974 resultados para healthy subjects


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Twitch mouth pressure (Pmo,tw) during magnetic phrenic nerve stimulation and sniff nasal inspiratory pressure (SNIP) were recently proposed as alternative noninvasive methods for assessing inspiratory muscle strength. This study aimed to compare their reproducibility with maximal inspiratory pressure (MIP) in normal subjects. Ten healthy subjects were studied at functional residual capacity in semirecumbent position. Cervical magnetic phrenic nerve stimulation was performed during gentle expiration against an occlusion incorporating a small leak. Constancy of stimulation was controlled by recording diaphragmatic electromyogram. Within and between-session reproducibility of pressure were studied for Pmo,tw, SNIP, and MIP. The subjects were studied during a session of 10 manoeuvres repeated after 1 day and 1 month. The mean values were 16 cmH2O for Pmo,tw, 118 cmH2O for SNIP, and 115 cmH2O for MIP. For the three tests, the within subject variation was small in relation to between-subject variation, with the intraclass correlation coefficient ranging 0.79-0.90 for Pmo,tw, 0.85-0.92 for SNIP, and 0.88-0.92 for MIP. At 1 day interval, the coefficient of repeatability (2 SD of differences) was 3.6 cmH2O for Pmo,tw, 32 cmH2O for SNIP and 28 cmH2O for MIP. At 1 month interval, the coefficient of repeatability was 5.8 cmH2O for Pmo,tw, 23 cmH2O for SNIP and 21 cmH2O for MIP. We conclude that the within session reproducibility of the new tests twitch mouth pressure and sniff nasal inspiratory pressure is sufficient to be clinically useful. For sniff nasal inspiratory pressure, the between session reproducibility established after 1 day was maintained after 1 month. For twitch mouth pressure, the between session reproducibility declined slightly after 1 month. These characteristics should be considered when using these methods to follow an individual patient over time.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Direct noninvasive visualization of the coronary vessel wall may enhance risk stratification by quantifying subclinical coronary atherosclerotic plaque burden. We sought to evaluate high-resolution black-blood 3D cardiovascular magnetic resonance (CMR) imaging for in vivo visualization of the proximal coronary artery vessel wall. METHODS AND RESULTS: Twelve adult subjects, including 6 clinically healthy subjects and 6 patients with nonsignificant coronary artery disease (10% to 50% x-ray angiographic diameter reduction) were studied with the use of a commercial 1.5 Tesla CMR scanner. Free-breathing 3D coronary vessel wall imaging was performed along the major axis of the right coronary artery with isotropic spatial resolution (1.0x1.0x1.0 mm(3)) with the use of a black-blood spiral image acquisition. The proximal vessel wall thickness and luminal diameter were objectively determined with an automated edge detection tool. The 3D CMR vessel wall scans allowed for visualization of the contiguous proximal right coronary artery in all subjects. Both mean vessel wall thickness (1.7+/-0.3 versus 1.0+/-0.2 mm) and wall area (25.4+/-6.9 versus 11.5+/-5.2 mm(2)) were significantly increased in the patients compared with the healthy subjects (both P<0.01). The lumen diameter (3.6+/-0.7 versus 3.4+/-0.5 mm, P=0.47) and lumen area (8.9+/-3.4 versus 7.9+/-3.5 mm(2), P=0.47) were similar in both groups. CONCLUSIONS: Free-breathing 3D black-blood coronary CMR with isotropic resolution identified an increased coronary vessel wall thickness with preservation of lumen size in patients with nonsignificant coronary artery disease, consistent with a "Glagov-type" outward arterial remodeling. This novel approach has the potential to quantify subclinical disease.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The nutritional status of cystic fibrosis (CF) patients has to be regularly evaluated and alimentary support instituted when indicated. Bio-electrical impedance analysis (BIA) is a recent method for determining body composition. The present study evaluates its use in CF patients without any clinical sign of malnutrition. Thirty-nine patients with CF and 39 healthy subjects aged 6-24 years were studied. Body density and mid-arm muscle circumference were determined by anthropometry and skinfold measurements. Fat-free mass was calculated taking into account the body density. Muscle mass was obtained from the urinary creatinine excretion rate. The resistance index was calculated by dividing the square of the subject's height by the body impedance. We show that fat-free mass, mid-arm muscle circumference and muscle mass are each linearly correlated to the resistance index and that the regression equations are similar for both CF patients and healthy subjects.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Preclinical studies implicate a role for α₁-noradrenergic receptors in the effects of psychostimulants, including 3,4-methylenedioxymethamphetamine (MDMA, "ecstasy"). The present study evaluated the effects of the α₁-noradrenergic receptor antagonist doxazosin on the acute pharmacodynamic and pharmacokinetic response to MDMA in 16 healthy subjects. Doxazosin (8 mg/d) or placebo was administered for 3 days before MDMA (125 mg) or placebo using a randomized, double-blind, placebo-controlled, 4-session, crossover design. Doxazosin reduced MDMA-induced elevations in blood pressure, body temperature, and moderately attenuated positive mood but enhanced tachycardia associated with MDMA. The results indicate that α₁-adrenergic receptors contribute to the acute cardiostimulant and to a minor extent possibly also to the thermogenic and euphoric effects of MDMA in humans.