926 resultados para external firing
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Spontaneous isolated dissection of iliac arteries is very rare, with few reports in the literature. Medical, surgical, and endovascular treatment modalities have all been used to manage iliac artery dissections. We report a case of symptomatic, isolated, spontaneous dissection of the common iliac and external iliac arteries. Both dissections were successfully treated by separate percutaneous stent-graft placement, preserving hypogastric artery flow. This technique is interesting because it provides adequate sealing of proximal and distal dissection sites while preserving hypogastric artery and pelvic flow.
Resumo:
AIM: To evaluate the occurrence of external apical root resorption (EARR) in the incisors after anterior retraction in corrective orthodontic treatment with first premolar extractions and whether it was related with the type of root apex movement and its inclination. METHOD: The maxillary and mandibular incisors of 22 patients (12 to 25 years of age; 9 males and 13 females) were treated with fixed appliances and premolar extraction. EARR was defined as the difference in root length before and after incisal retraction on periapical radiographs. Distortion of radiographic images and changes due to incisal tipping were controlled for. Pre- and post-incisal retraction lateral cephalometric radiographs established the relationship between EARR and the tipping of the incisors, along with the vertical, horizontal, and total movement of the root apex. RESULTS: There was significant EARR (1.51 to 2.37 mm) during incisor retraction, but this was not related to the movement or the tipping of the root apex of almost all teeth. It was observed that after the retraction stage, EARR occurred in all evaluated incisors, but it was more significant (P < .05) in the mandibular right lateral incisor. CONCLUSION: The EARR that did occur was unrelated to movement or tipping of the root apex, except for the vertical root apex movement of the mandibular left central incisor and the inclination of the maxillary right lateral incisor.
Resumo:
This study evaluated the effect of Er,Cr:YSGG laser irradiation on the external adaptation of composite resin restorations in caries-affected cavities. Mixed class V cavity preparations were performed in 36 intact human third molars, in half of which caries was artificially induced. Both healthy and carious dentin were etched with 35% phosphoric acid (Ultradent Products Inc., South Jordan, Utah, USA), and the teeth were divided into three groups, i.e., (a) untreated etched dentin, (b) application of the Er, Cr:YSGG laser and (c) use of chlorhexidine as an adjunct in the bonding process. Restorations were fabricated with Z350 XT FiltekTM composite resin (3M ESPE) and subsequently the specimens were subjected to thermocycling to simulate artificial ageing. Quantitative analysis of external adaptation was performed by scanning electron microscopy in both healthy and affected dentin using epoxy resin replicas. It was concluded that the application of laser and chlorhexidine did not affect the percentages of marginal adaptation of class V restorations. Furthermore, thermocycling may influence adaptation values.
Resumo:
This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This systematic review aimed to evaluate if the internal connection is more efficient than the external connection and its associated influencing factors. A specific question was formulated according to the Population, Intervention, Control, and Outcome (PICO): Is internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? An electronic search of the MEDLINE and the Web of Knowledge databases was performed for relevant studies published in English up to November 2013 by two independent reviewers. The keywords used in the search included a combination of dental implant and internal connection or Morse connection or external connection. Selected studies were randomized clinical trials, prospective or retrospective studies, and in vitro studies with a clear aim of investigating the internal and/or external implant connection use. From an initial screening yield of 674 articles, 64 potentially relevant articles were selected after an evaluation of their titles and abstracts. Full texts of these articles were obtained with 29 articles fulfilling the inclusion criteria. Morse taper connection has the best sealing ability. Concerning crestal bone loss, internal connections presented better results than external connections. The limitation of the present study was the absence of randomized clinical trials that investigated if the internal connection was more efficient than the external connection. The external and internal connections have different mechanical, biological, and esthetical characteristics. Besides all systems that show proper success rates and effectiveness, crestal bone level maintenance is more important around internal connections than external connections. The Morse taper connection seems to be more efficient concerning biological aspects, allowing lower bacterial leakage and bone loss in single implants, including aesthetic regions. Additionally, this connection type can be successfully indicated for fixed partial prostheses and overdenture planning, since it exhibits high mechanical stability.
