933 resultados para heat and mass transfer
Resumo:
In ultracold atoms settings, inelastic light scattering is a preeminent technique to reveal static and dynamic properties at nonzero momentum. In this work, we investigate an array of one-dimensional trapped Bose gases, by measuring both the energy and the momentum imparted to the system via light scattering experiments. The measurements are performed in the weak perturbation regime, where these two quantities-the energy and momentum transferred-are expected to be related to the dynamic structure factor of the system. We discuss this relation, with special attention to the role of in-trap dynamics on the transferred momentum.
Resumo:
Seeded zone-melt recrystallization using a dual electron beam system has been performed on silicon-on-insulator material, which was prepared with single-crystal silicon filling of the seed windows by selective epitaxial growth. The crystal quality has been assessed by a variety of microscopic techniques, and it is shown that single-crystal films 0.5-1.0 μm thick over 1.0 μm of isolating oxide may be prepared by this method. These films have considerably less lateral variation in thickness than standard material, in which the windows are not so filled. The filling method is suitable for both single- and multiple-layer silicon-on-insulator, and gives the advantages of excellent layer uniformity after recrystallization and improved planarity of the whole chip structure. Experiments using various amounts of seed window filling have shown that the lateral variations of silicon film thickness seen in unplanarized material are due to stress relief in the cap oxide when the silicon film is molten, rather than the effect previously postulated in which they were assumed to be due to the contraction of silicon on melting.
Resumo:
This paper deals with the existing fishing crafts, new vessel types, boat building programmes, their standardisation and mass-production in India.
Resumo:
A ball-on-flat reciprocating micro-tribometer has been used to measure the friction coefficient between aluminium alloy strip and a steel ball. A relatively small ball and correspondingly low contact load is used to give a contact width of the order of 100μm, closer to asperity contact widths than generally found for this type of test. The effects of load, initial strip surface roughness, lubricants and boundary additives are investigated. It is found that the friction coefficient is significantly reduced by the addition of a lubricant. Observations of the wear tracks and ball surface show that the material transfer from aluminium to the ball is reduced in the presence of the lubricant. The initial friction coefficient is further reduced by the addition of a boundary additive, but the friction coefficient after 8 cycles is unchanged. Copyright © 2004 by Springer Science+Business Media, Inc.
Resumo:
An experiment was conducted to optimize the procedure of gynogenesis in African catfish, Clarias gariepinus by suppressing meiotic and mitotic cell divisions in fertilized eggs. Gynogensis was conducted by fertilizing normal eggs with UV-irradiated sperm followed by either heat or cold shocking Irradiation of spermatozoa was given for a duration of 1 min and the eggs were fertilized in vitro. Cold shock at a temperature of 3± 1°C for a duration of 30 and 60 min and heat shock at a temperature of 39± 1°C for a duration of 1 and 2 min was applied to induce diploidy. Higher percentage of hatching (68.66) was observed for meiotic gynogens at a shock temperature of 39± 1°C for a duration of 1 min, 5 min after fertilization (af). Higher percentage of mitotic gynogenetic induction (15.33) was observed at a temperature shock of 39± 1°C for a duration of 1 min, 30 min af.
Resumo:
In five groups of seasonally provisioned Tibetan macaques (Macaca thibetana) at Mt. Emei, males were sampled for wounds as an indicator of their competition for females during about 80 days in the 1987 mating season. Quantitative data on intergroup transfer were collected in a period between June 1986 and December 1987. The young adult (YA) males, the most active age-class in mating activity and intergroup transfer, received most of the wounds. Wounds tended to appear more in the front of body for YA and subadults (SA) than they did for middle-old aged (MO) males. This implies that some of the MO males were more active and aggressive in the fights. During the 1.5 year period, 5/6 of the YA and 5/17 of the MO males made intergroup shifts. Although YA males faced a high risk of receiving wounds at transfer, they usually rose in rank. On the other hand, the MO males transferred more smoothly but dropped in rank. The peripheral SA males, which rarely emigrated in the population, were an active component in determining the wounding rate, and the rate and direction of male migration. Three SA immigrants died of severe attacks made by resident males in 1988 and 1991. Adult sex ratios and their variations were considerably reduced with male nonrandom shifts and better conservation of the population.
Resumo:
There is growing evidence that focal thinning of cortical bone in the proximal femur may predispose a hip to fracture. Detecting such defects in clinical CT is challenging, since cortices may be significantly thinner than the imaging system's point spread function. We recently proposed a model-fitting technique to measure sub-millimetre cortices, an ill-posed problem which was regularized by assuming a specific, fixed value for the cortical density. In this paper, we develop the work further by proposing and evaluating a more rigorous method for estimating the constant cortical density, and extend the paradigm to encompass the mapping of cortical mass (mineral mg/cm(2)) in addition to thickness. Density, thickness and mass estimates are evaluated on sixteen cadaveric femurs, with high resolution measurements from a micro-CT scanner providing the gold standard. The results demonstrate robust, accurate measurement of peak cortical density and cortical mass. Cortical thickness errors are confined to regions of thin cortex and are bounded by the extent to which the local density deviates from the peak, averaging 20% for 0.5mm cortex.
Resumo:
There is growing evidence that focal thinning of cortical bone in the proximal femur may predispose a hip to fracture. Detecting such defects in clinical CT is challenging, since cortices may be significantly thinner than the imaging system's point spread function. We recently proposed a model-fitting technique to measure sub-millimetre cortices, an ill-posed problem which was regularized by assuming a specific, fixed value for the cortical density. In this paper, we develop the work further by proposing and evaluating a more rigorous method for estimating the constant cortical density, and extend the paradigm to encompass the mapping of cortical mass (mineral mg/cm 2) in addition to thickness. Density, thickness and mass estimates are evaluated on sixteen cadaveric femurs, with high resolution measurements from a micro-CT scanner providing the gold standard. The results demonstrate robust, accurate measurement of peak cortical density and cortical mass. Cortical thickness errors are confined to regions of thin cortex and are bounded by the extent to which the local density deviates from the peak, averaging 20% for 0.5mm cortex. © 2012 Elsevier B.V.
Resumo:
Thin film bulk acoustic wave resonator (FBAR) devices supporting simultaneously multiple resonance modes have been designed for gravimetric sensing. The mechanism for dual-mode generation within a single device has been discussed, and theoretical calculations based on finite element analysis allowed the fabrication of FBARs whose resonance modes have opposite reactions to temperature changes; one of the modes exhibiting a positive frequency shift for a rise of temperature whilst the other mode exhibits a negative shift. Both modes exhibit negative frequency shift for a mass load and hence by monitoring simultaneously both modes it is possible to distinguish whether a change in the resonance frequency is due to a mass load or temperature variation (or a combination of both), avoiding false positive/negative responses in gravimetric sensing without the need of additional reference devices or complex electronics.