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Because of the development of modern transportation facilities, an ever rising number of individuals including many patients with preexisting diseases visit high-altitude locations (>2500 m). High-altitude exposure triggers a series of physiologic responses intended to maintain an adequate tissue oxygenation. Even in normal subjects, there is enormous interindividual variability in these responses that may be further amplified by environmental factors such as cold temperature, low humidity, exercise, and stress. These adaptive mechanisms, although generally tolerated by most healthy subjects, may induce major problems in patients with preexisting cardiovascular diseases in which the functional reserves are already limited. Preexposure assessment of patients helps to minimize risk and detect contraindications to high-altitude exposure. Moreover, the great variability and nonpredictability of the adaptive response should encourage physicians counseling such patients to adapt a cautionary approach. Here, we will briefly review how high-altitude adjustments may interfere with and aggravate/decompensate preexisting cardiovascular diseases. Moreover, we will provide practical recommendations on how to investigate and counsel patients with cardiovascular disease desiring to travel to high-altitude locations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Basal ganglia and brain stem nuclei are involved in the pathophysiology of various neurological and neuropsychiatric disorders. Currently available structural T1-weighted (T1w) magnetic resonance images do not provide sufficient contrast for reliable automated segmentation of various subcortical grey matter structures. We use a novel, semi-quantitative magnetization transfer (MT) imaging protocol that overcomes limitations in T1w images, which are mainly due to their sensitivity to the high iron content in subcortical grey matter. We demonstrate improved automated segmentation of putamen, pallidum, pulvinar and substantia nigra using MT images. A comparison with segmentation of high-quality T1w images was performed in 49 healthy subjects. Our results show that MT maps are highly suitable for automated segmentation, and so for multi-subject morphometric studies with a focus on subcortical structures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC's ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Detailed knowledge of the anatomy and connectivity pattern of cortico-basal ganglia circuits is essential to an understanding of abnormal cortical function and pathophysiology associated with a wide range of neurological and neuropsychiatric diseases. We aim to study the spatial extent and topography of human basal ganglia connectivity in vivo. Additionally, we explore at an anatomical level the hypothesis of coexistent segregated and integrative cortico-basal ganglia loops. We use probabilistic tractography on magnetic resonance diffusion weighted imaging data to segment basal ganglia and thalamus in 30 healthy subjects based on their cortical and subcortical projections. We introduce a novel method to define voxel-based connectivity profiles that allow representation of projections from a source to more than one target region. Using this method, we localize specific relay nuclei within predefined functional circuits. We find strong correlation between tractography-based basal ganglia parcellation and anatomical data from previously reported invasive tracing studies in nonhuman primates. Additionally, we show in vivo the anatomical basis of segregated loops and the extent of their overlap in prefrontal, premotor, and motor networks. Our findings in healthy humans support the notion that probabilistic diffusion tractography can be used to parcellate subcortical gray matter structures on the basis of their connectivity patterns. The coexistence of clearly segregated and also overlapping connections from cortical sites to basal ganglia subregions is a neuroanatomical correlate of both parallel and integrative networks within them. We believe that this method can be used to examine pathophysiological concepts in a number of basal ganglia-related disorders.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In recent years, several vasopressin antagonists have been developed that block V-1 receptors either selectively or nonselectively.(1,2) To date, one combined V-1/V-2 antagonist (primarily a V-2 antagonist, as determined on the basis of human receptor binding data), conivaptan, has been approved for the treatment of euvolemic hyponatremia.(3,4) We have previously shown that the vascular properties of a vasopressin V-1 antagonist can be investigated safely and reliably in healthy subjects. We used the measurement of skin blood flow after intradermic injection of exogenous arginine vasopressin on a skin area prevasodilated with calcitonin gene-related peptide (CGRP).(3,5) This technique enables the documentation of the dose-dependent effects of vasopressin or vasopressin antagonists. In this study, we have characterized the V-1a pharmacodynamic profile of increasing doses of RWJ-676070, a new orally active dual V-1a/V-2 receptor antagonist, in healthy subjects.