Resumo:
Adolescents are seeking new references and experiences, which may involve attitudes of risk and exposure to accidents and violence from external causes. These events constitute a serious Public Health problem. The scope of this study was to analyze the occurrence of accidents by external causes in adolescents from 10 to 19 years of age attended at sentinel urgency and emergency services in Brazil. Data from the 2009 Surveillance System for Violence and Accidents (VIVA 2009) was analyzed in 74 emergency units in 23 state capitals and the Federal District. The findings revealed that 6,434 adolescents (89.8%) were victims of accidents and 730 (10.2 %) were victims of violence. The main causes of the accidents were falls and traffic accidents, and assaults were predominant in violence. For both accidents and violence, non-white male adolescents were predominant and the events occurred most frequently on the public highways. A marked increase was detected, with hospitalization of victims of violence between 15 and 19 years of age. Understanding the epidemiological reality of external causes among adolescents represents an important tool for health prevention and promotion policies and the culture of peace seeking to reduce morbidity and mortality.
Resumo:
This article estimates the impact of mortality from external causes on the human development index (HDI) along the Brazilian borderland from 2000 to 2005. Data obtained from Brazilian government agencies were combined using the methodology defined by the United Nations Development Program, revealing the HDI according to actual conditions. Subsequently, deaths from external causes were excluded in order to estimate their impact on the index, recalculating life expectancy using the technique of competing causes. HDI showed a gradual increase from North to South, with the most developed regions concentrated in the South, consistent with studies using other sets of economic indicators. By excluding mortality from external causes, the highest gains appeared in regions where the HDI (under actual conditions) were lower, and the magnitude of gains declined towards the South.
Resumo:
We find the first nonlinear correction to the field produced by a static charge at rest in a background constant magnetic field. It is quadratic in the charge and purely magnetic. The third-rank polarization tensor-the nonlinear response function-is written within the local approximation of the effective action in an otherwise model-and approximation-independent way within any P-invariant nonlinear electrodynamics, QED included. DOI: 10.1103/PhysRevD.86.125028
Resumo:
The immatures of Polybia paulista Ihering were described using light and scanning electron microscopy and the results are compared with previous descriptions within the same or related wasps. This study is based on 2 whole nests collected in the municipality of Rio Claro, Sao Paulo, in Brazil. We have detected the existence of 5 larval instars. The main morphological alterations over development occur in the relative size of structures, yet certain structures appear with subsequent instars and become more evident later in development: increasing density in the number of body spines and papillae; the appearance of body setae in fifth-instar larvae; opening of spiracles upon second-instar larvae; 2 body shapes in fifth-instar larvae; the appearance of a lateral tooth on the mandibles of fourth instar; presence of spines on the maxillae of fifth-instar larvae; altered shape of galea and palps upon third-instar larvae from a cluster of sensilla to a conical elevation; and the appearance of spines on postmentum upon fourth-instar larvae. This way, the present study presents a detailed description of the immatures of P. paulista, and we hope the presented information can be useful to morphological, taxonomic, and phylogenetic studies.
Resumo:
Twelve participants ran (9 km . h(-1)) to test two types of running shoes: replica and original shoes. Ground reaction force, plantar pressure and electromyographic activity were recorded. The shoes were tested randomly and on different days. Comparisons between the two experimental conditions were made by analysis of variance (ANOVA) test (P <= 0.05). The time to first peak, loading rate of the first peak and impulse of the first 75 ms of stance were significantly different between the shoes (P <= 0.05), revealing an increase of impact forces for the replica shoes. The peak plantar pressure values were significantly higher (P <= 0.05) when wearing replica shoes. During running, the contact area was significantly smaller (P <= 0.05) for the replica shoe. The electromyographic activity of the analysed muscles did not show changes between the two shoes in running. These findings suggest that the use of replica running shoes can increase the external load applied to the human body, but may not change the muscle activity pattern during locomotion. This new mechanical situation may increase the risk of injuries in these movements.
Resumo:
Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns. Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05). Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05). Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50)