916 resultados para external fixation
Resumo:
The fixation and the bone ingrowth at the interface of porous cylindrical implants (total porosity of 37% and average pores diameter of 480 mu m) were compared in vivo to rough cylindrical implants (R-a = 5.3 mu m), both of commercially pure titanium, made by powder metallurgy. The implants were inserted into the tibias of 20 rabbits and the animals were sacrificed 4 and 8 weeks after surgery. The percentage of bone-implant contact observed in porous implant was significantly larger than in the rough ones for all of sacrifice periods, respectively, 57% vs. 46% after 4 weeks, and 59% vs. 50% after 8 weeks. The mechanical tests showed a significant increase in the shear strength of the porous implants for the two analyzed periods, 4 and 8 weeks (14 and 20 MPa), when compared with rough ones (4 and 13 MPa). These results suggest that porous implants improve the contact at the implant-bone interface and increase the fixation to the bone, improving the osseointegration. Thus, the porous implant might be an alternative to dental implant in less favorable conditions, and appear to be better fixed to bone, offering promising alternatives.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The present study was designed to analyze strain distributions caused by varying the fixture-abutment design and fixture alignment.Materials and Methods: Three implants of external, internal hexagon, and Morse taper were embedded in the center of each polyurethane block in straight placement and offset placement. Four strain gauges (SGs) were bonded on the surface of polyurethane block, which was designated SG1 placed mesially adjacent to implant A, SG2 and SG3 were placed mesially and distally adjacent to the implant B and SG4 was placed distally adjacent to the implant C. The 30 superstructures' occlusal screws were tightened onto the Microunit abutments with a torque of 10 N cm using the manufacturers' manual torque-controlling device.Results: There were statistically significant differences in prosthetic connection (P value = 0.0074 < 0.5). There were no statistically significant differences in placement configuration/alignment (P value = 0.7812 > 0.5).Conclusion: The results showed fundamental differences in both conditions. There was no evidence that there was any advantage to offset implant placement in reducing the strain around implants. The results also revealed that the internal hexagon and Morse taper joints did not reduce the microstrain around implants. (Implant Dent 2011; 20:e24-e32)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Different types of laser have been widely studied for applicability in the oral health area. In the endodontic area, investigations with some types of laser have been conducted to establish safe parameters for clinical application in root canals. However, it has not been duly explained whether the temperature increase caused by laser irradiation could cause alteration in the temperature on the external surface of the root and, consequently, alterations in the cells of the periodontal ligament, causing resorption and even loss of the dental element. The proposal in this paper was to gauge the external root temperature in the apical and cervical regions of the roots of human teeth during root canal irradiation with Nd:yttrium aluminum garnet (YAG) and Er:YAG lasers using different parameters. The novel approach of this paper is the use of the technique of laser applications along the total length of the root canal with series of repetitive irradiation, however, using time of 1 s of irradiation associated with 1 s off to avoid cumulative thermal effects. Experimental results confirm the accuracy of the parameters and exposure regimen obtained. All the parameters used in this paper are acceptable from a clinical as well as a biological point of view. (C) 2009 Laser Institute of America.
Resumo:
Bosonic boundary states at finite temperature are constructed as solutions of boundary conditions at T not equal0 for bosonic open strings with a constant gauge field F-ab coupled to the boundary. The construction is done in the framework of ther-mo field dynamics where a thermal Bogoliubov transformation maps states and operators to finite temperature. Boundary states are given in terms of states from the direct product space between the Fock space of the closed string and another identical copy of it. By analogy with zero temperature, the boundary states have the interpretation of Dp-branes at finite temperature. The boundary conditions admit two different solutions. The entropy of the closed string in a Dp-brane state is computed and analyzed. It is interpreted as the entropy of the Dp-brane at finite temperature.
Resumo:
The scattering of photons by a static gravitational field, treated as an external field, is discussed in the context of gravity with higher derivatives. It is shown that the R-2 sector of the theory does not contribute to the photon scattering, whereas the R-mu nu(2) sector produces dispersive (energy-dependent) photon propagation.
Resumo:
Starting from the Generating functional for the Green Function (GF), constructed from the Lagrangian action in the Duffin-Kemmer-Petiau (DKP) theory (L-approach) we strictly prove that the physical matrix elements of the S-matrix in DKP and Klein-Gordon-Fock (KGF) theories coincide in cases of interacting spin O particles with external and quantized Maxwell and Yang-Mills fields and in case of external gravitational field (without or with torsion), For the proof we use the reduction formulas of Lehmann, Symanzik and Zimmermann (LSZ). We prove that many photons and Yang-Mills particles GF coincide in both theories too. (C) 2000 Elsevier B.V. B.V. All rights reserved.