(5)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To compare 3 different flow targeted magnetization preparation strategies for coronary MR angiography (cMRA), which allow selective visualization of the vessel lumen. MATERIAL AND METHODS: The right coronary artery of 10 healthy subjects was investigated on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Healthcare, Best, NL). A navigator-gated and ECG-triggered 3D radial steady-state free-precession (SSFP) cMRA sequence with 3 different magnetization preparation schemes was performed referred to as projection SSFP (selective labeling of the aorta, subtraction of 2 data sets), LoReIn SSFP (double-inversion preparation, selective labeling of the aorta, 1 data set), and inflow SSFP (inversion preparation, selective labeling of the coronary artery, 1 data set). Signal-to-noise ratio (SNR) of the coronary artery and aorta, contrast-to-noise ratio (CNR) between the coronary artery and epicardial fat, vessel length and vessel sharpness were analyzed. RESULTS: All cMRA sequences were successfully obtained in all subjects. Both projection SSFP and LoReIn SSFP allowed for selective visualization of the coronary arteries with excellent background suppression. Scan time was doubled in projection SSFP because of the need for subtraction of 2 data sets. In inflow SSFP, background suppression was limited to the tissue included in the inversion volume. Projection SSFP (SNR(coro): 25.6 +/- 12.1; SNR(ao): 26.1 +/- 16.8; CNR(coro-fat): 22.0 +/- 11.7) and inflow SSFP (SNR(coro): 27.9 +/- 5.4; SNR(ao): 37.4 +/- 9.2; CNR(coro-fat): 24.9 +/- 4.8) yielded significantly increased SNR and CNR compared with LoReIn SSFP (SNR(coro): 12.3 +/- 5.4; SNR(ao): 11.8 +/- 5.8; CNR(coro-fat): 9.8 +/- 5.5; P &lt; 0.05 for both). Longest visible vessel length was found with projection SSFP (79.5 mm +/- 18.9; P &lt; 0.05 vs. LoReIn) whereas vessel sharpness was best in inflow SSFP (68.2% +/- 4.5%; P &lt; 0.05 vs. LoReIn). Consistently good image quality was achieved using inflow SSFP likely because of the simple planning procedure and short scanning time. CONCLUSION: Three flow targeted cMRA approaches are presented, which provide selective visualization of the coronary vessel lumen and in addition blood flow information without the need of contrast agent administration. Inflow SSFP yielded highest SNR, CNR and vessel sharpness and may prove useful as a fast and efficient approach for assessing proximal and mid vessel coronary blood flow, whereas requiring less planning skills than projection SSFP or LoReIn SSFP.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present MBIS (Multivariate Bayesian Image Segmentation tool), a clustering tool based on the mixture of multivariate normal distributions model. MBIS supports multichannel bias field correction based on a B-spline model. A second methodological novelty is the inclusion of graph-cuts optimization for the stationary anisotropic hidden Markov random field model. Along with MBIS, we release an evaluation framework that contains three different experiments on multi-site data. We first validate the accuracy of segmentation and the estimated bias field for each channel. MBIS outperforms a widely used segmentation tool in a cross-comparison evaluation. The second experiment demonstrates the robustness of results on atlas-free segmentation of two image sets from scan-rescan protocols on 21 healthy subjects. Multivariate segmentation is more replicable than the monospectral counterpart on T1-weighted images. Finally, we provide a third experiment to illustrate how MBIS can be used in a large-scale study of tissue volume change with increasing age in 584 healthy subjects. This last result is meaningful as multivariate segmentation performs robustly without the need for prior knowledge.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The vascular endothelium has been shown to play a pivotal role in the pathophysiology of sepsis through the expression of surface proteins and secretion of soluble mediators. Endocan (endothelial cell-specific molecule-1), a 50-kDa dermatan sulfate proteoglycan, is expressed by endothelial cells in lung and kidney and can be detected at low levels in the serum of healthy subjects. Increased concentrations were described in patients with sepsis, severe sepsis and septic shock compared to healthy individuals, with serum concentrations related to the severity of illness. In the present study, we investigated endocan, procalcitonin and C-reactive protein in postmortem serum from femoral blood in a series of sepsis-related fatalities and control individuals who underwent medicolegal investigations. Endocan was also measured in pericardial fluid. Two study groups were prospectively formed, a sepsis-related fatalities group and a control group. The sepsis-related fatalities group consisted of sixteen forensic autopsy cases with documented clinical diagnosis of sepsis in vivo. The control group consisted of sixteen forensic autopsy cases with various noninfectious causes of death. Postmortem serum endocan concentrations were significantly higher in the sepsis group, with values ranging from 0.519ng/ml to 6.756ng/ml. In the control group, endocan levels were undetectable in eleven out of sixteen cases. The results of the data analysis revealed similar endocan concentrations in the pericardial fluid of both studied groups. Endocan can be considered a suitable biological parameter for the detection of sepsis-related deaths in forensic pathology routine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Usually the measurement of multi-segment foot and ankle complex kinematics