981 resultados para heart right atrium


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tricyclic antidepressants have notable cardiac side effects, and this issue has become important due to the recent reports of increased cardiovascular mortality in patients with depression and anxiety. Several previous studies indicate that serotonin reuptake inhibitors (SRIs) do not appear to have such adverse effects. Apart from the effects of these drugs on routine 12-lead ECG, the effects on beat-to-beat heart rate (HR) and QT interval time series provide more information on the side effects related to cardiac autonomic function. In this study, we evaluated the effects of two antidepressants, nortriptyline (n = 13), a tricyclic, and paroxetine (n = 16), an SRI inhibitor, on HR variability in patients with panic disorder, using a measure of chaos, the largest Lyapunov exponent (LLE) using pre- and posttreatment HR time series. Our results show that nortriptyline is associated with a decrease in LLE of high frequency (HF: 0.15-0.5 Hz) filtered series, which is most likely due to its anticholinergic effect, while paroxetine had no such effect. Paroxetine significantly decreased sympathovagal ratios as measured by a decrease in LLE of LF/HF. These results suggest that paroxetine appears to be safer in regards to cardiovascular effects compared to nortriptyline in this group of patients. (C) 2003 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study a system of ordinary differential equations linked by parameters and subject to boundary conditions depending on parameters. We assume certain definiteness conditions on the coefficient functions and on the boundary conditions that yield, in the corresponding abstract setting, a right-definite case. We give results on location of the eigenvalues and oscillation of the eigenfunctions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intra-aortic balloon pumping is a counter pulsation technique for temporary circulatory assistance in cardiogenic shock and other low cardiac output conditions. Conventional systems use a balloon at the end of a catheter driven by a solenoid valve, controlled by patient's ECG or ventricular pressure signal. This results in time delay introducted by solenoid spool inertia, gas inertia, and hysteresis effects of the solenoid. Fluidics, because of their non-moving part operation and high switching speeds, minimizes the inertial effects while contributing high reliability. This communication describes a fluidic system developed for driving the balloon accepting electric control signals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the existing issues in implant failure of orthopedic biomaterials is the toxicity induced by the fine particles released during long term use in vivo, leading to acute inflammatory response. In developing a new class of piezobiocomposite to mimic the integrated electrical and mechanical properties of bone, bone-mimicking physical properties as well as in vitro cytocompatibility properties have been achieved with spark plasma sintered hydroxyapatite (HA)-barium titanate (BaTiO3) composites. However, the presence of BaTiO3 remains a concern towards the potential toxicity effect. To address this issue, present work reports the first result to conclusively confirm the non-toxic effect of HA-BaTiO3 piezobiocomposite nanoparticulates, in vivo. Twenty BALB/c mice were intraarticularly injected at their right knee joints with different concentrations of HA-BaTiO3 composite of up to 25 mg/ml. The histopathological examination confirmed the absence of any trace of injected particles or any sign of inflammatory reaction in the vital organs, such as heart, spleen, kidney and liver at 7 days post-exposure period. Rather, the injected nanoparticulates were found to be agglomerated in the vicinity of the knee joint, surrounded by macrophages. Importantly, the absence of any systemic toxicity response in any of the vital organs in the treated mouse model, other than a mild local response at the site of delivery, was recorded. The serum biochemical analyses using proinflammatory cytokines (TNF-alpha and IL-1 beta) also complimented to the non-immunogenic response to injected particulates. Altogether, the absence of any inflammatory/ adverse reaction will open up myriad of opportunities for BaTiO3 based piezoelectric implantable devices in biomedical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a multiple initialization based spectral peak tracking (MISPT) technique for heart rate monitoring from photoplethysmography (PPG) signal. MISPT is applied on the PPG signal after removing the motion artifact using an adaptive noise cancellation filter. MISPT yields several estimates of the heart rate trajectory from the spectrogram of the denoised PPG signal which are finally combined using a novel measure called trajectory strength. Multiple initializations help in correcting erroneous heart rate trajectories unlike the typical SPT which uses only single initialization. Experiments on the PPG data from 12 subjects recorded during intensive physical exercise show that the MISPT based heart rate monitoring indeed yields a better heart rate estimate compared to the SPT with single initialization. On the 12 datasets MISPT results in an average absolute error of 1.11 BPM which is lower than 1.28 BPM obtained by the state-of-the-art online heart rate monitoring algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we show that in order for third-degree price discrimination to increase total output, the demands of the strong markets should be, as conjectured by Robinson (1933), more concave than the demands of the weak markets. By making the distinction between adjusted concavity of the inverse demand and adjusted concavity of the direct demand, we are able to state necessary conditions and sufficient conditions for third-degree price discrimination to increase total output.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Santamaría, José Miguel; Pajares, Eterio; Olsen, Vickie; Merino, Raquel; Eguíluz, Federico (eds.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A guide to option appraisal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper discusses simple methods of estimating fish yield from small reservoirs and establishes 2 indices of fish yield based on: 1) the relationship between the catch per boat in artisanal commercial fish landings and the catch per unit effort in experimental gill-net survey; and also, 2) the relationship between standing crop of fish in reservoirs and catch per unit effort in experimental gill-net survey. The paper then elaborates on the methods of utilizing these simple relationships in managing small reservoirs in Nigeria based on the principle of exclusive fishing right licence with the objective of attracting investors into this viable inland fishery investment project hitherto untapped

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biological machines are active devices that are comprised of cells and other biological components. These functional devices are best suited for physiological environments that support cellular function and survival. Biological machines have the potential to revolutionize the engineering of biomedical devices intended for implantation, where the human body can provide the required physiological environment. For engineering such cell-based machines, bio-inspired design can serve as a guiding platform as it provides functionally proven designs that are attainable by living cells. In the present work, a systematic approach was used to tissue engineer one such machine by exclusively using biological building blocks and by employing a bio-inspired design. Valveless impedance pumps were constructed based on the working principles of the embryonic vertebrate heart and by using cells and tissue derived from rats. The function of these tissue-engineered muscular pumps was characterized by exploring their spatiotemporal and flow behavior in order to better understand the capabilities and limitations of cells when used as the engines of biological machines.