Resumo:
We investigate the spin of the electron in a non-relativistic context by using the Galilean covariant Pauli-Dirac equation. From a non-relativistic Lagrangian density, we find an appropriate Dirac-like Hamiltonian in the momentum representation, which includes the spin operator in the Galilean covariant framework. Within this formalism, we show that the total angular momentum appears as a constant of motion. Additionally, we propose a non-minimal coupling that describes the Galilean interaction between an electron and the electromagnetic field. Thereby, we obtain, in a natural way, the Hamiltonian including all the essential interaction terms for the electron in a general vector field.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Photopolymerized sol-gel monolithic columns for use in capillary electrochromatography were prepared in 125 mu m i.d. polyacrylate-coated fused-silica capillaries. The polyacrylate-coating, unlike the polyimide one, is transparent to the radiation used (approximate to 370 nm), and thus, no coating removal is necessary. This is a very important particularity since intrinsic capillary column characteristics, such as flexibility and mechanical resistance, are unchanged. A mixture containing metacryloxypropyltrimethoxysilane (MPTMS) as the polymeric precursor, hydrochloric acid as the catalyst, toluene as the porogen and bis(2,4,6-trimethylbenzoyl)-phenylphosphine oxide (Irgacure 819) as the photoinitiator was irradiated at 370 nm for 20 min inside the capillaries to prepare the columns through sol-gel approach. The versatility and viability of the use of polyacrilate as a new capillary external coating were shown through preparation of two columns under different conditions, which were tested in electrochromatography for separation of standard mixture containing thiourea (marker compound), propylbenzene, phenanthrene and pyrene. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: Estudar as alterações agudas da interface entre os parafusos e o tecido ósseo vertebral, considerando o diâmetro do orifício-piloto em relação ao diâmetro interno do parafuso. MÉTODOS: O estudo foi realizado em carneiros e a segunda vértebra cervical selecionada para o estudo. Foram utilizados parafusos corticais de 3,5mm de diâmetro externo (2,4mm de diâmetro interno) e 14mm de comprimento. Foram formados quatro grupos experimentais: 1) orifício-piloto de 2,0mm e colocação do parafuso de 3,5mm; 2) orifício-piloto de 2,5mm e colocação do parafuso de 2,5mm; 3) orifício-piloto de 2mm sem colocação do parafuso; e 4) orifício-piloto de 2,5mm sem colocação do parafuso. RESULTADOS: O grupo 1 (orifício-piloto menor do que o diâmetro interno do parafuso) apresentou maior densidade óssea no interior da rosca do implante e maior densidade óssea na área em espelho do que o grupo 2 (orifício-piloto maior que o diâmetro interno do parafuso). A superfície de contato entre o tecido ósseo e o implante foi maior no grupo 2 em relação ao grupo 1. A comparação da densidade óssea na área em espelho entre os grupos com e sem implante (1 e 3) e (2 e 4) mostrou que a densidade óssea era maior nos grupos com o implante. Não foi observada diferença estatística entre as comparações dos grupos experimentais. CONCLUSÃO: A utilização de orifício-piloto de menor diâmetro em relação ao diâmetro interno do parafuso apresentou tendência a provocar maior compactação do osso ao redor do implante.
Resumo:
Estudaram-se a morfologia externa, a sintopia e os dados métricos dos ovários, tubas uterinas e útero em 14 fêmeas adultas de cateto (12 adultas, uma prenhe e uma jovem) e em sete fêmeas de queixada (três jovens e quatro adultas), e o material, após fixação em solução aquosa de formol a 10%, foi dissecado. O material foi obtido na Universidade Federal de Uberlândia (UFU) - Campus Palotina e na Universidade Estadual Paulista - Campus de Ilha Solteira. Os ovários apresentaram-se ovalados e de superfície irregular, quando havia corpo lúteo ou folículo. As tubas uterinas mostraram-se longas, finas e enoveladas e terminando numa extremidade ovárica com fímbrias; a comunicação com o útero ocorreu de maneira contínua. Uma bolsa ovárica parcial, com um largo orifício, contém o ovário. O útero, bicórneo, apresentou um corpo curto e uma cérvix longa, com projeções anulares para o canal cervical, conferindo-lhe luz espiralada. Os cornos uterinos mostraram-se curtos, voltados ventralmente e em forma de hélice.