence of abdominal obesity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The main function of the mucociliary system is the removal of particles or substances that are potentially harmful to the respiratory tract. The tuning fork therapeutic for the purpose of bronchial hygiene has still not been described in the literature. The optimal vibration frequency to mobilize secretions is widely debated and varies between 3 and 25 Hz. It is expected that a tuning fork is able to generate vibrations in the thorax, facilitating bronchial hygiene. The aim of the present study is to develop tuning forks with different frequencies, for use in bronchopulmonary hygiene therapy. Methods: The first tuning fork was made with a fixed frequency of 25 Hz and it was recorded in the Brazilian institution of patent registration. This device generated a frequency of 25 Hz and had a weight of 521 g, with dimensions of 600 mm in total length. The device is characterized by a bottom end containing a transducer with a diameter of 62 mm and a thickness of 5/16 mm (8''), a rod removable 148 mm, fork length of 362 mm and an extension at the upper end of sinuous shape bilaterally.The tuning forks must be applied at an angle of 90° directly on the chest wall of the patient after pulmonary auscultation for location of secretions. The tuning fork is activated by squeezing the tips of the extensions together and releasing them in a sudden movement. Results: This study shows the result of the development of others three tuning forks of different dimensions to generate different frequencies. Each equipment reaches a fixed frequency preset of 12, 15 and 20 Hz measured by digital oscilloscope. Conclusions: The tuning fork models developed in this study generated different frequencies proposed by the scientific literature as effective in the mobilization of pulmonary secretions.