is done with stationary motion capture devices which are limited to use in a gait laboratory. This study aimed to propose and validate a wearable system to measure the foot and ankle complex joint angles during gait in daily conditions, and then to investigate its suitability for clinical evaluations. The foot and ankle complex consisted of four segments (shank, hindfoot, forefoot, and toes), with an inertial measurement unit (3D gyroscopes and 3D accelerometers) attached to each segment. The angles between the four segments were calculated in the sagittal, coronal, and transverse planes using a new algorithm combining strap-down integration and detection of low-acceleration instants. To validate the joint angles measured by the wearable system, three subjects walked on a treadmill for five minutes at three different speeds. A camera-based stationary system that used a cluster of markers on each segment was used as a reference. To test the suitability of the system for clinical evaluation, the joint angle ranges were compared between a group of 10 healthy subjects and a group of 12 patients with ankle osteoarthritis, during two 50-m walking trials where the wearable system was attached to each subject. On average, over all joints and walking speeds, the RMS differences and correlation coefficients between the angular curves obtained using the wearable system and the stationary system were 1 deg and 0.93, respectively. Moreover, this system was able to detect significant alteration of foot and ankle function between the group of patients with ankle osteoarthritis and the group of healthy subjects. In conclusion, this wearable system was accurate and suitable for clinical evaluation when used to measure the multi-segment foot and ankle complex kinematics during long-distance walks in daily life conditions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We assessed decision-making capacity and emotional reactivity in 20 patients with multiple sclerosis (MS) and in 16 healthy subjects using the Gambling Task (GT), a model of real-life decision making, and the skin conductance response (SCR). Demographic, neurological, affective, and cognitive parameters were analyzed in MS patients for their effect on decision-making performance. MS patients persisted longer (slope, -3.6%) than the comparison group (slope, -6.4%) in making disadvantageous choices as the GT progressed (p < 0.001), suggesting significant slower learning in MS. Patients with higher Expanded Disability Status Scale scores (EDSS >2.0) showed a different pattern of impairment in the learning process compared with patients with lower functional impairment (EDSS </=2.0). This slower learning was associated with impaired emotional reactivity (anticipatory SCR 3.9 vs 6.1 microSiemens [microS] for patients vs the comparison group, p < 0.0001; post-choice SCR 3.9 vs 6.2 microS, p < 0.0001), but not with executive dysfunction. Impaired emotional dimensions of behavior (assessed using the Dysexecutive Questionnaire, p < 0.002) also correlated with slower learning. Given the considerable consequences that impaired decision making can have on daily life, we suggest that this factor may contribute to handicap and altered quality of life secondary to MS and is dependent on emotional experience. Ann Neurol 2004.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Diffusion-weighting in magnetic resonance imaging (MRI) increases the sensitivity to molecular Brownian motion, providing insight in the micro-environment of the underlying tissue types and structures. At the same time, the diffusion weighting renders the scans sensitive to other motion, including bulk patient motion. Typically, several image volumes are needed to extract diffusion information, inducing also inter-volume motion susceptibility. Bulk motion is more likely during long acquisitions, as they appear in diffusion tensor, diffusion spectrum and q-ball imaging. Image registration methods are successfully used to correct for bulk motion in other MRI time series, but their performance in diffusion-weighted MRI is limited since diffusion weighting introduces strong signal and contrast changes between serial image volumes. In this work, we combine the capability of free induction decay (FID) navigators, providing information on object motion, with image registration methodology to prospectively--or optionally retrospectively--correct for motion in diffusion imaging of the human brain. Eight healthy subjects were instructed to perform small-scale voluntary head motion during clinical diffusion tensor imaging acquisitions. The implemented motion detection based on FID navigator signals is processed in real-time and provided an excellent detection performance of voluntary motion patterns even at a sub-millimetre scale (sensitivity≥92%, specificity>98%). Motion detection triggered an additional image volume acquisition with b=0 s/mm2 which was subsequently co-registered to a reference volume. In the prospective correction scenario, the calculated motion-parameters were applied to perform a real-time update of the gradient coordinate system to correct for the head movement. Quantitative analysis revealed that the motion correction implementation is capable to correct head motion in diffusion-weighted MRI to a level comparable to scans without voluntary head motion. The results indicate the potential of this method to improve image quality in diffusion-weighted MRI, a concept that can also be applied when highest diffusion weightings are performed.